| System Specifications |
|---|
| Cisco NCS4201-SA Physical (H x W x D) | 1.72 x 17.5 x 10 in. (43.7 x 444.5 x 255 mm), 1RU |
| Cisco NCS4202-SA Physical (H x W x D) | 1.73 x 17.5 x 11.28 in. (44 x 444.5 x 286.54 mm), 1RU |
| Cisco NCS4201-SA Weight | 8.5 lb (3.9kg) - empty chassis |
| Cisco NCS4202-SA Weight | 9.25 lb (4.2 kg) - empty chassis |
| Rack Mounts | ETSI rack-mount kit, 19-in. rack-mount kit, 23-in. rack-mount kit |
| Air Flow | Front-to-back |
| Power Supplies | 2 power supplies (AC or DC) |
| NCS4201-SA MTBF (hours) | 546,260 |
| ASR-920-FAN-F MTBF (hours) | 2,581,770 |
| ASR-920-PWR-A MTBF (hours) | 1,598,000 |
| ASR-920-PWR-D MTBF (hours) | 1,129,417 |
| NCS4202-SA MTBF (hours) | 466,660 |
| ASR-920-FAN-TRAY MTBF (hours) | 1,177,570 |
| A920-PWR400-A MTBF (hours) | 1,935,410 |
| A920-PWR400-D MTBF (hours) | 2,580,540 |
| Power Specifications |
|---|
| Cisco NCS4201-SA Power Consumption | Max 145W, Typical: 110W |
| Cisco NCS4202-SA Power Consumption | Max 150W, Typical: 130W (without PoE) |
| AC Input Voltage and Frequency | Voltage range: 85V AC to 264V AC, nominal 100V AC to 240V AC; Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz |
| Cisco NCS4201-SA DC Input Voltage | Voltage range: -18 to -32 VDC or -36 to -72 VDC; Nominal: -24 VDC/-48 VDC |
| Cisco NCS4202-SA DC Input Voltage | Voltage range: -18 VDC to -32 VDC or -40 VDC to -72 VDC; Nominal -24VDC/-48VDC/-60VDC |
| Environmental Specifications |
|---|
| Operating Environment and Altitude | -40 to 70˚C, up to 1,000 feet (300m); -40 to 65˚C, up to 6,000 feet (1800m); -40 to 55˚C, up to 13,000 feet (4000m) |
| Relative Humidity | 5 to 95 percent, noncondensing |
| Acoustic Noise | Acoustic noise peak operation maximum 55 dBA (59 dBA for NCS4202-SA) sound pressure level, bystander position for rack-mount products at 20˚C operation as measured by ISO 7779 NAIS noise measurement test standard. Acoustic noise peak operation compliant to NEBS GR-63-Core Issue 3 sound power level of 78 dB at 27˚C operation as measured by ANSI S12.10/ISO 7779 NAIS noise measurement test standard. Actual measurement is less than 63dB. |
| Storage Environment | Temperature: -40 to 70˚C; altitude: 15,000 feet (4570m) |
| Seismic | Zone 4 |
| Safety and Compliance |
|---|
| Safety Standards | UL 60950-1 2nd edition, CAN/CSA C22.2 No. 60950-1-07 2nd edition, IEC 60950-1 2nd edition, EN 60950-1 2nd edition, AS/NZS 60950.1:2003 |
| Electromagnetic Emissions | FCC CFR47 Part 15 Class A, EN55022 class A, CISPR22 class A, ICES-003 class A, EN 300 386 class A, VCCI class A, KN32 class A, EN61000-3-2 to EN61000-3-3 |
| Immunity Compliance | EN 300 386, EN 61000-6-1, EN 50082-1, CISPR24, EN 55024, KN 35, EN/KN 61000-4-2 to EN/KN 61000-4-6, EN/KN 61000-4-8, EN/KN 61000-4-11 |
| NEBS | GR-63-CORE Issue 4, GR-1089-CORE Issue 6, SR-3580 NEBS Issue 4 |
| ETSI | ETS/EN 300 119 Part 4, ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2 (NCS4201 only) |
| Network Synchronization Standards | ANSI T1.101, GR-1244-CORE, GR-253-CORE, ITU-T G.703 clause 5, ITU-T G.703 clause 9, ITU-T G.781, ITU-T G.813, ITU-T G.823, ITU-T G.824, ITU-T G.8261/Y.1361, ITU-T G.8262, ITU-T G.8264, IEEE1588-2008 |
| Ordering Information - NCS 4201 System Components |
|---|
| NCS4201-SA | NCS 4201 Shelf Assembly - 4x10GE + 24x GE/FE (1 RU) |
| NCS4200-1RU-DOOR | NCS 4200 1 RU Door and Ancillary |
| ASR-920-PWR-A | ASR 920 AC Power Supply |
| ASR-920-PWR-D | ASR 920 DC Power Supply |
| SNCS4201NK9176 | Cisco NCS 4201 IOS XE 17.6.1 UNIVERSAL |
| SNCS4201NK9177 | Cisco NCS 4201 IOS XE 17.7.1 UNIVERSAL |
| SNCS4201NK9178 | Cisco NCS 4201 IOS XE 17.8.1 UNIVERSAL |
