| License Information |
|---|
| Model | ASR920-IPSEC |
| Manufacturer | Cisco |
| SKU | ASR920-IPSEC |
| Type | IPsec License |
| Availability | 10 Units In Stock |
| Pricing Status | Special Offer: $189 (Save 92%) |
| Documentation | PDF Datasheet Available |
| Delivery | E-Delivery (Email) |
| Compatibility | Cisco ASR 920 Series Routers |
| Hardware Specifications - 8011-4G24Y4H-I |
|---|
| CPU | 4 cores 2.2GHz |
| Memory | 16GB DRAM |
| Storage | 38GB eMMC |
| Interfaces | 4 ports 40/100G QSFP28 24 ports 1/10/25G SFP28 4 ports 10/100/1000M RJ-45 |
| Performance | Up to 500 Mpps |
| Power supplies | Modular redundant (AC/DC) |
| Fans | Fixed fans with redundancy |
| Airflow | Front to back |
| Operating temperature range | I-Temp –40° to +65°C (–40° to +149°F) |
| Non-operating (storage) temperature | –40° to +70°C (–40° to +158°F) |
| Operating humidity range | 5% to 95% RH, noncondensing |
| Storage (relative) humidity | 5% to 95% at 40°C (104°F) per NEBS GR-63-Core |
| Altitude | Up to 3960 meters (13,000 feet) |
| Power | Worldwide ranging AC (90 to 264V; 50 to 60 Hz) Worldwide ranging DC (–40.8V to –72V) |
| Surge rating* | DC: 2kV CM, 1kV DM AC: 2kV CM, 2kV DM |
| Timing ports | Time of Day (ToD) and Building Integrated Timing Supply (BITS) 8000-TIC: 1 PPS, 10 MHz 8000-TIC-GNSS (internal GNSS PRTC-B module): 1 PPS, 10 MHz, ANT |
| Physical specifications | Height: 43.6 mm (1.72 in.) Width: 439.4 mm (17.3 in.) Depth: 260 mm (10.24 in.) Weight: 4.5 kg (no PSU); 5.7 kg (with 2 PSUs) |
| Mounting options | 19 in., 23 in., ETSI |
| Management interfaces | USB console port USB memory port RS-232 console port 10/100/1000M RJ-45 Ethernet out-of-band management port |
| Hardware Specifications - 8011-32Y8L2H2FH |
|---|
| CPU | 4 cores 2.2GHz |
| Memory | 16GB DRAM |
| Storage | 38GB eMMC |
| Interfaces | 2 ports 400G QSFP56-DD 2 ports 100G QSFP28 8 ports 10/25/50G SFP56 32 ports 1/10/25G SFP28 |
| Performance | Up to 500 Mpps |
| Power supplies | Modular redundant (AC/DC) |
| Fans | Modular fans with redundancy |
| Airflow | Front to back |
| Operating temperature range | C-Temp -5° to +55°C (+32° to +140°F) |
| Non-operating (storage) temperature | -40° to +70°C (-40° to +158°F) |
| Operating humidity range | 5% to 85% RH, noncondensing |
| Storage (relative) humidity | 5% to 95% at 40°C (104°F) for 96 hours as per NEBS GR-63-Core |
| Altitude | Up to 3960 meters (13,000 feet) |
| Power | Worldwide ranging AC (90 to 264V; 50 to 60 Hz) Worldwide ranging DC (–40.8V to –72V) |
| Surge rating* | DC: 2kV CM, 1kV DM AC: 4kV CM, 2kV DM |
| Timing ports | Time of Day (ToD) and Building Integrated Timing Supply (BITS) 8000-TIC: 1 PPS, 10 MHz 8000-TIC-GNSS (internal GNSS PRTC-B module): 1 PPS, 10 MHz, ANT |
| Physical specifications | Height: 43.6 mm (1.72 in.) Width: 439.4 mm (17.3 in.) Depth: 437 mm (17.2 in.) Weight: 6.7 kg (no PSU); 8.8 kg (with 2 PSUs) |
| Mounting options | 19 in., 23 in., ETSI |
| Management interfaces | USB console port USB memory port RS-232 console port 10/100/1000M RJ-45 Ethernet out-of-band management port |
