Product Overview
The Juniper EX4400-48F-AFI is a high-performance network component designed for the EX4400-48F series.
Key Specifications
- EX4400-48F: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Front-to-back’, ‘AFO/AFI?’: ‘AFO’, ‘Fan Module Model Number’: ‘EX4400-FAN’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘43.35 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Front-to-back’, ‘AC PSU Model Number’: ‘JPSU-550-C-AC-AFO’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
- EX4400-48F-AFI: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Back-to-front’, ‘AFO/AFI?’: ‘AFI’, ‘Fan Module Model Number’: ‘EX4400-FAN-AFI’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘44.79 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Back-to-front’, ‘AC PSU Model Number’: ‘JPSU-550-C-AC-AFI’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
- EX4400-48F-DC: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Front-to-back’, ‘AFO/AFI?’: ‘AFO’, ‘Fan Module Model Number’: ‘EX4400-FAN’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘43.69 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Front-to-back’, ‘DC PSU Model Number’: ‘JPSU-550-C-DC-AFO’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
- EX4400-48F-DC-AFI: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Back-to-front’, ‘AFO/AFI?’: ‘AFI’, ‘Fan Module Model Number’: ‘EX4400-FAN-AFI’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘44.61 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Back-to-front’, ‘DC PSU Model Number’: ‘JPSU-550-C-DC-AFI’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]