| SNCS4201NK9179 | Cisco NCS 4201 IOS XE 17.9.1 UNIVERSAL |
| SNCS4201NK91710 | Cisco NCS 4201 IOS XE 17.10.1 UNIVERSAL |
| ASR-920-FAN-F | ASR 920 Fan for Fixed Chassis |
| A920-RCKMT-19 | EIA 19in Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-ETSI | ETSI Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-23 | EIA 23in Rack mount Option for the Cisco ASR 920 |
| Ordering Information - NCS 4202 System Components |
|---|
| NCS4202-SA | NCS 4202 Shelf Assembly - 4x10GE + 12x GE/FE + 1 IM slot (1 RU) |
| NCS4200-1RU-DOOR | NCS 4200 1 RU Door and Ancillary |
| A920-PWR400-A | Cisco ASR 920 400W AC PSU |
| A920-PWR400-D | Cisco ASR 920 400W DC PSU |
| SNCS4202NK9176 | Cisco NCS 4202 IOS XE 17.6.1 UNIVERSAL |
| SNCS4202NK9177 | Cisco NCS 4202 IOS XE 17.7.1 UNIVERSAL |
| SNCS4202NK9178 | Cisco NCS 4202 IOS XE 17.8.1 UNIVERSAL |
| SNCS4202NK9179 | Cisco NCS 4202 IOS XE 17.9.1 UNIVERSAL |
| SNCS4202NK91710 | Cisco NCS 4202 IOS XE 17.10.1 UNIVERSAL |
| SNCS4202K9176 | Cisco NCS 4202 IOS XE 17.6.1 PAYLOAD ENCRYPTION |
| SNCS4202K9177 | Cisco NCS 4202 IOS XE 17.7.1 PAYLOAD ENCRYPTION |
| SNCS4202K9178 | Cisco NCS 4202 IOS XE 17.8.1 PAYLOAD ENCRYPTION |
| SNCS4202K9179 | Cisco NCS 4202 IOS XE 17.9.1 PAYLOAD ENCRYPTION |
| SNCS4202K91710 | Cisco NCS 4202 IOS XE 17.10.1 PAYLOAD ENCRYPTION |
| ASR-920-FAN-TRAY | Cisco ASR 920 Fan Tray |
| A920-RCKMT-19 | EIA 19in Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-ETSI | ETSI Rack mount Option for the Cisco ASR 920 |
| A920-RCKMT-23 | EIA 23in Rack mount Option for the Cisco ASR 920 |
| Interface Modules Supported on NCS 4202 |
|---|
| NCS4200-8E1T1-CE | NCS 4200 8x T1/E1 CEM Line Card - RJ48C, Supported as of 3.18.0SP |
| NCS4200-1T8LR-PS | NCS 4200 1x 10GE + 8x GE/FE Line Card, Supported as of 17.3.1 |
| NCS4200-3GMS | NCS 4200 12x T1/E1, 4x T3/E3, 4x OC3/12 / STM-1/4 Line Card, Supported as of 16.7.1 |
| Ethernet Optics Supported in 8-Port 1GE SFP and 1-Port 10GE SFP+ Module |
|---|
| GLC-FE-100FX | 100BASE-FX SFP for Fast Ethernet SFP Ports, 1310 nm wavelength, 2 km over MMF, Supported as of 3.18.0SP |
| GLC-FE-100LX | 100BASE-LX SFP for Fast Ethernet SFP Ports, 1310 nm wavelength, 10 km over SMF, Supported as of 3.18.0SP |
| GLC-FE-100EX | 100BASE-EX SFP for Fast Ethernet SFP Ports, 1310 nm wavelength, 40 km over SMF, Supported as of 3.18.0SP |
| GLC-FE-100ZX | 100BASE-ZX SFP for Fast Ethernet SFP Ports, 1550 nm wavelength, 80 km over SMF, Supported as of 3.18.0SP |
| GLC-FE-100FX-RGD | 100BASE-FX SFP module for Industrial Ethernet 100-MB ports, 1310 nm wavelength, 2 km over MMF, Supported as of 3.18.0SP |
| GLC-FE-100LX-RGD | 100BASE-LX SFP module for Industrial Ethernet 100-MB ports, 1310 nm wavelength, 10 km over SMF, Supported as of 3.18.0SP |
| GLC-FE-100BX-U | 100BASE-BX10-U SFP for Fast Ethernet SFP Ports. Single-strand SMF up to 10 km, transmits on a 1310-nm channel and receives on a 1550-nm signal, Supported as of 3.18.0SP |
| GLC-FE-100BX-D | 100BASE-BX10-D SFP for Fast Ethernet SFP Ports. Single-strand SMF up to 10 km, transmits on a 1550-nm channel and receives on a 1310-nm signal, Supported as of 3.18.0SP |
