H3C CR19000-20 Router Chassis

H3C CR19000-20
H3C CR19000-20 Router Chassis. Switching Capacity: 967.68Tbps. Whole Machine Packet Forwarding Rate: 432000Mpps. Interface Type: Supports GE, 10GE, 40GE, 50GE, 100GE, 400GEInterface Supports 50G FlexE, 100G FlexEInterface Supports 10G2.5G622M155M POSInterface Supports 155M CPOSInterface
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C CR19000-20 Router Chassis |
| Key Specifications | |
| Switching Capacity | 967.68Tbps |
| Whole Machine Packet Forwarding Rate | 432000Mpps |
| Interface Type | Supports GE, 10GE, 40GE, 50GE, 100GE, 400GEInterface Supports 50G FlexE, 100G FlexEInterface Supports 10G\2.5G\622M\155M POSInterface Supports 155M CPOSInterface |
| Dimensions (W×D×H) | 440mm x 850mm x 1820mm, height approx. 41RU |
| Power Supply | Single-frame 24 power independent module, support redundancy backup, support intelligent power management |
| Ambient temperature | Operation: 0°C to 45°C |
| Product Specifications | |
| Number of master control slots (MPUs) | 2 |
| Number of network board slots (SFU) | 8 |
| Number of Line Card Slots (LPU) | 20 |
| Switching Capacity | 967.68Tbps |
| Whole Machine Packet Forwarding Rate | 432000Mpps |
| Routing Capacity (RIB) | >4 million entries |
| Power Supply | Single-frame 24 power independent module, support redundancy backup, support intelligent power management |
| Fan | Single-frame 33-fan micromodule with redundant backup support and intelligent cooling support |
| Dimensions (W×D×H) | 440mm x 850mm x 1820mm, height approx. 41RU |
| Ambient temperature | Operation: 0°C to 45°C |
| Ambient humidity | Operating: 5% to 95%, non-condensing |
| Altitude | -60m~5000m |
| Interface Type | Supports GE, 10GE, 40GE, 50GE, 100GE, 400GEInterface Supports 50G FlexE, 100G FlexEInterface Supports 10G\2.5G\622M\155M POSInterface Supports 155M CPOSInterface |
| EMC | FCC Part 15 (CFR 47) CLASS AICES-003 CLASS A VCCI-3 CLASS A VCCI-4 CLASS A CISPR 22 CLASS A EN 55022 CLASS A AS/NZS CISPR22 CLASS A CISPR 24EN 55024EN 61000-3-2EN 61000-3-3EN 61000-6-1ETSI EN 300 386 |
| Safety regulations | UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1/A11AS/NZS 60950EN 60825-1EN 60825-2FDA 21 CFR Subchapter J GB 4943 |
| Link Layer Characterization | Supports link layer encapsulation protocols such as Ethernet, PPP, and HDLC Supports Layer 2 Ethernet and Layer 3 Ethernet Supports Layer 2 Ethernet aggregation and Layer 3 Ethernet aggregation Supports MP and HDLC bundling Supports QinQ and DOT1Q termination |
| QoS | Traffic Supervision Traffic Shaping Traffic Redirection Traffic Filtering Congestion Avoidance Queue Scheduling Priority Mapping Rate Limiting (LR) QoS Policies (Interface Based, Control Plane Based) Dynamic Modification of QoS Policies QPPBHQoSRemark |
| ACL | Basic ACL (matches source IP address) Advanced ACL (matches Layer 3 and Layer 4 information) Layer 2 ACL (matches Layer 2 information) Time period-based ACLs Port ACLs, Global ACLs Support for ACL online updates Support for ACL counting |
