H3C LS-12501X-AF Ethernet Switch is H3C S12501X-AF Ethernet Switch Host.

H3C LS-12501X-AF Ethernet Switch
H3C LS-12501X-AF Ethernet Switch. H3C S12501X-AF Ethernet Switch Host.
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Key Specifications | |
|---|---|
| MPU console port | 1 / 1 / 1 |
| max ND table size for IPv6 | 48K / 48K |
| MPU slots | 2 / 2 / 2 |
| Maximum power consumption | 4800 W / 9600 W / 19200W |
| Throughput | 28800Mpps / 57600Mpps / 115200Mpps |
| LPU slots | 4 / 8 / 16 |
| Product Specifications | |
| Switching capacity | 57.6T/387Tbps / 115.2T/516Tbps / 230.4T/1032Tbps |
| Throughput | 28800Mpps / 57600Mpps / 115200Mpps |
| MPU slots | 2 / 2 / 2 |
| LPU slots | 4 / 8 / 16 |
| Maximum power consumption | 4800 W / 9600 W / 19200W |
| Weight (full configuration) | ≤ 100 kg≤ 220.5 lb / ≤ 190 kg≤ 418.9 lb / ≤ 350 kg≤ 771.6 lb |
| Dimensions (H x W x D) | 264 x 440 x 857 mm (6U)10.4 x 17.3 x 33.7 in / 531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in / 931 x 440 x 857 mm (21U)36.7 x 17.3 x 33.7 in |
| Switching fabric module slots | 6 / 6 / 6 |
| MPU name | LSXM1SUP04B1 / LSXM1SUP04H1 / LSXM1SUPB1 / LSXM1SUPH1 / LSXM1SUPB1 / LSXM1SUPH1 |
| MPU processor | Quad Core 1.2 GHz / Quad Core 1.2 GHz / Quad Core 1.2 GHz |
| MPU SDRAM | 8 GB / 16 GB / 8 GB / 16 GB / 8 GB / 16 GB |
| MPU flash | 1 GB / 1 GB / 1 GB |
| MPU console port | 1 / 1 / 1 |
| MPU MGMT ports | 2x 10/100/1000M Base-T2x 1000M SFP / 2x 10/100/1000M Base-T2x 1000M SFP / 1x 10/100/1000M Base-T1x 1000M SFP / 2x 10/100/1000M Base-T2x 1000M SFP / 1x 10/100/1000M Base-T1x 1000M SFP |
| MPU USB port | 1 / 1 / 1 |
| Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays |
| Product Specifications | |
| Device virtualization | IRF |
| Network virtualization | BGP-EVPNVxLAN |
| VXLAN | L2 VxLAN gatewayL3 VxLAN gatewayDistributed VxLAN gatewayCentralized VxLAN gatewayEVPN VxLANmanual configured VxLANIPv4 VxLAN tunnel |
| Programmability | Openflow1.3NetconfAnsiblePython / TCL/Restful API to realize DevOps automated operation and maintenance |
| Traffic analysis | Sflow |
| VLAN | Port-based VLANsVLAN mappingL2PTMVRP(Multiple VLAN Registration Protocol) |
| MAC address | Dynamic learning and aging of mac address entriesDynamic,static and blackhole entries |
| IPv4 routing (Hardware-based unicast routing) | RIP(Routing Information Protocol) v1/2OSPF (Open Shortest Path First) v1/v2ISIS(Intermediate System to Intermediate system)BGP (Border Gateway Protocol)Routing policyVRRPPBRICMP |
| IPv6 routing (Hardware-based unicast routing) | RIPngOSPFv3IPv6 ISISBGP4+Routing policyVRRPPBRIPv6 ICMP |
| IP Service | DHCP Server, DHCP Relay, DHCP SnoopingDHCP server of 3K operations/second |
| MPLS/VPLS | Support L3 MPLS VPNSupport MCEVPLSSupport MPLS OAMSupport P/PE functionSupport LDP protocol |
| Multicast (Hardware-based multicast routing) | IGMP snoopingMLD snoopingIPv4 and IPv6 multicast VLANIPv4 and IPv6 PIM snoopingIGMP and MLDPIM and IPv6 PIM, Any-RPMSDP |
| Telemetry | ERSPANPacket capture |
| QOS | Weighted Random Early Detection (WRED) and tail dropFlexible queue scheduling algorithms based on port and queue, including strict priority (SP), Weighted Deficit Round Robin (WDRR), Weighted Fair Queuing (WFQ), SP + WDRR, and SP + WFQ. Traffic shapingCOPP |
| Configuration and maintenance | Console telnet and SSH terminalsSNMPv1/v2/v3ZTP |
| Configuration and maintenance | System logFile upload and download via FTP/TFTPBootRom update and remote updateNQAping,tracert NTP |
| Security and management | Hierarchical management and password protection of usersAuthentication methods,including AAA,RADIUS and HWTACACSSupport DDos, ARP attack and ICMP attack functionSSH 2.0HTTPSSSLPKIBoot ROM access control (password recovery)RMONpermit third party transceivers (license) |
