| Key Specifications |
|---|
| Switching Capacity | 387.07Tbps |
| Whole Machine Packet Forwarding Rate | 172800Mpps |
| Dimensions (W×D×H) | 440mm x 650mm x 843mm, height approx. 19RU |
| Number of master control slots (MPUs) | 2 |
| Power Supply | Single frame 8 power independent modules, support redundancy backup, support intelligent power management |
| Number of network board slots (SFU) | 6 |
| Product Specifications |
|---|
| Number of master control slots (MPUs) | 2 |
| Number of network board slots (SFU) | 6 |
| Number of Line Card Slots (LPU) | 8 |
| Switching Capacity | 387.07Tbps |
| Whole Machine Packet Forwarding Rate | 172800Mpps |
| Routing Capacity (RIB) | >4 million entries |
| Power Supply | Single frame 8 power independent modules, support redundancy backup, support intelligent power management |
| Fan | Single-frame 6-fan module, support redundant backup, support intelligent cooling function |
| Dimensions (W×D×H) | 440mm x 650mm x 843mm, height approx. 19RU |
| Ambient temperature | Operation: 0°C to 45°C |
| Ambient humidity | Operating: 5% to 95%, non-condensing |
| Altitude | -60m~5000m |
| Interface Type | Supports GE, 10GE, 40GE, 50GE, 100GE, 400GEInterface Supports 50G FlexE, 100G FlexEInterface Supports 10G\2.5G\622M\155M POSInterface Supports 155M CPOSInterface |
| EMC | FCC Part 15 (CFR 47) CLASS AICES-003 CLASS A VCCI-3 CLASS A VCCI-4 CLASS A CISPR 22 CLASS A EN 55022 CLASS A AS/NZS CISPR22 CLASS A CISPR 24EN 55024EN 61000-3-2EN 61000-3-3EN 61000-6-1ETSI EN 300 386 |
| Safety regulations | UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1/A11AS/NZS 60950EN 60825-1EN 60825-2FDA 21 CFR Subchapter J GB 4943 |
| Link Layer Characterization | Supports link layer encapsulation protocols such as Ethernet, PPP, and HDLC Supports Layer 2 Ethernet and Layer 3 Ethernet Supports Layer 2 Ethernet aggregation and Layer 3 Ethernet aggregation Supports MP and HDLC bundling Supports QinQ and DOT1Q termination |
| ACL | Basic ACL (matches source IP address) Advanced ACL (matches Layer 3 and Layer 4 information) Layer 2 ACL (matches Layer 2 information) Time period-based ACLs Port ACLs, Global ACLs Support for ACL online updates Support for ACL counting |
| IPv4 protocols | TCP, UDP, RawIP, Ping Telnet, FTP, TFTPICMPv4DNSDHCPNATARP, ARP Proxy Policy Routing Port-based Route Scheduling Policy Supports Multi-Layer Repeat Matching |
| IPv6 protocols | IPv4/IPv6 Dual Protocol Stack TCP6, UDP6, RawIP6, Pingv6, Trace Route6Telnet6, FTP6, TFTP6DNS6ICMPv6VRRPv3DHCP6NAT64NDPMTUD(IPv6)6PE6VPEIPv6 Policy Routing Port-based Route Scheduling Policy support Multi-layer duplicate matching Support for ICMPv6 MIB, UDP6 MIB, TCP6 MIB, IPv6 MIBSupport for IPv4 to IPv6 transition technologies, including but not limited to manually configured tunnels, auto-configured tunnels, 6to4 tunnels, IPv6 over IPv4 tunnels, IPv4 over IPv6 tunnels, IPv6 over IPv6 tunnels, GRE over IPv6 tunnels, ISATAP tunnels, and so on. |
| IPv4Routing Protocols | RIPv1/v2OSPFv2IS-ISBGPv4BMPFlowspecIPv4static routingrouting policyroute recursion |
| IPv6Routing Protocols | RIPngOSPFv3IS-IS6BGPv4+BMPFlowspecIPv6static routingIPv6routing policyIPv6route recursion |
