| Key Specifications |
|---|
| Switching Capacity | 1071/3213Tbps |
| Packet Forwarding Rate (Packet Forwarding Capability) | 345,600Mpps |
| Dimensions(H X W X D)/Mm | 397mm×440m m×660mm 9RU |
| Supervisor Engine Module Slot Count | 2 |
| Power Supply | AC:100V~240V DC:-48V~-60V |
| Service Module Slot Count | 6 |
| Product Specifications |
|---|
| Switching Capacity | 1071/3213Tbps |
| Packet Forwarding Rate (Packet Forwarding Capability) | 345,600Mpps |
| Dimensions(H X W X D)/Mm | 397mm×440m m×660mm 9RU |
| Supervisor Engine Module Slot Count | 2 |
| Power Supply | AC:100V~240V DC:-48V~-60V |
| Service Module Slot Count | 6 |
| Product Specifications |
|---|
| Switching Capacity | 1071/3213Tbps |
| Packet Forwarding Rate (Packet Forwarding Capability) | 345,600Mpps |
| Supervisor Engine Module Slot Count | 2 |
| Service Module Slot Count | 6 |
| Fabric Module Slot Count | 5 (2 supervisor engines integrated) |
| Hardware Architecture | Orthogonal CLOS Architecture |
| Redundancy design | Supervisor, Fabric Module, Power Supply, Fan (front, rear, and left/right airflow) |
| Ethernet Features | Supports 802.1Q, Supports LLDP, Supports Static MAC, Dynamic MAC, Blackhole MAC Configuration, Supports MAC address learning count limitation, Supports Port Mirroring (SPAN/ERSPAN/RSPAN) and Flow Mirroring functionality, Supports Port Aggregation, Supports 802.1d (STP), 802.1w (RSTP), 802.1s (MSTP), Supports Dynamic Link Aggregation, Static Port Aggregation and Cross-board Link Aggregation, Supports MAC/IP subnet/protocol/strategy/Port VLAN |
| Routing Features | Supports Static Routing, RIP, OSPF, IS-IS, BGP4, etc., Supports Equal-cost Routing, Supports Policy Routing, Supports Routing Policies, Supports IPv4 and IPv6 Dual-stack, Supports IPv6 Static Routing, RIPng, OSPFv3, IS-ISv6, BGP4+, Supports DHCPv6 Relay, Supports DHCP Relay Agent, Supports DHCP Snooping, Supports DHCP OPTION 82, Supports DHCP OPTION 43, Supports VRRPv3, Supports Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6, Supports IPv6 Transition Technologies including IPv6 Manual Tunnel, 6to4 Tunnel, ISATAP Tunnel, GRE Tunnel, Supports IPv6 Equal-cost Routing, Supports IPv6 Policy Routing, Supports IPv6 Routing Policies |
| Multicast | Supports PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, Any-RP routing protocols, Supports IGMP V1/V2/V3, IGMP V1/V2/V3 Snooping, Supports PIM6-DM, PIM6-SM, PIM6-SSM, Supports MLD V1/V2, MLD V1/V2 Snooping, Supports Multicast Policies and Multicast QoS, Supports User Rapid Leave Mechanism, Supports Multicast Query |
| Programmability and Automation | Supports Ansible automation technology Supports network automation orchestration through Python/NETCONF/TCL/RESTful API for Dev Ops automated operations and maintenance |
| SDN/ OPENFLOW | Supports OPENFLOW 1.3 standard Supports multiple controllers (EQUAL mode, active/standby mode) Supports multi-table pipeline Supports Group table Supports Meter |
| VXLAN | Supports VXLAN Layer 2 switching Supports VXLAN routing switching Supports VXLAN gateway Supports VXLAN, BGP EVPN features Supports IS-IS+ENDP distributed control plane for VXLAN Supports Open Flow+Netconf centralized control plane for VXLAN Supports establishment of IPv6 VXLAN tunnels for inter-VXLAN IPv4/IPv6 packet communication |
| MPLS/VPLS | Supports L3 MPLS VPN Supports L2 VPN: VLL (Martini, Kompella) Supports MCE Supports MPLS OAM Supports VPLS, VLL Supports hierarchical VPLS, and QinQ+VPLS access Supports P/PE functions Supports LDP protocol |
| Security Mechanisms | EAD security solution support, Portal authentication support, MAC authentication support, IEEE 802.1x and IEEE 802.1x SERVER support, AAA/RADIUS support, HWTACACS support, CLI authentication support, ACL traffic filtering mechanism support, OSPF, RIPv2, and BGPv4 plaintext and MD5 encrypted authentication support, CLI uses hierarchical protection mode to prevent unauthorized user illegal intrusion, different users have different Configuration permissions based on their levels, Telnet login and password mechanism support for restricted IP addresses, IP address, VLAN ID, MAC address, and Port multi-factor binding support, uRPF support, MACsec encryption technology support, master-slave data backup mechanism support, OPS open programmable system support, fault alarm and self-recovery support, data logging support, Configuration firewall, intrusion detection, behavior management, traffic control and other application hardware card support, IP Source Guard support, protection against DoS attacks, ARP attacks, TCP SYN Flood attacks, UDP Flood attacks, broadcast storm attacks, and high-volume attacks support |