| GLC-SX-MMD | 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-LH-SMD | 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-EX-SMD | 1000BASE-EX SFP transceiver module for SMF, 1310-nm wavelength, extended operating temperature range and Digital Optical Monitoring (DOM) support, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-ZX-SMD | 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, extended operating temperature range and Digital Optical Monitoring (DOM) support, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-SX-MM-RGD | 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, industrial Ethernet, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-LX-SM-RGD | 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength, industrial Ethernet, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-ZX-SM-RGD | 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, industrial Ethernet, dual LC/PC connector, Supported as of 3.18.0SP |
| GLC-TE | 1000BASE-T SFP transceiver module for Category 5 copper wire, extended operating temperature range, RJ-45 connector, Supported as of 16.5.1 |
| SFP-GE-T | 1000BASE-T SFP transceiver module for Category 5 copper wire, extended operating temperature range, RJ-45 connector, Supported as of 3.18.0SP |
| SFP-GE-S | 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, Supported as of 3.18.0SP |
| SFP-GE-L | 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1310-nm wavelength, Supported as of 3.18.0SP |
| SFP-GE-Z | 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, Supported as of 3.18.0SP |
| GLC-BX-D | 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX-U | 1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX40-U-I | 1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength, 40 km reach, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX40-D-I | 1000BASE-BX10 SFP module for single-strand SMF, 1550-nm TX/1310-nm RX wavelength, 40 km reach, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX40-DA-I | 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength, 40 km reach, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX80-U-I | 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1490-nm RX wavelength, 80 km reach, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-BX80-D-I | 1000BASE-BX10 SFP module for single-strand SMF, 1570-nm TX/1310-nm RX wavelength, 80 km reach, single LC/PC connector, Supported as of 3.18.0SP |
| GLC-GE-DR-LX | Dual Rate 100BASE-LX / 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector, Supported as of 16.5.1 |
| ONS-SC-GE-LX | 1000BASE-LX Gigabit Ethernet transceiver module for SMF, 1310 nm wavelength, commercial operating temperature range and DOM support, dual LC/PC connector, Supported as of 16.5.1 |
| ONS-SI-GE-LX | 1000BASE-LX Gigabit Ethernet transceiver module for SMF, 1310 nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector, Supported as of 3.18.0SP |
| ONS-SC-GE-BXD | 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength, single LC/PC connector, Supported as of 16.5.1 |
| ONS-SC-GE-BXU | 1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength, single LC/PC connector, Supported as of 16.5.1 |
| ONS-SE-ZE-EL | 10/100/1000BASE-T SFP transceiver module for Category 5 copper wire, extended operating temperature range, RJ-45 connector, Supported as of 3.18.0SP |
| ONS-SE-Z1 | 1000BASE-LX Gigabit Ethernet / OC-48/STM-16 IR / OC-12/-2 / STM-1/-4 SR transceiver module, 1310 nm, SFP, extended temperature range, Supported as of 16.5.1 |
| DWDM-SFP-xxxx (36 wavelengths) | Cisco 1000BASE-DWDM Gigabit Ethernet SFP, with 36 different wavelengths ranging from 1561.42 nm to 1530.33nm or ITU channel 20 to 59, Supported as of 3.18.0SP |
| DWDM-SFP10G-C | Cisco 10G BASE-DWDM tunable SFP+ with 96 DWDM ITU-50GHz channels to which the device can be tuned, ranging from 1528-nm to 1566-nm, Supported as of 3.18.0SP |
| CWDM-SFP-xxxx (8 wavelengths) | Cisco CWDM Gigabit Ethernet SFP, with eight different wavelengths ranging from 1470 nm to 1610 nm, Supported as of 3.18.0SP |