| Key Software Feature Support - Layer 3 |
|---|
| Features | IPv4 and IPv6 unicast routing Virtual Routing and Forwarding (VRF) Open Shortest Path First (OSPF) v2, v3 Intermediate System to Intermediate System (IS-IS) for IPv4 and IPv6 Equal-Cost Multipath (ECMP) Virtual Router Redundancy Protocol (VRRP) Hot Standby Router Protocol (HSRP) Generic Routing Encapsulation (GRE) Policy-Based Routing (PBR) ACL-based Forwarding (ABF) L3 Virtual Private Network (L3VPN) |
| Key Software Feature Support - Layer 2 |
|---|
| Features | Ethernet Flow Point (EFP) Bridge Domains Virtual Private Wire Service (VPWS) Virtual Private LAN Service (VPLS) Ethernet VPN (EVPN) Ethernet VPN Virtual Private Wire Service (EVPN-VPWS) |
| Key Software Feature Support - Integrated Routing and Bridging (IRB) |
|---|
| Features | Bridge Virtual Interfaces (BVI) Ethernet VPN IRB (EVPN-IRB) |
| Key Software Feature Support - MPLS |
|---|
| Features | Multiprotocol Label Switching (MPLS) Label Distribution Protocol (LDP) MPLS Traffic Engineering (MPLS-TE) with RSVP-TE |
| Key Software Feature Support - Segment Routing (SR) |
|---|
| Features | Segment Routing with MPLS data plane (SR-MPLS) Segment Routing with IPv6 data plane (SRv6) Segment Routing Traffic Engineering (SR-TE) Segment Routing Path Computation Element (SR-PCE) Topology-Independent Loop-Free Alternate (TI-LFA) Segment Routing On-Demand Next-Hop (SR-ODN) Segment Routing Performance Management (SR-PM) Segment Routing v6 Performance Management (SRv6-PM) Segment Routing Data Plane Monitoring (SR-DPM) Tree-SID Integrated Performance Monitoring (IPM) |
| Key Software Feature Support - Multicast |
|---|
| Features | IPv4 and IPv6 multicast routing Protocol Independent Multicast – Sparse Mode (PIM-SM) PIM – Source Specific Multicast (PIM-SSM) Internet Group Management Protocol (IGMP) v3 Multicast Listener Discovery (MLD) v2 Multicast Label Distribution Protocol (mLDP) MPLS Point-to-Multipoint Traffic Engineering (MPLS P2MP-TE) Next Generation multicast VPN (NG mVPN) |
| Key Software Feature Support - Quality of Service (QoS) |
|---|
| Features | Virtual Output Queueing (VOQ) with deep packet buffering Class-based 3-level hierarchical QoS Policing, shaping, remarking Multilevel priority queuing Random Early Detection (RED), Weighted RED (WRED) Dual Queue Limit (DQL) |
| Key Software Feature Support - Timing |
|---|
| Features | Enhanced Synchronous Ethernet (eSyncE) Enhanced Ethernet Synchronization Message Channel (eESMC) Internal PRTC-B GNSS receiver (optional HW module) External GNSS receiver IEEE 1588-2008 Precision Time Protocol (PTP): T-GM, T-BC, Virtual Port, A-PTS G.8275.1, G.8275.2, G.8265.1, G.8273.2 Class C Network Time Protocol (NTP) |
| Key Software Feature Support - Security |
|---|
| Features | MACsec and IPsec Control Plane Protection (CoPP) Management Plane Protection (MPP) Local Packet Transport Services (LPTS) Authentication, Authorization, and Accounting (AAA) Access Control Lists (ACL) for IPv4, IPv6, and L2 BGP FlowSpec Unicast Reverse Path Forwarding (uRPF) 802.1X |