| System Management | FTP, TFTP, Xmodem support, SNMP v1/v2c/v3 support, SmartMC support, s Flow traffic statistics support, gRPC, Telemetry Stream traffic visualization function support, RMON support, NTP clock, PTP clock function support, Power Supply intelligent management support, Console port login support, alarm, event, historical log support, online status monitoring mechanism support for detecting key components including Supervisor Engine Module, Fabric Module, chips, and storage, user access authentication, business on-the-go support, unified user management, group domain time-based authorization support, BootROM upgrade and remote online upgrade support, hot patch function support for online patch upgrades, user hierarchical management and password protection support, CLI hierarchical protection support preventing unauthorized user intrusion, IPv6 RA Guard support, CPU hardware queue support for control plane protocol packet hierarchical scheduling and protection, secure boot support |
| Reliability | Independent hardware Fabric Module design achieves true separation of control and forwarding Key switch Router service modules support 1+1 redundancy backup Power Supply supports M+N redundancy backup Fabric Module supports N+M redundancy backup Backplane adopts passive design to avoid single point of failure All components support hot-swapping functionality Supports CPU protection technology Supports real-time hot backup of Configuration data between active and standby Supervisor Engine Module Supports hot-patch functionality for online patching Supports NSR/GR for OSFP/BGP/IS-IS etc. Supports GR for RSVP Supports Port aggregation, supports inter-card link aggregation Supports INQA functionality through direct marking of service packets for real-time traffic detection technology, achieving precise packet loss monitoring and rapid fault localization for IP networks Supports BFD for VRRP/BGP/IS-IS/OSPF/RSVP/Static routing etc., implementing fast fault detection mechanisms for various protocols with fault detection time less than 50ms, Supports BFD/OAM 3ms detection interval Supports Ethernet OAM (802.1ag and 802.3ah) Supports RRPP Supports DLDP Supports VCT Supports Smart-Link Supports ISSU technology for online upgrade of all services |
| Green Energy Saving | Supports 802.3az Energy Efficient Ethernet |
| Environmental requirements | Temperature range: 0°C~45°C Relative humidity: 5%~95% (non-condensing) |
| Power Supply | AC:100V~240V DC:-48V~-60V |
| Dimensions(H X W X D)/Mm | 397mm×440m m×660mm 9RU |
| Catalog Description |
|---|
| Description | H3C S10506X Ethernet Switch Chassis |
| Key Features |
|---|
| Feature 1 | Advanced system architecture adopts advanced CLOS multi-level multi-plane switching architecture, providing continuous bandwidth upgrade capability |
| Feature 2 | Orthogonal Fabric Module design: S10500X Service Module and Fabric Module adopt fully orthogonal design (90 degrees). Business traffic across Line Cards is directly connected to Fabric Module via orthogonal connectors, supporting cell switching, with zero backplane wiring (greatly avoiding signal attenuation), significantly enhancing system bandwidth and scalability. System capacity can be smoothly extended to hundreds of Tbps |
| Feature 3 | Supports 40GE and 100GE Ethernet standards, fully meeting the application and future development needs of non-blocking campus networks |
| Feature 4 | Independent Fabric Module cards, control engine and Fabric Module hardware are mutually independent, adopting 5 switching plane design, and supporting Fabric Module N+M redundancy, greatly improving device reliability, while providing guarantee for subsequent product bandwidth continuous upgrade |
| Feature 5 | Supervisor Engine Module adopts full-width slot, Fan frame and Power Supply frame adopt redundant design, can cope with sudden situations, significantly improving device overall reliability |
| Ordering Information |
|---|