| SFP-10G-SR-S | Cisco 10GBASE-SR Ethernet SFP+ transceiver module for MMF, 850 nm, S-class, Supported as of 3.18.0SP |
| SFP-10G-LR-S | Cisco 10GBASE-LR Ethernet SFP+ transceiver module for SMF, 1310 nm, S-class, Supported as of 3.18.0SP |
| SFP-10G-ER-S | Cisco 10GBASE-ER Ethernet SFP+ transceiver module for SMF, 1550 nm, S-class, Supported as of 3.18.0SP |
| SFP-10G-ZR-S | Cisco 10GBASE-ZR Ethernet SFP+ transceiver module for SMF, 1550 nm, S-class, Supported as of 3.18.0SP |
| SFP-10G-SR | Cisco 10GBASE-SR Ethernet SFP+ transceiver module for MMF, 850 nm, Supported as of 3.18.0SP |
| SFP-10G-LR | Cisco 10GBASE-LR Ethernet SFP+ transceiver module for SMF, 1310 nm, Supported as of 3.18.0SP |
| SFP-10G-ER | Cisco 10GBASE-ER Ethernet SFP+ transceiver module for SMF and MMF, 1550 nm, Supported as of 3.18.0SP |
| SFP-10G-ZR | Cisco multirate 10GBASE-ZR, 10GBASE-ZW and OTU2/OTU2e SFP+ transceiver module for SMF and MMF, 1550 nm, Supported as of 3.18.0SP |
| SFP-10G-SR-X | Cisco 10GBASE-SR Ethernet SFP+ transceiver module for MMF, 850 nm, extended temperature range, Supported as of 3.18.0SP |
| SFP-10G-LR-X | Cisco 10GBASE-LR Ethernet SFP+ transceiver module for SMF, 1310 nm, extended temperature range, Supported as of 3.18.0SP |
| ONS-SC+-10G-SR | Cisco 10GBASE-SR Ethernet SFP+ transceiver module for MMF, 850 nm, commercial temperature range, Supported as of 3.18.0SP |
| ONS-SC+-10G-LR | Cisco 10GBASE-LR Ethernet SFP+ transceiver module for SMF, 1310 nm, commercial temperature range, Supported as of 3.18.0SP |
| ONS-SC+-10G-ER | Cisco 10GBASE-ER Ethernet SFP+ transceiver module for SMF, 1550 nm, commercial temperature range, Supported as of 3.18.0SP |
| ONS-SC+-10G-ZR | Cisco 10GBASE-ZR Ethernet SFP+ transceiver module for SMF, 1550 nm, commercial temperature range, Supported as of 3.18.0SP |
| ONS-SI-GE-SX | 1000BASE-SX Gigabit Ethernet transceiver module for MMF, 1310 nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector, Supported as of 16.5.1 |
| ONS-SI-GE-ZX | 1000BASE-ZX Gigabit Ethernet transceiver module, SMF, 1550 nm, SFP, industrial temperature range, Supported as of 16.5.1 |
| ONS-SI+-10G-SR | Cisco 10GBASE-SR Ethernet SFP+ transceiver module for MMF, 1310 nm, industrial temperature range, Supported as of 17.1.1 |
| ONS-SI+-10G-ER | Cisco 10GBASE-ER Ethernet SFP+ transceiver module for SMF, 1550 nm, industrial temperature range, Supported as of 17.1.1 |
| ONS-SI+-10G-LR | Cisco 10GBASE-LR Ethernet SFP+ transceiver module for SMF, 1310 nm, industrial temperature range, Supported as of 17.1.1 |
| ONS-SI+-10G-ZR | Cisco 10GBASE-ZR Ethernet SFP+ transceiver module for SMF, 1550 nm, industrial temperature range, Supported as of 17.1.1 |
| SFP-10G-ZR-S | Cisco 10GBASE-ZR Ethernet SFP+ transceiver module for SMF, 1550 nm, S-class, Supported as of 17.7.1 |
| DWDM-SFP10G-xx.xx | Cisco multirate (LAN/WAN/OTU2/OTU2E) 10GBASE-DWDM single wavelength SFP+ module (100-GHz ITU grid) – 40 individual wavelength pluggable modules, Supported as of 3.18.0SP |
| ONS-SC+-10G-xx.x | Cisco multirate 10G BASE DWDM SFP+ with different wavelengths ranging from 1530-nm to 1561-nm, 100 GHz, LC, Supported as of 3.18.0SP |
| ONS-SC+-10GEPxx.x | Cisco multirate 10G BASE DWDM Edge Performance SFP+ with different wavelengths ranging from 1530-nm to 1561-nm, 100 GHz, LC, Supported as of 3.18.0SP |
| SFP-10G-BXD-I | 10GBASE-BX single-strand SMF bidirectional SFP+ module, 1320-nm to 1340-nm TX/1260-nm to 1280-nm RX wavelength, single LC/PC connector, 10 km reach, Supported as of 3.18.0SP |