| IPv4 protocols | TCP, UDP, RawIP, Ping Telnet, FTP, TFTPICMPv4DNSDHCPNATARP, ARP Proxy Policy Routing Port-based Route Scheduling Policy Supports Multi-Layer Repeat Matching |
| IPv6 protocols | IPv4/IPv6 Dual Protocol Stack TCP6, UDP6, RawIP6, Pingv6, Trace Route6Telnet6, FTP6, TFTP6DNS6ICMPv6VRRPv3DHCP6NAT64NDPMTUD(IPv6)6PE6VPEIPv6 Policy Routing Port-based Route Scheduling Policy support Multi-layer duplicate matching Support for ICMPv6 MIB, UDP6 MIB, TCP6 MIB, IPv6 MIBSupport for IPv4 to IPv6 transition technologies, including but not limited to manually configured tunnels, auto-configured tunnels, 6to4 tunnels, IPv6 over IPv4 tunnels, IPv4 over IPv6 tunnels, IPv6 over IPv6 tunnels, GRE over IPv6 tunnels, ISATAP tunnels, and so on. |
| IPv4Routing Protocols | RIPv1/v2OSPFv2IS-ISBGPv4BMPFlowspecIPv4static routingrouting policyroute recursion |
| IPv6Routing Protocols | RIPngOSPFv3IS-IS6BGPv4+BMPFlowspecIPv6static routingIPv6routing policyIPv6route recursion |
| Layer 3 multicast | Multicast Static Routing IPv4 Intra-Domain Multicast Routing IPv4 Inter-Domain Multicast Routing IPv4 Multicast Group Management IPv6 Intra-Domain Multicast Routing IPv6 Multicast Group Management Multicast VPNNG-MVPN |
| Interconnection Characteristics | Support for tunneling technologies such as VXLAN, GRE |
| MPLS Features | LDP LSP, RSVP-TEMPLS VPWS/VPLS/L3VPNRSVP TEP2MPPWE3MPLS OAMMPLS QoS Tunnel Policy |
| EVPN | EVPN VXLANEVPN VPWSEVPN VPLSEVPN L3VPNEVPN Data Center Interconnect Support for EVPN Tunnel TI-LFA Protection Support for EVPN L2VPN Access L3VPN over SR and SRv6 TE Policy Support for EVPN L3VPN, EVPN VPWS, EVPN VPLS Speed Limit Functionality Supports differential service priority tagging for EVPN L3VPN, EVPN VPWS, and EVPN VPLS. |
| SDN Features | NETCONFBGP-LSOpen FlowPCEPTelemetry supports intelligent WAN tuning algorithms in conjunction with controllers to support on-demand deployment and online adjustment of service bandwidth. |
| Segment Routing | SR BE, SR TE, SR TE Policy, support hot backup SR OAM, including MPLS SR ping tracert, bfd for lsp, tunnel, and other BFD probe linkage functions IGP protocol dynamic allocation SIDBGP protocol dynamic allocation SIDBGP EPE allocation SIDTI-LFA and anti-microloop SR TE Policy traffic statistics SR support label bonding binding SID support SR primary and backup paths, primary and backup tunnel protection and failure escape to BE function support L3VPN, EVPN L3VPN HoVPN VPNv4/VPNv6 over SR BE/SR-TE/SR TE Policy support L3VPN, EVPN L3VPN over SR BE/SR-TE/SR TE Policy Class A, Class B, Class C cross-domain support EVPN VPWSover SR BE/SR-TE/SR TE Policy, support dual attribution single active/dual active |
