| License Details |
|---|
| Part Number | S-A9K-NVSAT20-LIC |
| Description | NV Host License for up to 20 nV Clients |
| Features and Benefits |
|---|
| Interface support | Cisco Pluggable interfaces - Provides the capacity to mix and match 10, 25, 40, 100, and 400 Gigabit Ethernet interface types across the ASR 9903 chassis |
| Evolutionary monitoring - Carrier-class OAM | NetFlow, IEEE 802.1ag, IEEE 802.3ah, ITU Y.1731, IP Service-Level Agreement (IP SLA), Virtual Circuit Connectivity Verification (VCCV), ping, and traceroute |
| Timing capability | Hardware-based IEEE 1588, GPS/BITS interfaces, and SyncE support - Delivers timing services over the packet network. Support of PTP Telecom profiles (G.8265.1, G.8275.1, G.8275.2). SyncE on Ethernet ports across the ASR 9903 chassis, support of GPS, and BITS interfaces to provide redundant network synchronization |
| Carrier-grade redundancy | Fully redundant configuration - Support of redundant configuration: two RPs, two fabrics, 4 power supply modules, 4 Fan modules |
| Carrier-class OS | Cisco IOS XR Software (64-bit) - Modular, patchable, scalable, highly available, carrier-core, and edge-proven operating system |
| Chassis Specifications |
|---|
| Physical dimensions (H x W x D); weight | ASR 9903 chassis (including 2 RPs, 4 PSUs, 4 FANs): 5.18 x 17.475 x 30 in.; 81.62 lb (131.57 mm x 443.86 mm x 762 mm; 37 kg) Note: Excluding ejector, the depth is 23.62 in/600 mm |
| Redundancy | Route processor redundancy, Switch fabric redundancy, Power supply redundancy, Fan redundancy, Software redundancy |
| Port density | ASR 9903 chassis with integrated ports: 16 QSFP28 ports capable of 10Gb, 40Gb, and 100Gb Ethernet, 20 SFP+ ports capable of 10Gb Ethernet |
| RP CPU memory | SDRAM DDR4 – 32GB default |
| Rack mounting | 19-in. |
| Airflow | Front to back |
| Power | 1.6 kW DC power module (up to 4 modules), redundancy: 2+2, 1.6 kW AC power module (up to 4 modules), redundancy: AC high line (200-240V): 2+2, AC low line (90-130V): 3+1 Note: Mixing of AC and DC modules is not supported. |
| Ethernet | 10 Gbps IEEE 802.3ae compliant, 40/100-Gbps IEEE 802.3ba compliant, 100 Gigabit Ethernet PHY monitoring, IEEE 802.x flow control, Full-duplex operation, Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets |
| Performance | 10-Gbps line-rate throughput per SFP+ port, 100-Gbps line-rate throughput per QSFP28 port |
| Operating temperature | 41 to 104°F (5 to 40°C) Note: Limitations may apply when using high-power optics |
| Operating humidity (nominal) (relative humidity) | 10 to 85% |
| Storage temperature | –40 to 158°F (–40 to 70°C) |
| Storage (relative humidity) | 5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air |
| Operating altitude | –60 to 1800 m |
| 2T Port Expansion Card Specifications |
|---|
| Port density | 2 Terabit Port Expansion Card: 15 QSFP28 ports capable of 10Gb, 25Gb, 40Gb, and 100Gb Ethernet traffic support. 5 QSFP-DD ports capable of 10Gb, 25Gb, 40Gb, 100Gb, 200Gb, and 400Gb Ethernet traffic support. |
| Ethernet | 40/100-Gbps IEEE 802.3ba compliant, 100 Gigabit Ethernet PHY monitoring, 400-Gbps IEEE 802.3bs compliant, IEEE 802.x flow control, Full-duplex operation, Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets |
| Performance | 100-Gbps line-rate throughput per QSFP28 port, 400-Gbps line-rate throughput per QSFP-DD port |
| Physical dimensions (H x W x D); weight | 2T Port Expansion Card: 1.47 x 16.31 x 15.09 in.; 15.02 lb (37.34 mm x 414.27 mm x 383.28 mm; 6.81 kg) |