| SFP-10G-BXU-I | 10GBASE-BX single-strand SMF bidirectional SFP+ module, 1260-nm to 1280-nm TX/1320-nm to 1340-nm RX wavelength, single LC/PC connector, 10 km reach, Supported as of 3.18.0SP |
| SFP-10G-BX40D-I | 10GBASE-BX single-strand SMF bidirectional SFP+ module, 1320-nm to 1340-nm TX/1260-nm to 1280-nm RX wavelength, single LC/PC connector, 40 km reach, Supported as of 3.18.0SP |
| SFP-10G-BX40U-I | 10GBASE-BX single-strand SMF bidirectional SFP+ module, 1260-nm to 1280-nm TX/1320-nm to 1340-nm RX wavelength, single LC/PC connector, 40 km reach, Supported as of 3.18.0SP |
| Optics Supported in NCS 4200 12-port T1/E1 + 4port DS3/E3 + 4-Port OC3/STM1 or 4-Port OC12/STM4 or 1-port OC48/STM-16 |
|---|
| ONS-SI-155-SR-MM | OC-3/STM-1, Short Reach (SR), 1310 nm, Multimode (MM), SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-155-I1 | OC-3/STM-1 Intermediate Reach (IR), 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-155-L1 | OC-3/STM-1 Long Reach (LR), 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-155-L2 | OC-3/STM-1 LR, 1550 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SC-155-EL | STM-1 Electrical SFP, Commercial temperature range, Supported as of 16.7.1 |
| ONS-SI-622-SR-MM | OC-12/STM-4, SR, 1310 nm, MM, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-622-I1 | OC-12/STM-4 IR, 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-622-L1 | OC-12/STM-4 LR, 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-622-L2 | OC-12/STM-4 LR, 1550 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-2G-I1 | OC-48/STM-16 IR, 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-2G-L1 | OC-48/STM-16 LR, 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-2G-L2 | OC-48/STM-16 LR, 1550 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| ONS-SI-2G-S1 | OC-48/STM-16 SR, 1310 nm, SFP, industrial temperature range, Supported as of 16.7.1 |
| Accessories for 12-port T1/E1 + 4port DS3/E3 Interface Module |
|---|
| PANEL-3G-COMBO-1 | Single 12 x E1 + 4xDS3 Patch panel for 3G CEM/IMSG interface module, Supported as of 16.7.1 |
| PANEL-3G-COMBO-2 | Double 12 x E1 + 4xDS3 Patch panel for 3G CEM/IMSG interface module, Supported as of 16.7.1 |
| PANEL-3G-COMBO-1S | Single 12 x E1 + 4xDS3 Patch panel for 3G CEM/IMSG interface module(Requires straight-through cable), Supported as of 16.7.1 |
| PANEL-3G-COMBO-2S | Double 12 x E1 + 4xDS3 Patch panel for 3G CEM/IMSG interface module(Requires straight-through cable), Supported as of 16.7.1 |
| P3G1-RCKMNT-19IN | EIA 19 Inch mounting brackets for single 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| P3G1-RCKMNT-ETSI | ETSI 21 Inch mounting brackets for single 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| P3G1-RCKMNT-23IN | EIA 23 Inch mounting brackets for single 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| P3G2-RCKMNT-19IN | EIA 19 Inch mounting brackets for double 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| P3G2-RCKMNT-ETSI | ETSI 21 Inch mounting brackets for double 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| P3G2-RCKMNT-23IN | EIA 23 Inch mounting brackets for double 3G CEM/IMSG IM patch panel, Supported as of 16.7.1 |
| CABLE-16TDM-C | 16 port cable for TDM CEM IM, no red, 10 Feet, Supported as of 16.7.1 |
| CABLE-16TDM-C-L1 | 16 port cable for TDM CEM IM, no red, 56" / 4.7 ft / 1.4 m, Supported as of 16.7.1 |
| CABLE-16TDM-C-L2 | 16 port cable for TDM CEM IM, no red, 63" / 5.3 ft / 1.6 m, Supported as of 16.7.1 |
| CABLE-16TDM-C-L3 | 16 port cable for TDM CEM IM, no red, 85" / 7.1ft / 2.2 m, Supported as of 16.7.1 |
| CABLE-16TDM-C-L4 | 16 port cable for TDM CEM IM, no red, 96" / 8 ft / 2.4 m, Supported as of 16.7.1 |