| Overview |
|---|
| Full Product Name | QFX5120 Switch |
| OS Supported | Junos OS |
| Chassis |
|---|
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Depth (With FRUs) | 22.7 in / 57.658 cm |
| Chassis Weight (Fully Loaded With All Components) | 24.25 lb / 11 kg |
| Chassis Cluster/High Availability/Virtual Chassis |
|---|
| Count of Devices in Virtual Chassis | 2 |
| Cooling System |
|---|
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Airflow Volume | 132 CFM |
| Fan Module Model Number | QFX5110-FANAFO |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| Environmental Specifications |
|---|
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 95% |
| Maintenance Clearance | 30 in / 76.2 cm |
| Built-in Network Ports |
|---|
| RJ-45 Port Count | 48 |
| Other Port Configuration |
|---|
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| Uplink Port Count | 6 |
| Uplink Port Type | QSFP28 |
| 10 MHz Port | Y |
| PPS Port | Y |
| Performance (Routing/Switching) |
|---|
| Throughput (Bidirectional) | 2160 Gbps |
| Throughput (Unidirectional) | 1080 Gbps |
| Forwarding Capacity | 1 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 211 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 351 |
| IPv4 Unicast ECMP Paths | 64 |
| IPv4 Multicast Routes (Thousands) | 106 |
| IPv6 Unicast Host Routes (Thousands) | 106 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 500 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 172 |
| IPv6 Multicast Routes (Thousands) | 52 |
| ARP Entries (Thousands) | 64 |
| MSTP Instances | 64 |
| VSTP Instances | 509 |
| LAGs Count | 64 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 288 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4094 |
| Jumbo Frame | 9216 bytes |
| Processor |
|---|
| CPU | 2.2 GHz quad-core Intel |
| DRAM | 16 GB |
| Power System |
|---|
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JPSU-650W-AC-AO |
| AC Max Power Consumption | 251 W |
| AC Average Power Consumption | 205 W |
| HVAC PSU Model Number | JPSU-850W-HV-AFO |
| HVAC Max Power Consumption | 440 W |
| HVAC Average Power Consumption | 290 W |
| Storage |
|---|
| Internal Storage Size | 100 GB |
| Internal Storage Type | SSD |
| Supported Transceivers |
|---|
| JNP-100G-2X50G-1M | 100G DAC Breakout into 2x50G 1M (720-068904) |
| JNP-100G-2X50G-2M | 100G DAC Breakout into 2x50G 2M (720-068905) |
| JNP-100G-2X50G-3M | 100G DAC Breakout into 2x50G 3M (720-068906) |
| JNP-100G-2X50G-5M | 100G DAC Breakout into 2x50G 5M (720-128947) |
| JNP-100G-4X25G-1M | 100G QSFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 1m (720-068901) |
| JNP-100G-4X25G-3M | 100G QSFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 3m (740-061003) |
| JNP-100G-4X25G-5M | 100G QFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 5m (720-071265) |
| JNP-100G-DAC-1M | 100G DAC Twinax Copper Cable 1M (740-061000) |
| JNP-100G-DAC-3M | 100G DAC Twinax Copper Cable 3M (740-061001) |
| JNP-100G-DAC-5M | 100G DAC Twinax Copper Cable 5M (740-061002) |
| JNP-QSFP-100G-BXSR | 100GBASE-BXSR OM4 100m 850nm 70C (740-080491) |
| JNP-QSFP-100G-CWDM | 100G CWDM4 optics (740-061408) |
| JNP-QSFP-100G-LR4 | QSFP28 100GBase-LR4 Optics for up to 10km transmission over serial SMF (740-061409) |
| JNP-QSFP-100G-PSM4 | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF (740-061406) |
| JNP-QSFP-100G-SR4 | QSFP28 100GBase-SR4 Optics for up to 100m transmission over parallel MMF (740-061405) |
| JNP-QSFP-40G-LR4 | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF (740-073095) |
| JNP-QSFP-40G-LX4 | QSFP+ 40GBASE-LX4 40 Gigabit Optics for up to 150m transmission with OM4 over duplex MMF (740-056705) |
| JNP-QSFP-40GE-ER4 | (740-066424) |
| JNP-QSFP-40GE-IR4 | QSFP+ 40GBase-IR4 40 Gigabit Optics for up to 2 km transmission over SMF (740-056707) |
| JNP-QSFP-4X10GE-LR | QSFP+ 40G breakout into 4x10GBASE LR up to 10km SMF, MPO-12 APC Receptacle (740-057315) |
| JNP-QSFP-DAC-10MA | QSFP+ 40GBase Direct Attach Copper Cable 10-meter,active (740-053202) |
| JNP-QSFP-DAC-5M | QSFP+ 40GBase Direct Attach Copper Cable 5-meter, passive (740-038625) |
| JNP-QSFP-DAC-7MA | QSFP+ 40GBase Direct Attach Copper Cable 7-meter, active (740-052307) |
| JNP-QSFP-DACBO-10M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 10-meter, passive (740-053204) |