| SFP Gigabit port | |
| 02312173 | SFP-GE-LH80-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP Gigabit port |
| 0231A563 | SFP-GE-LX-SM1310-A; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP Gigabit port |
| 0231A962 | SFP-GE-LX-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP Gigabit port |
| 02312170 | SFP-GE-LH40-SM1310; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP Gigabit port |
| 0231A963 | SFP-GE-LH40-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP Gigabit port |
| 02312172 | SFP-GE-LH40-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 40km, LC); Type: SFP Gigabit port |
| 0231A964 | SFP-GE-LH80-SM1550-D; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP Gigabit port |
| 0231A562 | SFP-GE-SX-MM850-A; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP Gigabit port |
| 0231A961 | SFP-GE-SX-MM850-D; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP Gigabit port |
| 0231A11U | SFP-GE-LX-SM1310-BIDI; Optical transceiver - SFP Gigabit BIDI module-TX1310/RX1490, 10km, LC; Type: SFP Gigabit port |
| 0231A11V | SFP-GE-LX-SM1490-BIDI; Optical transceiver - SFP Gigabit BIDI module-TX1490/RX1310, 10km, LC; Type: SFP Gigabit port |
| Supervisor Engine Module | |
| 0231AABQ | LSUM1MPUS06XEC0; Type: Supervisor Engine Module |
| 0231ABAH | LSUM1MPUS06XEB0; Type: Supervisor Engine Module |
| Configuration Options | |
| 3130A1L9 | LIS-WX-1-BE |
| 3130A1LA | LIS-WX-8-BE |
| 3130A1LB | LIS-WX-16-BE |
| 3130A1LC | LIS-WX-32-BE |
| 3130A1LD | LIS-WX-128-BE |
| 3130A1LE | LIS-WX-1024-BE |
| 3130A1QM | LIS-WX-512-BE |
| 3130A2HB | LIS-WX-4-BE |
| 3130A2HC | LIS-WX-64-BE |
| Fabric Module | |
| 0231A7JD | LSUM1FAB06XEC0; Type: Fabric Module |
| 0231ABEK | LSUM1FAB06XEB0; Type: Fabric Module |
| Power Supply Module | |
| 0231A2KX | LSVM3PSRA; Type: Power Supply Modulemodule |
| Wireless Termination Unit | |
| 9801A11T | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| 9801A0TB | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| Wireless Termination Unitwall-mountmodule | |
| 9801A15R | Type: Wireless Termination Unitwall-mountmodule |
| Wireless Termination Unit | |
| 9801A0WA | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| 9801A1BV | EWP-WTU430-EI; Type: Wireless Termination Unit |
| AP Antenna | |
| 9821A012 | Type: AP Antenna |
| cable | |
| 0404A122 | CAB-RF-0.2m-2*MMCX; Type: cable |
| Wireless Termination Unit | |
| 9801A1E8 | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| T300 Unit | |
| 0202A2HC | PINPOINT-T300-PB-UWB-IN; Type: T300 Unit |
| 9801A19A | Type: T300 Unit |
| 9801A19B | Type: T300 Unit |
| 9801A19C | Type: T300 Unit |
| 9801A1FL | Type: T300 Unit |
| 9801A1FM | Type: T300 Unit |
| 9801A20L | IOT-T301-R; Type: T300 Unit |
| 9801A20N | Type: T300 Unit |
| 9801A20P | IOT-T301-Z; Type: T300 Unit |
| 9801A20Q | Type: T300 Unit |
| 9801A26L | IOTGM1T301L4; Type: T300 Unit |
| IoT Accessory | |
| 0202A2HB | PINPOINT-T-B1011; Pinbo UW Bpositioning terminal-T-B1011; Type: Io T Accessory |
| 0202A2HE | PINPOINT-HULSI; Type: Io T Accessory |
| 0202A2MD | PINPOINT-T-H2011; Pinbo personnelsafety helmetpositioning terminal-T-H2011; Type: Io T Accessory |
| 0202A2ME | PINPOINT-KT-1421-ZD; Pinbo explosion-proofpositioning terminal-KT-1421-ZD; Type: Io T Accessory |
| 0202A2MF | PINPOINT-TU-1900; Pinbo tamper-resistantwristbandunlocker-TU-1900; Type: Io T Accessory |
| 0202A2MG | PINPOINT-TC-1500; Pinbo tamper-resistantwristbandcharger-TC-1500; Type: Io T Accessory |
| 0202A2MH | PINPOINT-TC-1311; Pinbo standardwristbandcharger-TC-1311; Type: Io T Accessory |
| 0202A2MJ | PINPOINT-T-W2511-X; Pinbo personnelpositioningtamper-resistantheart-rate monitoringwristband-T-W2511-X; Type: Io T Accessory |
| 0202A2MK | PINPOINT-T-W2511; Pinbo personnelpositioningtamper-resistantwristband-T-W2511; Type: Io T Accessory |
| 0202A2ML | PINPOINT-T-W1311-P; Pinbo personnelpositioningsmart wristband-T-W1311-P; Type: Io T Accessory |
| 0202A2MM | PINPOINT-T-G1010; Pinbo assetpositioning terminal-T-G1010; Type: Io T Accessory |
| 0202A2MN | PINPOINT-T-W1311; Pinbo personnelpositioningwristband-T-W1311; Type: Io T Accessory |
| 0202A2MR | Type: Io T Accessory |
| 0202A2MT | Type: Io T Accessory |
| 0202A2MU | HSJC-MR3837C; Type: Io T Accessory |
| 0202A2MV | Type: Io T Accessory |
