| Overview |
|---|
| Full Product Name | QFX10002 Fixed Ethernet Switch |
| OS Supported | Junos OS |
| Chassis |
|---|
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 2 U |
| Chassis Height | 3.46 in / 8.7884 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 31 in / 78.74 cm |
| Chassis Depth (With FRUs) | 32.4 in / 82.296 cm |
| Chassis Weight (Fully Loaded With All Components) | 68.6 lb / 31.11 kg |
| Chassis Model Number | QFX10002-72Q-CHAS |
| Cooling System |
|---|
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX10002-FAN |
| Fan Module Count | 3 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| Environmental Specifications |
|---|
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| Built-in Network Ports |
|---|
| QSFP+ Port Count | 72 |
| QSFP+ Port Channelization | Y |
| Other Port Configuration |
|---|
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| Management Port 2 Count | 1 |
| Management Port 2 Type | SFP |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| PTP Port | Y |
| Performance (General) |
|---|
| Route Table Size (RIB) (IPv4) (Thousands) | 10000 |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (RIB) (IPv6) (Thousands) | 4000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| Performance (Routing/Switching) |
|---|
| Throughput | 5760 Gbps |
| Forwarding Capacity | 2 Bpps |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Multicast Routes (Thousands) | 128 |
| ARP Entries (Tunnel Mode) (Thousands) | 340 |
| LAGs Count | 144 |
| MAC Addresses Per System (Thousands) | 512 |
| MPLS IPv4 L3 VPNs | 4000 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 24 GB |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| Processor |
|---|
| CPU | 2.5-GHz quad core Intel |
| DRAM | 16 GB |
| Power System |
|---|
| PSU Count | 4 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JPSU-1600W-AC-AFO |
| AC Max Power Consumption | 1425 W |
| AC Average Power Consumption | 1050 W |
| AC PSU Max Heat Dissipation | 4862 BTU/h |
| AC PSU Average Heat Dissipation | 3583 BTU/h |
| Grounding Cable Lug Type | Panduit LCD6-14BH-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 8 AWG |
| Storage |
|---|
| Internal Storage Size | 50 (25+25) GB |
| Internal Storage Type | SSD |
| Supported Transceivers |
|---|
| CTP-SFP-1GE-LX (740-011614) | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module, CTP1000 |
| CTP-SFP-1GE-SX (740-011613) | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module, CTP1000 |
| CTP-SFP-1GE-T (740-013111) | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module (uses Cat 5 cable) |
| EX-SFP-10GE-DAC-1M (740-030076) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 1M |
| EX-SFP-10GE-DAC-3M (740-030077) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 3M |
| EX-SFP-10GE-DAC-5M (740-031838) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 5M |
| EX-SFP-10GE-ER (740-140355) | SFP+ 10GBase-ER 10 Gigabit Ethernet Optics Module, 1550nm for 40Km Transmission |
| EX-SFP-10GE-LR (740-021309) | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) LR Optics |
| EX-SFP-10GE-SR (740-021308) | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) SR Optics |
| EX-SFP-10GE-USR (740-030658) | SFP+ 10 Gigabit Ethernet Ultra Short Reach; 850 nm; 10m on OM1, 20m on OM2, 100m on OM3 Multi-Mode Fiber |
| EX-SFP-1GE-LX (740-011614) | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optics |
| EX-SFP-1GE-SX (740-011613) | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optics |
| EX-SFP-1GE-SX-ET (740-011613) | SFP, 1000Base-SX Gigabit Ethernet, Extended Temperature Range Optics |
| EX-SFP-1GE-T (740-013111) | Small Form Factor Pluggable 10/100/1000 Copper Transceiver Module |
| JNP-100G-AOC-10M (740-061411) | QSFP28 100G active optical cable for 10M |
| JNP-100G-AOC-15M (740-068217) | QSFP28 100G active optical cable for 15M |
| JNP-100G-AOC-1M (740-065630) | QSFP28 100G active optical cable for 1M |
| JNP-100G-AOC-20M (740-064981) | QSFP28 100G active optical cable for 20M |
| JNP-100G-AOC-30M (740-064980) | QSFP28 100G active optical cable for 30M |
| JNP-100G-AOC-3M (740-065631) | QSFP28 100G active optical cable for 3M |
