ITMall,Your IT Global Procurement Service Expert
QFX5120-48YM-AFO
Marca Juniper
5Verificato

QFX5120-48YM-AFO

Model (MPN)
QFX5120-48YM-AFO
Condition
Factory Sealed
Original Packaging (NIB)
Esaurito

Key Specifications

Full Product NameQFX5120 Switch
OS SupportedJunos OS
Fixed/Modular Chassis?Fixed
Form Factor1 U
Chassis Height1.72 in / 4.3688 cm
Chassis Width17.36 in / 44.0944 cm
Il tuo prezzo
Call for Pricing
Volume discounts available
Availability Esaurito

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Pagamento sicuro
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Related Products

Panoramica

Product Overview

The Juniper QFX5120-48YM-AFO is a high-performance network component designed for the QFX5120-48YM series.

Key Specifications

Specifiche

QFX5120-48YM-AFI — Overview
Full Product NameQFX5120 Switch
OS SupportedJunos OS
QFX5120-48YM-AFI — Chassis
Fixed/Modular Chassis?Fixed
Form Factor1 U
Chassis Height1.72 in / 4.3688 cm
Chassis Width17.36 in / 44.0944 cm
Chassis Depth20.48 in / 52.0192 cm
Chassis Depth (With FRUs)22.4 in / 56.896 cm
Chassis Weight (Fully Loaded With All Components)24.8 lb / 11.25 kg
QFX5120-48YM-AFI — Chassis Cluster/High Availability/Virtual Chassis
Count of Devices in Virtual Chassis4
QFX5120-48YM-AFI — Cooling System
Airflow DirectionBack-to-front
Airflow Volume126 CFM
AFO/AFI?AFI
Fan Module Model NumberQFX5110-FANAFI
Fan Module Count5
Fan Module Redundancy4+1
Fan Module Hot-Removable And Hot-Insertable?Y
QFX5120-48YM-AFI — Environmental Specifications
Operating Altitude6000 ft / 1828 m
Operating Temperature32° through 104° F / 0° through 40° C
Storage Temperature-40° through 158° F / -40° through 70° C
Relative Humidity, Noncondensing (Operating)5% through 90%
Relative Humidity, Noncondensing (Nonoperating)0% through 95%
Maintenance Clearance30 in / 76.2 cm
QFX5120-48YM-AFI — Built-in Network Ports
SFP28 Port Count48
SFP28 Port – MACsec Support?Y
QSFP28 Port – MACsec Support?Y
QFX5120-48YM-AFI — Other Port Configuration
Console Port Count1
Console Port TypeRJ-45
Management Port Count2
Management Port TypeRJ-45
USB Port Count1
USB Port TypeType A
Uplink Port Count8
Uplink Port TypeQSFP28
Uplink Port – MACsec Support?Y
10 MHz PortY
PPS PortY
QFX5120-48YM-AFI — Performance (Routing/Switching)
Throughput (Bidirectional)4000 Gbps
Throughput (Unidirectional)2000 Gbps
Forwarding Capacity2 Bpps
IPv4 Unicast Host Routes (Thousands)211
IPv4 Unicast Routes Prefixes (RIB) (Thousands)2000
IPv4 Unicast Routes Prefixes (FIB) (Thousands)351
IPv4 Unicast ECMP Paths64
IPv4 Multicast Routes (Thousands)106
IPv6 Unicast Host Routes (Thousands)106
IPv6 Unicast Routes Prefixes (RIB) (Thousands)500
IPv6 Unicast Routes Prefixes (FIB) (Thousands)172
IPv6 Multicast Routes (Thousands)52
ARP Entries (Thousands)64
MSTP Instances64
VSTP Instances509
LAGs Count80
Ports Per LAG64
MAC Addresses Per System (Thousands)288
Maximum Mirroring Sessions4
Traffic Mirroring Destination VLANs4
Traffic Mirroring Destination Ports4