| 0202A2MW | HSJC-MR3848; Type: Io T Accessory |
| 0202A2N0 | Type: Io T Accessory |
| 9801A280 | Type: Io T Accessory |
| Wireless Termination Unit | |
| 9801A1G1 | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| AP Mounting Accessory | |
| 2150A0CB | EWPA-CE-4320H; WA4320H-ACN Wall-mount Kit; Type: AP Mounting Accessory |
| 9821A00H | EWPA-CO-IOT-A; Type: AP Mounting Accessory |
| Wireless Termination Unit | |
| 9801A16J | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| 9801A14D | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| 9801A28M | H3C WT1010-QU-10port Wireless Terminator; Type: Wireless Termination Unit |
| 9801A3DD | EWP-WTU630-IOT; Type: Wireless Termination Unit |
| 9801A294 | EWP-WTU630H; Type: Wireless Termination Unit |
| AP Mounting Accessory | |
| 2115A03N | EWPA-TR-WMK-WA5300; wall-mount Mounting Accessory-WA5300; Type: AP Mounting Accessory |
| 9821A06K | EWPA-TR-Indoor-B; Type: AP Mounting Accessory |
| 9821A06M | EWPA-TR-Indoor-D; Type: AP Mounting Accessory |
| Wireless Termination Unit | |
| 9801A2LA | EWP-WTU632H-IOT; Type: Wireless Termination Unit |
| Wireless Terminator | |
| 9801A11V | Type: Wireless Terminator |
| optical transceiver | |
| 0231A085 | SFP-GE-T; SFP GE copper transceiver (100m, RJ45); Type: optical transceiver |
| 0231A0A6 | SFP-XG-SX-MM850-A; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: optical transceiver |
| 0231A0A8 | SFP-XG-LX-SM1310; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: optical transceiver |
| 0231A1RP | SFP-XG-SX-MM850-D; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: optical transceiver |
| Configuration Options | |
| 9801A11W | WirelessAC ModuleV7Fit |
| Wireless Terminator | |
| 9801A0TA | WirelessAC ModuleV7Fit; Type: Wireless Terminator |
| 9801A1LR | EWP-WT1024-Q; Type: Wireless Terminator |
| Power Supply Module | |
| 9801A1G2 | PSR380-24A; Type: Power Supply Modulemodule |
| 9801A1MF | PSR720-24A; Type: Power Supply Modulemodule |
| Configuration Options | |
| 9801A1G5 | EWPTM1XG02 |
| optical transceiver | |
| 0231A2L3 | SFP-XG-LX-SM1310-E; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: optical transceiver |
| 0231A2L4 | SFP-XG-SX-MM850-E; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: optical transceiver |
| Wireless Terminator | |
| 9801A1G3 | EWP-WT1024-X-HI; Type: Wireless Terminator |
| 9801A1LQ | EWP-WT1024-X-Q; Type: Wireless Terminator |
| 9801A1LS | Type: Wireless Terminator |
| Power Adapter | |
| 0231A1SS | EWPAM2NPOE; Type: Power Adapter |
| Antenna | |
| 2701A022 | ANT-2503C-S4; Type: Antenna |
| Configuration Options | |
| 0235A1X2 | WirelessAC ModuleV7Fit |
| Power Adapter | |
| 0231A4QB | ADP040-54V; Type: Power Adapter |
| T300 Unit | |
| 9801A26P | Type: T300 Unit |
| 9801A26R | IOT-T320; Type: T300 Unit |
| 9801A26S | Type: T300 Unit |
| 9801A26U | IOT-T320M; Type: T300 Unit |
| Configuration Options | |
| 9801A1CT | WirelessAC ModuleV7Fit |
| 9801A15K | WirelessAC ModuleV7Fit |
| Power Cord | |
| 04041104 | Cable-Power-AC; Wall Outlet AC Power Cord-3.0m-3*1.0mm^2-black (GB1002plug (3P)straight male250V10A) (227 IEC 53(RVV)) (C13connector (3P)straight female250V10A)-China Standard; Type: Power Cord |
| Configuration Options | |
| 9801A1DV | WirelessAC ModuleV7Fit |
| 9801A263 | EWP-WA2610H-LI-FIT |
| 9801A11S | WirelessAC ModuleV7Fit |
| 9801A0VY | WirelessAC ModuleV7Fit |
| 0235A1PR | WirelessAC ModuleV7Fit |
| 9801A0UG | EWP-WA4320-ACN-C-FIT |
| 9801A11H | EWP-WA4320-ACN-D-FIT |
| 9801A0X7 | EWP-WA4320-ACN-E-FIT |
| 9801A0T7 | EWP-WA4320-ACN-SI-FIT |
| 9801A1TE | WirelessAC ModuleV7Fit |
| 9801A0X9 | WirelessAC ModuleV7Fit |
| 9801A0UE | WirelessAC ModuleV7Fit |
| 9801A0YG | WirelessAC ModuleV7Fit |
| 9801A1HL | WirelessAC ModuleV7Fit |
| Power Adapter | |
| 9802A00Q | ADP12-12A; Power Adapter-12W-12V-1A-1.5M; Type: Power Adapter |
| Configuration Options | |
| 9801A1SN | EWPAM1WPD528 |
| Antenna | |
| 2701A01M | ANT-2503CM; Type: Antenna |
| 2701A01T | ANT-2503C-S; Type: Antenna |
| Configuration Options | |
| 0404A0FS | CAB-RF-5m-2*SMA |
| 0404A0FT | CAB-RF-10m-2*SMA |
| 0404A0HV | CAB-RF-RG8-5m |
| 0404A0HW | CAB-RF-RG8-10m |
| 0404A126 | CAB-RF-20m-2*RSMAF |
| Load | |
| 2711A000 | PSMA-50KR; Load-DC~12.4G Hz-50ohm-<=1.25-1W-RSMA Female; Type: Load |
| Configuration Options | |
| 0235A1PQ | EWP-WA4320i-X-R-FIT |
