| ASR 920 Series Models |
|---|
| ASR-920-12SZ-IM | Cisco ASR920 Series - 12GE and 4-10GE, 1 IM slot |
| ASR-920-24TZ-M | Cisco ASR920 Series – 24GE Fiber and 4-10GE – Modular PSU |
| ASR-920-24SZ-M | Cisco ASR920 Series – 24GE Copper and 4-10GE – Modular PSU |
| ASR-920-24SZ-IM | Cisco ASR920 Series – 24GE and 4-10GE – Modular PSU and IM |
| ASR-920-12SZ-IM-CC | Cisco ASR920 Conformal Coated - 12GE and 4-10GE, 1 IM slot |
| ASR-920-24SZ-M-BB | ASR 920 Major Line Bundle |
| Interface Modules - ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC (Table 1) |
|---|
| A900-IMA8T | ASR 900 8 port 10/100/1000 Ethernet Interface Module, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA8S | ASR 900 8 port SFP Gigabit Ethernet Interface Module, Supported as of Cisco IOS XE Release 3.16.1 |
| A900-IMA8D | ASR 900 8 port RJ48C T1/E1 Interface Module, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA16D | ASR 900 16 port T1/E1 Interface Module, Requires patch panel, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA32D | ASR 900 32 port T1/E1 Interface Module, Requires patch panel, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA1X | ASR 900 1 port 10GE XFP Interface Module, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA2Z | ASR 900 2 port 10GE SFP+/XFP Interface Module, Supported as of Cisco IOS XE Release 3.16.1 |
| A900-IMA8T1Z | ASR900 Combo 8 port 10/100/1000 and 1 port 10GE Interface Module, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA8S1Z | ASR900 Combo 8 SFP GE and 1 port 10GE IM, Supported as of Cisco IOS XE Release 3.16.0S |
| A900-IMA4OS | ASR 900 4 port OC3/STM1 or 1 port OC12/STM4 Interface Module, Supported as of Cisco IOS XE Release 3.18SP |
| Interface Modules - ASR-920-24SZ-IM (Table 2) |
|---|
| A900-IMA8T | ASR 900 8 port 10/100/1000 Ethernet Interface Module, Supported as of Cisco IOS XE Release 3.14.0S |
| A900-IMA1X | ASR 900 1 port 10GE XFP Interface Module, Supported as of Cisco IOS XE Release 3.14.0S |
| A900-IMA2Z | ASR 900 2 port 10GE SFP+/XFP Interface Module, Supported as of Cisco IOS XE Release 3.14.0S |
| A900-IMA8D | ASR 900 8 port RJ48C T1/E1 Interface Module, Supported as of Cisco IOS XE Release 3.14.0S |
| A900-IMA16D | ASR 900 16 port T1/E1 Interface Module, Requires patch panel, Supported as of Cisco IOS XE Release 3.15.0S |
| A900-IMA32D | ASR 900 32 port T1/E1 Interface Module, Requires patch panel, Supported as of Cisco IOS XE Release 3.15.0S |
| A900-IMA4OS | ASR 900 4 port OC3/STM1 or 1 port OC12/STM4 Interface Module, Supported as of Cisco IOS XE Release 3.15.0S |
| A900-IMA8T1Z | ASR900 Combo 8 port 10/100/1000 and 1 port 10GE Interface Module, Supported as of Cisco IOS XE Release 3.15.0S |
| Accessories for 16-Port T1/E1 Module (Table 3) |
|---|
| CABLE-16T1E1 | Cable for 16 Port T1/E1 Interface Module, 12 feet, Supported as of Cisco IOS XE Release 3.15.0S |
| PANEL-16-BNC | Breakout panel with 16 T1/E1 75-ohm BNC ports, Supported as of Cisco IOS XE Release 3.15.0S |
