Cisco Nexus 3016 Platform Overview
The Cisco Nexus 3016 is a fixed 1RU data center switch with 16 QSFP+ ports that support native 40 Gigabit Ethernet or four 10 Gigabit Ethernet connections per port. It provides line-rate Layer 2 and Layer 3 switching for low-latency environments, including financial colocation workloads, and can also aggregate copied traffic for monitoring with Cisco Nexus Data Broker.

The Nexus 3000 family materials identify the Nexus 3016 and a Cisco Nexus 3132C-Z datasheet. The available technical detail here supports a close hardware and ordering guide to the Nexus 3016; a like-for-like specification comparison for the other model is not included.
Cisco Nexus 3000 Series Model Comparison Matrix
The source identifies the Nexus 3132C-Z as a sibling model but supplies no technical specifications for it. Its figures are therefore not presented as a comparison. The Nexus 3016 values below describe the verified platform baseline.
| Model / Appliance | Form Factor | Port Density & Speed | Switching / Forwarding Capacity | Latency Profile | Best For |
|---|---|---|---|---|---|
| Nexus 3016 (N3K-C3016Q-40GE) | 1RU fixed | 16 QSFP+; native 40 Gigabit Ethernet or 4 x 10 Gigabit Ethernet per port | 1.28 Tbps; 950 mpps | Ultra-low nominal latency; numeric latency value — | Low-latency Layer 2/3 data center switching and traffic monitoring aggregation |
| Nexus 3132C-Z | — | — | — | — | — |
Cisco Nexus 3016 Architecture and Port Density
The Nexus 3016 combines fixed QSFP+ interfaces with redundant power supplies and redundant fans in a compact chassis. Its ports can run as native 40 Gigabit Ethernet interfaces or be configured for four 10 Gigabit Ethernet connections, allowing the switch to serve either 40G links or 10G fan-out requirements. It also has two 10/100/1000-Mbps management ports, an RS-232 serial console port, and a USB port.
For colocation and other latency-sensitive networks, line-rate Layer 2 and Layer 3 forwarding and 40G serialization are central design characteristics. vPC supports Layer 2 multipathing, while 64-way ECMP supports Layer 3 fat-tree designs. Advanced buffer monitoring reports utilization per port and queue, helping operators observe traffic bursts.
| Interface or hardware element | Quantity and specification |
|---|---|
| QSFP+ data ports | 16; native 40 Gigabit Ethernet or 4 x 10 Gigabit Ethernet per port |
| Management ports | 2 x 10/100/1000 Mbps |
| Serial console | 1 x RS-232 |
| USB | 1 port |
| Power supplies | 2 redundant power supplies |
| Cooling | 1 fan tray with redundant fans |
Cisco Nexus 3016 Performance and NX-OS Features
The Cisco Nexus 3016 provides line-rate Layer 2 and Layer 3 forwarding across its ports. Its NX-OS feature set includes switching, routing, multicast, quality-of-service, security, management, and monitoring functions. The system default software provides Layer 2 features; Layer 3 routing options are associated with the applicable licenses.
| Specification | Value |
|---|---|
| Switching capacity | 1.28 Tbps |
| Forwarding rate | 950 mpps |
| Forwarding behavior | Line-rate Layer 2 and Layer 3 on all ports |
| Maximum transmission unit | Up to 9216 bytes |
| MAC address table | 128,000 |
| VLANs | 4096 |
| Spanning-tree instances | RSTP: 512; MSTP: 64 |
| ACL entries | 2000 ingress; 1000 egress |
| Routing table | 16,000 prefixes and 16,000 host entries; 8000 multicast routes |
| EtherChannels | 64 with vPC |
| Ports per EtherChannel | 16 |
| Shared buffer | 9 MB |
| Boot flash memory | 2 GB |
The platform includes POAP for touchless provisioning, EEM and Python scripting for automation, Ethanalyzer for control-plane packet analysis, and PTP (IEEE 1588) boundary clock support. Routing protocols listed for the platform include BGP, OSPF, EIGRP, and RIPv2. Multicast features include PIM-SM, SSM, and MSDP. Confirm the required license tier against the intended routing feature set before ordering.
Cisco Nexus 3016 Physical, Power, and Environmental Specifications
Plan rack placement around the chassis dimensions, airflow direction, power input, and cooling arrangement. The fan tray is hot-swappable and must be replaced within one minute. Reversed airflow is supported with AC power supplies only; forward airflow is supported with AC and DC power supplies.
| Specification | Value |
|---|---|
| Dimensions (height x width x depth) | 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
| Weight | 20.5 lb (9.3 kg) |
| Operating temperature | 32 to 104°F (0 to 40°C) |
| Storage temperature | -40 to 158°F (-40 to 70°C) |
| Operating relative humidity | 10 to 85% noncondensing; up to 5 days at maximum humidity |
| Storage relative humidity | 5 to 95% noncondensing |
| Altitude | 0 to 10,000 ft (0 to 3000m) |
| Input frequency | 50 to 60 Hz |
| AC input | 100 to 240 VAC |
| DC input | -40 to -72 VDC; maximum current 33A |
| Typical operating power | 172 W with Twinax at 100% load and 2 PSUs; 174 W with short-reach optics at 100% load and 2 PSUs |
| Maximum power | 227 W |
| Power supply efficiency | 89 to 91% at 220V; DC PSU efficiency 85 to 88% |
| Typical heat dissipation | 587 BTU/hr with Twinax at 100% load and 2 PSUs; 594 BTU/hr with SR4 optics at 100% load and 2 PSUs |
| Maximum heat dissipation | 775 BTU/hr |
| Measured sound power | 59.7 dBA at 40% fan duty cycle; 66.4 dBA at 60%; 71.0 dBA at 100% |
| Airflow | Forward: port-side exhaust. Reversed: port-side intake. |
Cisco Nexus 3016 Optics and Cabling Options
The QSFP+ interfaces support fiber and copper cabling in the two operating modes. The listed 40G SR4 transceiver uses an MPO connector. The listed copper splitter cables connect a QSFP interface to four SFP10G connections. Confirm the specific cable or optic selection against the required link design and endpoints.
