Product Overview
The Juniper QFX5130-48CM-AFO is a high-performance network component designed for the QFX5130-48CM series.

| تعداد | قیمت واحد | صرفهجویی تخمینی |
|---|---|---|
| 1 واحد | $272.20 | - |
| 2 - 9 واحد | درخواست قیمت | 5 - 10% |
| 10+ / پروژه | تطبیق چارچوب | دسترسی سطح ۱ |
Our CCIE certified engineers can help you verify compatibility.
Global logistics network aiming for same-day handover.
Every unit undergoes rigorous 38-point inspection test.
Trusted by enterprise clients across 6 continents.
Certified network engineers ready to assist with configuration.
The Juniper QFX5130-48CM-AFO is a high-performance network component designed for the QFX5130-48CM series.
| QFX5130-48CM-AFO — Overview | |
|---|---|
| Full Product Name | QFX5130-48CM Switch |
| OS Supported | Junos OS Evolved |
| First OS Release Supported | 23.4R2S1-EVO |
| QFX5130-48CM-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in. / 4.3 cm |
| Chassis Width | 17.28 in. / 43.9 cm |
| Chassis Depth | 20.5 in. / 52.1 cm |
| Chassis Weight (As Shipped) | 27 lb /12.24 kg |
| Chassis Model Number | QFX5130-48CM-AFO |
| QFX5130-48CM-AFO — Cooling System | |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5130-48C-FANAO |
| Fan Module Count | 6 |
| Fan Module Redundancy | Yes |
| Fan Module Hot-Removable And Hot-Insertable? | Yes |
| QFX5130-48CM-AFO — Environmental Specifications | |
| Operating Temperature | 32°F through 104°F /0° through 40°C |
| Storage Temperature | -40°F through 158°F /-40° through 70°C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in./ 76.2 cm |
| QFX5130-48CM-AFO — Built-in Network Ports | |
| SFP-DD Port Count | 48 |
| SFP-DD Port Channelization | Y |
| SFP-DD Port – MACsec Support? | Y |
| QSFP-DD Port Count | 8 |
| QSFP-DD Port Channelization | Y |
| QSFP-DD Port – MACsec Support? | Y |
| QFX5130-48CM-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP-DD |
| 10 MHz Port | 1 |
| PPS Port | 1 |
| QFX5130-48CM-AFO — Performance (Routing/Switching) | |
| Throughput | 16 |
| Throughput (Bidirectional) | 16 |
| Throughput (Unidirectional) | 8 |
| Forwarding Capacity | 2.7E9 |
| Egress VLAN ACL | 2000 |
| Egress Port ACL | 4000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 28671.0 |
| Ingress Port ACL | 14335.0 |
| Ingress Routed ACL | 28671.0 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 72 |
| MAC Addresses Per System (Thousands) | 96000.0 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216.0 |
| Total Packet Buffer | 0.082 |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5130-48CM-AFO — Processor | |
| CPU | Intel Ice Lake (4 core) |
| DRAM | 32 |
| QFX5130-48CM-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Yes |
| AC PSU Model Number | JPSU-1600W-1UACAFO |
| AC Max Power Consumption | 641 |
| AC Average Power Consumption | 253 |
| Grounding Cable Lug Type | Panduit LCD6-14A-L |
| QFX5130-48CM-AFO — Storage | |
| Storage Size | 200 |
| Storage Type | SSD |
| QFX5130-48CM-AFI — Overview | |
| Full Product Name | QFX5130-48CM Switch |
| OS Supported | Junos OS Evolved |
| First OS Release Supported | 23.4R2S1-EVO |
| QFX5130-48CM-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in. / 4.3 cm |
| Chassis Width | 17.28 in. / 43.9 cm |
| Chassis Depth | 20.5 in. / 52.1 cm |
| Chassis Weight (As Shipped) | 27 lb /12.24 kg |
| Chassis Model Number | QFX5130-48CM-AFO |
| QFX5130-48CM-AFI — Cooling System | |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5130-48C-FANAO |
| Fan Module Count | 6 |
| Fan Module Redundancy | Yes |
| Fan Module Hot-Removable And Hot-Insertable? | Yes |
| QFX5130-48CM-AFI — Environmental Specifications | |
| Operating Temperature | 32°F through 104°F /0° through 40°C |
| Storage Temperature | -40°F through 158°F /-40° through 70°C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in./ 76.2 cm |
| QFX5130-48CM-AFI — Built-in Network Ports | |
| SFP-DD Port Count | 48 |
| SFP-DD Port Channelization | Y |
| SFP-DD Port – MACsec Support? | Y |
| QSFP-DD Port Count | 8 |
| QSFP-DD Port Channelization | Y |
| QSFP-DD Port – MACsec Support? | Y |
| QFX5130-48CM-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP-DD |
| 10 MHz Port | 1 |
| PPS Port | 1 |
| QFX5130-48CM-AFI — Performance (Routing/Switching) | |
| Throughput | 16 |
| Throughput (Bidirectional) | 16 |
| Throughput (Unidirectional) | 8 |
| Forwarding Capacity | 2.7E9 |
| Egress VLAN ACL | 2000 |
| Egress Port ACL | 4000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 28671.0 |
| Ingress Port ACL | 14335.0 |
| Ingress Routed ACL | 28671.0 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 72 |
| MAC Addresses Per System (Thousands) | 96000.0 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216.0 |
| Total Packet Buffer | 0.082 |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5130-48CM-AFI — Processor | |
| CPU | Intel Ice Lake (4 core) |
| DRAM | 32 |
| QFX5130-48CM-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Yes |