| SRv6 Features | SRv6 BE, SRv6 TE Policy, support for hot backup SRv6 OAM, include include ping tracert, sbfd for locator, srv6-policy, and other BFD probing linkage functions TI-LFA and anti-microloop SRv6 TE Policy traffic statistics SRv6 support for label bonding binding SIDSRv6 SFC supports SRv6 Policy UCMP and ECMP support APN6 function supports multiple candidate paths in SRv6 Policy to select the primary path according to priority, and also supports multiple Segment List according to the Weight attribute for the proportional distribution of traffic loads Support L3VPN, EVPN L3VPN HoVPN VPNv4/VPNv6 over SRv6 BE/SRv6 TE Policy Supports EVPN VPWS over SRv6 BE/SRv6 TE Policy, dual-attributed single-activity/dual-activity SRv6 TE Policy Supports BSID-based, Color-based, DSCP-based, CBTS-based, BGP-based, Flowspec-based, policy route-based, and policy route-based. Flowspec, policy routing and other flexible traffic diversion methods support SRv6 sampling, support for SRv6 tunnel inner layer message sampling support SRv6, can be upgraded through the software to meet the industry's latest standard features support for BGP SRv6 EPE, BGP-LS for SRv6 EPE support for controllers through the BGP automation of the issuance of SRv6TEPolicy supports cross-AS domain controllers to calculate end-to-end routes, realizing the cross-domain SRv6 function. |
| Device Security | Prevents single packet attacks Prevents scanning attacks Prevents flooding attacks Prevents TCP fragmentation attacks Prevents DOS/DDOS attacks Supports attack detection features Protocol message protection Message sending and receiving diagnostics Supports Control Plane Rate Limiting (COPP) Supports traffic monitoring by port mirroring Supports remote port mirroring Supports ACL traffic filtering and blackhole routing traffic blocking |
| Network Security | Message Legitimacy Check URPF Check Message Filtering Functions Prevent Data Message Attacks Prevent Protocol Message Attacks Prevent Protocol Message Attacks ARP Attacks Defend against ND Attacks Defend against BGP Attacks Defend against Protocol Classification Flow Restriction IPsecSSHSSLSAVI (Source Address Validity Verification) SAVNET (Intra-Domain Inter-Domain Source Address Verification Architecture Protocol) SMA (State Machine Based Forged Source Address Checking) Support FC- BGP Features |
| User Security | Device Management Security Network User Binding AAARBAC (Role Based Access Control) RADIUS, TACACS+ protocols supported |
| Device Management Method | Support SNMPv1/v2/v3 can be logged into the router through the Console port to for CLI configuration Support Telnet to this device to perform device management in a command line manner Support s Telnet (SSH) to this device to perform device management in a command line manner |
| Document Management | Support FTP/TFTP upload, download file support formatting, support file, directory creation, copy, delete, save file management functions |
| Network Maintenance | Ping Trace RouteLSP Ping/Tracert Port Loop Monitoring |
| Network Management | Network Management Platform iMCLLDP/LLDP-MEDMIB Synchronized Ethernet PTPNTPNet Stream Supports BGP-LS to collect network TOPO information Supports Twamp-Light to detect links, L3VPN latency, jitter, packet loss Supports 1731 to detect L2VPN latency, jitter, packet loss Supports EVPN VPWS, EVPN VPLS PW statistics and AC statistics support NQA, TWAMP, 2544, iFIT and other traffic detection technologies iFIT includes end-to-end detection, hop-by-hop detection of service delay, packet loss statistics, support for performance data obtained through telemetry uploads |