| Layer 3 multicast | Multicast Static Routing IPv4 Intra-Domain Multicast Routing IPv4 Inter-Domain Multicast Routing IPv4 Multicast Group Management IPv6 Intra-Domain Multicast Routing IPv6 Multicast Group Management Multicast VPNNG-MVPN |
| Interconnection Characteristics | Support for tunneling technologies such as VXLAN, GRE |
| MPLS Features | LDP LSP, RSVP-TEMPLS VPWS/VPLS/L3VPNRSVP TEP2MPPWE3MPLS OAMMPLS QoS Tunnel Policy |
| EVPN | EVPN VXLANEVPN VPWSEVPN VPLSEVPN L3VPNEVPN Data Center Interconnect Support for EVPN Tunnel TI-LFA Protection Support for EVPN L2VPN Access L3VPN over SR and SRv6 TE Policy Support for EVPN L3VPN, EVPN VPWS, EVPN VPLS Speed Limit Functionality Supports differential service priority tagging for EVPN L3VPN, EVPN VPWS, and EVPN VPLS. |
| SDN Features | NETCONFBGP-LSOpen FlowPCEPTelemetry supports intelligent WAN tuning algorithms in conjunction with controllers to support on-demand deployment and online adjustment of service bandwidth. |
| Segment Routing | SR BE, SR TE, SR TE Policy, support hot backup SR OAM, including MPLS SR ping tracert, bfd for lsp, tunnel, and other BFD probe linkage functions IGP protocol dynamic allocation SIDBGP protocol dynamic allocation SIDBGP EPE allocation SIDTI-LFA and anti-microloop SR TE Policy traffic statistics SR support label bonding binding SID support SR primary and backup paths, primary and backup tunnel protection and failure escape to BE function support L3VPN, EVPN L3VPN HoVPN VPNv4/VPNv6 over SR BE/SR-TE/SR TE Policy support L3VPN, EVPN L3VPN over SR BE/SR-TE/SR TE Policy Class A, Class B, Class C cross-domain support EVPN VPWSover SR BE/SR-TE/SR TE Policy, support dual attribution single active/dual active |
| SRv6 Features | SRv6 BE, SRv6 TE Policy, support for hot backup SRv6 OAM, include include ping tracert, sbfd for locator, srv6-policy, and other BFD probing linkage functions TI-LFA and anti-microloop SRv6 TE Policy traffic statistics SRv6 support for label bonding binding SIDSRv6 SFC supports SRv6 Policy UCMP and ECMP support APN6 function supports multiple candidate paths in SRv6 Policy to select the primary path according to priority, and also supports multiple Segment List according to the Weight attribute for the proportional distribution of traffic loads Support L3VPN, EVPN L3VPN HoVPN VPNv4/VPNv6 over SRv6 BE/SRv6 TE Policy Supports EVPN VPWS over SRv6 BE/SRv6 TE Policy, dual-attributed single-activity/dual-activity SRv6 TE Policy Supports BSID-based, Color-based, DSCP-based, CBTS-based, BGP-based, Flowspec-based, policy route-based, and policy route-based. Flowspec, policy routing and other flexible traffic diversion methods support SRv6 sampling, support for SRv6 tunnel inner layer message sampling support SRv6, can be upgraded through the software to meet the industry's latest standard features support for BGP SRv6 EPE, BGP-LS for SRv6 EPE support for controllers through the BGP automation of the issuance of SRv6TEPolicy supports cross-AS domain controllers to calculate end-to-end routes, realizing the cross-domain SRv6 function. |
