ITMall,Your IT Global Procurement Service Expert
EX4400-48F-AFI
Brand Juniper
4.9Verified

EX4400-48F-AFI

Model (MPN)
EX4400-48F-AFI
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock
  • SKU: EX4400-48F-AFI
  • Base Model: EX4400-48F
  • Manufacturer: Juniper

Volume & Framework Pricing

B2B Only
QuantityUnit PriceEst. Savings
1 Unit$272.20-
2 - 9 UnitsRequest Quote5 - 10%
10+ / ProjectFramework Match Tier-1 Access
Global Framework Support AvailableGet Global Discount
Your Price
Call for Pricing
Volume discounts available
Availability Out of Stock

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

Product Overview

The Juniper EX4400-48F-AFI is a high-performance network component designed for the EX4400-48F series.

Key Specifications

  • EX4400-48F: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Front-to-back’, ‘AFO/AFI?’: ‘AFO’, ‘Fan Module Model Number’: ‘EX4400-FAN’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘43.35 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Front-to-back’, ‘AC PSU Model Number’: ‘JPSU-550-C-AC-AFO’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
  • EX4400-48F-AFI: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Back-to-front’, ‘AFO/AFI?’: ‘AFI’, ‘Fan Module Model Number’: ‘EX4400-FAN-AFI’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘44.79 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Back-to-front’, ‘AC PSU Model Number’: ‘JPSU-550-C-AC-AFI’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
  • EX4400-48F-DC: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Front-to-back’, ‘AFO/AFI?’: ‘AFO’, ‘Fan Module Model Number’: ‘EX4400-FAN’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘43.69 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Front-to-back’, ‘DC PSU Model Number’: ‘JPSU-550-C-DC-AFO’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]
  • EX4400-48F-DC-AFI: [{‘group’: ‘Overview’, ‘attributes’: {‘Full Product Name’: ‘EX4400 Ethernet Switch’, ‘OS Supported’: ‘Junos OS’}}, {‘group’: ‘Chassis’, ‘attributes’: {‘Fixed/Modular Chassis?’: ‘Fixed’, ‘Form Factor’: ‘1 U’, ‘Chassis Height’: ‘1.72 in / 4.3688 cm’, ‘Chassis Width’: ‘17.39 in / 44.1706 cm’, ‘Chassis Depth’: ‘15.71 in / 39.9034 cm’, ‘Chassis Depth (With FRUs)’: ‘17.35 in / 44.069 cm’, ‘Chassis Weight (Spare)’: ‘12.79 lb / 5.8 kg’, ‘Chassis Model Number’: ‘EX4400-48F-S’}}, {‘group’: ‘Chassis Cluster/High Availability/Virtual Chassis’, ‘attributes’: {‘Chassis Cluster/High Availability/Virtual Chassis Port Count’: ‘2’, ‘Chassis Cluster/High Availability/Virtual Chassis Port Type’: ‘QSFP28’, ‘Count of Devices in Virtual Chassis’: ’10’}}, {‘group’: ‘Cooling System’, ‘attributes’: {‘Airflow Direction’: ‘Back-to-front’, ‘AFO/AFI?’: ‘AFI’, ‘Fan Module Model Number’: ‘EX4400-FAN-AFI’, ‘Fan Module Count’: ‘2’, ‘Fan Module Redundancy’: ‘1+1’, ‘Fan Module Hot-Removable And Hot-Insertable?’: ‘Y’}}, {‘group’: ‘Environmental Specifications’, ‘attributes’: {‘Operating Altitude’: ‘6000 ft / 