| Reliability | Master-Backup Reversal Online Hot Patch Uninterruptible Software Upgrade GRNSRVRRP, VRRPEBFD for VRRP/BGP/IS-IS/RIP/OSPF/Static Routing/SR/SRv6IP/IPv6/LDP/TE/VPN/VPNv6 FRR Non-Stop Forwarding (NSF) TI-LFA FRRDLDP BER Reversal Link Aggregation (Eth-Trunk), ECMP, UCMP and other cross-device link aggregation (S-Trunk) ETH OAM, CFD, Y.1731 All key modules (including the main control board, switching boards, service boards, power supplies, fans) are redundant, hot-swappable, and hot-swapping of key modules does not affect the normal operation of other components. A mother card supports a maximum of 4 daughter cards, mother card and daughter card can be hot-swappable support for cluster deployment, support for virtualization of two physical devices into a logical device, the cluster can achieve a consistent forwarding table entries, unified management, link aggregation across the physical device Mean Time Between Failure (MTBF) is greater than 12 years, the average time to repair (MTTR) is not more than 0.5 hours |
| Network Slicing | FlexEFlex-Algo sub-interface slicing Slice ID slicing supports SRv6 services carried on network hard slices |
| Deterministic network | Supports Det Net deterministic network technology with end-to-end latency of less than 20 microseconds |
| Ordering Information | |
| Main Control Engine Board | |
| 0231A5UM | CR-19K-MPU-20A - H3C CR19000-20 Supervisor Engine ModuleA |
| SFP+ 10G Port | |
| 0231A0A6 | SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231A5UN | CR-19K-MPU-20B - H3C CR19000-20 Supervisor Engine ModuleB |
| 0231AEUT | CR-19K-MPU-20C - H3C CR19000Supervisor Engine ModuleC |
| 0231AKVQ | 0231AKVQ - CR19000Routers |
| Mesh Board | |
| 0231A5UP | CR-19K-SFU-20C - H3C CR19000-20 Standalone Switching Network Board (Class C) |
| 0231A5UQ | CR-19K-MSFU-20C - H3C CR19000-20 Cluster Switching Fabric Board (Class C) |
| multimode fiber | |
| 0231A8G4 | CR-19K-FIBER-10M-12 - H3C CR19000 MSFU-20B Network Board Cluster Fiber Bundle (10m*12) |
| 0231A8G5 | CR-19K-FIBER-10M-36 - H3C CR19000 MSFU-20C Network Board Cluster Fiber Bundle (10 m × 36) |
| 1413A014 | OP-MTP24-MTP24-OM3-70-M - Fiber Connector - MTP (24-fiber)/Low-Loss Female Connector - MTP (24-fiber)/Low-Loss Female Connector - Multimode (OM3) - 3.8 mm - 70 m |
| 1413A011 | OP-MTP24-MTP24-OM3-10-M - Fiber Connector - MTP (24-fiber)/Female Connector - MTP (24-fiber)/Female Connector - Multimode (OM3) - 3.8 mm - 10 m |
| 1413A010 | OP-MTP24-MTP24-OM3-30-M - Fiber Connector - MTP (24-fiber)/Female Connector - MTP (24-fiber)/Female Connector - Multimode (OM3) - 3.8 mm - 30 m |
| 1413A012 | OP-MTP24-MTP24-OM3-50-M - Fiber Connector - MTP (24-fiber)/Female - MTP (24-fiber)/Female - Multimode (OM3) - 3.8 mm - 50 m |
| 1413A00Y | OP-MTP24-MTP24-OM4-100-M - Fiber Connector - MTP (24-fiber)/Female - MTP (24-fiber)/Female - Multimode (OM4) - 3.8 mm - 100 m |