| JNP-100G-AOC-5M (740-065632) | QSFP28 100G active optical cable for 5M |
| JNP-100G-AOC-7M (740-065633) | QSFP28 100G active optical cable for 7M |
| JNP-QSFP-100G-BXSR (740-080491) | 100GBASE-BXSR OM4 100m 850nm 70C |
| JNP-QSFP-100G-CWDM (740-061408) | 100G CWDM4 optics |
| JNP-QSFP-100G-LR4 (740-061409) | QSFP28 100GBase-LR4 Optics for up to 10km transmission over serial SMF |
| JNP-QSFP-100G-PSM4 (740-061406) | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF |
| JNP-QSFP-100G-SR4 (740-061405) | QSFP28 100GBase-SR4 Optics for up to 100m transmission over parallel MMF |
| JNP-QSFP-40G-LR4 (740-073095) | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF |
| JNP-QSFP-40G-LX4 (740-056705) | QSFP+ 40GBASE-LX4 40 Gigabit Optics for up to 150m transmission with OM4 over duplex MMF |
| JNP-QSFP-40GE-ER4 (740-066424) | |
| JNP-QSFP-40GE-IR4 (740-056707) | QSFP+ 40GBase-IR4 40 Gigabit Optics for up to 2 km transmission over SMF |
| JNP-QSFP-4X10GE-IR (740-056706) | QSFP+ 40GBASE optics, up to 1.4 km transmission on parallel single mode (4X10GbE long reach up to 1.4 km) |
| JNP-QSFP-4X10GE-LR (740-057315) | QSFP+ 40G breakout into 4x10GBASE LR up to 10km SMF, MPO-12 APC Receptacle |
| JNP-QSFP-DAC-10MA (740-053202) | QSFP+ 40GBase Direct Attach Copper Cable 10-meter,active |
| JNP-QSFP-DAC-5M (740-038625) | QSFP+ 40GBase Direct Attach Copper Cable 5-meter, passive |
| JNP-QSFP-DAC-5MA (740-052306) | QSFP+ 40GBase Direct Attach Copper Cable 5-meter, active |
| JNP-QSFP-DAC-7MA (740-052307) | QSFP+ 40GBase Direct Attach Copper Cable 7-meter, active |
| JNP-QSFP-DACBO-10M (740-053204) | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 10-meter, passive |
| JNP-QSFP-DACBO-5MA (740-044967) | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 5-meter, active |
| JNP-QSFP-DACBO-7MA (740-053203) | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 7-meter, active |
| JNP-QSFPP-40G-BXSR (740-080490) | 40GBASE-BXSR OM3 100m 850nm 70C |
| QFX-QSFP-40G-ESR4 (740-045627) | QSFP+ 40GBase-eSR4 40 Gigabit Optics, 850nm for up to 300m Transmission on MMF |
| QFX-QSFP-40G-SR4 (740-067442) | QSFP+ 40GBase-SR4 40 Gigabit Optics, 850nm for up to 150m transmission on MMF |
| QFX-QSFP-DAC-1M (740-038623) | QSFP+ Cable Assy, 1m, 30AWG, Passive, Programmable ID |
| QFX-QSFP-DAC-3M (740-038624) | QSFP+ Cable Assy, 3m, 30AWG, Passive, Programmable ID |
| QFX-QSFP-DACBO-1M (740-038152) | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 1m |
| QFX-QSFP-DACBO-3M (740-038153) | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 3m |
| QFX-SFP-10GE-ER (740-030128) | SFP+ 10GBase-ER 10 Gigabit Ethernet Optics, 1550nm for 40km transmission on SMF |
| QFX-SFP-10GE-LR (740-021309) | SFP+ 10GBase-LR 10 Gigabit Ethernet Optics, 1310nm for 10km transmission on SMF |
| QFX-SFP-10GE-SR (740-021308) | SFP+ 10GBase-SR 10 Gigabit Ethernet Optics, 850nm for up to 300m transmission on MMF |
| QFX-SFP-10GE-USR (740-030658) | SFP+ 10 Gigabit Ethernet Ultra Short Reach Optics, 850 nm for 10m on OM1, 20m on OM2, 100m on OM3 Multi-Mode Fiber |
| QFX-SFP-1GE-LX (740-011614) | SFP 1000Base-LX Gigabit Ethernet Optics, 1310nm for 10km transmission on SMF |
| QFX-SFP-1GE-SX (740-011613) | SFP 1000Base-SX Gigabit Ethernet Optics, 850nm for upto 550m transmission on MMF |
| QFX-SFP-1GE-T (740-013111) | SFP 1000Base-T Copper Transceiver Module for up to 100m transmission |
| QFX-SFP-DAC-10MA (740-037252) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (active twinax copper cable) 10m |
| QFX-SFP-DAC-1M (740-030076) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1m |
| QFX-SFP-DAC-1MA (740-037249) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (active twinax copper cable) 1m |
| QFX-SFP-DAC-3M (740-030077) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 3m |
| QFX-SFP-DAC-3MA (740-032276) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (active twinax copper cable) 3m |
| QFX-SFP-DAC-5M (740-031838) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 5m |
| QFX-SFP-DAC-5MA (740-037250) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (active twinax copper cable) 5m |
| QFX-SFP-DAC-7MA (740-032277) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (active twinax copper cable) 7m |