| Key Software Feature Support - OAM |
|---|
| Features | Link Layer Discovery Protocol (LLDP) Cisco Discovery Protocol (CDP) Internet Control Message Protocol (ICMP) Dynamic Host Configuration Protocol (DHCP), DHCP Relay Bidirectional Forwarding Detection (BFD) v4, v6 MPLS OAM Connectivity Fault Management (CFM) Y.1731 Delay Measurement (DM) Y.1731 Synthetic Loss Measurement (SLM) Two-Way Active Measurement Protocol (TWAMP, TWAMP Lite) IP SLA (Service-Level Agreement) NetFlow, sFlow, IPFIX 315 Switch Port Analyzer (SPAN, ERSPAN, SPAN to file) Dying Gasp |
| Key Software Feature Support - Manageability |
|---|
| Features | Command-Line Interface (CLI) SSH, Telnet, SCP, FTP, TFTP Simple Network Management Protocol (SNMP) Network Configuration Protocol (NETCONF) gRPC (Remote Procedure Calls) YANG models (OpenConfig, IETF) Model/event-Driven Telemetry (MDT) RPM-based software infrastructure Embedded Event Manager (EEM) Zero-Touch Provisioning (ZTP) Secure Zero-Touch Provisioning (sZTP) |
| Regulatory Standards Compliance |
|---|
| Regulatory compliance | Products comply with CE Markings according to directives 2014/30/EU and 2014/35/EU |
| Network Equipment Building Standards (NEBS) | GR-63-CORE GR-1089-CORE 8011-32Y8L2H2FH: GR-3108 Class-1 8011-4G24Y4H-I: GR-3108 Class-2 |
| ATIS TEER certification | ATIS-0600015.03.2009 |
| Safety | ANSI / UL 60950-1 CAN/CSA C22.2 No. 60950-1 ANSI / UL 62368-1 CAN/CSA C22.2 No. 62368-1 EN / IEC 62368-1 |
| EMC standards (Emissions) | 47 CFR Part 15:2016 CISPR32:2012:Ed:1 CISPR32:2015:Ed:2 CNS 15936:2016 EN 55032:2012 EN 55032:2015 EN 61000-3-3:2013+A1:2019 EN IEC 61000-3-2:2019+A1:2020 EN300 386:2012:V1.6.1 EN300 386:2021:V2.1.23 ICES-003:2020:Iss:7 KS C 9610-3-2:2020 KS C 9610-3-3:2020 KS C 9832:2019 VCCI-CISPR 32:2016 1TR9:2016 EN50121-4:2016 EN50121-4:2016:A1:2019 IEC62236-4:2018:Ed:3.0 TEC 11016:2016_TEC/SD/DD/EMC-221/05/OCT16 EN 301 489-1:2019:V2.2.3 EN 301 489-19:2022:V:2.2.1 |
| EMC standards (Immunity) | CISPR24:2010+A1:2015 CISPR35:2016:Ed:1 EN 55035:2017 EN IEC61000-6-1:2019 EN300 386:2012:V1.6.1 EN300 386:2021:V2.1.23 EN61000-6-1:2007 EN61000-6-2:2005 EN61000-6-2:2019 IEC61000-6-1:2016:Ed:3 IEC61000-6-2:2016:Ed:3 KS C 9835:2019 1TR9:2005 1TR9:2016 EN50121-4:2016 EN50121-4:2016:A1:2019 IEC62236-4:2018:Ed:3.0 TEC 11016:2016_TEC/SD/DD/EMC-221/05/OCT16 EN 301 489-1:2019:V2.2.3 EN 301 489-19:2022:V:2.2.1 |
| ETSI | ETSI/EN 300 119 Part 4 ETS/EN 300 019 – Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2 ETS/EN 300 753 |
| RoHS | The product is RoHS-6 compliant with exceptions for leaded-Ball Grid-Array (BGA) balls and lead press-fit connectors. |
| Ordering Information - Routers |
|---|
| Router product ID | 8011-4G24Y4H-I |
| Description | Cisco 8010 4x1G Cu, 24x25G, 4x100G QSFP28 |
| Power supply for AC variant | PWR-400-AC |
| Power supply for DC variant | PWR-400-DC |
| Fans | Not Applicable |
| Timing card | 8000-TIC 8000-TIC-GNSS (optional) |
| FCS software | Cisco IOS XR 25.1.1 |
| Router product ID | 8011-32Y8L2H2FH |
