| Chassis and Router Specifications |
|---|
| Router Chassis | ASR-9010-AC, ASR-9010-DC, ASR-9010-AC-V2, ASR-9010-DC-V2, ASR-9006-AC, ASR-9006-DC, ASR-9006-AC-V2, ASR-9006-DC-V2 |
| Line Cards | A9K-40GE-L, A9K-40GE-B, A9K-40GE-E, A9K-8T/4-L, A9K-8T/4-B, A9K-8T/4-E, A9K-4T-L, A9K-4T-B, A9K-4T-E, A9K-2T20GE-L, A9K-2T20GE-B, A9K-2T20GE-E, A9K-8T-L, A9K-8T-B, A9K-8T-E, A9K-16T/8-B, A9K-SIP-700, A9K-2x100GE-TR, A9K-2x100GE-SE, A9K-24x10GE-TR, A9K-24x10GE-SE, A9K-MOD80-TR, A9K-MOD80-SE, A9K-40GE-TR, A9K-40GE-SE, A9K-4T16GE-TR, A9K-4T16GE-SE |
| Redundancy | No single point of failure, Fabric redundancy, Power supply redundancy, RSP redundancy (both RSPs must be the same version, either A9K-RSP-4G or A9K-RSP-8G), Software redundancy |
| Power Supply | A9K-3KW-AC, A9K-2KW-DC, A9K-1.5KW-DC, PWR-3KW-AC-V2, PWR-2KW-DC-V2 |
| Route Switch Processor Hardware (A9K-RSP-4G and A9K-RSP-8G) |
|---|
| Description | Route switch processor, bidirectional nonblocking fabric, controller, 40-GB hard drive |
| Switch Fabric | Switch fabric |
| CPU | High-performance dual-core processors |
| Internal Memory | 4-GB ECC-protected DRAM for A9K-RSP-4G, 8-GB ECC-protected DRAM for A9K-RSP-8G, Hard disk: 40-GB SAS HDD, 4-GB eUSB Flash memory |
| External Memory | 1-GB Compact Flash |
| Timing | Two independent clock source connections, RJ-45 connector for external timing reference interfaces (BITS/SSU) |
| Management Ports | Two 10/100/1000 BASE-T (RJ-45) LAN management ports, One console port, One auxiliary port |
| Alarms | Alarm outputs: Critical alarm (CR), major alarm (MJ), minor alarm (MN) |
| LEDs | Amber alarm cut-off (ACO) and lamp test, System synchronization alarm (SYNC), Compact Flash activity (CF), Hard Disk Drive (HDD), Fan tray visual indicator (UFAN/LFAN) |
| Physical Specifications |
|---|
| Slot Occupation | Occupies one slot; dual redundant RSPs in 2 slots in Cisco ASR 9010 and ASR 9006 chassis |
| Height | 1.65 in. (4.19 cm) |
| Width | 16 in. (40.64 cm) |
| Depth | 26.53 in (67.38 cm) |
| Weight | 18 lb (8.16 kgs) |
| Power |
|---|
| Power Input | Worldwide ranging AC (200–240V; 50–60 Hz; 16A nominal), Worldwide ranging DC (-48V to –60V; -54V; 50A nominal) |
| Power Consumption Typical | 170W |
| Power Consumption Maximum | 205W |
| Environmental Conditions |
|---|
| Operating Temperature | 32 to 104°F (0 to 40°C) |
| Storage Temperature | -40 to 167°F (-40 to 75°C) |
| Relative Humidity | 10 to 90%, noncondensing |
| Operating Temperature Nominal | 41 to 104ºF (5 to 40ºC) |
| Operating Temperature Short-term | 23 to 131ºF (–5 to 55ºC). Short-term: not more than 96 consecutive hours, total not more than 15 days in 1 year (360 hours total, no more than 15 occurrences) |
| Operating Humidity Nominal | 10 to 85% |
| Operating Humidity Short-term | 5 to 90%. Not to exceed 0.024 kg water per 1 kg of dry air |
| Storage Temperature Detailed | -40 to 158ºF (-40 to 70ºC) |
| Storage Relative Humidity | 5 to 95%. Not to exceed 0.024 kg water per 1 kg of dry air |
| Operating Altitude | –60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Features and Benefits |
|---|
| Highly Scalable Fabric | Designed to support high 1/10/100-Gbps port densities, Provides built-in scalability for investment protection |
