| Ordering Information |
|---|
| Part Number A907-FAN-E | Fan tray with filter slot (NCS 4216 System Components) |
| NCS4206-SA | NCS 4206 shelf assembly (6 slots, 3 RU) |
| NCS4206-SA= | NCS 4206 shelf assembly (6 slots, 3 RU), spare |
| NCS4206-DOOR | NCS 4206 door and ancillary |
| A903-FAN-H | High-performance fan tray |
| A903-F2B-AIR | Front-to-back airflow deflector |
| NCS4216-SA | NCS 4216 shelf assembly (16 slots, 7 RU) |
| NCS4216-SA= | NCS 4216 shelf assembly (16 slots, 7 RU), spare |
| NCS4216-DOOR | NCS 4216 door and ancillary |
| A907-F2B-AIR | Front-to-back airflow deflector |
| NCS4216-F2B-SA | NCS 4216 F2B Shelf Assembly (16 slots-14 RU) |
| NCS4216-F2B-SA= | NCS 4216 F2B Shelf Assembly (16 slots-14 RU), Spare |
| NCS4216-F2B-DOOR | NCS 4216 F2B Door and Ancillary |
| NCS4216-F2B-FAN | NCS 4216 F2B Top/Bottom Fan Tray Kit |
| NCS4216-PWR-FAN | NCS 4216 F2B Power Supply Fan Tray |
| A900-PWR1200-A | ASR 900 1200W AC power supply |
| A900-PWR1200-A= | ASR 900 1200W AC power supply, spare |
| A900-PWR1200-D | ASR 900 1200W DC power supply |
| A900-PWR1200-D= | ASR 900 1200W DC power supply, spare |
| A900-PWR900-D2 | ASR 900 900W DC power supply with dual feed |
| A900-PWR900-D2= | ASR 900 900W DC power supply with dual feed, spare |
| A900-PWR-BLANK | ASR 900 power supply blank cover |
| A900-RSPA-BLANK= | ASR 900 route switch processor type A blank cover, spare |
| A900-IMA-BLANK= | ASR 900 interface module type A blank cover, spare |
| A900-IMA-FILLER= | ASR 900 Interface Module Filler Cover, Spare |
| A900-OPT-GUIDE-H= | ASR 900 optical guide for horizontal fiber routing support |
| A900-ROPT-GUIDE-H= | ASR 900 RSP optical guide for horizontal fiber routing support |
| System Specifications - NCS 4216 |
|---|
| Physical specifications Height | 12.22 in. (310.38 mm), 7 RU |
| Width | 17.44 in. (443 mm) |
| Depth | 9.22 in. (234.2 mm) |
| Weight fully loaded | 69.32 lb. (31.4 kg) with two RSPs, two DC power supplies, and loaded with a typical combination of interface module cards |
| Weight empty chassis | 34.9 lb (15.9 kg) |
| Shipment weight | 58 lb. |
| Rack mounts | ETSI rack mount kit, 19 in. rack mount kit, 23 in. rack mount kit |
| Interface modules | 16 interface module slots |
| Route switch processors | 2 RSP slots |
| Power supplies | 3 power supply slots |
| Fan tray | 1 fan tray with fan redundancy, 4 dry contact input alarms on the fan tray |
| Airflow | Side-to-side airflow; inlet on the right side, outlet on the left side when looking from the front, Front-to-back airflow (requires optional airflow deflectors installed) |
| Power supplies details | Up to 3 power supplies (AC or DC), Modules operate in load-share mode, System can operate on a single power supply and supports mixing of AC and DC power supplies in a single chassis |
| Chassis MTBF at 40°C | 6,620,840 hours |
| Fan tray MTBF at 40°C | 284,880 hours |
| Power Specifications |
|---|
| Power consumption NCS4216 | Maximum input power 1350W (including loss), equivalent to 4600 BTU per hr; NCS4216-F2B 2044W (including loss) plus 750W for fan trays |
| AC input voltage and frequency | Voltage range: 85 to 264 VAC, nominal 115 to 230 VAC; Frequency range: 47 to 63 Hz, nominal 50 to 60 Hz |
| AC power supply MTBF at 40°C | 300,000 hours |
