Cisco N9300-GX Series Switches are fixed-form-factor data center platforms for Cisco ACI spine, ACI leaf, and Cisco NX-OS deployments. The family combines 100-, 400-, and 40-Gbps interfaces, 12-Tbps or 12.8-Tbps switching capacity, more than 4.3 billion packets per second on selected models, and 1+1 power-supply redundancy. The principal selection decision is port architecture: N9K-C9316D-GX concentrates 400G QSFP-DD interfaces, N9K-C93600CD-GX combines QSFP28 downlinks with QSFP-DD uplinks, and N9K-C9364C-GX provides 64 QSFP28 ports in a 2RU chassis.

Three hardware profiles define the N9300-GX family

The three Cisco N9300-GX platforms address different data center connectivity patterns rather than representing simple port-count variations. N9K-C9316D-GX is the high-speed spine-oriented option with 16 400/100/40-Gbps QSFP-DD ports. N9K-C93600CD-GX is a mixed-speed spine-and-leaf switch with 28 QSFP28 ports and eight QSFP-DD ports. N9K-C9364C-GX supplies the highest native 100/40-Gbps port density with 64 QSFP28 interfaces.

Model Description Form factor Switching capacity Packet rate Best For
N9K-C9316D-GX 16 x 400/100-Gbps QSFP-DD ports 1RU 12.8 Tbps Over 4.3 bpps 400G-capable spine and high-bandwidth fabric roles
N9K-C93600CD-GX 28 x 100/40-Gbps QSFP28 ports and 8 x 400/100-Gbps QSFP-DD ports 1RU 12 Tbps 4.0 bpps Mixed 100G access and 400G uplink designs
N9K-C9364C-GX 64 x 100/40-Gbps QSFP28 ports 2RU 12.8 Tbps Over 4.3 bpps Dense 40/100G aggregation and leaf connectivity

Cisco identifies the N9316D and N9364C descriptions as 16 x 400/100-Gbps QSFP-DD and 64 x 100/40-Gbps QSFP28, respectively. The N93600CD description explicitly separates its 28 QSFP28 interfaces from its eight QSFP-DD interfaces, which matters when designing breakout layouts and matching optics to downlink or uplink roles.

Port speeds and breakout behavior need model-level validation

The supported-speed matrix differs substantially between the three chassis. N9K-C9316D-GX supports 40/100/400-Gbps Ethernet and breakout on all ports. Its stated breakout patterns include 2×200, 4×100, 2×100, 8×50, 4×50, 2×50, 4×25, and 4×10. Ten-Gigabit operation is available with QSA.

N9K-C93600CD-GX supports 40/100-Gbps on downlinks and 40/100/400-Gbps on uplinks. Ports 1 through 24 support 2x50G on all ports, while 4x10G and 4x25G are supported on odd ports with even ports purged. Ports 25 through 28 support 2x50G, 4x10G, and 4x25G on all ports. Ports 29 through 36 are converted downlinks and support 2x50G, 4x10G, 4x25G, and 4x100G. Ten-Gigabit operation is also supported with QSA.

N9K-C9364C-GX supports 40/100-Gbps Ethernet. Its breakout options are 2×50, 2×25, and 2×10 on all ports, plus 4×10 and 4x25G on all odd-numbered ports. Ten-Gigabit operation is supported with QSA.

Feature N9K-C9316D-GX N9K-C93600CD-GX N9K-C9364C-GX
Ports 16 x 400/100/40-Gbps QSFP-DD ports 28 x 100/40-Gbps QSFP28 ports and 8 x 400/100-Gbps QSFP-DD ports 64 x 100/40-Gbps QSFP28 ports
Supported speeds 40/100/400-Gbps Ethernet; breakout on all ports; 10G with QSA 40/100-Gbps downlinks; 40/100/400-Gbps uplinks; 10G with QSA 40/100-Gbps; 10G with QSA
Breakout detail 2×200, 4×100, 2×100, 8×50, 4×50, 2×50, 4×25, 4×10 Ports 1-24: 2x50G on all; 4x10G and 4x25G on odd ports with even ports purged. Ports 25-28: 2x50G, 4x10G, 4x25G. Ports 29-36: 2x50G, 4x10G, 4x25G, 4x100G 2×50, 2×25, 2×10 on all ports; 4×10 and 4x25G on odd ports
CPU 4 cores 4 cores 4 cores
System memory 32 GB 32 GB Up to 32 GB
SSD Drive 128 GB 128 GB 128 GB
System buffer 80 MB 80 MB 80 MB

