Product Overview
The Juniper EX4400-48F-AFI is a high-performance network component designed for the EX4400-48F series.

Our CCIE certified engineers can help you verify compatibility.
Global logistics network aiming for same-day handover.
Every unit undergoes rigorous 38-point inspection test.
Trusted by enterprise clients across 6 continents.
Certified network engineers ready to assist with configuration.
The Juniper EX4400-48F-AFI is a high-performance network component designed for the EX4400-48F series.
| EX4400-48F — Overview | |
|---|---|
| Full Product Name | EX4400 Ethernet Switch |
| OS Supported | Junos OS |
| EX4400-48F — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.39 in / 44.1706 cm |
| Chassis Depth | 15.71 in / 39.9034 cm |
| Chassis Depth (With FRUs) | 17.35 in / 44.069 cm |
| Chassis Weight (Spare) | 12.79 lb / 5.8 kg |
| Chassis Model Number | EX4400-48F-S |
| EX4400-48F — Chassis Cluster/High Availability/Virtual Chassis | |
| Chassis Cluster/High Availability/Virtual Chassis Port Count | 2 |
| Chassis Cluster/High Availability/Virtual Chassis Port Type | QSFP28 |
| Count of Devices in Virtual Chassis | 10 |
| EX4400-48F — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Module Model Number | EX4400-FAN |
| Fan Module Count | 2 |
| Fan Module Redundancy | 1+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| EX4400-48F — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1829 m |
| Non-Operating Altitude | 16000 ft / 4877 m |
| Operating Temperature | 32° through 113° F / 0° through 45° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 90% |
| Seismic Tolerance | Zone 4 |
| Acoustic Noise Level (Max) | 43.35 dB |
| Maintenance Clearance | 30 in / 76.2 cm |
| EX4400-48F — Built-in Network Ports | |
| SFP Port Count | 36 |
| SFP Port - MACsec Support? | Y |
| SFP+ Port Count | 12 |
| SFP+ Port - MACsec Support? | Y |
| EX4400-48F — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Console Port 2 Count | 1 |
| Console Port 2 Type | Type C |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| EX4400-48F — Performance (Routing/Switching) | |
| Packet Switching Unidirectional (64B) | 456 Gbps |
| Packet Switching Bidirectional (64B) | 912 Gbps |
| L2/L3 Throughput (64B) | 678 Mpps |
| IPv4 Unicast Host Routes (Thousands) | 81 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 130 |
| IPv4 Multicast Routes (Thousands) | 40 |
| IPv6 Unicast Host Routes (Thousands) | 40 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 87 |
| IPv6 Multicast Routes (Thousands) | 20 |
| IPv6 Neighbor Discovery Entries (Thousands) | 12 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 1024 |
| Egress Routed ACL | 1024 |
| Ingress VLAN ACL | 2048 |
| Ingress Port ACL | 2048 |
| Ingress Routed ACL | 2048 |
| ARP Entries (Thousands) | 24 |
| MSTP Instances | 64 |
| VSTP Instances | 510 |
| LAGs Count | 128 |
| Ports Per LAG | 16 |
| MAC Addresses Per System (Thousands) | 112 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 1 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4093 |
| Jumbo Frame | 9216 bytes |
| QoS Hardware Queues Per Port (Multicast) | 4 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| EX4400-48F — Processor | |
| CPU | 2.2 GHz Quad-Core Intel x86 CPU |
| DRAM | 4 GB |
| EX4400-48F — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| AC PSU Model Number | JPSU-550-C-AC-AFO |
| Grounding Cable Lug Type | LCD8-AF-L, LCD10-AF-L |
| Grounding Cable Wire Gauge | 8 AWG / 14 AWG |
| EX4400-48F — Routing/Switching Hardware | |
| Uplink/Extension Module Slots | 1 |
| Uplink/Extension Modules Supported | EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S |
| EX4400-48F — Storage | |
| Internal Storage Size | 20 GB |
| EX4400-48F-AFI — Overview | |
| Full Product Name | EX4400 Ethernet Switch |
| OS Supported | Junos OS |
| EX4400-48F-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.39 in / 44.1706 cm |
| Chassis Depth | 15.71 in / 39.9034 cm |
| Chassis Depth (With FRUs) | 17.35 in / 44.069 cm |
| Chassis Weight (Spare) | 12.79 lb / 5.8 kg |
| Chassis Model Number | EX4400-48F-S |
| EX4400-48F-AFI — Chassis Cluster/High Availability/Virtual Chassis | |
| Chassis Cluster/High Availability/Virtual Chassis Port Count | 2 |
| Chassis Cluster/High Availability/Virtual Chassis Port Type | QSFP28 |
| Count of Devices in Virtual Chassis | 10 |
| EX4400-48F-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| AFO/AFI? | AFI |
| Fan Module Model Number | EX4400-FAN-AFI |
| Fan Module Count | 2 |