| Operating temperature | 41 to 104°F (5 to 40°C) Note: Limitations may apply when using high-power optics |
| Operating humidity (nominal) (relative humidity) | 10 to 85% |
| Storage temperature | –40 to 158°F (–40 to 70°C) |
| Storage (relative humidity) | 5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air |
| Operating altitude | –60 to 1800 m |
| 800G Port Expansion Card Specifications |
|---|
| Port density | 800 Gigabit Port Expansion Card: 32 SFP28 ports capable of 25Gb Ethernet traffic support. 48 SFP+ ports capable of 10Gb Ethernet traffic support. |
| Ethernet | 10-Gbps IEEE 802.3ae compliant, 25-Gbps IEEE 802.3by and IEEE 802.3cc compliant, IEEE 802.x flow control, Full-duplex operation, Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets |
| Performance | 10 Gbps line rate throughput per SFP+ port, 25 Gbps line rate throughput per SFP28 port |
| Physical dimensions (H x W x D); weight | 800G Port Expansion Card: 1.47 x 16.31 x 15.09 in.; 12.84 lb (est.) (37.34 mm x 414.27 mm x 383.28 mm; 5.82 kg) |
| Operating temperature | 41 to 104°F (5 to 40°C) Note: Limitations may apply when using high-power optics |
| Operating humidity (nominal) (relative humidity) | 10 to 85% |
| Storage temperature | –40 to 158°F (–40 to 70°C) |
| Storage (relative humidity) | 5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air |
| Operating altitude | –60 to 1800 m |
| Ordering Information - Flexible Consumption Model |
|---|
| ASR-9903-FC | ASR 9903 1.6T Flexible Consumption Chassis |
| A99-RP-F-FC | ASR 9900 Fixed Chassis Route Processor - Flexible Consumption Model |
| A9903-20HG-PEC-FC | ASR 9903 2T Flexible Consumption Port Expansion Card |
| A9903-8HG-PEC-FC | ASR 9903 800G Flexible Consumption Port Expansion Card |
| PWR-1.6KW-AC | ASR 9900 Fixed Chassis AC Power Supply |
| PWR-1.6KW-DC | ASR 9900 Fixed Chassis DC Power Supply |
| ASR-9903-FAN | ASR 9903 Fan Tray |
| ASR-9903-4P-KIT | ASR 9903 4-Post Mounting Kit for 19-Inch Rack |
| ASR-9903-CAB-MGMT | ASR 9903 Cable Management |
| ASR-9903-FILTER | ASR 9903 Air Filter |
| S-A9K-LI-LIC-FC | ASR 9K Smart License Lawful Intercept – Flexible Consumption Model |
| ESS-ED-100G-RTU1 | Edge Essentials Software RTU License per 100G |
| ADV-ED-100G-RTU1 | Edge Advantage w/o Essentials Software RTU License per 100G |
| ADN-ED-100G-RTU1 | Edge Advantage w/ Essentials Software RTU License per 100G |
| ESS-ED-400G-RTU1 | Edge Essentials Software RTU License per 400G |
| ADV-ED-400G-RTU1 | Edge Advantage w/o Essentials Software RTU License per 400G |
| ADN-ED-400G-RTU1 | Edge Advantage w/ Essentials Software RTU License per 400G |
| ESS-ED-100G-SIA5 | Edge Essentials SIA per 100G 60-120 months |
| ESS-ED-100G-SIA3 | Edge Essentials SIA per 100G 36-59 months |
| ESS-ED-400G-SIA5 | Edge Essentials SIA per 400G 60-120 months |
| ESS-ED-400G-SIA3 | Edge Essentials SIA per 400G 36-59 months |
| ADV-ED-100G-SIA5 | Edge Advantage w/o Essentials SIA per 100G for 60-120 months |
| ADV-ED-100G-SIA3 | Edge Advantage w/o Essentials SIA per 100G for 36-59 months |
| ADV-ED-400G-SIA5 | Edge Advantage w/o Essentials SIA per 400G for 60-120 months |
| ADV-ED-400G-SIA3 | Edge Advantage w/o Essentials SIA per 400G for 36-59 months |
| ADN-ED-100G-SIA5 | Edge Advantage w/ Essentials SIA per 100G for 60-120 months |
| ADN-ED-100G-SIA3 | Edge Advantage w/ Essentials SIA per 100G for 36-59 months |
| ADN-ED-400G-SIA5 | Edge Advantage w/ Essentials SIA per 400G for 60-120 months |
| ADN-ED-400G-SIA3 | Edge Advantage w/ Essentials SIA per 400G for 36-59 months |
