| Cable Connectivity |
|---|
| Model/SKU | CAB-MPO24-2XMPO12 |
| Type | 2X40GE Breakout Cable |
| Form Factor | MPO Breakout |
| Data Rate | 2 x 40 Gbps |
| Connector Type A | MPO-24 |
| Connector Type B | 2 x MPO-12 |
| Compatible Module | EPA-CPAK-2X40GE |
| Fiber Type | Multimode (Estimated based on MPO standard) |
| Reach | Short reach data center (Estimated; check optics matrix for exact) |
| Supported Switch Models (Table 1) |
|---|
| Cisco Nexus 92348GC-X | 48p 100M/1G Base-T ports + 4p 1/10/25G SFP28,+2p 40/100G QSFP28 |
| Cisco Nexus 92348GC-FX3 | 48p 10M/100M/1G Base-T ports + 4p 1/10/25G SFP28,+2p 40/100G QSFP28 |
| Cisco Nexus 92160YC-X | 48 x 1/10/25-Gbps SFP+ ports and 6 x QSFP28 ports (4 of the 6 QSFP28 ports are 100Gbps capable) |
| Cisco Nexus 92300YC | 48 x 1/10/25-Gbps SFP+ ports and 18 x 40/100-Gbps QSFP28 ports |
| Cisco Nexus 9272Q | 72 x 40-Gbps QSFP+ ports |
| Cisco Nexus 92304QC | 56 x 40-Gbps QSFP+ ports and 8 x 40/100-Gbps QSFP28 ports |
| Cisco Nexus 9236C | 36 x 40/100-Gbps QSFP28 ports |
| Ports and Supported Speeds (Table 2 Excerpt) |
|---|
| 92348GC-X Ports | 48p 100M/1G Base-T ports + 4p 1/10/25G SFP28,+2p 40/100G QSFP28 |
| 92348GC-X Supported Speeds | 100M, 1 Gbps on Base-T ports and 1, 10, and 25 Gbps on SFP28 ports 40 and 100G Gbps on QSFP28 |
| 92160YC-X Ports | 48 x 10- and 25-Gbps SFP+ and 6 QSFP28 ports (4 are 100-Gbps capable) |
| 92160YC-X Supported Speeds | 1, 10, and 25 Gbps on SFP+ ports 10, 25, 40, and 100 Gbps on QSFP ports |
| 9236C Ports | 36 x 100-Gbps QSFP28 ports |
| 9236C Supported Speeds | 1, 10, 25, 40, 50, and 100 Gbps |
| 92300YC Ports | 48 x 10- and 25-Gbps SFP+ and 18 100-Gbps ports |
| 92300YC Supported Speeds | 1, 10, and 25 Gbps on SFP+ ports 40 and 100 Gbps on QSFP ports |
| Performance & Scalability (Table 3) |
|---|
| Number of LPM routes (92348GC-X) | Default: 16,000 |
| Number of IP host entries (92348GC-X) | Default: 16,000 |
| Number of MAC address entries (92348GC-X) | 97,000 |
| Number of multicast routes (92348GC-X) | Shipping: 8000 |
| Number of IGMP snooping groups (92348GC-X) | Shipping: 8000 |
| Number of ACL entries ingress/egress (92348GC-X) | Per slice: 3000 ingress 2000 egress |
| Maximum VLANs | 4096 |
| Number of VRF instances (92348GC-X) | Shipping: 1000 |
| Max links in port channel | 32 |
| Max ECMP paths (92348GC-FX3) | 128-way |
| Max ECMP groups | 256 |
| Max port channels | 512 |
| Active SPAN sessions | 4 |
| RPVST instances | 3967 |
| HSRP groups | 490 |
| MST instances | 64 |
| NAT entries | 1023 |
| System Hardware |
|---|
| CPU (92348GC-X) | 4 cores |
| System memory (92348GC-X) | 8 GB |
| SSD drive (92348GC-X) | 16GB |
| Shared buffer (92348GC-X) | 40 MB |
| Management ports (92348GC-X) | 2 ports: 1 RJ-45 and 1 SFP |
| USB ports | 1 |
| RS-232 serial ports | 1 |
| Power Specifications |
|---|
| Power supplies (92348GC-X) | 400W AC, 400/350W DC |
| Typical power AC (92348GC-X) | 150W |
| Maximum power AC (92348GC-X) | 245W |
| Input voltage AC | 100 to 240V |
| Input voltage HVAC | 200 to 277V |
| Input voltage DC | -40 to -72V DC (minimum and maximum) -48 to -60V DC (nominal) |
| Frequency AC | 50 to 60 Hz |
| Physical & Environmental |
|---|
| Fans (92348GC-X) | 3 |
| Airflow | Port-side intake and exhaust |
| MTBF (92348GC-X) | 474,571 hours |
| Physical dimensions (92348GC-X) | 1.72 x 17.3 x 18.5 in. (4.4 x 43.9 x 45.7 cm) |
| Acoustics (92348GC-X) | 71.6 dBA at 50% fan speed, 75.7 dBA at 70% fan speed, and 81.0 dB at 100% fan speed |
| RoHS compliance | Yes |
| Operating temperature | 32 to 104°F (0 to 40°C) |
| Nonoperating temperature | -40 to 158°F (-40 to 70°C) |
| Humidity | 5 to 85% (noncondensing) |
| Altitude | 0 to 13,123 ft (0 to 4000m) |
| Weight (Table 5 Excerpt) |
|---|
| Cisco Nexus 92348GC-X without PSU/fans | 14.12 lb (6.4 kg) |
| Cisco Nexus 92160YC-X without PSU/fans | 14.12 lb (6.4 kg) |
| Cisco Nexus 92348GC-FX3 without PSU/fans | 14.5 lb (6.57 kg) |
| 350W AC power supply | 2.31 lb (1.0 kg) |
| 650W AC power supply | 2.42 lb (1.1 kg) |
| Regulatory Compliance (Table 6) |
|---|
| Regulatory compliance | CE Markings according to directives 2004/108/EC and 2006/95/EC |
| Safety | NEBS, UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, GB4943 |
| EMC Emissions | 47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A |
| EMC Immunity | EN55024, CISPR24, EN300386, KN 61000-4 series |
| RoHS | RoHS-6 compliant with exceptions for leaded-BGA balls and lead press-fit connectors |
| Ordering Information (Table 7 Excerpt - Base Switches & Accessories) |
|---|
| N9K-C92348GC-X | Nexus 9200 with 48p 100M/1G Base-T ports and 4p 1/10/25G SFP28 and 2p 40/100G QSFP28 |
| N9K-C92160YC-X | Nexus 9200 with 48p 1/10G/25G SFP+ and 6p 40G QSFP or 4p 100G QSFP28 |
| N9K-C9236C | Nexus 9200 with 36p 40G 100G QSFP28 |
| NXK-ACC-KIT-1RU | Nexus 3K/9K Fixed Accessory Kit, 1RU front and rear removal |
| N9K-C9300-ACK | Nexus 9K Fixed Accessory Kit |
| N9K-C9300-RMK | Nexus 9K Rack Fixed Mount Kit |