| Highly scalable fabric | Designed to support high 1-, 10-, and 100-Gbps port densities, Provides built-in scalability for investment protection |
| Dual RSP to provide an active-active switch fabric | Offers traffic load balancing simultaneously across both fabrics, Offers highly available system where loss of one RSP allows for unimpeded performance per slot |
| Distributed forwarding plane architecture | Allows line cards to support independent forwarding for enhanced performance and scale |
| Control plane extension ports | Allows the redundant pair of chassis to be combined into a single logical entity to provide advantages in management, scalability, and high availability |
| Memoryless switch fabric | Provides transparent nonblocking low-latency packet forwarding |
| Virtual output queuing and arbitration | Offers service intelligence with prioritization of traffic (unicast and multicast), Provides efficient congestion management mechanism and avoids problems related to head-of-line blocking |
| Centralized arbiter | Uses an efficient credit mechanism to help ensure transparent switchover with zero packet loss |
| IEEE 1588 support | Delivers timing services over the packet network efficiently and reliably |
| Two independent clock source connections: BITS and Synchronization Supply Unit (SSU) DTI | Offers redundant, centralized network synchronization support |
| Two 16-GB Solid State Drives (SSDs) | Allows storing of core dumps and helps reduce the system Mean Time To Repair (MTTR) |
| Embedded Universal Series Bus (eUSB) memory port | Provides access to USB flash memory devices for software image loading and recovery |
| Front-panel LEDs | Provides visual indication of RSP status (active or standby), power management, and activity on compact flash and Hard Disk Drive (HDD) |
| Management ports | Provides easy access to system console |
| Hardware Specifications (RSP 440 Models) |
|---|
| A9K-RSP440-TR and A9K-RSP440-SE | Route switch processor, bidirectional nonblocking fabric, controller, two 16-GB SSDs; Switch fabric: High-capacity full-duplex integrated dual-switch fabric, 220 Gbps/slot with single RSP, 440 Gbps/slot with dual RSP; Memory internal: 6-GB ECC-protected DRAM for A9K-RSP440-TR, 12-GB ECC-protected DRAM for A9K-RSP440-SE, Solid state disk: two 16-GB SSDs, 8-GB embedded USB; Memory external: USB 2.0 Type A receptacle; Timing system: Two independent clock source connections, IEEE 1588 support: Copper 10/100-Mbps RJ-45 Ethernet port, GPS, ToD (RS422 and RS232), 1-pps RS422 or 1.0/2.3 50-ohm RF connector, 10MHz in/out 1.0/2.3 50-ohm RF connector; Management: Two 100/1000 BASE-T (RJ-45) LAN management ports, One console port, One auxiliary port, Two 10-GE SFP+ virtualization cluster ports; Alarms: Alarm outputs: Critical Alarm (CR), Major Alarm (MJ), and minor alarm (MN); LEDs: Amber Alarm Cut-Off (ACO) and lamp test, System synchronization alarm (SYNC), Compact Flash activity (CF), Solid State Drive (SSD), Fan tray visual indicator (UFAN/LFAN) |
| A9K-RSP440-LT | Route switch processor, bidirectional nonblocking fabric, controller, one 16-GB SSD; Switch fabric: High-capacity full-duplex integrated dual-switch fabric, 90 Gbps/slot with single RSP license upgradeable to 220 Gbps/slot, 180 Gbps/slot with dual RSP license upgradeable to 440 Gbps/slot; Memory internal: 8 GB ECC-Protected DRAM, Solid state disk: one 16-GB SSDs, 8-GB embedded USB; Memory external: USB 2.0 Type A receptacle; Timing system: Two independent clock source connections, IEEE 1588 support: Copper 10/100-Mbps RJ-45 Ethernet port, GPS, ToD (RS422 and RS232), 1-pps RS422 or 1.0/2.3 50-ohm RF connector, 10-MHz in/out 1.0/2.3 50-ohm RF connector; Management: Two 100/1000 BASE-T (RJ-45) LAN management ports, One console port, One auxiliary port, Two 10-GE SFP+ virtualization cluster ports; Alarms: Alarm outputs: Critical alarm (CR), major alarm (MJ), and minor alarm (MN); LEDs: Amber Alarm Cut-Off (ACO) and lamp test, System synchronization alarm (SYNC), Compact Flash activity (CF), Solid State Drive (SSD), Fan tray visual indicator (UFAN/LFAN) |
| Product Specifications |
|---|
| Chassis | ASR 9904 Chassis, ASR 9010 Chassis, ASR 9006 Chassis |
| Line cards supported with A9K-RSP440-TR and A9K-RSP440-SE | A9K-40GE-SE, A9K-40GE-TR, A9K-4T16GE-SE, A9K-4T16GE-TR, A9K-40GE-L, A9K-40GE-B, A9K-40GE-E, A9K-8T/4-L, A9K-8T/4-B, A9K-8T/4-E, A9K-4T-L, A9K-4T-B A9K-4T-E, A9K-2T20GE-L, A9K-2T20GE-B, A9K-2T20GE-E, A9K-8T-L, A9K-8T-B, A9K-8T-E, A9K-16T/8-B, A9K-1X100GE-SE, A9K-1X100GE-TR, A9K-2X100GE-SE, A9K-2X100GE-TR, A9K-24X10GE-SE, A9K-24X10GE-TR, A9K-36X10GE-SE, A9K-36X10GE-TR |