| 0231A5UR | CR-19K-MSFU-20B - H3C CR19000-20 Cluster Switching Fabric Board (Class B) |
| Business Processing Unit (Master Card) | |
| 0231ADUR | CR-19K-LPU-8004 - H3C CR Flexible Interface Module (LPU-8004) |
| Ethernetinterface daughter card Module | |
| 0231ADUS | CR-HIC-CQ02 - H3C CR 2-Port 100G Ethernet Optical Interface Daughter Card (QSFP28) |
| QSFP Port | |
| 0231AFJA | QSFP-100G-ZR4-WDM1300 - 100G QSFP28 Optical Module (1300nm, 80km, ZR4, WDM, LC) |
| 0231A4UF | QSFP-100G-LR4-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 10 km, LR4, WDM, LC) |
| 0231A5LL | QSFP-100G-LR4L-WDM1300 - 100G QSFP28 Optical Module (1310nm, 2km, LR4L, CWDM4, LC) |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 40 km, ER4L, WDM, LC) |
| 0231A5UL | QSFP-100G-eSR4-MM850 - 100G QSFP28 Optical Module (850nm, 300m OM4, eSR4, MPO) |
| 0231A4B1 | QSFP-100G-SR4-MM850 - 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO) |
| 0231A2E4 | QSFP-40G-LR4-WDM1300 - QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC) |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850 - QSFP+ 40G BIDI Optical Module (850 nm, 100 m, SR) |
| 0231A4UG | QSFP-40G-ER4-WDM1300 - QSFP+ 40G Optical Module (1310 nm, 40 km, ER4, LC) |
| 0231A2NF | QSFP-40G-SR4-MM850 - QSFP+ 40G Optical Module (850 nm, 100 m, SR4, supports 1-to-4 splitting) |
| 0231A2KL | QSFP-40G-CSR4-MM850 - QSFP+ 40G Optical Module (850 nm, 300 m, CSR4, supports 1-to-4 splitting) |
| 0231AAQJ | CR-HIC-CQ01 - H3C CR 1-port 100G Ethernet Optical Interface daughter card (QSFP28) |
| 0231AF5Y | CR-HIC-CLGQ04F - H3C CR 4-Port 50G/2-Port 100G Ethernet Optical Interface Daughter Card (QSFP28) |
| QSFP28-Port | |
| 0231A3YJ | CR-HIC-XP12 - H3C CR 12-Port 10G Ethernet Optical Interface Daughter Card (SFP+) |
| SFP+ Optical Module | |
| 0231A0A8 | SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231AE0L | CR-HIC-XP12B - H3C CR 12-Port 10G Ethernet Optical Interface Daughter Card (SFP+) |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231AC9N | CR-HIC-XP10 - H3C CR 10-Port 1G/10G Ethernet Optical Interface Daughter Card (SFP+) |
| 0231A8JK | CR-19K-LPU-4004 - H3C CR Flexible Interface Module (LPU-4004) |
| HIC Interface Modules | |
| 0231A4PF | CR-HIC-CC01 - H3C CR 1-port 100G Ethernet Optical Interface daughter card (CFP2) |
| CFP2-Port | |
| 0231A3FF | CFP2-100G-LR4-WDM1300 - CFP2 100GOptical Module(10KM,SM,LR4) |
| 0231A3YH | CR-HIC-QQ03 - H3C CR 3-Port 40G Ethernet Optical Interface Daughter Card (QSFP+) |
| 0231A4PG | CR-HIC-GP12 - H3C CR 12-Port Gigabit Ethernet Optical Interface Daughter Card (SFP) |
| Gigabit Optical Module | |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI - SFP Gigabit BIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC) |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1310 nm, 40 km, LC) |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI - SFPGigabitBIDI Optical Module (TX 1490/RX 1550 nm, 70 km, LC) |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC) |
| 0231A4PH | CR-HIC-PU02 - H3C CR 2-Port 10G POS Optical Interface Daughter Card (XFP) |
| XFP Optical Module | |