| Dual RSP Active-Active | Offers traffic load balancing simultaneously across both fabrics, Offers highly available system where loss of one RSP allows for unimpeded performance per slot |
| Distributed Forwarding Plane | Allows line cards to support independent forwarding for enhanced performance and scale |
| Memory-less Switch Fabric | Ensures transparent nonblocking packet forwarding |
| Virtual Output Queuing and Arbitration | Offers service intelligence with prioritization of traffic (unicast and multicast), Provides efficient congestion management mechanism and avoids problems related to head-of-line blocking |
| Centralized Arbiter | Uses an efficient credit mechanism to help ensure transparent switchover with zero packet loss |
| Clock Source Connections | Two independent clock source connections (BITS and SSU)/DTI, Offers redundant, centralized network synchronization support |
| 40-GB HDD | Allows storing of core dumps and helps reduce the system mean time to repair (MTTR) |
| eUSB Memory Port | Provides access to USB flash memory devices for software image loading and recovery |
| Front-panel LEDs | Provides visual indication of RSP status (active or standby), power management, and activity on Compact Flash and HDD |
| Management Ports | Provides easy access to system console |
| Compliance - NEBS |
|---|
| NEBS Standards | SR-3580: NEBS Criteria Levels (Level 3), GR-1089-CORE: NEBS EMC and Safety, GR-63-CORE: NEBS Physical Protection, VZ.TPR.9205: Verizon TEEER |
| Compliance - ETSI |
|---|
| ETSI Standards | EN300 386: Telecommunications Network Equipment (EMC), ETSI 300 019 Storage Class 1.1, ETSI 300 019 Transportation Class 2.3, ETSI 300 019 Stationary Use Class 3.1, EN55022: Information Technology Equipment (Emissions), EN55024: Information Technology Equipment (Immunity), EN50082-1/EN-61000-6-1: Generic Immunity Standard |
| Compliance - EMC |
|---|
| EMC Standards | FCC Class A, ICES 003 Class A, AS/NZS 3548 Class A, CISPR 22 (EN55022) Class A, VCCI Class A, BSMI Class A, IEC/EN 61000-3-2: Power Line Harmonics, IEC/EN 61000-3-3: Voltage Fluctuations and Flicker, EN 50121-4: Railway EMC |
| Compliance - Immunity |
|---|
| Immunity Standards | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air), IEC/EN-61000-4-3: Radiated Immunity (10V/m), IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal), IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM), IEC/EN-61000-4-5: Signal Ports (1kV), IEC/EN-61000-4-5: Surge DC Port (1kV), IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms), IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m), IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations, EN 50121-4: Railway EMC |
| Compliance - Safety |
|---|
| Safety Standards | UL/CSA/IEC/EN 60950-1, IEC/EN 60825 Laser Safety, ACA TS001, AS/NZS 60950, FDA – Code of Federal Regulations Laser Safety |
| Ordering Information |
|---|
| Route Switch Processor with 4G memory | Cisco IOS-XR Software Release 3.7.2 or later, Part Number: A9K-RSP-4G |
| Route Switch Processor with 4G memory, spare | Cisco IOS-XR Software Release 3.7.2 or later, Part Number: A9K-RSP-4G= |
| Route Switch Processor with 8G memory | Cisco IOS-XR Software Release 4.0.0 or later, Part Number: A9K-RSP-8G |
| Route Switch Processor with 8G memory, spare | Cisco IOS-XR Software Release 4.0.0 or later, Part Number: A9K-RSP-8G= |