| Description | Cisco 8010 32x25G, 8x50G, 2x100G QSFP28, 2x400G QDD |
| Power supply for AC variant | PWR-650-AC-R |
| Power supply for DC variant | PWR-930-DC-R |
| Fans | FAN-1RU-PI-V3 |
| Timing card | 8000-TIC 8000-TIC-GNSS (optional) |
| FCS software | Cisco IOS XR 25.4.1 |
| Accessories - 8011-4G24Y4H-I |
|---|
| CBL-BRKT-V1 | Cable Management Bracket for 8010 Series |
| RCKMT-19-V1 | 19-inch Rack Mounting Kit for 8010 Series |
| RCKMT-ETSI-V1 | 21-inch (ETSI) Rack Mounting Kit for 8010 Series |
| RCKMT-23-V1 | 23-inch Rack Mounting Kit for 8010 Series |
| Accessories - 8011-32Y8L2H2FH |
|---|
| CBL-BRKT-V2 | Cable Management Bracket for 8010 Series Router |
| RCKMT-19-KIT1 | 2 Post 19-inch Rack Mounting Kit for 8010 Series |
| RCKMT-19-KIT2 | 4 Post 19-inch Rack Mounting Kit for 8010 Series |
| RCKMT-ETSI-KIT1 | 2 Post 21-inch (ETSI) Rack Mounting Kit for 8010 Series |
| RCKMT-ETSI-KIT2 | 4 Post 21-inch (ETSI) Rack Mounting Kit for 8010 Series |
| RCKMT-23-KIT1 | 2 Post 23-inch Rack Mounting Kit for 8010 Series |
| RCKMT-23-KIT2 | 4 Post 23-inch Rack Mounting Kit for 8010 Series |
| CAB-48DC-40A-8AWG | C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A |
| Software Licenses |
|---|
| ESS-NGA-10G-RTU | Access Network SW&Autom Ess 1.0 Perp RTU (per 10G) |
| ADN-NGA-10G-RTU | Access Network SW&Autom Adn 1.0 Perp RTU (per 10G) |
| PRM-NGA-10G-RTU | Access Network SW&Autom Prm 1.0 Perp RTU (per 10G) |
| NGA-L-SIA-3 | SIA per system for 3 years - Large |
| NGA-L-SIA-5 | SIA per system for 5 years – Large |
| Power Cables |
|---|
| CAB-AC-SA | Power Cord - South Africa, 16/10A, 250V, 1830mm, -40C to +85C |
| CAB-AC-ARG | Power Cord - Argentina, 10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-ISR | Power Cord - Israel, 16/10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-TAI | Power Cord - Taiwan, 15/10A, 125V, 2500mm, -40C to +85C |
| CAB-AC-CHI | Power Cord - China, 10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-KOR | Power Cord - Korea, 16/10A, 125V, 2500mm, -40C to +85C |
| CAB-AC-EUR | Power Cord - Europe, 16/10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-ITL | Power Cord - Italy, 10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-UK | Power Cord - UK, 13/10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-AUS | Power Cord - Australia, 10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-US | Power Cord - US, 15A, 125V, 2500mm, -40C to +85C |
| CAB-AC-BRA | Power Cord - Brazil, 10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-IND | Power Cord - India, 16/10A, 250V, 2500mm, -40C to +85C |
| CAB-AC-SUI | Power Cord - Swiss, 10A, 250V, 2500mm, -40C to +85C |
| Sustainability Information |
|---|
| General | Information on product-material-content laws and regulations |
| Electronic waste | Information on electronic waste laws and regulations, including our products, batteries, and packaging |
| Takeback and reuse | Information on product takeback and reuse program |
| Sustainability inquiries | Contact: [email protected] |
| Material | Product packaging weight and materials |