| JNP-QSFP-DACBO-5MA | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 5-meter, active (740-044967) |
| JNP-QSFP-DACBO-7MA | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 7-meter, active (740-053203) |
| JNP-QSFPP-40G-BXSR | 40GBASE-BXSR OM3 100m 850nm 70C (740-080490) |
| QFX-QSFP-40G-ESR4 | QSFP+ 40GBase-eSR4 40 Gigabit Optics, 850nm for up to 300m Transmission on MMF (740-045627) |
| QFX-QSFP-40G-SR4 | QSFP+ 40GBase-SR4 40 Gigabit Optics, 850nm for up to 150m transmission on MMF (740-067442) |
| QFX-QSFP-DAC-1M | QSFP+ Cable Assy, 1m, 30AWG, Passive, Programmable ID (740-038623) |
| QFX-QSFP-DAC-3M | QSFP+ Cable Assy, 3m, 30AWG, Passive, Programmable ID (740-038624) |
| QFX-QSFP-DACBO-1M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 1m (740-038152) |
| QFX-QSFP-DACBO-3M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 3m (740-038153) |
| QSFP-100G-4WDM40 | QSFP28 100G 4WDM-40 transceiver (740-093290) |
| QSFP-100G-CWDM-C | QSFP-28, 100G-CWDM4 Transceiver (740-061408) |
| QSFP-100G-CWDM-T2 | (740-061408) |
| QSFP-100G-DAC-50CM | QSFP28 100G DAC 50 cm (720-130465) |
| QSFP-100G-DR | QSFP28 100GBASE-DR; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 500 m; Standard Temperature (0 through 70°C); Duplex LC connector (740-088322) |
| QSFP-100G-ER4L | QSFP28 100G-ER4 Lite Ethernet only module (740-071175) |
| QSFP-100G-FR | QSFP28 100G-FR/100GBASE-FR1; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 2 km; Standard Temperature (0 through 70°C); Duplex LC connector (740-088320) |
| QSFP-100G-LR | QSFP28 100G-LR/100GBASE-LR1; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 10 km; Standard Temperature (0 through 70°C); Duplex LC connector (740-096178) |
| QSFP-100G-LR4-C | QSFP-28, 100G-LR4 Transceiver (740-061409) |
| QSFP-100G-LR4-T2 | 100G-LR4 Ethernet only QSFP28 Module T2 (740-061409) |
| QSFP-100G-PSM4-T2 | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF (740-061406) |
| QSFP-100G-SR1P2 | QSFP28 100G SR BiDi Transceiver (740-158998) |
| QSFP-100G-SR4-C | QSFP-28, 100G-SR4 Transceiver (740-061405) |
| QSFP-100G-SR4-T2 | 100G-SR4 Ethernet only QSFP28 Module T2 (740-061405) |
| QSFP-100G-ZR4 | QSFP28 100G ZR4 Transceiver (740-120240) |
| QSFPP-40G-LR4-C | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF (740-073095) |
| QSFPP-4X10GE-SR | 40G QSFP+ breakout into 4x10GBASE SR Ethernet module (740-054053) |
| Compatible Power Supply Modules |
|---|
| JPSU-650W-AC-AFI | Juniper 650W AC Power Supply (FRU Side to Port Side Air Flow) (740-044332) |
| JPSU-650W-AC-AI | Juniper 650W AC Power Supply (FRU Back to Front Air Flow) |
| JPSU-650W-AC-AO | JNP204 AC power supply air flow out |
| JPSU-650W-DC-AFI | Juniper 650W DC Power Supply (FRU Side to Port Side Air Flow) (740-038949) |
| JPSU-650W-DC-AFO | Juniper 650W DC Power Supply (Port Side to FRU Side Air Flow) (740-043886) |
| JPSU-850W-HV-AFI | QFX5K and other platforms HV 277VAC/380VDC POWER SUPPLY MODULE, Back to Front Airflow (740-099040) |
| JPSU-850W-HV-AFO | QFX5K and other platforms HV 277VAC/380VDC POWER SUPPLY MODULE, Front to Back Airflow (740-099043) |
| Power Cords/Cables |
|---|
| CBL-EX-PWR-C13-AR | AC Power Cable - Argentina (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-AU | Power Cable, Australia |
| CBL-EX-PWR-C13-BR | AC Power Cable - Brazil (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-C14 | AC Power Cable - Patch Cord, (10A/250V, 2.5m) (740-034568) |
| CBL-EX-PWR-C13-CH | Power Cable, China |
| CBL-EX-PWR-C13-EU | Power Cable, Europe |
| CBL-EX-PWR-C13-IL | AC Power Cable - Israel (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-IN | AC Power Cable - India (6A/250V, 2.5m) |
| CBL-EX-PWR-C13-IT | Power Cable, Italy |
| CBL-EX-PWR-C13-JP | Power Cable, Japan |
| CBL-EX-PWR-C13-KR | Power Cable, Korea |
| CBL-EX-PWR-C13-SA | AC Power Cable - South Africa (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-SZ | Power Cable, Switzerland |
| CBL-EX-PWR-C13-UK | Power Cable, UK |
| CBL-EX-PWR-C13-US | Power Cable, US |
| CG_CBL-C13-06 | |
| Rack Mounting Kits |
|---|
| EX-4PST-RMK | 4-Post Adjustable Rack Mount Kit for EX4400, EX4300, EX4100, EX3400, EX4100-F, and EX2300 Switches (760-030688) |
| EX-RMK | Rack Mount Kit for EX4400, EX4300, EX4100, EX3400, EX4100-F, and EX2300 Switches (760-020907) |
| JNP-4PST-RMK-1U-E | Enhanced 4-Post Rack Mount Kit for 1RU platform (760-141941) |