| PANEL-32-RJ48 | Breakout panel with 32 T1/E1 100/120-ohm RJ48 ports, Supported as of Cisco IOS XE Release 3.15.0S |
| Accessories for 32-Port T1/E1 Module (Table 4) |
|---|
| CABLE-32T1E1 | Cable for 32 Port T1/E1 Interface Module, Supported as of Cisco IOS XE Release 3.15.0S |
| PANEL-16-BNC | Breakout panel with 16 T1/E1 75-ohm BNC ports, Supported as of Cisco IOS XE Release 3.15.0S |
| PANEL-32-RJ48 | Breakout panel with 32 T1/E1 100/120-ohm RJ48 ports, Supported as of Cisco IOS XE Release 3.15.0S |
| Hardware Components (Table 5) |
|---|
| ASR-920-24SZ-M-BB | ASR 920 Major Line Bundle |
| ASR-920-FAN-TRAY | Cisco ASR 920 Fan Tray |
| A920-FAN-TRAY-CC | Cisco ASR 920 Fan Tray Conformal Coated |
| ASR-920-FAN-F | ASR920 Fan for Fixed Chassis |
| ASR-920-FAN-M | ASR920 Fan for Modular Chassis |
| A920-PWR400-A | Cisco ASR 920 400W AC PSU |
| A920-PWR400-D | Cisco ASR 920 400W DC PSU |
| ASR-920-PWR-A | ASR920 AC Power Supply |
| ASR-920-PWR-D | ASR920 DC Power Supply |
| ASR920-PWR-BLNK | ASR 920 Power Supply Blank Cover |
| ASR920-PWR-BLANK | ASR920 Power Supply Blank Cover |
| A900-IMA-BLANK | ASR 900 Interface Module Type-A Blank Cover |
| A920-RCKMT-ETSI | ETSI Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-19 | EIA 19” Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-23 | EIA 23” Rack mount Option for the Cisco ASR 920 |
| A920-DRIP-TRAY | ASR 920 Drip Tray - Modular |
| System Specifications (Table 6) |
|---|
| Physical dimensions (H x W x D) | ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC: 1.73 x 17.5 x 11.28 in. (44 x 444.5 x 286.54 mm), 1RU; ASR-920-24SZ-M: 1.72 x 17.5 x 10 in. (43.7 x 444.5 x 255 mm), 1RU; ASR-920-24TZ-M: 1.72 x 17.5 x 10 in. (43.7 x 444.5 x 255 mm), 1RU; ASR-920-24SZ-IM: 2.6 x 17.5 x 10.6 in. (66 x 444.5 x 270 mm), 1.5RU (with IM) |
| Weight (empty chassis) | ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC: 9.25 lb (4.2 kg); ASR-920-24TZ-M: 8.3 lb (3.8 kg); ASR-920-24SZ-M: 8.5 lb (3.9kg); ASR-920-24SZ-IM: 10.3 lb (4.7kg) |
| Weight (with two AC PSU) | ASR-920-12SZ-IM: 13.44 lb (6.1 kg) with IM card; ASR-920-24TZ-M: 10.5 lb (4.8 kg); ASR-920-24SZ-M: 10.5 lb (4.8 kg); ASR-920-24SZ-IM: 14.1 lb (6.4 kg) with IM card |
| Rack mounts | ETSI rack-mount kit, 19-in. rack-mount kit, 23-in. rack-mount kit |
| Air flow | Front-to-Back airflow (ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC, ASR-920-24TZ-M, ASR-920-24SZ-M); Front-to-Back & Side-to-Back airflow (ASR-920-24SZ-IM) |
| Power supplies | 2 power supplies (AC or DC) |
| MTBF (hours) - Chassis | ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC: 407,230; ASR-920-24TZ-M: 582,610; ASR-920-24SZ-M: 546,260; ASR-920-24SZ-IM: 471,530 |
| MTBF (hours) - Components | A920-PWR400-A: 356,809; A920-PWR400-D: 331,879; ASR-920-FAN-TRAY: 2,811,680; ASR-920-FAN-F: 2,581,770; ASR-920-FAN-M: 2,681,720; ASR-920-PWR-A: 1,598,000; ASR-920-PWR-D: 1,129,417 |
| Power Specifications (Table 7) |
|---|
| Power consumption | ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC: Max 150W, Typical: 130W (without PoE); ASR-920-24TZ-M: Max 130W, Typical: 100W; ASR-920-24SZ-M: Max 145W, Typical: 110W; ASR-920-24SZ-IM: Max 180W, Typical: 130W |