The practical procurement implication is that interface count alone is not enough. A design using 400G fabric links should validate QSFP-DD availability on N9K-C9316D-GX or N9K-C93600CD-GX. A dense 100G leaf design should examine QSFP28 port placement and the stated odd/even breakout restrictions on N9K-C93600CD-GX and N9K-C9364C-GX. The datasheet does not provide a transceiver compatibility matrix, so specific third-party optical compatibility should not be inferred from the connector type alone.

ASIC resources support large routing and segmentation tables

The Cisco N9300-GX family provides substantial forwarding scale for data center fabrics. The platform supports 896,000 IPv4 LPM routes and 896,000 IPv4 host entries. IPv6 scale is 448,000 LPM routes and 896,000 host entries. The MAC address table supports up to 512,000 entries.

Capacity Cisco N9300-GX Series Switches Presales interpretation
Maximum IPv4 LPM routes 896,000 Large IPv4 fabric and routed-leaf tables
Maximum IPv4 host entries 896,000 High endpoint density
Maximum IPv6 LPM routes 448,000 Substantial IPv6 route scale
Maximum IPv6 host entries 896,000 High IPv6 endpoint scale
Maximum MAC address entries 512,000 Dense Layer 2 and VXLAN endpoint environments
Maximum multicast routes 32,000 Multicast-enabled data center services
IGMP snooping groups Shipping: 8000; Maximum: 32,000 Validate expected multicast group growth
Maximum ACL entries Per forwarding-engine slice: 5000 ingress; 2000 egress; maximum 20,000 ingress and 8000 egress Account for policy scale and direction
Maximum VLANs 4096 Standard VLAN segmentation ceiling stated by the source
VRF instances Shipping: 1000; Maximum: 16,000 Multi-tenant and segmented routing designs
Maximum ECMP paths 64 Leaf-spine equal-cost path selection
Maximum port channels 512 Aggregated uplink and host connectivity
Maximum links in a port channel 32 High-member EtherChannel designs
Active SPAN sessions 4 Monitoring and troubleshooting allocation
VLANs in RPVST instances 3967 Rapid per-VLAN spanning-tree scale
HSRP groups 490 First-hop redundancy planning
MST instances 64 Multiple Spanning Tree segmentation
Cisco Tetration Analytics flow-table size 64,000 Flow visibility capacity stated in the datasheet
NAT entries 1023 Confirm whether the stated NAT scale fits the deployment

These values describe platform ceilings, not a promise that every deployment will reach them simultaneously. The available forwarding profile, software configuration, feature combination, and operational design should be checked during solution validation.

ACI and software image requirements

All three exact hardware models support both ACI spine and ACI leaf roles. This makes the family suitable for fabrics in which the same hardware generation must serve different fabric positions, although port speed, density, and physical format still determine the appropriate placement.

Software or fabric function N9K-C9316D-GX N9K-C93600CD-GX N9K-C9364C-GX
ACI spine Yes Yes Yes
ACI leaf Yes Yes Yes
Minimum ACI image ACI-N9KDK9-14.2(2e) ACI-N9KDK9-14.2(2e) ACI-N9KDK9-14.2(3)
Minimum NX-OS image NXOS-9.3.3 NXOS-9.3.3 NXOS-9.3.3

The source identifies Cisco NX-OS image requirements and ACI image requirements, but it does not provide licensing quantities, subscription terms, or a Cisco Networking licensing mapping. Those commercial details should therefore be confirmed separately rather than inferred. The same boundary applies to Cisco IOS XE: these switches are documented with Cisco NX-OS and ACI image identifiers, not IOS XE software requirements.