VLAN IDs Count4094
Jumbo Frame9216 bytes
QFX5120-48YM-AFI — Processor
CPU2.9 GHz quad-core Intel
DRAM16 GB
QFX5120-48YM-AFI — Power System
PSU Count2
PSU Redundancy1+1
PSU Airflow DirectionBack-to-front
PSU Hot-Removable And Hot-Insertable?Y
AC PSU Model NumberJPSU-850W-AC-AFI
AC Max Power Consumption460 W
AC Average Power Consumption321 W
QFX5120-48YM-AFI — Storage
Internal Storage Size100 GB
Internal Storage TypeSSD
QFX5120-48YM-AFO — Overview
Full Product NameQFX5120 Switch
OS SupportedJunos OS
QFX5120-48YM-AFO — Chassis
Fixed/Modular Chassis?Fixed
Form Factor1 U
Chassis Height1.72 in / 4.3688 cm
Chassis Width17.36 in / 44.0944 cm
Chassis Depth20.48 in / 52.0192 cm
Chassis Depth (With FRUs)22.4 in / 56.896 cm
Chassis Weight (Fully Loaded With All Components)24.8 lb / 11.25 kg
QFX5120-48YM-AFO — Chassis Cluster/High Availability/Virtual Chassis
Count of Devices in Virtual Chassis4
QFX5120-48YM-AFO — Cooling System
Airflow DirectionFront-to-back
Airflow Volume126 CFM
AFO/AFI?AFO
Fan Module Model NumberQFX5110-FANAFO
Fan Module Count5
Fan Module Redundancy4+1
Fan Module Hot-Removable And Hot-Insertable?Y
QFX5120-48YM-AFO — Environmental Specifications
Operating Altitude6000 ft / 1828 m
Operating Temperature32° through 104° F / 0° through 40° C
Storage Temperature-40° through 158° F / -40° through 70° C
Relative Humidity, Noncondensing (Operating)5% through 90%
Relative Humidity, Noncondensing (Nonoperating)0% through 95%
Maintenance Clearance30 in / 76.2 cm
QFX5120-48YM-AFO — Built-in Network Ports
SFP28 Port Count48
SFP28 Port – MACsec Support?Y
QSFP28 Port – MACsec Support?Y
QFX5120-48YM-AFO — Other Port Configuration
Console Port Count1
Console Port TypeRJ-45
Management Port Count2
Management Port TypeRJ-45
USB Port Count1
USB Port TypeType A
Uplink Port Count8
Uplink Port TypeQSFP28
Uplink Port – MACsec Support?Y
10 MHz PortY
PPS PortY
QFX5120-48YM-AFO — Performance (Routing/Switching)
Throughput (Bidirectional)4000 Gbps
Throughput (Unidirectional)2000 Gbps
Forwarding Capacity2 Bpps
IPv4 Unicast Host Routes (Thousands)211
IPv4 Unicast Routes Prefixes (RIB) (Thousands)2000
IPv4 Unicast Routes Prefixes (FIB) (Thousands)351
IPv4 Unicast ECMP Paths64
IPv4 Multicast Routes (Thousands)106
IPv6 Unicast Host Routes (Thousands)106
IPv6 Unicast Routes Prefixes (RIB) (Thousands)500
IPv6 Unicast Routes Prefixes (FIB) (Thousands)172
IPv6 Multicast Routes (Thousands)52
ARP Entries (Thousands)64
MSTP Instances64
VSTP Instances509
LAGs Count80
Ports Per LAG64
MAC Addresses Per System (Thousands)288
Maximum Mirroring Sessions4
Traffic Mirroring Destination VLANs4
Traffic Mirroring Destination Ports4
VLAN IDs Count4094
Jumbo Frame9216 bytes
QFX5120-48YM-AFO — Processor
CPU2.9 GHz quad-core Intel
DRAM16 GB
QFX5120-48YM-AFO — Power System
PSU Count2
PSU Redundancy1+1
PSU Airflow DirectionFront-to-back
PSU Hot-Removable And Hot-Insertable?Y
AC PSU Model NumberJPSU-850W-AC-AFO
AC Max Power Consumption460 W
AC Average Power Consumption321 W