| DC input voltage | For 900W DC: –40V to –72V DC, nominal –48V/–60V DC; For 1200W DC: –40V to –72V DC, nominal –48V/–60V DC; NCS4216-F2B fan tray: –40V to –72V DC, nominal –48V/–60V DC |
| DC power supply MTBF at 40°C A900-PWR900-D2 | 2,133,420 hours |
| DC power supply MTBF at 40°C A900-PWR1200-D | 1,462,100 hours |
| Power supply shipment packaging size (LxWxH) | 15.44 in. x 9.44 in. x 4.31 in. |
| Power supply shipment weight | 3.6 lb. |
| Environmental Specifications |
|---|
| Operating environment NCS4216 DC/AC | –40 to 65˚C operating temperature (with 900W or 1200W power supplies) |
| Operating altitude full temp | –60 to 1800m |
| Operating altitude up to 40˚C | Up to 4000m |
| Outside plant | Requires sealed enclosure like IP65 cabinets with heat exchanger per Telecordia GR487 |
| Relative humidity | 5 to 95%, noncondensing |
| Acoustic noise | NEBS GR-63-Core Issue 4, 78 dB at 27˚C per ANSI S12.10/ISO 7779 |
| Storage environment | Temperature: –40 to 70˚C; altitude: 15,000 ft. (4570m) |
| Seismic | Zone 4 |
| Hazardous substances | ROHS 6 |
| Safety and Compliance |
|---|
| Safety standards | UL 60950-1 2nd edition, CAN/CSA C22.2 No. 60950-1-07 2nd edition, IEC 60950-1 2nd edition, EN 60950-1 2nd edition, AS/NZS 60950.1:2003 |
| Electromagnetic Emissions | FCC CFR47 Part 15 Class A, EN55022 class A, CISPR22 class A, ICES-003 class A, EN 300 386 class A, VCCI class A, KN22 class A, EN61000-3-2 to EN61000-3-3 |
| Immunity compliance | EN 300 386, EN 61000-6-1, EN 50082-1, CISPR24, EN 55024, KN 24, EN 50121-4, EN/KN 61000-4-2 to EN/KN 61000-4-6, EN/KN 61000-4-8, EN/KN 61000-4-11 |
| NEBS | GR-63-CORE Issue 4, GR-1089-CORE Issue 6, SR-3580 NEBS Level 3 |
| ETSI | ETS/EN 300 119 Part 4, ETS/EN 300 019: Storage Class 1.2, Transportation Class 2.3, In-Use/Operational Class 3.2 |
| Network synchronization | ANSI T1.101, GR-1244-CORE, GR-253-CORE, ITU-T G.703 clause 5, ITU-T G.703 clause 9, ITU-T G.781, ITU-T G.813, ITU-T G.823, ITU-T G.824, ITU-T G.8261/Y.1361, ITU-T G.8262, ITU-T G.8264, ITU-T G.8265.1, ITU-T G.8275.1, ITU-T G.8275.2, IEEE1588-2008 |
| Certifications |
|---|
| Common Criteria | Cisco NCS 4206 System and Cisco NCS 4216 System running Cisco IOS XE Software 3.18 |
| FIPS | FIPS 140 validated cryptographic module, Cisco NCS 4206 System, and Cisco NCS 4216 System running Cisco IOS XE Software 3.18 |
| IEEE 1588-2008 | 1588TM SLAVE (IEEE CONFORMITY ASSESSMENT PROGRAM), IEEE 1588TM Conformity Test Suite for Frequency Synchronization in Telecommunications Networks-Packet Slave Clock, IEEE Std 1588TM-2008 and Recommendation ITU-T G.8265.1 (10/2010) with Amendments 1 (04/2011) and 2 (10/2012) |
| MEF | Carrier Ethernet CE 2.0 |
| TAA | Cisco NCS 4206 System and Cisco NCS 4216 / 4216-F2B Systems running Cisco IOS XE Software 16.10.1 |
| Features and Benefits |
|---|
| Support for TDM and SONET/SDH migration | Cost-effective CEM and OTN over MPLS/FlexLSP/SR |
| Metro Carrier Ethernet aggregation | Layer 2, Layer 3, IP, MPLS for L2/L3 VPN, multicast |
| CEM density | High-density TDM, SONET/SDH, OTN, Carrier Ethernet via MPLS/FlexLSP |
| Packet capabilities | PWE3, H-QoS, IP/MPLS, FlexLSP sub-50ms switchover |
| Operation efficiency | EPN-M for automated operations, provisioning, assurance |
| Flexible platform | Compact form, side-to-side airflow, modular RSPs/PSUs/fans/interfaces |