| 0231A1RV | 0231A1RV - H3C CR 2-Port 10G POS Optical Interface Daughter Card (XFP) |
| 0231A72X | XFP-LH40-SM1550-F1 - XFP 10G Optical Module (1550 nm, 40 km, LC) |
| 0231A1RU | 0231A1RU - H3C CR 2-Port 10G POS Optical Interface Daughter Card (XFP) |
| 0231A04G | XFP-POS-LH10-SM1310 - Optical Module - XFP-10G POS - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A41G | XFP-LH80-SM1550 - Optical Module - XFP-10G - Single-Mode Module (1550 nm, 80 km, LC) |
| 0231A8JD | CR-HIC-PS04 - H3C CR 4-Port 2.5G/622M/155M POS Optical Interface Daughter Card (SFP) |
| Fast Ethernet Optical Module | |
| 0231A090 | SFP-FE-LH80-SM1550 - Optical Module—SFP 100M/155M Single-Mode Long-Distance Module—(1550 nm, 80 km, LC) |
| 0231A564 | SFP-FE-LX-SM1310-A - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A320 | SFP-FE-SX-MM1310-A - Optical Module—SFP 100M/155M Multimode Module (1310 nm, 2 km, LC) |
| 0231A965 | SFP-FE-LX-SM1310-D - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A089 | SFP-FE-LH40-SM1310 - Optical Module - SFP 100M/155M Single-Mode Module - (1310nm, 40km, LC) |
| 622M Optical Module | |
| 0231A40D | 0231A40D - H3C CR 4-Port 2.5G/622M/155M POS Optical Interface Daughter Card (SFP) |
| 0231A40B | SFP-622M-LX-SM1310 - 622M SFP Optical Module (1310 nm, 15 km, LC) |
| 2.5G Optical Module | |
| 0231A03Y | 0231A03Y - H3C CR 4-Port 2.5G/622M/155M POS Optical Interface Daughter Card (SFP) |
| 0231A03X | SFP-2.5G-LX-SM1310 - Optical Module—SFP—2.5G—Single-Mode Module—(1310 nm, 2 km, LC) |
| 0231A04A | 0231A04A - H3C CR 4-Port 2.5G/622M/155M POS Optical Interface Daughter Card (SFP) |
| 0231ADFS | CR-HIC-PHP08 - H3C CR 8-Port 622M/155M POS Optical Interface Daughter Card (SFP) |
| 0231A40D | 0231A40D - H3C CR 8-Port 622M/155M POS Optical Interface Daughter Card (SFP) |
| 0231ADFT | CR-HIC-CLP04 - H3C CR 4-Port 155M CPOS Optical Interface Daughter Card (SFP) |
| 0231ADFR | CR-HIC-ET16 - H3C CR 16-Port E1 Electrical Interface Daughter Card (HM96 Male Connector) |
| Cable | |
| 0231A2GG | SR0M7CAB2 - HM-96-pin E1 Cable (120 ohms, 3 m, RJ45) |
| 0231A2GF | SR0M7CAB1 - HM-96-pin E1 Cable (75 ohms, 3 m, BNC) |
| 0231A2GH | SR0M7CAB3 - HM-96-pin E1 Cable (75 ohms, 3 m, SMB) |
| 0231A8JG | CR-19K-LPU-2002 - H3C CR Flexible Interface Module (LPU-2002) |
| 0231A8FF | CR-19K-LPU-2002B - H3C CR Flexible Interface Module (LPU-2002B) |
| 0231AHM5 | CR-19K-LPU-4004B - H3C CR Flexible Interface Module B (LPU-4004B) |
| 0231AHM6 | CR-19K-LPU-8004B - H3C CR Flexible Interface Module B (LPU-8004B) |
| Service Module | |
| 0231A8FB | CR-19K-LPU-CQ18 - H3C CR 18-Port100GEthernet Optical Interface Module(QSFP28) |
| 0231AAQH | CR-19K-LPU-CQ12B - H3C CR 12-Port100GEthernetoptical interface ModuleB(QSFP28) |
| 0231A8JH | CR-19K-LPU-CQ12 - H3C CR 12-Port100GEthernet Optical Interface Module(QSFP28) |
| 0231A8JF | CR-19K-LPU-CC08 - H3C CR 8-Port100GEthernetoptical interface Module(CFP2) |
| 0231ADQG | CR-19K-LPU-CQ06B - H3C CR 6-Port100GEthernet Optical Interface ModuleB(QSFP28) |
| 0231A8FA | CR-19K-LPU-CC04B - H3C CR 4-Port100GEthernetoptical interface ModuleB(CFP2) |