| AC PSU Model Number | JPSU-1600W-1UACAFI |
| AC Max Power Consumption | 641 |
| AC Average Power Consumption | 253 |
| Grounding Cable Lug Type | Panduit LCD6-14A-L |
| QFX5130-48CM-AFI — Storage | |
| Storage Size | 200 |
| Storage Type | SSD |
| QFX5130-48CM-D-AFO — Overview | |
| Full Product Name | QFX5130-48CM Switch |
| OS Supported | Junos OS Evolved |
| First OS Release Supported | 23.4R2S1-EVO |
| QFX5130-48CM-D-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in. / 4.3 cm |
| Chassis Width | 17.28 in. / 43.9 cm |
| Chassis Depth | 20.5 in. / 52.1 cm |
| Chassis Weight (As Shipped) | 27 lb /12.24 kg |
| Chassis Model Number | QFX5130-48CM-AFO |
| QFX5130-48CM-D-AFO — Cooling System | |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5130-48C-FANAO |
| Fan Module Count | 6 |
| Fan Module Redundancy | Yes |
| Fan Module Hot-Removable And Hot-Insertable? | Yes |
| QFX5130-48CM-D-AFO — Environmental Specifications | |
| Operating Temperature | 32°F through 104°F /0° through 40°C |
| Storage Temperature | -40°F through 158°F /-40° through 70°C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in./ 76.2 cm |
| QFX5130-48CM-D-AFO — Built-in Network Ports | |
| SFP-DD Port Count | 48 |
| SFP-DD Port Channelization | Y |
| SFP-DD Port – MACsec Support? | Y |
| QSFP-DD Port Count | 8 |
| QSFP-DD Port Channelization | Y |
| QSFP-DD Port – MACsec Support? | Y |
| QFX5130-48CM-D-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP-DD |
| 10 MHz Port | 1 |
| PPS Port | 1 |
| QFX5130-48CM-D-AFO — Performance (Routing/Switching) | |
| Throughput | 16 |
| Throughput (Bidirectional) | 16 |
| Throughput (Unidirectional) | 8 |
| Forwarding Capacity | 2.7E9 |
| Egress VLAN ACL | 2000 |
| Egress Port ACL | 4000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 28671.0 |
| Ingress Port ACL | 14335.0 |
| Ingress Routed ACL | 28671.0 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 72 |
| MAC Addresses Per System (Thousands) | 96000.0 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216.0 |
| Total Packet Buffer | 0.082 |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5130-48CM-D-AFO — Processor | |
| CPU | Intel Ice Lake (4 core) |
| DRAM | 32 |
| QFX5130-48CM-D-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Yes |
| DC PSU Model Number | JPSU-1600W-1UDCAFO |
| DC Max Power Consumption | 587 |
| DC Average Power Consumption | 272 |
| Grounding Cable Lug Type | Panduit LCD6-14A-L |
| QFX5130-48CM-D-AFO — Storage | |
| Storage Size | 200 |
| Storage Type | SSD |
| QFX5130-48CM-D-AFI — Overview | |
| Full Product Name | QFX5130-48CM Switch |
| OS Supported | Junos OS Evolved |
| First OS Release Supported | 23.4R2S1-EVO |
| QFX5130-48CM-D-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in. / 4.3 cm |
| Chassis Width | 17.28 in. / 43.9 cm |
| Chassis Depth | 20.5 in. / 52.1 cm |
| Chassis Weight (As Shipped) | 27 lb /12.24 kg |
| Chassis Model Number | QFX5130-48CM-AFO |
| QFX5130-48CM-D-AFI — Cooling System | |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5130-48C-FANAO |
| Fan Module Count | 6 |
| Fan Module Redundancy | Yes |
| Fan Module Hot-Removable And Hot-Insertable? | Yes |
| QFX5130-48CM-D-AFI — Environmental Specifications | |
| Operating Temperature | 32°F through 104°F /0° through 40°C |
| Storage Temperature | -40°F through 158°F /-40° through 70°C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in./ 76.2 cm |
| QFX5130-48CM-D-AFI — Built-in Network Ports | |
| SFP-DD Port Count | 48 |
| SFP-DD Port Channelization | Y |
| SFP-DD Port – MACsec Support? | Y |
| QSFP-DD Port Count | 8 |
| QSFP-DD Port Channelization | Y |
| QSFP-DD Port – MACsec Support? | Y |
| QFX5130-48CM-D-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP-DD |
| 10 MHz Port | 1 |
| PPS Port | 1 |
| QFX5130-48CM-D-AFI — Performance (Routing/Switching) | |
| Throughput | 16 |
| Throughput (Bidirectional) | 16 |
| Throughput (Unidirectional) | 8 |
| Forwarding Capacity | 2.7E9 |
| Egress VLAN ACL | 2000 |
| Egress Port ACL | 4000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 28671.0 |
| Ingress Port ACL | 14335.0 |
| Ingress Routed ACL | 28671.0 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 72 |
| MAC Addresses Per System (Thousands) | 96000.0 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216.0 |
| Total Packet Buffer | 0.082 |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5130-48CM-D-AFI — Processor | |
| CPU | Intel Ice Lake (4 core) |
| DRAM | 32 |
| QFX5130-48CM-D-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Yes |
| DC PSU Model Number | JPSU-1600W-1UDCAFI |
| DC Max Power Consumption | 587 |
| DC Average Power Consumption | 272 |
| Grounding Cable Lug Type | Panduit LCD6-14A-L |
| QFX5130-48CM-D-AFI — Storage | |
| Storage Size | 200 |
| Storage Type | SSD |
هنوز نظری ثبت نشده است
اولین کسی باشید که برای این محصول نظر میدهد.
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
هنوز سوالی دارید؟