Cisco Nexus 3016 Platform Overview

The Cisco Nexus 3016 is a fixed 1RU data center switch with 16 QSFP+ ports that support native 40 Gigabit Ethernet or four 10 Gigabit Ethernet connections per port. It provides line-rate Layer 2 and Layer 3 switching for low-latency environments, including financial colocation workloads, and can also aggregate copied traffic for monitoring with Cisco Nexus Data Broker.

Cisco Nexus 3000 Series Data Center Switch Isometric View
Cisco Nexus 3000 Series Switch

The Nexus 3000 family materials identify the Nexus 3016 and a Cisco Nexus 3132C-Z datasheet. The available technical detail here supports a close hardware and ordering guide to the Nexus 3016; a like-for-like specification comparison for the other model is not included.

Cisco Nexus 3000 Series Model Comparison Matrix

The source identifies the Nexus 3132C-Z as a sibling model but supplies no technical specifications for it. Its figures are therefore not presented as a comparison. The Nexus 3016 values below describe the verified platform baseline.

Model / Appliance Form Factor Port Density & Speed Switching / Forwarding Capacity Latency Profile Best For
Nexus 3016 (N3K-C3016Q-40GE) 1RU fixed 16 QSFP+; native 40 Gigabit Ethernet or 4 x 10 Gigabit Ethernet per port 1.28 Tbps; 950 mpps Ultra-low nominal latency; numeric latency value — Low-latency Layer 2/3 data center switching and traffic monitoring aggregation
Nexus 3132C-Z — — — — —

Cisco Nexus 3016 Architecture and Port Density

The Nexus 3016 combines fixed QSFP+ interfaces with redundant power supplies and redundant fans in a compact chassis. Its ports can run as native 40 Gigabit Ethernet interfaces or be configured for four 10 Gigabit Ethernet connections, allowing the switch to serve either 40G links or 10G fan-out requirements. It also has two 10/100/1000-Mbps management ports, an RS-232 serial console port, and a USB port.

For colocation and other latency-sensitive networks, line-rate Layer 2 and Layer 3 forwarding and 40G serialization are central design characteristics. vPC supports Layer 2 multipathing, while 64-way ECMP supports Layer 3 fat-tree designs. Advanced buffer monitoring reports utilization per port and queue, helping operators observe traffic bursts.

Interface or hardware element Quantity and specification
QSFP+ data ports 16; native 40 Gigabit Ethernet or 4 x 10 Gigabit Ethernet per port
Management ports 2 x 10/100/1000 Mbps
Serial console 1 x RS-232
USB 1 port
Power supplies 2 redundant power supplies
Cooling 1 fan tray with redundant fans

Cisco Nexus 3016 Performance and NX-OS Features

The Cisco Nexus 3016 provides line-rate Layer 2 and Layer 3 forwarding across its ports. Its NX-OS feature set includes switching, routing, multicast, quality-of-service, security, management, and monitoring functions. The system default software provides Layer 2 features; Layer 3 routing options are associated with the applicable licenses.

Specification Value
Switching capacity 1.28 Tbps
Forwarding rate 950 mpps
Forwarding behavior Line-rate Layer 2 and Layer 3 on all ports
Maximum transmission unit Up to 9216 bytes
MAC address table 128,000
VLANs 4096
Spanning-tree instances RSTP: 512; MSTP: 64
ACL entries 2000 ingress; 1000 egress
Routing table 16,000 prefixes and 16,000 host entries; 8000 multicast routes
EtherChannels 64 with vPC
Ports per EtherChannel 16
Shared buffer 9 MB
Boot flash memory 2 GB

The platform includes POAP for touchless provisioning, EEM and Python scripting for automation, Ethanalyzer for control-plane packet analysis, and PTP (IEEE 1588) boundary clock support. Routing protocols listed for the platform include BGP, OSPF, EIGRP, and RIPv2. Multicast features include PIM-SM, SSM, and MSDP. Confirm the required license tier against the intended routing feature set before ordering.

Cisco Nexus 3016 Physical, Power, and Environmental Specifications

Plan rack placement around the chassis dimensions, airflow direction, power input, and cooling arrangement. The fan tray is hot-swappable and must be replaced within one minute. Reversed airflow is supported with AC power supplies only; forward airflow is supported with AC and DC power supplies.

Specification Value
Dimensions (height x width x depth) 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm)
Weight 20.5 lb (9.3 kg)
Operating temperature 32 to 104°F (0 to 40°C)
Storage temperature -40 to 158°F (-40 to 70°C)
Operating relative humidity 10 to 85% noncondensing; up to 5 days at maximum humidity
Storage relative humidity 5 to 95% noncondensing
Altitude 0 to 10,000 ft (0 to 3000m)
Input frequency 50 to 60 Hz
AC input 100 to 240 VAC
DC input -40 to -72 VDC; maximum current 33A
Typical operating power 172 W with Twinax at 100% load and 2 PSUs; 174 W with short-reach optics at 100% load and 2 PSUs
Maximum power 227 W
Power supply efficiency 89 to 91% at 220V; DC PSU efficiency 85 to 88%
Typical heat dissipation 587 BTU/hr with Twinax at 100% load and 2 PSUs; 594 BTU/hr with SR4 optics at 100% load and 2 PSUs
Maximum heat dissipation 775 BTU/hr
Measured sound power 59.7 dBA at 40% fan duty cycle; 66.4 dBA at 60%; 71.0 dBA at 100%
Airflow Forward: port-side exhaust. Reversed: port-side intake.