| 0235A1GS | WirelessAC ModuleV7Fit |
| Power Adapter | |
| 0213A03K | FSP025-1AD207A; Type: Power Adapter |
| AP Mounting Accessory | |
| 2115A03Q | EWPA-TR-EWMK; Adjustable wall-mount Mounting Accessory; Type: AP Mounting Accessory |
| Configuration Options | |
| 0404A06Q | CAB-AC Pwr CHI-1.8m; Wall Outlet AC Power Cord-1.8m-3*0.75mm^2-black (GB1002plug (3P)straight male250V10A) (227 IEC 53(RVV)) (C13connector (3P)straight female250V10A)-China Standard |
| 9801A0YD | WirelessAC ModuleV7Fit |
| 9801A18Q | EWP-WA5320-C-FIT |
| 9801A18R | EWP-WA5320-C-EI-FIT |
| 9801A1YG | EWP-WA5320-C-IOT-FIT |
| 9801A1WB | EWP-WA5320-D-FIT |
| 9801A1B3 | EWP-WA5320-SI-FIT |
| 9801A1E4 | EWP-WA5320-TI-FIT |
| Antenna | |
| 2701A00M | C5060-510002-A; Type: Antenna |
| 2701A023 | ANT-5014P-M2; Type: Antenna |
| CAB-RF-1.2m (N50SM+RSMA50SF) | |
| 0404A0FL | CAB-RF-1.2m (N50SM+RSMA50SF) |
| Configuration Options | |
| 9801A0YE | WirelessAC ModuleV7Fit |
| 9801A0YC | WirelessAC ModuleV7Fit |
| 9801A25D | WirelessAC ModuleV7Fit |
| 9801A20W | WirelessAC ModuleV7Fit |
| 9801A262 | EWP-WA5320H-LI-FIT |
| 9801A2LB | EWP-WA5320S-E-FIT |
| AP Mounting Accessory | |
| 9821A00N | EWPA-WP-RJ45-5630X; Type: AP Mounting Accessory |
| Power Adapter | |
| 0202A1DE | PT-PSE107GRO-S; Type: Power Adapter |
| 9802A00D | EWPAM1UPOE2; Type: Power Adapter |
| optical transceiver | |
| 0231A0BY | SFP-GE-LX10-SM1310; SFP GE optical transceiver (-40°C~85°C, 1310nm, 10km, LX, SM, LC); Type: optical transceiver |
| T300 Unit | |
| 0202A2HD | PINPOINT-T300-PB-UWB-OUT; Type: T300 Unit |
| 9801A1H2 | Type: T300 Unit |
| 9801A1H4 | Type: T300 Unit |
| 9801A26N | IOT-T320MX; Type: T300 Unit |
| 9801A26V | IOT-T320X; Type: T300 Unit |
| Configuration Options | |
| 9801A17D | WirelessAC ModuleV7Fit |
| Antenna Feeder Lightning Protector | |
| 1902A002 | MHT6000-N-1; Antenna Feeder Lightning Protector-10KA-20V-2.4~6.0G Hz-100W-N-F/N-M; Type: Antenna Feeder Lightning Protector |
| Antenna | |
| 2701A01K | ANT-2506V-M4-E; Type: Antenna |
| 2701A01U | ANT-2513P-M2; Type: Antenna |
| 2701A01Y | ANT-5018P-M2; Type: Antenna |
| 2701A020 | ANT-2515P-M4; Type: Antenna |
| 2701A02K | ANT-2547V; Type: Antenna |
| CAB-RF-4.5m (2*NSM+RG8/U) | |
| 0404A08W | CAB-RF-4.5m (2*NSM+RG8/U) |
| CAB-RF-10m (2*NSM+RG8/U) | |
| 0404A08X | CAB-RF-10m (2*NSM+RG8/U) |
| CAB-RF-0.4m (NSM+RG402+NSM) | |
| 0404A0CD | CAB-RF-0.4m (NSM+RG402+NSM) |
| Configuration Options | |
| 0404A0FM | CAB-RF-1.2m-2*N50SM |
| 14040288 | BNC-RF-N-50-KK |
| 9801A1CS | WirelessAC ModuleV7Fit |
| 1413A002 | OP-DLC-10m-S |
| 9801A1YH | EWP-WA5320X-E-ANT-FIT |
| 9801A260 | EWP-WA5320X-LI-FIT |
| 9801A1CR | WirelessAC ModuleV7Fit |
| 9801A2FE | EWP-WA5320XS-LI-FIT |
| 9801A1BX | WirelessAC ModuleV7Fit |
| 9801A265 | EWP-WA5320i-LI-FIT |
| 9801A266 | WirelessAC ModuleV7Fit |
| 9801A1R8 | WirelessAC ModuleV7Fit |
| Antenna | |
| 2701A02G | ANT-5014P-Q4; Type: Antenna |
| Configuration Options | |
| 9801A1E7 | WirelessAC ModuleV7Fit |
| 9801A0YF | WirelessAC ModuleV7Fit |
| 9801A1YF | EWP-WA5530-LI-FIT |
| 9801A1BW | EWP-WA5530-SI-FIT |
| 9801A261 | EWP-WA5530S-FIT |
| 9801A1TF | WirelessAC ModuleV7Fit |
| Power Adapter | |
| 0213A05R | ADP040-54; Type: Power Adapter |
| Configuration Options | |
| 9801A0YH | WirelessAC ModuleV7Fit |
| Antenna | |
| 2701A02H | ANT-5014P-M4; Type: Antenna |
| Configuration Options | |
| 0404A1NK | CAB-RF-4.5m-W36D |
| 0404A1NL | CAB-RF-4.5m-W36B |
| 0404A1NM | CAB-RF-10m-W36C |
| 0404A1NN | CAB-RF-10m-W36E |
| AP Mounting Accessory | |
| 9821A00Q | EWPA-IM-Power Connector-WA5620E; Type: >AP Mounting Accessory |
| Configuration Options | |
| 9801A19E | EWP-WA5620E-T-FIT |
| Passive Splitter | |
| 2702A003 | GFQ-2B-2458G; Type: Passive Splitter |
| Configuration Options | |
| 9801A1E6 | EWP-WA5620X-FIT |
| 0235A1SV | WirelessAC ModuleV7Fit |
| 9801A17C | EWP-WA5630X-FIT |
| 9801A2BS | EWP-WA6320-C-FIT |
| 9801A2BT | EWP-WA6320-D-FIT |
| 9801A3G1 | EWP-WA6320-HI-FIT |
| 9801A42A | EWP-WA6320-SI-H20-FIT |
| 9801A297 | WirelessAC ModuleV7Fit |
| Fiber Attenuator | |
| 45030021 | AT-1315-5-LC; Type: Fiber Attenuator |
| 45030022 | AT-1315-10-LC; Type: Fiber Attenuator |
| Configuration Options | |
| 9801A2BU | EWP-WA6320H-LI-FIT |
| 9801A3DA | EWP-WA6320S-C-FIT |
| 9801A34A | EWP-WA6320S-E-FIT |
| 9801A23U | EWP-WA6322-FIT |