| Device Security | Prevents single packet attacks Prevents scanning attacks Prevents flooding attacks Prevents TCP fragmentation attacks Prevents DOS/DDOS attacks Supports attack detection features Protocol message protection Message sending and receiving diagnostics Supports Control Plane Rate Limiting (COPP) Supports traffic monitoring by port mirroring Supports remote port mirroring Supports ACL traffic filtering and blackhole routing traffic blocking |
| Network Security | Message Legitimacy Check URPF Check Message Filtering Functions Prevent Data Message Attacks Prevent Protocol Message Attacks Prevent Protocol Message Attacks ARP Attacks Defend against ND Attacks Defend against BGP Attacks Defend against Protocol Classification Flow Restriction IPsecSSHSSLSAVI (Source Address Validity Verification) SAVNET (Intra-Domain Inter-Domain Source Address Verification Architecture Protocol) SMA (State Machine Based Forged Source Address Checking) Support FC- BGP Features |
| User Security | Device Management Security Network User Binding AAARBAC (Role Based Access Control) RADIUS, TACACS+ protocols supported |
| Device Management Method | Support SNMPv1/v2/v3 can be logged into the router through the Console port to for CLI configuration Support Telnet to this device to perform device management in a command line manner Support s Telnet (SSH) to this device to perform device management in a command line manner |
| Document Management | Support FTP/TFTP upload, download file support formatting, support file, directory creation, copy, delete, save file management functions |
| Network Maintenance | Ping Trace RouteLSP Ping/Tracert Port Loop Monitoring |
| Network Management | Network Management Platform iMCLLDP/LLDP-MEDMIB Synchronized Ethernet PTPNTPNet Stream Supports BGP-LS to collect network TOPO information Supports Twamp-Light to detect links, L3VPN latency, jitter, packet loss Supports 1731 to detect L2VPN latency, jitter, packet loss Supports EVPN VPWS, EVPN VPLS PW statistics and AC statistics support NQA, TWAMP, 2544, iFIT and other traffic detection technologies iFIT includes end-to-end detection, hop-by-hop detection of service delay, packet loss statistics, support for performance data obtained through telemetry uploads |
| Reliability | Master-Backup Reversal Online Hot Patch Uninterruptible Software Upgrade GRNSRVRRP, VRRPEBFD for VRRP/BGP/IS-IS/RIP/OSPF/Static Routing/SR/SRv6IP/IPv6/LDP/TE/VPN/VPNv6 FRR Non-Stop Forwarding (NSF) TI-LFA FRRDLDP BER Reversal Link Aggregation (Eth-Trunk), ECMP, UCMP and other cross-device link aggregation (S-Trunk) ETH OAM, CFD, Y.1731 All key modules (including the main control board, switching boards, service boards, power supplies, fans) are redundant, hot-swappable, and hot-swapping of key modules does not affect the normal operation of other components. A mother card supports a maximum of 4 daughter cards, mother card and daughter card can be hot-swappable support for cluster deployment, support for virtualization of two physical devices into a logical device, the cluster can achieve a consistent forwarding table entries, unified management, link aggregation across the physical device Mean Time Between Failure (MTBF) is greater than 12 years, the average time to repair (MTTR) is not more than 0.5 hours |