Power architecture, thermal load, and rack planning

Power selection separates the 1RU models from the 2RU N9K-C9364C-GX. N9K-C9316D-GX and N9K-C93600CD-GX each use two 1100W power supplies with 1+1 redundancy. Their supported supply classes are 1100W AC, 1100W DC, and 1100W HVAC/HVDC. N9K-C9364C-GX uses two 2000W supplies with the same 1+1 redundancy concept across AC, DC, and HVAC/HVDC supply classes.

Power and environmental item N9K-C9316D-GX N9K-C93600CD-GX N9K-C9364C-GX
Power supplies 2, 1+1 redundancy; 1100W AC, 1100W DC, 1100W HVAC/HVDC 2, 1+1 redundancy; 1100W AC, 1100W DC, 1100W HVAC/HVDC 2, 1+1 redundancy; 2000W AC, 2000W DC, 2000W HVAC/HVDC
Typical power 420W 586W 811W
Maximum power 1010W 1071W 1622W
AC input voltage 100 to 240V 100 to 240V 100 to 240V
HVAC input voltage 100 to 277V 100 to 277V 100 to 277V
DC input voltage –40 to –72V –40 to –72V –40 to –72V
HVDC input voltage –240 to –380V –240 to –380V –240 to –380V
AC frequency 50 to 60 Hz 50 to 60 Hz 50 to 60 Hz
Fans 5+1 redundancy 5+1 redundancy 3+1 redundancy
Airflow Port-side intake and exhaust Port-side intake and exhaust Port-side intake and exhaust
Dimensions 1.72 x 17.37 x 25.5 in. (4.37 x 44.13 x 64.8 cm) 1.72 x 17.37 x 25.5 in. (4.37 x 44.13 x 64.8 cm) 3.39 x 17.41 x 22.59 in. (8.61 x 44.23 x 57.4 cm)
Acoustics 73.2 dBA at 50% fan, 81.8 dBA at 70%, 88.8 dBA at 100% 73.2 dBA at 50% fan, 81.8 dBA at 70%, 88.8 dBA at 100% 77.3 dBA at 50% fan, 88.6 dBA at 70%, 95.8 dBA at 100%

Typical power is useful for routine electrical and cooling estimation, while maximum power should be used for circuit, UPS, and thermal worst-case planning. The N9K-C9364C-GX has the highest stated maximum power at 1622W and the highest acoustic figures, so it warrants particular attention in room-level sound and heat calculations. All three models specify port-side intake and exhaust airflow options; the selected fan and power-supply airflow direction must match the rack’s cooling layout.

Management interfaces, reliability, and compliance

Each model includes two management ports consisting of one RJ-45 port and one SFP port, one USB port, and one RS-232 serial port. These interfaces provide separate management and console access paths without changing the model-level forwarding specifications.

Item N9K-C9316D-GX N9K-C93600CD-GX N9K-C9364C-GX
Management ports 2 ports: 1 RJ-45 and 1 SFP 2 ports: 1 RJ-45 and 1 SFP 2 ports: 1 RJ-45 and 1 SFP
USB Ports 1 1 1
RS-232 serial ports 1 1 1
RoHS compliance Yes Yes Yes
MTBF 323,140 hours 295,515 hours 237,760 hours

The source lists RoHS-6 compliance with exceptions for leaded BGA balls and lead press-fit connectors. Safety references include UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, and GB4943. EMC emissions references include 47CFR Part 15 Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, and CNS13438 Class A. EMC immunity references include EN55024, CISPR24, EN300386, and the KN 61000-4 series.

Ordering map for hardware, fans, power, and accessories

The ordering data separates chassis, fan options, power-supply options, and accessories. The fan airflow suffixes identify port-side intake or port-side exhaust. The 1RU models use 35CFM fan options and 1100W supply options, while N9K-C9364C-GX uses 160CFM fans and 2KW supply options.