| AC input voltage and frequency | Voltage range: 85V AC to 264V AC, nominal 100V AC to 240V AC; Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz |
| DC input voltage | Voltage range: -18 to -32 VDC or -36 to -72 VDC, nominal: -24 VDC/-48 VDC; ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC: -18 VDC to -32 VDC or -40 VDC to -72 VDC nominal -24VDC/-48VDC/-60VDC |
| Environmental Specifications (Table 8) |
|---|
| Operating environment and altitude | -40 to 70ºC, up to 1,000 feet (300m); -40 to 65ºC, up to 6,000 feet (1800m); -40 to 55ºC, up to 13,000 feet (4000m) |
| Relative humidity | 5 to 95 percent, noncondensing |
| Acoustic noise | Acoustic noise peak operation maximum 55 dBA (59 dBA for ASR-920-12SZ-IM/ASR-920-12SZ-IM-CC) sound pressure level, bystander position for rack-mount products at 20ºC operation as measured by ISO 7779 NAIS noise measurement test standard. Acoustic noise peak operation compliant to NEBS GR-63-Core Issue 3 sound power level of 78 dB at 27ºC operation as measured by ANSI S12.10/ISO 7779 NAIS noise measurement test standard. |
| Storage environment | Temperature: -40 to 70ºC altitude: 15,000 feet (4570m) |
| Seismic | Zone 4 |
| Safety and Compliance (Table 9) |
|---|
| Safety | UL 60950-1, 2005; CAN/CSA C22.2 No. 60950-1: 2005; IEC 60950-1, 2005; EN 60950-1, 2005; AS/NZS 60950.1:2005 |
| Electromagnetic Emissions compliance | FCC CFR47 Part 15 Class A; EN55022, class A; CISPR22, class A; ICES-003, class A; EN 300 386, class A; VCCI, class A; KN22, class A; EN61000-3-2 to EN61000-3-3 |
| Immunity compliance | EN 300 386; EN 61000-6-1; EN 50082-1; CISPR24; EN 55024; KN 24; EN 50121-4; EN/KN 61000-4-2 to EN/KN 61000-4-6; EN/KN 61000-4-8; EN/KN 61000-4-11 |
| Power substation system compliance | IEC-61850-3 (2002) (ASR-920-12SZ-IM); IEEE1613 (2009) (ASR-920-12SZ-IM) |
| NEBS | GR-63-CORE; GR-1089-CORE; SR-3580 NEBS Level 4 |
| ETSI | ETS/EN 300 119 Part 4; ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2; ETS/EN 300 753 |
| Network synchronization | ANSI T1.101; GR-1244-CORE; GR-253-CORE; ITU-T G.703 clause 5; ITU-T G.703 clause 9; ITU-T G.781; ITU-T G.813; ITU-T G.823; ITU-T G.824; ITU-T G.8261/Y.1361; ITU-T G.8262; ITU-T G.8264; IEEE1588-2008 |
| Service and Support (Table 10) |
|---|
| Cisco Total Implementation Solutions (TIS) | Project management; Site survey, configuration, and deployment; Installation, test, and cutover; Training; Major moves, adds, and changes; Design review and product staging. Benefits: Supplement existing staff; Help ensure functions meet needs; Mitigate risk |
| Cisco SP Base Support and Service Provider-Based Onsite Support | 24-hour access to software updates; Web access to technical repositories; Telephone support through TAC; Advance replacement of hardware parts. Benefits: Facilitate proactive or expedited problem resolution; Lower total cost of ownership; Reduce network downtime |