| Network Slicing | FlexEFlex-Algo sub-interface slicing Slice ID slicing supports SRv6 services carried on network hard slices |
| Deterministic network | Supports Det Net deterministic network technology with end-to-end latency of less than 20 microseconds |
| Catalog Description |
|---|
| Description | H3C CR19000-8 Router Chassis |
| Key Features |
|---|
| Feature 1 | Ultra-large Capacity, Unlimited Expansion and Upgrade The CR19000 is designed based on a T+ class platform and adopts the advanced fourth-generation non-blocking CLOS switching architecture, which realizes ultra-high-speed and low-latency forwarding of data within the clustering system. |
| Feature 2 | At the same time, the switching network supports variable-length element switching to effectively improve the operational efficiency of the entire cluster system |
| Feature 3 | CR19000 takes the lead in adopting high-speed cable backplane, breaking through the bottleneck of traditional PCB backplane and greatly increasing the capacity of the whole machine |
| Feature 4 | Adoption of high-performance network processing chips enables higher integration and lower power consumption of Service Module cards |
| Feature 5 | The CR19000 supports back-to-back and multi-frame clustering, up to 3+12 clusters, and can be continuously upgraded and expanded to 72-frame clusters in the future. |
| Ordering Information |
|---|
| Base Configuration | |
| 0235A3JB | CR19000-8; H3C CR19000-8 Router Chassis |
| Main Control Engine Board | |
| 0231A8UW | CR-19K-MPU-08A; H3C CR19000-8 Supervisor Engine ModuleA; Type: Main Control Engine Board |
| SFP Gigabit Port | |
| 0231A563 | SFP-GE-LX-SM1310-A; Single-mode SFP GE optical module (1310 nm, 10 km, LC); Type: SFP Gigabit Port |
| 0231A962 | SFP-GE-LX-SM1310-D; Single-mode SFP GE optical module (1310 nm, 10 km, LC); Type: SFP Gigabit Port |
| 0231A562 | SFP-GE-SX-MM850-A; Multi-mode SFP-GE optical module (850 nm, 0.55 km, LC); Type: SFP Gigabit Port |
| 0231A961 | SFP-GE-SX-MM850-D; Multi-mode SFP-GE optical module (850 nm, 0.55 km, LC); Type: SFP Gigabit Port |
| Main Control Engine Board | |
| 0231AC9M | CR-19K-MPU-08B; H3C CR19000-8 Supervisor Engine ModuleB; Type: Main Control Engine Board |
| 0231AKVR | CR19000Routers; Type: Main Control Engine Board |
| Mesh Board | |
| 0231A8GU | CR-19K-MSFU-08A; H3C CR19000-8 Cluster Switching Fabric Board (Class A); Type: Mesh Board |
| QSFP+ Port | |
| 0231A3U4 | QSFP-40G-D-AOC-10M; 40G QSFP+ to 40G QSFP+10m AOC; Type: QSFP+ Port |
| 0231A3U5 | QSFP-40G-D-AOC-20M; 40G QSFP+ to 40G QSFP+20m AOC; Type: QSFP+ Port |
| QSFP28-Port | |
| 0231A4B3 | QSFP-100G-D-AOC-10M; 100G QSFP28 to 100G QSFP28 10m AOC; Type: QSFP28-Port |
| 0231A4B4 | QSFP-100G-D-AOC-20M; 100G QSFP28 to 100G QSFP28 20m AOC; Type: QSFP28-Port |
| Mesh Board | |
| 0231A8V1 | CR-19K-SFU-08C; H3C CR19000-8 Standalone Switching Network Board (Class C); Type: Mesh Board |
| Business Processing Unit (Master Card) | |
| 0231ADUR | CR-19K-LPU-8004; Type: Business Processing Unit (Master Card) |
| Ethernet Interface Daughter Card Module | |