| 9801A2RK | WirelessAC ModuleV7Fit |
| AP Mounting Accessory | |
| 9821A06L | EWPA-TR-Indoor-C; Type: AP Mounting Accessory |
| Configuration Options | |
| 9801A2FC | WirelessAC ModuleV7Fit |
| 9801A2QQ | EWP-WA6322H-HI-FIT |
| 9801A2PX | EWP-WA6322H-LI-FIT |
| 9801A23V | EWP-WA6330-FIT |
| 9801A2BV | EWP-WA6330-LI-FIT |
| AP Mounting Accessory | |
| 9821A06P | EWPA-TR-Indoor-A; Type: AP Mounting Accessory |
| Configuration Options | |
| 9801A2DQ | EWP-WA6338-FIT |
| 9801A2QR | EWP-WA6338-HI-FIT |
| 9801A2PY | EWP-WA6338-LI-FIT |
| Antenna | |
| 2701A02L | ANT-2510P-M4; Type: Antenna |
| optical transceiver | |
| 0231A1RQ | SFP-XG-LX-SM1310-D; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: optical transceiver |
| 0231A9X2 | SFP-XG-CPRI-IR-SM1310; SFP+ 10GbE CPRI optical transceiver (-40°C to 85°C, 1310nm, 1.4km, LC); Type: optical transceiver |
| 0231A9X3 | SFP-XG-CPRI-LR-SM1310; SFP+ 10GbE CPRI optical transceiver (-40°C to 85°C, 1310nm, 10km, LC); Type: optical transceiver |
| Auxiliary Material | |
| 04041307 | CAB-PGND-Pwr-3m; Type: Auxiliary Material |
| Configuration Options | |
| 9801A3HM | EWP-WA6510E-T |
| Power Adapter | |
| 9802A01P | PWR-RD1201500-C55-81GB; Type: Power Adapter |
| AP Mounting Accessory | |
| 9821A08J | EWPA-IM-DC Phoenix Connector; Type: AP Mounting Accessory |
| Configuration Options | |
| 9801A3HK | EWP-WA6520H-EGPON-FIT |
| Power Adapter | |
| 9802A01Q | PWR-S36B51-540A067-C4; Type: Power Adapter |
| Accessory | |
| 1408A048 | CON-2P-U4; Type: Accessory |
| optical transceiver | |
| 0231AJXK | SFP-2.5G-LX10-SM1310-DR-I; SFP 2.5G/1G single-modeindustrial temperatureoptical transceiver (1310nm, 10km, LC); Type: optical transceiver |
| Configuration Options | |
| 9801A3L6 | EWP-WA6522-FIT |
| 9801A3L7 | EWP-WA6522H-HI-FIT |
| 9801A2VC | EWP-WA6526-FIT |
| Antenna | |
| 9827A005 | ANT-2507P-S4; Type: Antenna |
| CAB-RF-6.1m (N+RG8+SMA) | |
| 0404A090 | CAB-RF-6.1m (N+RG8+SMA) |
| Configuration Options | |
| 9801A2VD | EWP-WA6526E-FIT |
| 9801A2Q8 | EWP-WA6526H-FIT |
| 9801A1LH | EWP-WA6528-FIT |
| Power Adapter | |
| 0202A7DF | PT-PSE117GRO-S; Type: Power Adapter |
| AP Mounting Accessory | |
| 9821A04F | EWPA-WP-M25*1.5; Type: AP Mounting Accessory |
| 9821A06Q | EWPA-TR-Outdoor-B; Type: AP Mounting Accessory |
| Configuration Options | |
| 9804A027 | H3C GC-FPLC6U1V01 |
| 9804A03A | H3C GC-FPLC6U1V02 |
| optical transceiver | |
| 0231AKNR | SFP-GE-POE; Type: optical transceiver |
| 0231AKNS | SFP-XG-POE-MR; Type: optical transceiver |
| Configuration Options | |
| 9801A3GR | EWP-WA6528X-E-FIT |
| 9801A2RE | EWP-WA6528i-FIT |
| 9801A2VY | EWP-WA6530-FIT |
| 9801A2VX | EWP-WA6530-LI-FIT |
| AP Mounting Accessory | |
| 9821A0NL | EWPA-IM-Phoenix ToTerminals; Type: AP Mounting Accessory |
| Configuration Options | |
| 9801A3L8 | EWP-WA6530i-FIT |
| 9801A2BQ | WirelessAC ModuleV7Fit |
| Load | |
| 27110001 | N-50JR; Load-0~6G Hz-50ohm-<1.25-2W-N Male; Type: Load |
| AP Mounting Accessory | |
| 9821A0Q7 | Type: AP Mounting Accessory |
| Configuration Options | |
| 9801A2F5 | EWP-WA6620X-FIT |
| 9801A2XD | EWP-WA6620X-LI-FIT |
| 9801A2XE | EWP-WA6620XE-LI-FIT |
| 9801A24H | EWP-WA6622-FIT |
| 9801A2ES | EWP-WA6628E-T |
| 9801A2ER | EWP-WA6628X-FIT |
| 9801A2U9 | EWP-WA6628XM-FIT |
| 9801A24G | EWP-WA6630X-FIT |
| 9801A2K2 | EWP-WA6636-FIT |
| 9801A24F | EWP-WA6638-FIT |
| 9801A2ET | EWP-WA6638i-FIT |
| 8814A084 | SV-PS-RTE-F |
| 8814A085 | SV-PS-RTE-C |
| IoT Service | |
| 0504A1AF | PINPOINT-ABELL-SV901; Type: Io T Service |
| 0504A1AG | PINPOINT-Engine-SV901; Type: Io T Service |
| Wireless Service Module | |
| 0231A5AS | S10500X switch Series; Type: Wireless Service Module |
| 0231ABFB | Type: Wireless Service Module |
| Configuration Options | |
| 0231A4NQ | LSUM1FWDEC0 |
| 0231A4NR | S10500X switch Series |
| 0231ACXE | S10500X switch Series |
| SFP Gigabit port | |
| 0231A12T | SFP-FE-LX-SM1310-BIDI; SFP Fast EthernetBID Ioptical transceiver (TX1310/RX1550nm, 15km, LC); Type: SFP Gigabit port |
| 0231A12U | SFP-FE-LX-SM1550-BIDI; SFP Fast EthernetBID Ioptical transceiver (TX1550/RX1310nm, 15km, LC); Type: SFP Gigabit port |
| 0231A564 | SFP-FE-LX-SM1310-A; Optical transceiver - SFP 100M/155M single-mode module (1310nm, 15km, LC); Type: SFP Gigabit port |
