Product Overview
The Juniper QFX5120-48YM-AFO is a high-performance network component designed for the QFX5120-48YM series.

Our CCIE certified engineers can help you verify compatibility.
Global logistics network aiming for same-day handover.
Every unit undergoes rigorous 38-point inspection test.
Trusted by enterprise clients across 6 continents.
Certified network engineers ready to assist with configuration.
The Juniper QFX5120-48YM-AFO is a high-performance network component designed for the QFX5120-48YM series.
| QFX5120-48YM-AFI — Overview | |
|---|---|
| Full Product Name | QFX5120 Switch |
| OS Supported | Junos OS |
| QFX5120-48YM-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Depth (With FRUs) | 22.4 in / 56.896 cm |
| Chassis Weight (Fully Loaded With All Components) | 24.8 lb / 11.25 kg |
| QFX5120-48YM-AFI — Chassis Cluster/High Availability/Virtual Chassis | |
| Count of Devices in Virtual Chassis | 4 |
| QFX5120-48YM-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| Airflow Volume | 126 CFM |
| AFO/AFI? | AFI |
| Fan Module Model Number | QFX5110-FANAFI |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5120-48YM-AFI — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 95% |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5120-48YM-AFI — Built-in Network Ports | |
| SFP28 Port Count | 48 |
| SFP28 Port – MACsec Support? | Y |
| QSFP28 Port – MACsec Support? | Y |
| QFX5120-48YM-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 2 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP28 |
| Uplink Port – MACsec Support? | Y |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5120-48YM-AFI — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 4000 Gbps |
| Throughput (Unidirectional) | 2000 Gbps |
| Forwarding Capacity | 2 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 211 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 351 |
| IPv4 Unicast ECMP Paths | 64 |
| IPv4 Multicast Routes (Thousands) | 106 |
| IPv6 Unicast Host Routes (Thousands) | 106 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 500 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 172 |
| IPv6 Multicast Routes (Thousands) | 52 |
| ARP Entries (Thousands) | 64 |
| MSTP Instances | 64 |
| VSTP Instances | 509 |
| LAGs Count | 80 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 288 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4094 |
| Jumbo Frame | 9216 bytes |
| QFX5120-48YM-AFI — Processor | |
| CPU | 2.9 GHz quad-core Intel |
| DRAM | 16 GB |
| QFX5120-48YM-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JPSU-850W-AC-AFI |
| AC Max Power Consumption | 460 W |
| AC Average Power Consumption | 321 W |
| QFX5120-48YM-AFI — Storage | |
| Internal Storage Size | 100 GB |
| Internal Storage Type | SSD |
| QFX5120-48YM-AFO — Overview | |
| Full Product Name | QFX5120 Switch |
| OS Supported | Junos OS |
| QFX5120-48YM-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Depth (With FRUs) | 22.4 in / 56.896 cm |
| Chassis Weight (Fully Loaded With All Components) | 24.8 lb / 11.25 kg |
| QFX5120-48YM-AFO — Chassis Cluster/High Availability/Virtual Chassis | |
| Count of Devices in Virtual Chassis | 4 |
| QFX5120-48YM-AFO — Cooling System | |
| Airflow Direction | Front-to-back |
| Airflow Volume | 126 CFM |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5110-FANAFO |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5120-48YM-AFO — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 95% |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5120-48YM-AFO — Built-in Network Ports | |
| SFP28 Port Count | 48 |
| SFP28 Port – MACsec Support? | Y |
| QSFP28 Port – MACsec Support? | Y |
| QFX5120-48YM-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 2 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP28 |
| Uplink Port – MACsec Support? | Y |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5120-48YM-AFO — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 4000 Gbps |
| Throughput (Unidirectional) | 2000 Gbps |
| Forwarding Capacity | 2 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 211 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 351 |
| IPv4 Unicast ECMP Paths | 64 |
| IPv4 Multicast Routes (Thousands) | 106 |
| IPv6 Unicast Host Routes (Thousands) | 106 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 500 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 172 |
| IPv6 Multicast Routes (Thousands) | 52 |
| ARP Entries (Thousands) | 64 |
| MSTP Instances | 64 |
| VSTP Instances | 509 |
| LAGs Count | 80 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 288 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4094 |
| Jumbo Frame | 9216 bytes |
| QFX5120-48YM-AFO — Processor | |
| CPU | 2.9 GHz quad-core Intel |
| DRAM | 16 GB |
| QFX5120-48YM-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JPSU-850W-AC-AFO |
| AC Max Power Consumption | 460 W |
| AC Average Power Consumption | 321 W |