| 0231ADUS | CR-HIC-CQ02; H3C CR 2-Port 100G Ethernet Optical Interface Daughter Card (QSFP28); Type: Ethernet Interface Daughter Card Module |
| QSFP Port | |
| 0231AFJA | QSFP-100G-ZR4-WDM1300; 100G QSFP28 Optical Module (1300nm, 80km, ZR4, WDM, LC); Type: QSFP Port |
| 0231A4UF | QSFP-100G-LR4-WDM1300; 100G QSFP28 Optical Module (1310nm, 10km, LR4, WDM, LC); Type: QSFP Port |
| 0231A5LL | QSFP-100G-LR4L-WDM1300; 100G QSFP28 Optical Module (1310nm, 2km, LR4L, CWDM4, LC); Type: QSFP Port |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300; 100G QSFP28 Optical Module (1310nm, 40km, ER4L, WDM, LC); Type: QSFP Port |
| 0231A5UL | QSFP-100G-eSR4-MM850; 100G QSFP28 Optical Module (850nm, 300m OM4, eSR4, MPO); Type: QSFP Port |
| 0231A4B1 | QSFP-100G-SR4-MM850; 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO); Type: QSFP Port |
| 0231A2E4 | QSFP-40G-LR4-WDM1300; QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC); Type: QSFP Port |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850; QSFP+ 40G BIDI Optical Module (850nm, 100m, SR); Type: QSFP Port |
| 0231A4UG | QSFP-40G-ER4-WDM1300; QSFP+ 40G Optical Module (1310nm, 40km, ER4, LC); Type: QSFP Port |
| 0231A2NF | QSFP-40G-SR4-MM850; Type: QSFP Port |
| 0231A2KL | QSFP-40G-CSR4-MM850; Type: QSFP Port |
| Ethernet Interface Daughter Card Module | |
| 0231AAQJ | CR-HIC-CQ01; H3C CR 1-port 100G Ethernet Optical Interface daughter card (QSFP28); Type: Ethernet Interface Daughter Card Module |
| 0231AF5Y | CR-HIC-CLGQ04F; Type: Ethernet Interface Daughter Card Module |
| 0231A3YJ | CR-HIC-XP12; H3C CR 12-Port 10G Ethernet Optical Interface Daughter Card (SFP+); Type: Ethernet Interface Daughter Card Module |
| SFP+ Optical Module | |
| 0231A0A8 | SFP-XG-LX-SM1310; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP+ Optical Module |
| 0231A1RP | SFP-XG-SX-MM850-D; SFP+ 10G Module (850nm, 300m, LC); Type: SFP+ Optical Module |
| 0231A1RQ | SFP-XG-LX-SM1310-D; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP+ Optical Module |
| 0231A1RR | SFP-XG-LH40-SM1550-D; SFP+ 10G Module (1550nm, 40km, LC); Type: SFP+ Optical Module |
| 0231A2T6 | SFP-XG-LH80-SM1550-D; SFP+ 10G Module (1550nm, 80km, LC); Type: SFP+ Optical Module |
| 0231A1PA | SFP-XG-LH80-SM1550; SFP+ 10G Module (1550nm, 80km, LC); Type: SFP+ Optical Module |
| 0231A0SP | SFP-XG-LH40-SM1550; SFP+ 10G Module (1550nm, 40km, LC); Type: SFP+ Optical Module |
| 0231A2L4 | SFP-XG-SX-MM850-E; SFP+ 10G Module (850nm, 300m, LC); Type: SFP+ Optical Module |
| 0231A2L3 | SFP-XG-LX-SM1310-E; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP+ Optical Module |
| Ethernet Interface Daughter Card Module | |
| 0231AE0L | CR-HIC-XP12B; H3C CR 12-Port 10G Ethernet Optical Interface Daughter Card (SFP+); Type: Ethernet Interface Daughter Card Module |
| SFP+ 10G Port | |
| 02312173 | SFP-GE-LH80-SM1550; Single-mode SFP optical module (1550 nm, 80 km, LC); Type: SFP+ 10G Port |
| 02312170 | SFP-GE-LH40-SM1310; Single-mode SFP GE optical module (1310 nm, 40 km, LC); Type: SFP+ 10G Port |
| 0231A085 | SFP-GE-T; SFP GE Electrical Port Module (100m, RJ45); Type: SFP+ 10G Port |
| 0231A960 | SFP-GE-T-D; SFP GE Electrical Port Module (100m, RJ45); Type: SFP+ 10G Port |