| 0231AK8K | CR-19K-LPU-CQ12C - H3C CR 12-Port 100GEthernetoptical interface ModuleC (QSFP28) |
| 0231A8JL | CR-19K-LPU-CC04 - H3C CR 4-Port100GEthernetoptical interface Module(CFP2) |
| 0231A6EL | 0231A6EL - H3C CR 4-Port100GEthernetoptical interface Module(CFP2) |
| 0231A8FC | CR-19K-LPU-XP72 - H3C CR 72-Port10GEthernet Optical Interface Module(SFP+) |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231AHVB | CR-19K-LPU-CDQ02 - H3C CR 2-Port400GEthernet Optical Interface Module(QSFP-DD) |
| QSFP-DD Port | |
| 0231A8F8 | CR-19K-LPU-XP48 - H3C CR 48-Port10GEthernet Optical Interface Module(SFP+) |
| 0231AK8M | CR-19K-LPU-CDQ04 - H3C CR 4-Port 400GEthernetoptical interface Module(QSFP-DD) |
| 0231A8JJ | CR-19K-LPU-XP40 - H3C CR 40-Port10GEthernetoptical interface Module(SFP+) |
| 0231A8JM | CR-19K-LPU-XP20CC02 - H3C CR 20-Port10G(SFP+)+2-Port100G(CFP2)Ethernetoptical interface Module |
| 0231A8F9 | CR-19K-LPU-SP - H3C CR Flexible Service Processing Module (LPU-SP) |
| Power Supply Options | |
| 0231A5UW | CR-PEM-AC3000 - AC3000WPower Shelf |
| Dedicated Power Supply for Power Shelf | |
| 0231A5V0 | PSR3000B-54AHD - AC 3000W Power Module (supports high voltage DC) |
| Power Shelf Power Supply Cable | |
| 0404A0C2 | CAB-AC Pwr 3C-3m-PDU - PDU Power Supply Cable—3.0 m—3 × 1.5 mm²—Black—(C20 Connector (3P) Straight Male, 250 V, 16 A)—(227 IEC 53 (RVV))—(C19 Connector (3P) Straight Female, 250 V, 16 A)—GB Standard |
| 04043396 | CAB-AC Pwr CHI-3m - Wall-Mount AC power Cable - 3.0 m - 3 × 1.5 mm² - Black - (GB1002 Plug (3P), Angled Male, 250 V, 16 A) - (227 IEC 53 (RVV)) - (C19 Connector (3P), Straight Female, 250 V, 16 A) - National Standard |
| 0404A13W | CAB-AC POWER 3C-5.0m-PDU - PDU Power Supply Cable—5.0 m—3 × 1.5 mm²—Black—(C20 Connector (3P) Straight Male, 250 V, 16 A)—(227 IEC 53 (RVV))—(C19 Connector (3P) Straight Female, 250 V, 16 A)—GB Standard |
| 0404A19G | 0404A19G - AC3000WPower Shelf |
| 0404A0MW | CAB-AC-16A-PDU-3m-Eu - PDU Power Supply Cable - 3.0 m - 1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (H05VV-F) - (C19 Connector (3P) Straight Female 250 V 16 A) - European Standard |
| 0404A0GE | CAB-HVDC-16A-PDU-3m-Y - PDU Power Supply Cable - 3.0 m - 3 × 1.5 mm² - Yellow 121C - (C20 Connector (3P) Straight Male 250V 16A) - (227 IEC 53 (RVV)) - (C19 Connector (3P) Straight Female 250V 16A) - Chinese Standard |
| 0404A0LH | CAB-HVDC-16A-PDU-5m-Y - PDU Power Supply Cable - 5.0 m - 3 × 1.5 mm² - Yellow 121C - (C20 Connector (3P) Straight Male 250V 16A) - (227 IEC 53 (RVV)) - (C19 Connector (3P) Straight Female 250V 16A) - Chinese Standard |
| 0231A5UX | CR-PEM-DC2000 - DC2000WPower Shelf |
| 0231A5XA | PSR2400-54A-XC - H3C 2400W AC power Module |
| 0231A5V1 | PSR2000B-54D - DC2000WPower Module |
| 1417A00K | TER-JG2-22-5-90-Tin - JG2-22-5-90-Tinned (includes 1 x terminal) |
| 0404A0TN | CAB-DC PWR-25m-2*JG2 - Single Cable - External DC power Cable - 25m - (2*JG2(22-5-90)) - (RVVZ-0.6 kV/1.0 kV-25 mm² black + RVVZ-0.6 kV/1.0 kV-25 mm² blue)-(2*T(25-16) green + 2*T(25-16) green! + 2*OT(25-6-0)!) |