| QFX5120-48YM-AFO — Storage | |
| Internal Storage Size | 100 GB |
| Internal Storage Type | SSD |
| QFX5120-48YM-DC-AFI — Overview | |
| Full Product Name | QFX5120 Switch |
| OS Supported | Junos OS |
| QFX5120-48YM-DC-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Depth (With FRUs) | 22.4 in / 56.896 cm |
| Chassis Weight (Fully Loaded With All Components) | 24.8 lb / 11.25 kg |
| QFX5120-48YM-DC-AFI — Chassis Cluster/High Availability/Virtual Chassis | |
| Count of Devices in Virtual Chassis | 4 |
| QFX5120-48YM-DC-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| Airflow Volume | 126 CFM |
| AFO/AFI? | AFI |
| Fan Module Model Number | QFX5110-FANAFI |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5120-48YM-DC-AFI — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 95% |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5120-48YM-DC-AFI — Built-in Network Ports | |
| SFP28 Port Count | 48 |
| SFP28 Port – MACsec Support? | Y |
| QSFP28 Port – MACsec Support? | Y |
| QFX5120-48YM-DC-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 2 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP28 |
| Uplink Port – MACsec Support? | Y |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5120-48YM-DC-AFI — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 4000 Gbps |
| Throughput (Unidirectional) | 2000 Gbps |
| Forwarding Capacity | 2 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 211 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 351 |
| IPv4 Unicast ECMP Paths | 64 |
| IPv4 Multicast Routes (Thousands) | 106 |
| IPv6 Unicast Host Routes (Thousands) | 106 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 500 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 172 |
| IPv6 Multicast Routes (Thousands) | 52 |
| ARP Entries (Thousands) | 64 |
| MSTP Instances | 64 |
| VSTP Instances | 509 |
| LAGs Count | 80 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 288 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4094 |
| Jumbo Frame | 9216 bytes |
| QFX5120-48YM-DC-AFI — Processor | |
| CPU | 2.9 GHz quad-core Intel |
| DRAM | 16 GB |
| QFX5120-48YM-DC-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| PSU Hot-Removable And Hot-Insertable? | Y |
| DC PSU Model Number | JPSU-850W-DC-AFI |
| DC Max Power Consumption | 356 W |
| DC Average Power Consumption | 333 W |
| QFX5120-48YM-DC-AFI — Storage | |
| Internal Storage Size | 100 GB |
| Internal Storage Type | SSD |
| QFX5120-48YM-DC-AFO — Overview | |
| Full Product Name | QFX5120 Switch |
| OS Supported | Junos OS |
| QFX5120-48YM-DC-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Depth (With FRUs) | 22.4 in / 56.896 cm |
| Chassis Weight (Fully Loaded With All Components) | 24.8 lb / 11.25 kg |
| QFX5120-48YM-DC-AFO — Chassis Cluster/High Availability/Virtual Chassis | |
| Count of Devices in Virtual Chassis | 4 |
| QFX5120-48YM-DC-AFO — Cooling System | |
| Airflow Direction | Front-to-back |
| Airflow Volume | 126 CFM |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5110-FANAFO |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5120-48YM-DC-AFO — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 95% |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5120-48YM-DC-AFO — Built-in Network Ports | |
| SFP28 Port Count | 48 |
| SFP28 Port – MACsec Support? | Y |
| QSFP28 Port – MACsec Support? | Y |
| QFX5120-48YM-DC-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 2 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| Uplink Port Count | 8 |
| Uplink Port Type | QSFP28 |
| Uplink Port – MACsec Support? | Y |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5120-48YM-DC-AFO — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 4000 Gbps |
| Throughput (Unidirectional) | 2000 Gbps |
| Forwarding Capacity | 2 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 211 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 351 |
| IPv4 Unicast ECMP Paths | 64 |
| IPv4 Multicast Routes (Thousands) | 106 |
| IPv6 Unicast Host Routes (Thousands) | 106 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 500 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 172 |
| IPv6 Multicast Routes (Thousands) | 52 |
| ARP Entries (Thousands) | 64 |
| MSTP Instances | 64 |
| VSTP Instances | 509 |
| LAGs Count | 80 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 288 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4094 |
| Jumbo Frame | 9216 bytes |
| QFX5120-48YM-DC-AFO — Processor | |
| CPU | 2.9 GHz quad-core Intel |
| DRAM | 16 GB |
| QFX5120-48YM-DC-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| DC PSU Model Number | JPSU-850W-DC-AFO |
| DC Max Power Consumption | 356 W |
| DC Average Power Consumption | 333 W |
| QFX5120-48YM-DC-AFO — Storage | |
| Internal Storage Size | 100 GB |
| Internal Storage Type | SSD |
The product is firmly packed.
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
product.still_have_questions