| 0231A963 | SFP-GE-LH40-SM1310-D; Single-mode SFP GE optical module (1310 nm, 40 km, LC); Type: SFP+ 10G Port |
| 02312172 | SFP-GE-LH40-SM1550; Single-mode SFP optical module (1550 nm, 40 km, LC); Type: SFP+ 10G Port |
| 0231A964 | SFP-GE-LH80-SM1550-D; Single-mode SFP optical module (1550 nm, 80 km, LC); Type: SFP+ 10G Port |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI; SFP+ 10GBIDI Optical Module (TX 1270nm/RX 1330nm, 40km, LC); Type: SFP+ 10G Port |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI; SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC); Type: SFP+ 10G Port |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI; SFP+ 10GBIDI Optical Module (TX 1330nm/RX 1270nm, 40km, LC); Type: SFP+ 10G Port |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI; SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC); Type: SFP+ 10G Port |
| Ethernet Interface Daughter Card Module | |
| 0231AC9N | CR-HIC-XP10; H3C CR 10-Port 1G/10G Ethernet Optical Interface Daughter Card (SFP+); Type: Ethernet Interface Daughter Card Module |
| Business Processing Unit (Master Card) | |
| 0231A8JK | CR-19K-LPU-4004; Type: Business Processing Unit (Master Card) |
| HIC Interface Modules | |
| 0231A4PF | CR-HIC-CC01; H3C CR 1-port 100G Ethernet Optical Interface daughter card (CFP2); Type: HIC Interface Modules |
| CFP2-Port | |
| 0231A3FF | CFP2-100G-LR4-WDM1300; CFP2 100G Optical Module (10KM, SM, LR4); Type: CFP2-Port |
| HIC Interface Modules | |
| 0231A3YH | CR-HIC-QQ03; H3C CR 3-Port 40G Ethernet Optical Interface Daughter Card (QSFP+); Type: HIC Interface Modules |
| 0231A4PG | CR-HIC-GP12; H3C CR 12-Port Gigabit Ethernet Optical Interface Daughter Card (SFP); Type: HIC Interface Modules |
| Gigabit Optical Module | |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI; SFP GigabitBIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC); Type: Gigabit Optical Module |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI; SFP GigabitBIDI Optical Module (TX 1550 nm/RX 1310 nm, 40 km, LC); Type: Gigabit Optical Module |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI; SFP GigabitBIDI Optical Module (TX 1490 nm/RX 1550 nm, 70 km, LC); Type: Gigabit Optical Module |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI; SFP GigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC); Type: Gigabit Optical Module |
| HIC Interface Modules | |
| 0231A4PH | CR-HIC-PU02; Type: HIC Interface Modules |
| XFP Optical Module | |
| 0231A1RV | Type: XFP Optical Module |
| 0231A72X | XFP-LH40-SM1550-F1; XFP10G Optical Module (1550nm, 40km, LC); Type: XFP Optical Module |
| 0231A1RU | Type: XFP Optical Module |
| 0231A04G | XFP-POS-LH10-SM1310; Optical Module-XFP-10G POS-Single-mode Module (1310nm, 10km, LC); Type: XFP Optical Module |
| 0231A41G | XFP-LH80-SM1550; Optical Module-XFP-10G-Single-mode Module (1550nm, 80km, LC); Type: XFP Optical Module |
| HIC Interface Modules | |
| 0231A8JD | CR-HIC-PS04; Type: HIC Interface Modules |
| Fast Ethernet Optical Module | |
| 0231A090 | SFP-FE-LH80-SM1550; Optical Module-SFP 100M/155M Single-mode Long-Reach Module (1550nm, 80km, LC); Type: Fast Ethernet Optical Module |