| 0231A965 | SFP-FE-LX-SM1310-D; Optical transceiver - SFP 100M/155M single-mode module (1310nm, 15km, LC); Type: SFP Gigabit port |
| 0231A320 | SFP-FE-SX-MM1310-A; Optical transceiver - SFP 100M/155M multimode module (1310nm, 2km, LC); Type: SFP Gigabit port |
| 0231A960 | SFP-GE-T-D; SFP GE copper transceiver (100m, RJ45); Type: SFP Gigabit port |
| SFP+ 10GbE port | |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1270nm/RX1330nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1270nm/RX1330nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1330nm/RX1270nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1330nm/RX1270nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1490nm/RX1550nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1550nm/RX1490nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231A0SP | SFP-XG-LH40-SM1550; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A1RR | SFP-XG-LH40-SM1550-D; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A1PA | SFP-XG-LH80-SM1550; SFP+ 10GbE optical transceiver (1550nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231A2T6 | SFP-XG-LH80-SM1550-D; SFP+ 10GbE optical transceiver (1550nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231A0AK | LSWM1STK; SFP+ cable0.65m; Type: SFP+ 10GbE port |
| 0231A0AL | LSWM2STK; SFP+ cable1.2m; Type: SFP+ 10GbE port |
| 0231A0AM | LSWM3STK; SFP+ cable3m; Type: SFP+ 10GbE port |
| Configuration Options | |
| 0231A4EW | LSUM2GP24TSSA0 |
| 0231A4EY | S10500X switch Series |
| 0231A4EX | S10500X switch Series |
| SFP Gigabit port | |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI; SFP Gigabit BIDI optical transceiver (TX1310/RX1550nm, 40km, LC); Type: SFP Gigabit port |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI; SFP Gigabit BIDI optical transceiver (TX1550/RX1310nm, 40km, LC); Type: SFP Gigabit port |
| Configuration Options | |
| 0231A2XT | LSUM2GP24TSSE0 |
| 0231A2XU | LSUM2GT24PTSSE0 |
| 0231A2XV | LSUM2GT24TSSE0 |
| 0231A2XS | LSUM2GP44TSSE0 |
| 0231A2Y5 | LSUM2GT48SE0 |
| 0231A2VB | S10500X switch Series |
| QSFP+ port | |
| 0231A3U4 | QSFP-40G-D-AOC-10M; 40G QSFP+ to 40G QSFP+10m AOC; Type: QSFP+ port |
| 0231A3U5 | QSFP-40G-D-AOC-20M; 40G QSFP+ to 40G QSFP+20m AOC; Type: QSFP+ port |
| 0231A3U3 | QSFP-40G-D-AOC-7M; 40G QSFP+ to 40G QSFP+7m AOC; Type: QSFP+ port |
| 0231A2E4 | QSFP-40G-LR4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 10km, LR4, LC); Type: QSFP+ port |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850; QSFP+ 40G BIDI optical transceiver (850nm, 100m, SR); Type: QSFP+ port |
| 0231A4PB | QSFP-40G-LR4L-WDM1300; QSFP+ 40G optical transceiver (1310nm, 2km, LR4L, LC); Type: QSFP+ port |
| 0231A4UG | QSFP-40G-ER4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 40km, ER4, LC); Type: QSFP+ port |
| 0231A2NF | QSFP-40G-SR4-MM850; Type: QSFP+ port |
| 0231A2KL | QSFP-40G-CSR4-MM850; Type: QSFP+ port |
| Configuration Options | |
| 0231A2VC | S10500X switch Series |
| QSFP28 port | |
| 0231A4B3 | QSFP-100G-D-AOC-10M; 100G QSFP28 to 100G QSFP28 10m AOC; Type: QSFP28 port |
| 0231A4AY | QSFP-100G-D-CAB-1M; Type: QSFP28 port |
| 0231A4B4 | QSFP-100G-D-AOC-20M; 100G QSFP28 to 100G QSFP28 20m AOC; Type: QSFP28 port |
| 0231A4B0 | QSFP-100G-D-CAB-3M; Type: QSFP28 port |
| 0231A4B2 | QSFP-100G-D-AOC-7M; 100G QSFP28 to 100G QSFP28 7m AOC; Type: QSFP28 port |
| 0231A4B1 | QSFP-100G-SR4-MM850; 100G QSFP28 optical transceiver (850nm, 100m OM4, SR4, MPO); Type: QSFP28 port |
| 0231A5H6 | 100G QSFP28 optical transceiver (850nm, 100m OM4, SWDM4, LC); Type: QSFP28 port |
| 0231A5UL | QSFP-100G-eSR4-MM850; 100G QSFP28 optical transceiver (850nm, 300m OM4, eSR4, MPO); Type: QSFP28 port |
| 0231A5HA | QSFP-100G-PSM4-SM1310; 100G QSFP28 optical transceiver (1310nm, 500m, PSM4, MPO/APC); Type: QSFP28 port |
| 0231A5LL | QSFP-100G-LR4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 2km, LR4L, CWDM4, LC); Type: QSFP28 port |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 40km, ER4L, WDM, LC); Type: QSFP28 port |
| 0231A1LS | LSWM1QSTK0; 40G QSFP+ 1m cable; Type: QSFP28 port |
| 0231A1LT | LSWM1QSTK1; 40G QSFP+ 3m cable; Type: QSFP28 port |
| 0231A1LU | LSWM1QSTK2; 40G QSFP+ 5m cable; Type: QSFP28 port |
| Configuration Options | |
| 0231A4W8 | S10500X switch Series |
| QSFP28 port | |