Hardware model Part number Product description
N9K-C9316D-GX N9K-C9316D-GX N9316D Spine switch with 16p 400/100G QSFP-DD
N9K-C93600CD-GX N9K-C93600CD-GX N93600CD Spine and Leaf switch with 28p 100/40G QSFP28 and 8p 400/100G QSFP-DD
N9K-C9364C-GX N9K-C9364C-GX N9364C Spine and Leaf switch with 64p 100/40G QSFP28
Category Part number Product description
Fan option NXA-FAN-35CFM-PI Nexus Fan, N2000, 3000, 9000 Single Fan, 35CFM, port side intake airflow
Fan option NXA-FAN-35CFM-PE Nexus Fan, N2000, 3000, 9000 Single Fan, 35CFM, port side exhaust airflow
Fan option NXA-FAN-160CFM2PI Nexus Fan, N2000, 3000, 9000 Single Fan, 160CFM, port side intake airflow
Fan option NXA-FAN-160CFM2PE Nexus Fan, N2000, 3000, 9000 Single Fan, 160CFM, port side exhaust airflow
Power supply NXA-PAC-1100W-PI2 Nexus AC 1100W PSU Spare – port side intake
Power supply NXA-PAC-1100W-PE2 Nexus AC 1100W PSU Spare – port side exhaust
Power supply NXA-PDC-1100W-PI N1100W Platinum DC PS, port side intake
Power supply NXA-PDC-1100W-PE N1100W Platinum DC PS, port side exhaust
Power supply NXA-PHV-1100W-PI N1100W Platinum HV-AC-DC PS, port side intake
Power supply NXA-PHV-1100W-PE N1100W Platinum HV-AC-DC PS, port side exhaust
Power supply NXA-PAC-2KW-PI Nexus AC 2000W PSU Spare – port side intake
Power supply NXA-PAC-2KW-PE Nexus AC 2000W PSU Spare – port side exhaust
Power supply NXA-PDC-2KW-PI N2000W Platinum DC PS, port side intake
Power supply NXA-PDC-2KW-PE N2000W Platinum DC PS, port side exhaust
Power supply NXA-PHV-2KW-PI N2000W Platinum HV-AC-DC PS, port side intake
Power supply NXA-PHV-2KW-PE N2000W Platinum HV-AC-DC PS, port side exhaust
Accessory part number Product description Applicable ordering group
NXK-ACC-KIT-1RU N9000 Fixed Accessory Kit N9K-C9316D-GX and N9K-C93600CD-GX
N9K-C9300-RMK N9000 Fixed Rack Mount Kit N9K-C9364C-GX
N9K-C9300-ACK N9000 Fixed Accessory Kit N9K-C9364C-GX

Sustainability and source-bound procurement notes

The sustainability section identifies references for product material content laws and regulations under Materials, and electronic-waste laws and regulations covering products, batteries, and packaging under WEEE compliance. These entries are reference labels rather than additional hardware specifications.

Sustainability topic Reference
Information on product material content laws and regulations Materials
Information on electronic waste laws and regulations, including products, batteries, and packaging WEEE compliance

The source records an update concerning features, benefits, and breakout support for N9K-C93600CD-GX, described in Table 2. The publication date is intentionally not reproduced here. No EOL or EOS conclusion is established by this datasheet, and no lifecycle claim should be made from the source alone.

For procurement, the shortest decision path is to match the fabric role and interface speed first, then validate breakout requirements, airflow direction, maximum electrical load, and the exact power and fan part numbers. Use N9K-C9316D-GX where 400G QSFP-DD density is the primary requirement, N9K-C93600CD-GX where 100G QSFP28 and 400G QSFP-DD must coexist, and N9K-C9364C-GX where 64 native 100/40-Gbps QSFP28 ports justify a 2RU chassis and higher power envelope. Submit the complete chassis, fan direction, PSU type, accessory, software-image, and optical requirements through the standard RFQ process before finalizing a bill of materials.