QFX5120-48YM-AFO — Storage
Internal Storage Size100 GB
Internal Storage TypeSSD
QFX5120-48YM-DC-AFI — Overview
Full Product NameQFX5120 Switch
OS SupportedJunos OS
QFX5120-48YM-DC-AFI — Chassis
Fixed/Modular Chassis?Fixed
Form Factor1 U
Chassis Height1.72 in / 4.3688 cm
Chassis Width17.36 in / 44.0944 cm
Chassis Depth20.48 in / 52.0192 cm
Chassis Depth (With FRUs)22.4 in / 56.896 cm
Chassis Weight (Fully Loaded With All Components)24.8 lb / 11.25 kg
QFX5120-48YM-DC-AFI — Chassis Cluster/High Availability/Virtual Chassis
Count of Devices in Virtual Chassis4
QFX5120-48YM-DC-AFI — Cooling System
Airflow DirectionBack-to-front
Airflow Volume126 CFM
AFO/AFI?AFI
Fan Module Model NumberQFX5110-FANAFI
Fan Module Count5
Fan Module Redundancy4+1
Fan Module Hot-Removable And Hot-Insertable?Y
QFX5120-48YM-DC-AFI — Environmental Specifications
Operating Altitude6000 ft / 1828 m
Operating Temperature32° through 104° F / 0° through 40° C
Storage Temperature-40° through 158° F / -40° through 70° C
Relative Humidity, Noncondensing (Operating)5% through 90%
Relative Humidity, Noncondensing (Nonoperating)0% through 95%
Maintenance Clearance30 in / 76.2 cm
QFX5120-48YM-DC-AFI — Built-in Network Ports
SFP28 Port Count48
SFP28 Port – MACsec Support?Y
QSFP28 Port – MACsec Support?Y
QFX5120-48YM-DC-AFI — Other Port Configuration
Console Port Count1
Console Port TypeRJ-45
Management Port Count2
Management Port TypeRJ-45
USB Port Count1
USB Port TypeType A
Uplink Port Count8
Uplink Port TypeQSFP28
Uplink Port – MACsec Support?Y
10 MHz PortY
PPS PortY
QFX5120-48YM-DC-AFI — Performance (Routing/Switching)
Throughput (Bidirectional)4000 Gbps
Throughput (Unidirectional)2000 Gbps
Forwarding Capacity2 Bpps
IPv4 Unicast Host Routes (Thousands)211
IPv4 Unicast Routes Prefixes (RIB) (Thousands)2000
IPv4 Unicast Routes Prefixes (FIB) (Thousands)351
IPv4 Unicast ECMP Paths64
IPv4 Multicast Routes (Thousands)106
IPv6 Unicast Host Routes (Thousands)106
IPv6 Unicast Routes Prefixes (RIB) (Thousands)500
IPv6 Unicast Routes Prefixes (FIB) (Thousands)172
IPv6 Multicast Routes (Thousands)52
ARP Entries (Thousands)64
MSTP Instances64
VSTP Instances509
LAGs Count80
Ports Per LAG64
MAC Addresses Per System (Thousands)288
Maximum Mirroring Sessions4
Traffic Mirroring Destination VLANs4
Traffic Mirroring Destination Ports4
VLAN IDs Count4094
Jumbo Frame9216 bytes
QFX5120-48YM-DC-AFI — Processor
CPU2.9 GHz quad-core Intel
DRAM16 GB
QFX5120-48YM-DC-AFI — Power System
PSU Count2
PSU Redundancy1+1
PSU Airflow DirectionBack-to-front
PSU Hot-Removable And Hot-Insertable?Y
DC PSU Model NumberJPSU-850W-DC-AFI
DC Max Power Consumption356 W
DC Average Power Consumption333 W
QFX5120-48YM-DC-AFI — Storage
Internal Storage Size100 GB
Internal Storage TypeSSD
QFX5120-48YM-DC-AFO — Overview
Full Product NameQFX5120 Switch
OS SupportedJunos OS
QFX5120-48YM-DC-AFO — Chassis
Fixed/Modular Chassis?Fixed
Form Factor1 U
Chassis Height1.72 in / 4.3688 cm
Chassis Width17.36 in / 44.0944 cm