| Part number | Description |
|---|---|
| QSFP-40G-SR4 | 40GBASE-SR4 QSFP Transceiver Module with MPO Connector |
| QSFP-H40G-CU1M | 40GBASE-CR4 Passive Copper Cable, 1m |
| QSFP-H40G-CU3M | 40GBASE-CR4 Passive Copper Cable, 3m |
| QSFP-H40G-CU5M | 40GBASE-CR4 Passive Copper Cable, 5m |
| QSFP-4SFP10G-CU1M | QSFP to 4xSFP10G Passive Copper Splitter Cable, 1m |
| QSFP-4SFP10G-CU3M | QSFP to 4xSFP10G Passive Copper Splitter Cable, 3m |
| QSFP-4SFP10G-CU5M | QSFP to 4xSFP10G Passive Copper Splitter Cable, 5m |
Cisco Nexus 3016 Licensing and Software Selection
The system default software includes Layer 2 capabilities without a license. The Base license enables listed Layer 3 functions, while the LAN Enterprise license adds advanced routing capabilities and requires the Base license. The Nexus Data Broker license applies to tap and SPAN aggregation functions; the product information states that only the Base license is needed for that feature.
| License or software option | Part number | Function or requirement |
|---|---|---|
| System default | — | Layer 2 feature set; no license required |
| Layer 3 Base license | N3K-BAS1K9 | Layer 3 routing and multicast features |
| Layer 3 LAN Enterprise license | N3K-LAN1K9 | Advanced Layer 3 routing; requires N3K-BAS1K9 |
| Nexus Data Broker license | NDB-FX-SWT-K9 | Tap and SPAN aggregation functions with Cisco Nexus Data Broker; Base license is needed |
The Base license feature list includes inter-VLAN routing, static routes, RIPv2, OSPFv2 limited to 256 routes, EIGRP stub, HSRP, VRRP, ACLs, and multicast functions. The LAN Enterprise tier lists OSPFv2, EIGRP, BGP, and VRF-lite. Cisco NX-OS Release 5.0 and later is identified as supported for Nexus 3000 Series switches.
Cisco Nexus 3016 Ordering and Installed-Base Planning
The following ordering matrix groups the chassis, airflow and power options, bundled configurations, and spares for maintenance planning. Match airflow direction across the chassis cooling and power configuration when selecting components.
| Category | Part number | Description |
|---|---|---|
| Chassis | N3K-C3016Q-40GE | Nexus 3016, 16 QSFP+ ports, 1RU switch |
| Fan module | N3K-C3064-FAN | Nexus 3064 Fan Module, Forward airflow (port side exhaust) |
| Fan module | N3K-C3064-FAN-B | Nexus 3064 Fan Module, Reversed airflow (port side intake) |
| Power supply | N2200-PAC-400W | N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust) |
| N2200-PAC-400W-B | N2K/3K 400W AC Power Supply, Reversed airflow (port side intake) | |
| N2200-PDC-400W | N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust) | |
| N3K-PDC-350W-B | N3K Series 350W DC Power Supply, Reversed airflow (port side intake) | |
| Bundle | N3K-C3016-FA-L3 | Nexus 3016, AC, Forward Airflow (port side exhaust), Base and LAN Ent Lic Bundle |
| N3K-C3016-BA-L3 | Nexus 3016, AC, Reversed Airflow (port side intake), Base and LAN Ent Lic Bundle | |
| N3K-C3016-FD-L3 | Nexus 3016, DC, Forward Airflow (port side exhaust), Base and LAN Ent Lic Bundle | |
| N3K-C3016-BD-L3 | Nexus 3016, DC, Reversed Airflow (port side intake), Base and LAN Ent Lic Bundle | |
| Spare fan | N3K-C3064-FAN= | Nexus 3064 Fan Module, Forward airflow (port side exhaust), Spare |
| Spare fan | N3K-C3064-FAN-B= | Nexus 3064 Fan Module, Reversed airflow (port side intake), Spare |
| Spare power supply | N2000-PAC-400W= | N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust), Spare |
| N2000-PAC-400W-B= | N2K/3K 400W AC Power Supply, Reversed airflow (port side intake), Spare | |
| N2200-PDC-400W= | N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust), Spare | |
| N3K-PDC-350W-B= | N3K Series 350W DC Power Supply, Reversed airflow (port side intake), Spare | |
| Accessory spare | N3K-C3064-ACC-KIT= | Nexus 3064PQ Accessory Kit |
For an existing deployment, validate the installed airflow direction, power input type, NX-OS release, and enabled license features before replacing a component or adding a spare. Cisco lists services including SMARTnet for technical support and Smart Call Home capabilities; confirm service eligibility for the specific asset through the applicable support channel.