| Fan Module Redundancy | 1+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| EX4400-48F-AFI — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1829 m |
| Non-Operating Altitude | 16000 ft / 4877 m |
| Operating Temperature | 32° through 113° F / 0° through 45° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 90% |
| Seismic Tolerance | Zone 4 |
| Acoustic Noise Level (Max) | 44.79 dB |
| Maintenance Clearance | 30 in / 76.2 cm |
| EX4400-48F-AFI — Built-in Network Ports | |
| SFP Port Count | 36 |
| SFP Port - MACsec Support? | Y |
| SFP+ Port Count | 12 |
| SFP+ Port - MACsec Support? | Y |
| EX4400-48F-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Console Port 2 Count | 1 |
| Console Port 2 Type | Type C |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| EX4400-48F-AFI — Performance (Routing/Switching) | |
| Packet Switching Unidirectional (64B) | 456 Gbps |
| Packet Switching Bidirectional (64B) | 912 Gbps |
| L2/L3 Throughput (64B) | 678 Mpps |
| IPv4 Unicast Host Routes (Thousands) | 81 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 130 |
| IPv4 Multicast Routes (Thousands) | 40 |
| IPv6 Unicast Host Routes (Thousands) | 40 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 87 |
| IPv6 Multicast Routes (Thousands) | 20 |
| IPv6 Neighbor Discovery Entries (Thousands) | 12 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 1024 |
| Egress Routed ACL | 1024 |
| Ingress VLAN ACL | 2048 |
| Ingress Port ACL | 2048 |
| Ingress Routed ACL | 2048 |
| ARP Entries (Thousands) | 24 |
| MSTP Instances | 64 |
| VSTP Instances | 510 |
| LAGs Count | 128 |
| Ports Per LAG | 16 |
| MAC Addresses Per System (Thousands) | 112 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 1 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4093 |
| Jumbo Frame | 9216 bytes |
| QoS Hardware Queues Per Port (Multicast) | 4 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| EX4400-48F-AFI — Processor | |
| CPU | 2.2 GHz Quad-Core Intel x86 CPU |
| DRAM | 4 GB |
| EX4400-48F-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| AC PSU Model Number | JPSU-550-C-AC-AFI |
| Grounding Cable Lug Type | LCD8-AF-L, LCD10-AF-L |
| Grounding Cable Wire Gauge | 8 AWG / 14 AWG |
| EX4400-48F-AFI — Routing/Switching Hardware | |
| Uplink/Extension Module Slots | 1 |
| Uplink/Extension Modules Supported | EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S |
| EX4400-48F-AFI — Storage | |
| Internal Storage Size | 20 GB |
| EX4400-48F-DC — Overview | |
| Full Product Name | EX4400 Ethernet Switch |
| OS Supported | Junos OS |
| EX4400-48F-DC — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.39 in / 44.1706 cm |
| Chassis Depth | 15.71 in / 39.9034 cm |
| Chassis Depth (With FRUs) | 17.35 in / 44.069 cm |
| Chassis Weight (Spare) | 12.79 lb / 5.8 kg |
| Chassis Model Number | EX4400-48F-S |
| EX4400-48F-DC — Chassis Cluster/High Availability/Virtual Chassis | |
| Chassis Cluster/High Availability/Virtual Chassis Port Count | 2 |
| Chassis Cluster/High Availability/Virtual Chassis Port Type | QSFP28 |
| Count of Devices in Virtual Chassis | 10 |
| EX4400-48F-DC — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Module Model Number | EX4400-FAN |
| Fan Module Count | 2 |
| Fan Module Redundancy | 1+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| EX4400-48F-DC — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1829 m |
| Non-Operating Altitude | 16000 ft / 4877 m |
| Operating Temperature | 32° through 113° F / 0° through 45° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 90% |
| Seismic Tolerance | Zone 4 |
| Acoustic Noise Level (Max) | 43.69 dB |
| Maintenance Clearance | 30 in / 76.2 cm |
| EX4400-48F-DC — Built-in Network Ports | |
| SFP Port Count | 36 |
| SFP Port - MACsec Support? | Y |
| SFP+ Port Count | 12 |
| SFP+ Port - MACsec Support? | Y |
| EX4400-48F-DC — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Console Port 2 Count | 1 |
| Console Port 2 Type | Type C |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| EX4400-48F-DC — Performance (Routing/Switching) | |
| Packet Switching Unidirectional (64B) | 456 Gbps |
| Packet Switching Bidirectional (64B) | 912 Gbps |
| L2/L3 Throughput (64B) | 678 Mpps |
| IPv4 Unicast Host Routes (Thousands) | 81 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 130 |
| IPv4 Multicast Routes (Thousands) | 40 |
| IPv6 Unicast Host Routes (Thousands) | 40 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 87 |
| IPv6 Multicast Routes (Thousands) | 20 |
| IPv6 Neighbor Discovery Entries (Thousands) | 12 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 1024 |