| QSFP-100G-CWDM-C (740-061408) | QSFP-28, 100G-CWDM4 Transceiver |
| QSFP-100G-CWDM-T2 (740-061408) | |
| QSFP-100G-DR (740-088322) | QSFP28 100GBASE-DR; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 500 m; Standard Temperature (0 through 70°C); Duplex LC connector |
| QSFP-100G-ER4L (740-071175) | QSFP28 100G-ER4 Lite Ethernet only module |
| QSFP-100G-FR (740-088320) | QSFP28 100G-FR/100GBASE-FR1; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 2 km; Standard Temperature (0 through 70°C); Duplex LC connector |
| QSFP-100G-LR4-C (740-061409) | QSFP-28, 100G-LR4 Transceiver |
| QSFP-100G-LR4-T2 (740-061409) | 100G-LR4 Ethernet only QSFP28 Module T2 |
| QSFP-100G-PSM4-T2 (740-061406) | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF |
| QSFP-100G-SR4-C (740-061405) | QSFP-28, 100G-SR4 Transceiver |
| QSFP-100G-SR4-T2 (740-061405) | 100G-SR4 Ethernet only QSFP28 Module T2 |
| QSFPP-40G-LR4-C (740-073095) | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF |
| QSFPP-40G-LX4 (740-062254) | QSFP+ 40GBase-LX4 40 Gigabit Optics, 100m(150m) with OM3(OM4) duplex MMF fiber |
| QSFPP-4X10GE-LR (740-054050) | 40G QSFP+ breakout into 4x10GBASE LR Ethernet module |
| QSFPP-4X10GE-SR (740-054053) | 40G QSFP+ breakout into 4x10GBASE SR Ethernet module |
| SFP-1G-LX-C (740-011614) | SFP, 1G, SMF 10km and MMF 550m, Extended Temperature (-5 through 70 DegC), Duplex LC connector |
| SFP-1G-SX-C (740-011613) | SFP, 1G, FDDI 220m and OM1 275m/OM2 MMF 550m, Extended Temperature (-10 through 85 DegC), Duplex LC connector |
| SFP-1G-T-C (740-013111) | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module (uses Cat 5 cable) |
| SFP-1GE-SX (740-031851) | GE SFP SX Plug In, Module |
| SFPP-10G-LRT2-C (740-021309) | SFP+, 10G-LR Transceiver type 2 |
| SFPP-10G-SR-C (740-021308) | SFP+, 10G-SR Transceiver |
| SFPP-10G-SR-ET-C (740-031980) | SFP+ 10GE-SR MMF 1.0W Beige Bail |
| SFPP-10G-USR-C (740-030658) | SFP+, 10G-USR Transceiver |
| SRX-SFP-10GE-DAC-1M (740-030076) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 1M |
| SRX-SFP-10GE-DAC-3M (740-030077) | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 3M |
| SRX-SFP-10GE-ER (740-140355) | SFP+ 10GBase-ER 10 Gigabit Ethernet Optics Module, 1550nm for 40Km transmission |
| SRX-SFP-10GE-LR (740-021309) | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) LR Optics |
| SRX-SFP-10GE-SR (740-021308) | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) SR Optics |
| SRX-SFP-1GE-LX (740-011614) | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module |
| SRX-SFP-1GE-LX-ET (740-011614) | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module - Extended temperature |
| SRX-SFP-1GE-SX (740-011613) | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module |
| SRX-SFP-1GE-SX-ET (740-011613) | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module - Extended temperature |
| SRX-SFP-1GE-T (740-013111) | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module |
| SRX-SFPP-10G-SR-ET (740-031980) | SFP+ 10GE pluggable transceiver, short reach, 850nm for 200m transmission, Extended temperature 0-85 |
| Power Supply Modules (PSM) |
|---|
| JPSU-1600W-AC-AFO (740-054405) | 1600W AC PSU front-to-back airflow |
| JPSU-1600W-DC-AFO (740-054567) | 1600W DC PSU front-to-back airflow |
| Power Cords/Cables |
|---|
| CBL-EX-PWR-C13-AR | AC Power Cable - Argentina (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-AU | Power Cable, Australia |
| CBL-EX-PWR-C13-BR | AC Power Cable - Brazil (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-CH | Power Cable, China |
| CBL-EX-PWR-C13-EU | Power Cable, Europe |
| CBL-EX-PWR-C13-IL | AC Power Cable - Israel (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-IN | AC Power Cable - India (6A/250V, 2.5m) |
| CBL-EX-PWR-C13-IT | Power Cable, Italy |
| CBL-EX-PWR-C13-JP | Power Cable, Japan |
| CBL-EX-PWR-C13-KR | Power Cable, Korea |
| CBL-EX-PWR-C13-SA | AC Power Cable - South Africa (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-SZ | Power Cable, Switzerland |
| CBL-EX-PWR-C13-UK | Power Cable, UK |
| CBL-EX-PWR-C13-US | Power Cable, US |
| CG_CBL-C13-06 | |
| Adapters |
|---|
| MAM1Q00A-QSA | |