| Hardware Ordering - Traditional Business Model |
|---|
| ASR-9903 | ASR 9903 Chassis |
| A99-RP-F | ASR 9900 Fixed Chassis Route Processor |
| A9903-20HG-PEC | ASR 9903 2T Multirate Port Expansion Card |
| A9903-8HG-PEC | ASR 9903 800G Multirate Port Expansion Card |
| PWR-1.6KW-AC | ASR 9900 Fixed Chassis AC Power Supply |
| PWR-1.6KW-DC | ASR 9900 Fixed Chassis DC Power Supply |
| ASR-9903-FAN | ASR 9903 Fan Tray |
| ASR-9903-4P-KIT | ASR 9903 4-Post Mounting Kit for 19-Inch Rack |
| ASR-9903-CAB-MGMT | ASR 9903 Cable Management |
| ASR-9903-FILTER | ASR 9903 Air Filter |
| Feature Licenses - Traditional Business Model |
|---|
| S-A9903-IVRF | ASR 9903 License to Activate up to 8 VRFs for Fixed Ports |
| S-A9903-AIP | ASR 9903 Full-Scale VRF License for Fixed Ports |
| S-A9903-CGN | ASR 9903 License Inline CGv6 Transformation for Fixed Ports |
| S-A9903-20HG-IVRF | ASR 9903 License to Activate up to 8 VRFs for 2T PEC |
| S-A9903-20HG-AIP | ASR 9903 Full-Scale VRF License for 2T PEC |
| S-A9903-20HG-CGN | ASR 9903 License Inline CGv6 Transformation for 2T PEC |
| S-A9K-400G-F-ENBL | ASR 9903 Enablement License for 400G Port on 2T PEC |
| S-A9903-8HG-IVRF | ASR 9903 License to Activate up to 8 VRFs for 800G PEC |
| S-A9903-8HG-AIP | ASR 9903 Full scale VRF License for 800G PEC |
| S-A9903-8HG-CGN | ASR 9903 License In-line CGv6 Transformation for 800G PEC |
| S-A9K-MACSEC-10 | ASR 9000 MACSEC 10G Right to use license |
| S-A9K-MACSEC-40 | ASR 9000 MACSEC 40G Right to use license |
| S-A9K-MACSEC-100 | ASR 9000 MACSEC 100G Right to use license |
| S-A9K-LI-LIC | ASR 9K Smart License Lawful Intercept |
| S-A9K-TUNNEL-ENT | ASR 9K Smart License RTU License for Tunnel Protocols |
| S-A9K-MOBILE-LIC | ASR 9K Smart License Advanced Mobile for System |
| S-A9K-NVSAT1-LIC | NV Host License for 1 nV Client |
| S-A9K-NVSAT5-LIC | NV Host License for up to 5 nV Clients |
| S-A9K-NVSAT20-LIC | NV Host License for up to 20 nV Clients |
| ETSI/EN Standards |
|---|
| Standards | EN300 386: Telecommunications Network Equipment (EMC), ETSI 300 019 Storage Class 1.1, ETSI 300 019 Transportation Class 2.3, ETSI 300 019 Stationary Use Class 3.1, EN55022: Information Technology Equipment (Emissions), EN55024: Information Technology Equipment (Immunity), EN50082-1/EN-61000-6-1: Generic Immunity Standard |
| EMC Standards |
|---|
| Standards | FCC Class A, ICES 003 Class A, AS/NZS 3548 Class A, CISPR 22 (EN55022) Class A, VCCI Class A, BSMI Class A, IEC/EN 61000-3-2: Power Line Harmonics, IEC/EN 61000-3-3: Voltage Fluctuations and Flicker, EN50121-4 Railway Applications Part 4: Emission and immunity of the signaling and telecommunications apparatus |
| Immunity Standards |
|---|
| Standards | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air), IEC/EN-61000-4-3: Radiated Immunity (10V/m), IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal), IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM), IEC/EN-61000-4-5: Signal Ports (1kV), IEC/EN-61000-4-5: Surge DC Port (1kV), IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms), IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m), IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations, EN 50121-4: Railway EMC |
| Safety Standards |
|---|
| Standards | UL/CSA/IEC/EN 60950-1, IEC/EN 60825 Laser Safety, ACA TS001, AS/NZS 60950, FDA: Code of Federal Regulations Laser Safety |
| NEBS Standards |
|---|
| Standards | SR-3580: NEBS Criteria Levels (Level 3), GR-1089-CORE: NEBS EMC and Safety, GR-63-CORE: NEBS Physical Protection |