Cisco Nexus 3016 Optics and Cabling Options

The QSFP+ interfaces support fiber and copper cabling in the two operating modes. The listed 40G SR4 transceiver uses an MPO connector. The listed copper splitter cables connect a QSFP interface to four SFP10G connections. Confirm the specific cable or optic selection against the required link design and endpoints.

Part number Description
QSFP-40G-SR4 40GBASE-SR4 QSFP Transceiver Module with MPO Connector
QSFP-H40G-CU1M 40GBASE-CR4 Passive Copper Cable, 1m
QSFP-H40G-CU3M 40GBASE-CR4 Passive Copper Cable, 3m
QSFP-H40G-CU5M 40GBASE-CR4 Passive Copper Cable, 5m
QSFP-4SFP10G-CU1M QSFP to 4xSFP10G Passive Copper Splitter Cable, 1m
QSFP-4SFP10G-CU3M QSFP to 4xSFP10G Passive Copper Splitter Cable, 3m
QSFP-4SFP10G-CU5M QSFP to 4xSFP10G Passive Copper Splitter Cable, 5m

Cisco Nexus 3016 Licensing and Software Selection

The system default software includes Layer 2 capabilities without a license. The Base license enables listed Layer 3 functions, while the LAN Enterprise license adds advanced routing capabilities and requires the Base license. The Nexus Data Broker license applies to tap and SPAN aggregation functions; the product information states that only the Base license is needed for that feature.

License or software option Part number Function or requirement
System default — Layer 2 feature set; no license required
Layer 3 Base license N3K-BAS1K9 Layer 3 routing and multicast features
Layer 3 LAN Enterprise license N3K-LAN1K9 Advanced Layer 3 routing; requires N3K-BAS1K9
Nexus Data Broker license NDB-FX-SWT-K9 Tap and SPAN aggregation functions with Cisco Nexus Data Broker; Base license is needed

The Base license feature list includes inter-VLAN routing, static routes, RIPv2, OSPFv2 limited to 256 routes, EIGRP stub, HSRP, VRRP, ACLs, and multicast functions. The LAN Enterprise tier lists OSPFv2, EIGRP, BGP, and VRF-lite. Cisco NX-OS Release 5.0 and later is identified as supported for Nexus 3000 Series switches.

Cisco Nexus 3016 Ordering and Installed-Base Planning

The following ordering matrix groups the chassis, airflow and power options, bundled configurations, and spares for maintenance planning. Match airflow direction across the chassis cooling and power configuration when selecting components.

Category Part number Description
Chassis N3K-C3016Q-40GE Nexus 3016, 16 QSFP+ ports, 1RU switch
Fan module N3K-C3064-FAN Nexus 3064 Fan Module, Forward airflow (port side exhaust)
Fan module N3K-C3064-FAN-B Nexus 3064 Fan Module, Reversed airflow (port side intake)
Power supply N2200-PAC-400W N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust)
N2200-PAC-400W-B N2K/3K 400W AC Power Supply, Reversed airflow (port side intake)
N2200-PDC-400W N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust)
N3K-PDC-350W-B N3K Series 350W DC Power Supply, Reversed airflow (port side intake)
Bundle N3K-C3016-FA-L3 Nexus 3016, AC, Forward Airflow (port side exhaust), Base and LAN Ent Lic Bundle
N3K-C3016-BA-L3 Nexus 3016, AC, Reversed Airflow (port side intake), Base and LAN Ent Lic Bundle
N3K-C3016-FD-L3 Nexus 3016, DC, Forward Airflow (port side exhaust), Base and LAN Ent Lic Bundle
N3K-C3016-BD-L3 Nexus 3016, DC, Reversed Airflow (port side intake), Base and LAN Ent Lic Bundle
Spare fan N3K-C3064-FAN= Nexus 3064 Fan Module, Forward airflow (port side exhaust), Spare
Spare fan N3K-C3064-FAN-B= Nexus 3064 Fan Module, Reversed airflow (port side intake), Spare
Spare power supply N2000-PAC-400W= N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust), Spare
N2000-PAC-400W-B= N2K/3K 400W AC Power Supply, Reversed airflow (port side intake), Spare
N2200-PDC-400W= N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust), Spare
N3K-PDC-350W-B= N3K Series 350W DC Power Supply, Reversed airflow (port side intake), Spare
Accessory spare N3K-C3064-ACC-KIT= Nexus 3064PQ Accessory Kit

For an existing deployment, validate the installed airflow direction, power input type, NX-OS release, and enabled license features before replacing a component or adding a spare. Cisco lists services including SMARTnet for technical support and Smart Call Home capabilities; confirm service eligibility for the specific asset through the applicable support channel.