| Egress Routed ACL | 1024 |
| Ingress VLAN ACL | 2048 |
| Ingress Port ACL | 2048 |
| Ingress Routed ACL | 2048 |
| ARP Entries (Thousands) | 24 |
| MSTP Instances | 64 |
| VSTP Instances | 510 |
| LAGs Count | 128 |
| Ports Per LAG | 16 |
| MAC Addresses Per System (Thousands) | 112 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 1 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4093 |
| Jumbo Frame | 9216 bytes |
| QoS Hardware Queues Per Port (Multicast) | 4 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| EX4400-48F-DC — Processor | |
| CPU | 2.2 GHz Quad-Core Intel x86 CPU |
| DRAM | 4 GB |
| EX4400-48F-DC — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| DC PSU Model Number | JPSU-550-C-DC-AFO |
| Grounding Cable Lug Type | LCD8-AF-L, LCD10-AF-L |
| Grounding Cable Wire Gauge | 8 AWG / 14 AWG |
| EX4400-48F-DC — Routing/Switching Hardware | |
| Uplink/Extension Module Slots | 1 |
| Uplink/Extension Modules Supported | EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S |
| EX4400-48F-DC — Storage | |
| Internal Storage Size | 20 GB |
| EX4400-48F-DC-AFI — Overview | |
| Full Product Name | EX4400 Ethernet Switch |
| OS Supported | Junos OS |
| EX4400-48F-DC-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.39 in / 44.1706 cm |
| Chassis Depth | 15.71 in / 39.9034 cm |
| Chassis Depth (With FRUs) | 17.35 in / 44.069 cm |
| Chassis Weight (Spare) | 12.79 lb / 5.8 kg |
| Chassis Model Number | EX4400-48F-S |
| EX4400-48F-DC-AFI — Chassis Cluster/High Availability/Virtual Chassis | |
| Chassis Cluster/High Availability/Virtual Chassis Port Count | 2 |
| Chassis Cluster/High Availability/Virtual Chassis Port Type | QSFP28 |
| Count of Devices in Virtual Chassis | 10 |
| EX4400-48F-DC-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| AFO/AFI? | AFI |
| Fan Module Model Number | EX4400-FAN-AFI |
| Fan Module Count | 2 |
| Fan Module Redundancy | 1+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| EX4400-48F-DC-AFI — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1829 m |
| Non-Operating Altitude | 16000 ft / 4877 m |
| Operating Temperature | 32° through 113° F / 0° through 45° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 0% through 90% |
| Seismic Tolerance | Zone 4 |
| Acoustic Noise Level (Max) | 44.61 dB |
| Maintenance Clearance | 30 in / 76.2 cm |
| EX4400-48F-DC-AFI — Built-in Network Ports | |
| SFP Port Count | 36 |
| SFP Port - MACsec Support? | Y |
| SFP+ Port Count | 12 |
| SFP+ Port - MACsec Support? | Y |
| EX4400-48F-DC-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Console Port 2 Count | 1 |
| Console Port 2 Type | Type C |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| EX4400-48F-DC-AFI — Performance (Routing/Switching) | |
| Packet Switching Unidirectional (64B) | 456 Gbps |
| Packet Switching Bidirectional (64B) | 912 Gbps |
| L2/L3 Throughput (64B) | 678 Mpps |
| IPv4 Unicast Host Routes (Thousands) | 81 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 130 |
| IPv4 Multicast Routes (Thousands) | 40 |
| IPv6 Unicast Host Routes (Thousands) | 40 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 87 |
| IPv6 Multicast Routes (Thousands) | 20 |
| IPv6 Neighbor Discovery Entries (Thousands) | 12 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 1024 |
| Egress Routed ACL | 1024 |
| Ingress VLAN ACL | 2048 |
| Ingress Port ACL | 2048 |
| Ingress Routed ACL | 2048 |
| ARP Entries (Thousands) | 24 |
| MSTP Instances | 64 |
| VSTP Instances | 510 |
| LAGs Count | 128 |
| Ports Per LAG | 16 |
| MAC Addresses Per System (Thousands) | 112 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 1 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4093 |
| Jumbo Frame | 9216 bytes |
| QoS Hardware Queues Per Port (Multicast) | 4 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| EX4400-48F-DC-AFI — Processor | |
| CPU | 2.2 GHz Quad-Core Intel x86 CPU |
| DRAM | 4 GB |
| EX4400-48F-DC-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| DC PSU Model Number | JPSU-550-C-DC-AFI |
| Grounding Cable Lug Type | LCD8-AF-L, LCD10-AF-L |
| Grounding Cable Wire Gauge | 8 AWG / 14 AWG |
| EX4400-48F-DC-AFI — Routing/Switching Hardware | |
| Uplink/Extension Module Slots | 1 |
| Uplink/Extension Modules Supported | EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S |
| EX4400-48F-DC-AFI — Storage | |
| Internal Storage Size | 20 GB |
No reviews yet
Be the first to review this enterprise product.
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
Still have questions?