Chassis Depth20.48 in / 52.0192 cm
Chassis Depth (With FRUs)22.4 in / 56.896 cm
Chassis Weight (Fully Loaded With All Components)24.8 lb / 11.25 kg
QFX5120-48YM-DC-AFO — Chassis Cluster/High Availability/Virtual Chassis
Count of Devices in Virtual Chassis4
QFX5120-48YM-DC-AFO — Cooling System
Airflow DirectionFront-to-back
Airflow Volume126 CFM
AFO/AFI?AFO
Fan Module Model NumberQFX5110-FANAFO
Fan Module Count5
Fan Module Redundancy4+1
Fan Module Hot-Removable And Hot-Insertable?Y
QFX5120-48YM-DC-AFO — Environmental Specifications
Operating Altitude6000 ft / 1828 m
Operating Temperature32° through 104° F / 0° through 40° C
Storage Temperature-40° through 158° F / -40° through 70° C
Relative Humidity, Noncondensing (Operating)5% through 90%
Relative Humidity, Noncondensing (Nonoperating)0% through 95%
Maintenance Clearance30 in / 76.2 cm
QFX5120-48YM-DC-AFO — Built-in Network Ports
SFP28 Port Count48
SFP28 Port – MACsec Support?Y
QSFP28 Port – MACsec Support?Y
QFX5120-48YM-DC-AFO — Other Port Configuration
Console Port Count1
Console Port TypeRJ-45
Management Port Count2
Management Port TypeRJ-45
USB Port Count1
USB Port TypeType A
Uplink Port Count8
Uplink Port TypeQSFP28
Uplink Port – MACsec Support?Y
10 MHz PortY
PPS PortY
QFX5120-48YM-DC-AFO — Performance (Routing/Switching)
Throughput (Bidirectional)4000 Gbps
Throughput (Unidirectional)2000 Gbps
Forwarding Capacity2 Bpps
IPv4 Unicast Host Routes (Thousands)211
IPv4 Unicast Routes Prefixes (RIB) (Thousands)2000
IPv4 Unicast Routes Prefixes (FIB) (Thousands)351
IPv4 Unicast ECMP Paths64
IPv4 Multicast Routes (Thousands)106
IPv6 Unicast Host Routes (Thousands)106
IPv6 Unicast Routes Prefixes (RIB) (Thousands)500
IPv6 Unicast Routes Prefixes (FIB) (Thousands)172
IPv6 Multicast Routes (Thousands)52
ARP Entries (Thousands)64
MSTP Instances64
VSTP Instances509
LAGs Count80
Ports Per LAG64
MAC Addresses Per System (Thousands)288
Maximum Mirroring Sessions4
Traffic Mirroring Destination VLANs4
Traffic Mirroring Destination Ports4
VLAN IDs Count4094
Jumbo Frame9216 bytes
QFX5120-48YM-DC-AFO — Processor
CPU2.9 GHz quad-core Intel
DRAM16 GB
QFX5120-48YM-DC-AFO — Power System
PSU Count2
PSU Redundancy1+1
PSU Airflow DirectionFront-to-back
PSU Hot-Removable And Hot-Insertable?Y
DC PSU Model NumberJPSU-850W-DC-AFO
DC Max Power Consumption356 W
DC Average Power Consumption333 W
QFX5120-48YM-DC-AFO — Storage
Internal Storage Size100 GB
Internal Storage TypeSSD

Recensioni

4/8/2026

The product is firmly packed.

W
William
product.verified_buyer

Garanzia

product.standard_warranty_title

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

product.rma_process_title

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

product.eng_support_title

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

product.logistics_title

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Risorse

product.no_downloads

FAQ

Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

product.still_have_questions