| 0231A564 | SFP-FE-LX-SM1310-A; Single-mode SFP 100M/155M optical module (1310 nm, 15 km, LC); Type: Fast Ethernet Optical Module |
| 0231A320 | SFP-FE-SX-MM1310-A; Optical Module-SFP 100M/155M-Multimode Module (1310nm, 2km, LC); Type: Fast Ethernet Optical Module |
| 0231A965 | SFP-FE-LX-SM1310-D; Single-mode SFP 100M/155M optical module (1310 nm, 15 km, LC); Type: Fast Ethernet Optical Module |
| 0231A089 | SFP-FE-LH40-SM1310; Single-mode SFP 100M/155M optical module (1310 nm, 40 km, LC); Type: Fast Ethernet Optical Module |
| 622M Optical Module | |
| 0231A40D | Type: 622M Optical Module |
| 0231A40B | SFP-622M-LX-SM1310; 622M SFP Optical Module (1310nm, 15km, LC); Type: 622M Optical Module |
| 2.5G Optical Module | |
| 0231A03Y | Type: 2.5G Optical Module |
| 0231A03X | SFP-2.5G-LX-SM1310; Optical Module-SFP-2.5G-Single-mode Module (1310nm, 2km, LC); Type: 2.5G Optical Module |
| 0231A04A | Type: 2.5G Optical Module |
| HIC Interface Modules | |
| 0231ADFS | CR-HIC-PHP08; H3C CR 8-Port 622M/155M POS Optical Interface Daughter Card (SFP); Type: HIC Interface Modules |
| 0231ADFT | CR-HIC-CLP04; Type: HIC Interface Modules |
| 0231ADFR | CR-HIC-ET16; Type: HIC Interface Modules |
| Cable | |
| 0231A2GG | SR0M7CAB2; H3C_SEG_0 HM-96pin E1 Cable (120 Ohm, 3m, RJ45); Type: Cable |
| 0231A2GF | SR0M7CAB1; H3C_SEG_0 HM-96pin E1 Cable (75 Ohm, 3m, BNC); Type: Cable |
| 0231A2GH | SR0M7CAB3; HM-96-pin E1 Cable (75 ohms, 3 m, SMB); Type: Cable |
| Business Processing Unit (Master Card) | |
| 0231A8JG | CR-19K-LPU-2002; Type: Business Processing Unit (Master Card) |
| 0231A8FF | CR-19K-LPU-2002B; Type: Business Processing Unit (Master Card) |
| 0231AHM5 | CR-19K-LPU-4004B; H3C CR Flexible Interface Module B (LPU-4004B); Type: Business Processing Unit (Master Card) |
| 0231AHM6 | CR-19K-LPU-8004B; H3C CR Flexible Interface Module B (LPU-8004B); Type: Business Processing Unit (Master Card) |
| Service Module | |
| 0231A8FB | CR-19K-LPU-CQ18; Type: Service Module |
| multimode fiber | |
| 0231A8G4 | CR-19K-FIBER-10M-12; H3C CR19000 MSFU-20B Network Board Cluster Fiber Bundle (10m*12); Type: multimode fiber |
| 0231A8G5 | CR-19K-FIBER-10M-36; H3C CR19000 MSFU-20C Network Board Cluster Fiber Bundle (10 m × 36); Type: multimode fiber |
| 1413A014 | OP-MTP24-MTP24-OM3-70-M; Fiber Connector—MTP (24-fiber)/Low-Loss Female Connector—MTP (24-fiber)/Low-Loss Female Connector—Multimode (OM3)—3.8 mm—70 m; Type: multimode fiber |
| 1413A011 | OP-MTP24-MTP24-OM3-10-M; Fiber Connector—MTP (24-fiber)/Female—MTP (24-fiber)/Female—Multimode (OM3)—3.8 mm—10 m; Type: multimode fiber |
| 1413A010 | OP-MTP24-MTP24-OM3-30-M; Fiber Connector—MTP (24-fiber)/Female—MTP (24-fiber)/Female—Multimode (OM3)—3.8 mm—30 m; Type: multimode fiber |
| 1413A012 | OP-MTP24-MTP24-OM3-50-M; Fiber Connector—MTP (24-fiber)/Female—MTP (24-fiber)/Female—Multimode (OM3)—3.8 mm—50 m; Type: multimode fiber |
| 1413A00Y | OP-MTP24-MTP24-OM4-100-M; Fiber Connector—MTP (24-fiber)/Female—MTP (24-fiber)/Female—Multimode (OM4)—3.8 mm—100 m; Type: multimode fiber |
| Service Module | |
| 0231AAQH | CR-19K-LPU-CQ12B; H3C CR 12-Port 100G Ethernet Optical Interface Module B (QSFP28); Type: Service Module |