| 0231A4UF | QSFP-100G-LR4-WDM1300; 100G QSFP28 optical transceiver (1310nm, 10km, LR4, WDM, LC); Type: QSFP28 port |
| 0231A1LV | LSWM1QSTK3; 40G QSFP+ to 4x10G SFP+ 1m cable; Type: QSFP28 port |
| 0231A1LW | LSWM1QSTK4; 40G QSFP+ to 4x10G SFP+ 3m cable; Type: QSFP28 port |
| 0231A1LX | LSWM1QSTK5; 40G QSFP+ to 4x10G SFP+ 5m cable; Type: QSFP28 port |
| Configuration Options | |
| 0231A5K4 | S10500X switch Series |
| 0231A4FB | LSUM2QGS12SG0 |
| QSFP+ port | |
| 0231AJHT | QSFP-40G-LX4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 150m, OM3, LX4); Type: QSFP+ port |
| 0231A2UQ | QSFP-40G-LR4-PSM1310; Type: QSFP+ port |
| Configuration Options | |
| 0231A5S2 | LSUM2QGS24RSG0 |
| SFP+ 10GbE port | |
| 0231A0G1 | LSTM1STK; SFP+ cable5m; Type: SFP+ 10GbE port |
| Configuration Options | |
| 0231A4NM | LSUM2TGS32QSSG0; S10500X switch Series |
| 0231A4F8 | LSUM2TGS48SG0 |
| 0231A5W2 | S10500X switch Series |
| 0231ANL7 | LSUM1TGS24CSSH0 |
| SFP28 port | |
| 0231A6NG | SFP-25G-D-AOC-10M; Type: SFP28 port |
| 0231A5GY | SFP-25G-D-CAB-1M; Type: SFP28 port |
| 0231A6NH | SFP-25G-D-AOC-20M; Type: SFP28 port |
| 0231A5H0 | SFP-25G-D-CAB-3M; Type: SFP28 port |
| 0231A6ND | SFP-25G-D-AOC-3M; Type: SFP28 port |
| 0231A5H1 | SFP-25G-D-CAB-5M; Type: SFP28 port |
| 0231A6NE | SFP-25G-D-AOC-5M; Type: SFP28 port |
| 0231A6NF | SFP-25G-D-AOC-7M; Type: SFP28 port |
| 0231ABR6 | SFP-25G-LR-SM1310; 25G SFP28 optical transceiver (1310nm, 10km, LR, SM, LC); Type: SFP28 port |
| 0231A4Y2 | SFP-25G-SR-MM850; 25G SFP28 optical transceiver (850nm, 100m, SR, MM, LC); Type: SFP28 port |
| Configuration Options | |
| 0231A7W8 | LSUM1YGS24CSSH0 |
| 0231A8EP | S10500X switch Series |
| SFP+ 10GbE port | |
| 0231AH0W | SFP-10GE-T; SFP+ 10G Ecopper transceiver (Cat6a/Cat7, 30m, RJ45); Type: SFP+ 10GbE port |
| Configuration Options | |
| 0231ABR7 | LSUM1TGS48RSH0 |
| 0231AGA2 | LSUM2TGS48SH0 |
| QSFP28 port | |
| 0231A5HC | QSFP-100G-4SFP-25G-CAB-1M; Type: QSFP28 port |
| 0231A5HD | QSFP-100G-4SFP-25G-CAB-3M; Type: QSFP28 port |
| Configuration Options | |
| 0231A8FJ | LSUM1CGS8QSSH0 |
| 0231A8FE | LSUM1CGS8SH0 |
| 0231A8E8 | S10500X switch Series |
| QSFP28 port | |
| 0231A5HE | QSFP-100G-4SFP-25G-CAB-5M; Type: QSFP28 port |
| 0231AFJA | QSFP-100G-ZR4-WDM1300; 100G QSFP28 optical transceiver (1300nm, 80km, ZR4, WDM, LC); Type: QSFP28 port |
| Configuration Options | |
| 0231AABN | LSUM1CGS32XSH0 |
| SFP28 port | |
| 0231AFVF | SFP-25G-CSR-MM850; 25G SFP28 optical transceiver (850nm, 300m OM3, CSR, MM, LC); Type: SFP28 port |
| Configuration Options | |
| 0231A9UE | LSUM1YGS48XSH0 |
| 0231A8UN | LSUM1TGT24FD0 |
| SFP+ 10GbE port | |
| 0231A1J8 | LSTM2STK; SFP+ cable7m; Type: SFP+ 10GbE port |
| Configuration Options | |
| 0231A5PJ | LSUM1TGS16FD0 |
| 0231A5PB | LSUM1TGS24FD0 |
| 0231A5ST | LSUM1GP40TS8FD0 |
| SFP Gigabit port | |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI; SFP Gigabit BIDI optical transceiver (TX1490/RX1550nm, 70km, LC); Type: SFP Gigabit port |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI; SFP Gigabit BIDI optical transceiver (TX1550/RX1490nm, 70km, LC); Type: SFP Gigabit port |
| Configuration Options | |
| 0231AC4Y | LSUM2GP40TS8FD0 |
| 0231A5SH | LSUM1GP48FD0 |
| 0231A5SN | LSUM1GT48FD0 |
| 0231A5PP | S10500X switch Series |
| 3130A1G5 | LIS-S10500-VD |
| 3130A1G6 | LIS-S10500-DC |
| Power Supply Module | |
| 0231A2LC | LSUM1AC1200; AC Power Supply Module, 1200W; Type: Power Supply Modulemodule |
| 0231A0PP | LSUM1AC2500; AC Power Supply Module, 2500W; Type: Power Supply Modulemodule |
| 0231A0PR | LSUM1DC2400; DC Power Supply Module, 2400W; Type: Power Supply Modulemodule |
| Power Cord | |
| 0404A0E2 | CAB-DC Pwr-15m-2; Type: Power Cord |
| 0404A0E1 | CAB-DC Pwr-3m-2; Type: Power Cord |
| Configuration Options | |
| 0231A8FK | FAN-120-6-A |
| 0231A7PT | FAN-120-2-A |
| Rail Kit | |
| 0231A0HP | LSTM1KSGD0; Type: Rail Kit |
| 0231A0PL | LSTM2KSGD0; Type: Rail Kit |
| 0231A4EK | LSXM1BSR; 1U Adjustable Rack Rail-630mm~900mm; Type: Rail Kit |
| Serial Cable | |
| 04042967 | CAB-CON-1.8m; Type: Serial Cable |
| 0404A1EE | CAB-Console-1.8m-W31R; Console Cable-1.8m (RJ45P) (UL2725(3C28AWG)) (USB AP); Type: Serial Cable |
| Base Configuration | |
| 0235A3LG | LS-10506X; H3C S10506X Ethernet Switch Chassis |
| Product Identity |
|---|
| Brand | H3C |
| Series | H3C S10500X Series Switches |