| 0404A0TP | CAB-DC PWR-35m-2*JG2 - Single cable—external DC power line—35 m—(2× JG2 (22.2-5-90))— (RVVZ-0.6 kV/1.0 kV-35 mm² black + RVVZ-0.6 kV/1.0 kV-35 mm² blue)-(2*T(33-18) beige + 2*T(33-18) beige! + 2*OT(35-6-0)!) |
| 0404A0TY | CAB-DC PWR-5m-2*JG2 - Single-strand cable—external DC power line—5 m—(2*JG2(25-5-90))—(4UL10455 black + 4UL10455 blue)—(2*T(25-16) brown + 2*T(25-16) brown! + 2OT(25-6-0)!) |
| 0231A5UY | CR-PEM-HVDC3000 - High voltage DC 3000W power supply box |
| 0404A0U7 | CAB-HVDC PWR-1m-PW3C - 336V High-Voltage DC power Cable - 1 m - (PW3C-16A 450V) - (227 IEC 53 (RVV) 3×1.5 mm² Black) - (2×T1508 Red + OT (2.5-6-0)) |
| 0404A0RL | CAB-HVDC Pwr-3m-336V - 336V High-Voltage DC power Cable - 3 m - 3 × 1.5 mm² - Black - (PW3C-16A 450V) - (227 IEC 53 (RVV) 3 × 1.5 mm² Black) - (3 × T1.5 mm² - 8 Red + 3 × OT (2.5-6-0)!) |
| 0404A0RP | CAB-PDU Pwr-3m-PW3C450V - PDU Power Supply Cable - 3.0 m - 3×1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (227 IEC 53 (RVV)) - (HVDCB Connector (3P) Straight Female 250 V 16 A) - National Standard |
| 0404A0RQ | CAB-AC-Pwr-3m-PW3C450V - Wall-Mounted AC power Cable - 3.0 m - 3 × 1.5 mm² - Black - (GB1002 Plug (3P), Angled Male, 250 V, 16 A) - (227 IEC 53 (RVV)) - (HVDCB Connector (3P), Straight Female, 250 V, 16 A) - National Standard |
| license certificate | |
| 3130A2QM | LIS-CR19000-STANDARD - H3C CR19000 Chassis Software Comware 7 Standard Edition License Certificate |
| Service Options | |
| 8814A0M7 | SV-PS-TS-CRSDS - Core Router Software Deployment Service |
| 8814A0SJ | SV-PS-FS-CRCDS - Core Router Cluster Deployment Service |
| Rack Rail | |
| 0231A4EK | LSXM1BSR - 1U Adjustable Rack Rail—630 mm to 900 mm |
| Fan | |
| 0231A5UV | FAN-120B-1-A - Fan Frame Module A |
| Dust-proof Door | |
| 0231A7MC | AF-41U-850-A - H3C Dust-Proof Door (41U, 850 mm high, 850 mm deep) |
| 2110A08W | AF-DUSTA - Dust-proof Sponge Assembly |
| Cabinet | |
| 0235A3JD | RACK-47U612-AX - H3C 47U AX-Type Network Cabinet |
| Cabinet Components | |
| 2115A03P | RACK-CE-DP-B - DP Cabinet Mounting Bracket, Component B (410 mm–700 mm) |
| Accessories | |
| 0231A8Y8 | PDU-96A-6C19 - PDU Module (96A Input, 6 C19 Outlets) |
| 0404A0TR | 0404A0TR - CR19000Routers |
| 0404A0TQ | 0404A0TQ - CR19000Routers |
| 0404A0TW | 0404A0TW - CR19000Routers |
| 0404A0TS | 0404A0TS - CR19000Routers |
| 0404A0TX | 0404A0TX - CR19000Routers |
| 0404A0U0 | 0404A0U0 - CR19000Routers |
| 0231A8YA | TB-24IN-24OUT - Power Distribution Terminal Block Module (24-input, 24-output) |
| Memory | |
| 0231A7R5 | DDR3 SODIMM-16GB-1600-2R*8 - DDR3 SODIMM 16GB Memory Module |
| Product Identity | |
| Brand | H3C |
| Series | H3C CR19000 Series Router |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Switching Capacity specification for CR19000-20?
What is the Whole Machine Packet Forwarding Rate specification for CR19000-20?
What is the Dimensions (W×D×H) specification for CR19000-20?
What is the Number of master control slots (MPUs) specification for CR19000-20?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?