1829 m’, ‘Non-Operating Altitude’: ‘16000 ft / 4877 m’, ‘Operating Temperature’: ’32° through 113° F / 0° through 45° C’, ‘Storage Temperature’: ‘-40° through 158° F / -40° through 70° C’, ‘Relative Humidity, Noncondensing (Operating)’: ‘5% through 90%’, ‘Relative Humidity, Noncondensing (Nonoperating)’: ‘0% through 90%’, ‘Seismic Tolerance’: ‘Zone 4’, ‘Acoustic Noise Level (Max)’: ‘44.61 dB’, ‘Maintenance Clearance’: ’30 in / 76.2 cm’}}, {‘group’: ‘Built-in Network Ports’, ‘attributes’: {‘SFP Port Count’: ’36’, ‘SFP Port – MACsec Support?’: ‘Y’, ‘SFP+ Port Count’: ’12’, ‘SFP+ Port – MACsec Support?’: ‘Y’}}, {‘group’: ‘Other Port Configuration’, ‘attributes’: {‘Console Port Count’: ‘1’, ‘Console Port Type’: ‘RJ-45’, ‘Console Port 2 Count’: ‘1’, ‘Console Port 2 Type’: ‘Type C’, ‘Management Port Count’: ‘1’, ‘Management Port Type’: ‘RJ-45’, ‘USB Port Count’: ‘1’, ‘USB Port Type’: ‘Type A’}}, {‘group’: ‘Performance (Routing/Switching)’, ‘attributes’: {‘Packet Switching Unidirectional (64B)’: ‘456 Gbps’, ‘Packet Switching Bidirectional (64B)’: ‘912 Gbps’, ‘L2/L3 Throughput (64B)’: ‘678 Mpps’, ‘IPv4 Unicast Host Routes (Thousands)’: ’81’, ‘IPv4 Unicast Routes Prefixes (RIB) (Thousands)’: ‘130’, ‘IPv4 Multicast Routes (Thousands)’: ’40’, ‘IPv6 Unicast Host Routes (Thousands)’: ’40’, ‘IPv6 Unicast Routes Prefixes (RIB) (Thousands)’: ’87’, ‘IPv6 Multicast Routes (Thousands)’: ’20’, ‘IPv6 Neighbor Discovery Entries (Thousands)’: ’12’, ‘Egress VLAN ACL’: ‘512’, ‘Egress Port ACL’: ‘1024’, ‘Egress Routed ACL’: ‘1024’, ‘Ingress VLAN ACL’: ‘2048’, ‘Ingress Port ACL’: ‘2048’, ‘Ingress Routed ACL’: ‘2048’, ‘ARP Entries (Thousands)’: ’24’, ‘MSTP Instances’: ’64’, ‘VSTP Instances’: ‘510’, ‘LAGs Count’: ‘128’, ‘Ports Per LAG’: ’16’, ‘MAC Addresses Per System (Thousands)’: ‘112’, ‘Maximum Mirroring Sessions’: ‘4’, ‘Traffic Mirroring Destination VLANs’: ‘1’, ‘Traffic Mirroring Destination Ports’: ‘4’, ‘VLAN IDs Count’: ‘4093’, ‘Jumbo Frame’: ‘9216 bytes’, ‘QoS Hardware Queues Per Port (Multicast)’: ‘4’, ‘QoS Hardware Queues Per Port (Unicast)’: ‘8’}}, {‘group’: ‘Processor’, ‘attributes’: {‘CPU’: ‘2.2 GHz Quad-Core Intel x86 CPU’, ‘DRAM’: ‘4 GB’}}, {‘group’: ‘Power System’, ‘attributes’: {‘PSU Count’: ‘2’, ‘PSU Redundancy’: ‘1+1’, ‘PSU Airflow Direction’: ‘Back-to-front’, ‘DC PSU Model Number’: ‘JPSU-550-C-DC-AFI’, ‘Grounding Cable Lug Type’: ‘LCD8-AF-L, LCD10-AF-L’, ‘Grounding Cable Wire Gauge’: ‘8 AWG / 14 AWG’}}, {‘group’: ‘Routing/Switching Hardware’, ‘attributes’: {‘Uplink/Extension Module Slots’: ‘1’, ‘Uplink/Extension Modules Supported’: ‘EX4400-EM-4S, EX4400-EM-4Y, EX4400-EM-1S’}}, {‘group’: ‘Storage’, ‘attributes’: {‘Internal Storage Size’: ’20 GB’}}]

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects
Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues
Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch
Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

Common Questions

Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?