| Line cards supported with A9K-RSP440-LT | A9K-40GE-SE, A9K-40GE-TR, A9K-4T16GE-SE, A9K-4T16GE-TR, A9K-40GE-L, A9K-40GE-B, A9K-40GE-E, A9K-8T/4-L, A9K-8T/4-B, A9K-8T/4-E, A9K-4T-L, A9K-4T-B A9K-4T-E, A9K-2T20GE-L, A9K-2T20GE-B, A9K-2T20GE-E, A9K-8T-L, A9K-8T-B, A9K-8T-E, A9K-16T/8-B |
| Redundancy | No single point of failure, Fabric redundancy, Power supply redundancy, RSP redundancy, Software redundancy |
| Power supply | A9K-3KW-AC, A9K-2KW-DC, A9K-1.5KW-DC, PWR-3KW-AC-V2, PWR-2KW-DC-V2 |
| Physical specifications | Occupies one slot; dual redundant RSPs in two slots in ASR 9904 chassis, Cisco ASR 9010 and ASR 9006, Height: 1.65 inches (4.2 cm), Width: 16 inches (40.6 cm), Depth: 26.53 inches (67.4 cm), Weight: 20 lb (9 kg) |
| Power input | Worldwide ranging AC (200-240V; 50-60 Hz; 16A nominal), Worldwide ranging DC (-48V to -60V; -54V; 50A nominal) |
| Power consumption | Typical: 170 W, Maximum: 450 W |
| Environmental Specifications |
|---|
| Operating temperature (nominal) | 41 to 104°F (5 to 40°C) |
| Operating temperature (short-term) | 23 to 131°F (-5 to 55°C). Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year (a total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period) |
| Operating humidity (nominal) (relative humidity) | 10 to 85% |
| Operating humidity (short-term) | 5 to 90%. Not to exceed 0.024 kg water or dry air |
| Storage temperature | -40 to 158°F (-40 to 70°C) |
| Storage (relative humidity) | 5 to 95%. Not to exceed 0.024 kg water or dry air |
| Operating altitude | -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Environmental conditions | Operating temperature: 32 to 104°F (0 to 40°C), Storage temperature: -40 to 167°F (-40 to 75°C), Relative humidity: 10 to 90%, noncondensing |
| Compliance - NEBS |
|---|
| Network Equipment Building Standards (NEBS) | SR-3580: NEBS Criteria Levels (Level 3), GR-1089-CORE: NEBS Electromagnetic Compatibility (EMC) and Safety, GR-63-CORE: NEBS Physical Protection, VZ.TPR.9205: Verizon TEEER |
| Compliance - ETSI Standards |
|---|
| ETSI standards | EN300 386: Telecommunications Network Equipment (EMC), ETSI 300 019 Storage Class 1.1, ETSI 300 019 Transportation Class 2.3, ETSI 300 019 Stationary Use Class 3.1, EN55022: Information Technology Equipment (Emissions), EN55024: Information Technology Equipment (Immunity), EN50082-1/EN-61000-6-1: Generic Immunity Standard |
| Compliance - EMC Standards |
|---|
| EMC standards | FCC Class A, ICES 003 Class A, AS/NZS 3548 Class A, CISPR 22 (EN55022) Class A, VCCI Class A, BSMI Class A, IEC/EN 61000-3-2: Power Line Harmonics, IEC/EN 61000-3-3: Voltage Fluctuations and Flicker, EN 50121-4: Railway EMC |
| Compliance - Immunity |
|---|
| Immunity | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air), IEC/EN-61000-4-3: Radiated Immunity (10V/m), IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal), IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM), IEC/EN-61000-4-5: Signal Ports (1kV), IEC/EN-61000-4-5: Surge DC Port (1kV), IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms), IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m), IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations, EN 50121-4: Railway EMC |
| Compliance - Safety |
|---|
| Safety | UL/CSA/IEC/EN 60950-1, IEC/EN 60825 Laser Safety, ACA TS001, AS/NZS 60950, FDA: Code of Federal Regulations Laser Safety |
| Ordering Information |
|---|
| Route Switch Processor optimized for packet transport | Cisco IOS XR Software Release 4.2.0 onwards, A9K-RSP440-TR |
| Route Switch Processor optimized for packet transport, spare | Cisco IOS XR Software Release 4.2.0 onwards, A9K-RSP440-TR= |
| Route Switch Processor optimized for service edge | Cisco IOS XR Software Release 4.2.0 onwards, A9K-RSP440-SE |
| Route Switch Processor optimized for service edge, spare | Cisco IOS-XR Software Release 4.2.0 onwards, A9K-RSP440-SE= |
| Route Switch Processor with 180 G/slot upgradeable to 440G/slot Fabric | Cisco IOS-XR Software Release 5.3.0 onwards, A9K-RSP440-LT |
| Route Switch Processor with 180 G/slot upgradeable to 440G/slot Fabric, spare | Cisco IOS-XR Software Release 5.3.0 onwards, A9K-RSP440-LT= |
| A9K-RSP440-LT Upgrade License to activate 440Gbps/slot | Cisco IOS-XR Software Release 5.3.0 onwards, A9K-RSP440L-ALIC |
| A9K-RSP440-LT Upgrade License to activate 440Gbps/slot, spare | Cisco IOS-XR Software Release 5.3.0 onwards, A9K-RSP440L-ALIC= |
| A9K-RSP440-LT Upgrade Smart License to activate 440Gbps/slot | Cisco IOS-XR Software Release 5.3.0 onwards, S-A9K-RSP440LALIC |
| A9K-RSP440-LT Upgrade Smart License to activate 440Gbps/slot, spare | Cisco IOS-XR Software Release 5.3.0 onwards, L-SA9K-RSP440LLIC= |