| 0231A8JH | CR-19K-LPU-CQ12; Type: Service Module |
| 0231A8JF | CR-19K-LPU-CC08; Type: Service Module |
| 0231ADQG | CR-19K-LPU-CQ06B; H3C CR 6-Port 100G Ethernet Optical Interface Module B (QSFP28); Type: Service Module |
| 0231A8FA | CR-19K-LPU-CC04B; H3C CR 4-Port 100G Ethernet Optical Interface Module B (CFP2); Type: Service Module |
| 0231AK8K | CR-19K-LPU-CQ12C; Type: Service Module |
| 0231A8JL | CR-19K-LPU-CC04; Type: Service Module |
| CFP2-Port | |
| 0231A6EL | Type: CFP2-Port |
| Service Module | |
| 0231A8FC | CR-19K-LPU-XP72; Type: Service Module |
| SFP+ 10G Port | |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI; SFP+ 10GBIDI Optical Module (TX 1270nm/RX 1330nm, 10km, LC); Type: SFP+ 10G Port |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI; SFP+ 10GBIDI Optical Module (TX 1330nm/RX 1270nm, 10km, LC); Type: SFP+ 10G Port |
| Service Module | |
| 0231AHVB | CR-19K-LPU-CDQ02; Type: Service Module |
| 0231A8F8 | CR-19K-LPU-XP48; Type: Service Module |
| 0231AK8M | CR-19K-LPU-CDQ04; Type: Service Module |
| 0231A8JJ | CR-19K-LPU-XP40; Type: Service Module |
| 0231A8JM | CR-19K-LPU-XP20CC02; H3C CR 20-Port 10G (SFP+) + 2-Port 100G (CFP2) Ethernet Optical Interface Module; Type: Service Module |
| 0231A8F9 | CR-19K-LPU-SP; H3C CR Flexible Service Processing Module (LPU-SP); Type: Service Module |
| Power Supply Options | |
| 0231A2X7 | PSR2400-54D; DC Power Supply Module-2400W; Type: Power Supply Options |
| 0231A5CH | PSR3000-54A; 3000W AC Power Supply Module; Type: Power Supply Options |
| 0231A5XA | PSR2400-54A-XC; H3C 2400W AC Power Supply Module; Type: Power Supply Options |
| license certificate | |
| 3130A2QM | LIS-CR19000-STANDARD; Type: license certificate |
| Service Options | |
| 8814A0M7 | SV-PS-TS-CRSDS; Core Router Software Deployment Service; Type: Service Options |
| 8814A0SJ | SV-PS-FS-CRCDS; Core Router Cluster Deployment Service; Type: Service Options |
| Rack Rail | |
| 0231A4EK | LSXM1BSR; 1U Adjustable Rack Rail—630 mm to 900 mm; Type: Rack Rail |
| Fan | |
| 0231A8US | FAN-120B-2-A; Type: Fan |
| Dust-proof Door | |
| 0231A7MB | AF-19U-640-B; H3C Dust-Proof Door (19U, 640 mm deep); Type: Dust-proof Door |
| 2110A08W | AF-DUSTA; Dust-proof Sponge Assembly; Type: Dust-proof Door |
| Cabinet | |
| 0235A3JD | RACK-47U612-AX; H3C 47U AX Series Network Cabinet; Type: Cabinet |
| Cabinet Components | |
| 2115A03P | RACK-CE-DP-B; DP Cabinet Mounting Bracket, Component B (410 mm–700 mm); Type: Cabinet Components |
| Accessories | |
| 0231A8Y8 | PDU-96A-6C19; PDU Module (96A input, 6 C19 outlet outputs); Type: Accessories |
| 0404A0TR | CR19000Routers; Type: Accessories |
| 0404A0TQ | CR19000Routers; Type: Accessories |
| 0404A0TW | CR19000Routers; Type: Accessories |
| 0404A0TS | CR19000Routers; Type: Accessories |
| 0404A0TX | CR19000Routers; Type: Accessories |
| 0404A0U0 | CR19000Routers; Type: Accessories |
| 0231A8YA | TB-24IN-24OUT; Power Distribution Terminal Block Module (24-channel input, 24-channel output); Type: Accessories |
| Memory | |
| 0231A7R5 | DDR3 SODIMM-16GB-1600-2R*8; DDR3 16GB SODIMM Memory Module; Type: Memory |
| Product Identity |
|---|
| Brand | H3C |
| Series | H3C CR1x000 Router |