| HA | Independent switching fabric modules1+1 redundancy or key components such as MPUs and power modulesN+1 redundancy for switching fabric modulesPassive backplaneCLOS+ midplane free design (12500X-AF)Hot swapping for all componentsReal-time data backup on active/standby MPUs |
| HA | Hot patchingNSR/GR for OSFP/BGP/IS-IS/RSVP Port aggregation and multi-card link aggregationBFD for VRRP/BGP/IS-IS/OSPF/RSVP/static routing, with a failover time less than 50 millisecondsIP FRR and TE FRR with a switchover time less than 50 millisecond |
| IEEE standard | 802.3ab/802.3ae/802.3z/802.3x/802.3ad802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG802.1x/802.1Qbb/802.1az/802.1Qaz |
| RFC | RFC793/RFC2328/RFC1256/RFC1771/RFC1185/RFC1191/RFC1195/RFC1195/RFC1212/RFC1213/RFC1213/RFC1213/RFC1215/RFC1245/RFC1246/RFC1256/RFC1256/RFC1265/RFC1266/RFC1268/RFC1271/RFC1284/RFC1286/RFC1305/RFC1305/RFC1305/RFC1321/RFC1323 |
| EMC | FCC Part 15 (CFR 47) CLASS AICES-003 CLASS AVCCI CISPR 32 CLASS ACISPR 22 CLASS AEN 55022 CLASS AAS/NZS CISPR22 CLASS ACISPR 32 CLASS AEN 55032 CLASS AAS/NZS CISPR32 CLASS ACISPR 24EN 55024EN 61000-3-2EN 61000-3-3ETSI EN 300 386 |
| Temperature | Operating temperature: 0°C to 40°C (32°F to 104°F)Storage temperature: -40°C to 70°C (-40°F to 158°F) |
| Humidity | 5% to 95% (non-condensing) |
| Environmental protection | WEEE and RoHS |
| Safety | UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter J GB 4943.1 |
| Product Specifications | |
| Virtualization | IRF2.0 stack / 2 / 2 |
| M-LAG device number | 2 / 2 |
| ACL | max number of ingress ACLs / 40K / 40K |
| max number of ingress Car | 8K / 8K |
| max number of ingress Counter | 8K / 8K |
| max number of egress ACLs | 20K / 20K |
| max number of egress Counter | 4K / 4K |
| Forwarding table | Jumbo frame length(byte) / 12288 / 12288 |
| Mirroring group | 15 / 15 |
| PBR policy | 1000 / 1000 |
| PBR node | 256 / 256 |
| max number of MACs per switch | 750K / 750K |
| max number of ARP entries IPv4 | 350K / 1M |
| max ND table size for IPv6 | 48K / 48K |
| max number of unicast routes IPv4 | 250K / 4M |
| max number of unicast routes IPv6 | 64K / 2M |
| IPv4 l2 multicast group | 2000 / 4000 |
| IPv4 l3 multicast group | 2000 / 4000 |
| IPv4 multicast routing | 16K / 16K |
| IPv6 l2 multicast group | 1000 / 2000 |
| IPv6 l3 multicast group | 1000 / 2000 |
| IPv6 multicast routing | 8K / 8K |
| LAGG group | 1024 / 1024 |
| LAGG member per group | 64 / 64 |
| ECMP group | max 2047 / max 2047 |
| ECMP member per group | 2-128 / 2-128 |
| VRF | 4095 / 4095 |
| Interface | Loopback interface number / 1K / 1K |
| L3 sub interface number | 4094 / 4094 |
| SVI interface number | 4094 / 4094 |
| VxLAN AC number | 16K / 16K |
| VxLAN VSI number | 16K / 16K |
| VxLAN tunnel number | 4K / 4K |
| VSI interface number | 8K / 8K |
| IPv4 tunnel number | 127 / 127 |
| IPv6 tunnel number | 127 / 127 |
| VLAN number | 4094 / 4094 |
| Performance | RIB / 1M / 4M |
| MSTP instance | 64 / 64 |
| PVST instance | 128 / 128 |
| PVST logical port number | 1000 / 1000 |
| VRRP VRID | 16 / 16 |
| Performance | VRRP group / 256 / 256 |
| NQA group | 32 / 32 |
| MPLS/VPLS | LDP peer / 128(local),256(remote) / 128(local),256(remote) |
| VRF | 4000 / 4000 |
| VPLS: Number of Pseudo Wires | 4000 / 4000 |
| VPLS: number of peers/single VPLS full mesh instance | 100 / 100 |
| RSVP adjacency | 200 / 200 |
| Static table | static mac-address / 20K / 20K |
| static multicast mac-address | 256 / 256 |
| static ARP | 8K / 8K |
| static ND | 1K / 1K |
| static IPv4 routing table | 250K / 250K |
| static IPv6 routing table | 128K / 128K |
| Catalog Description | |
| Description | H3C S12501X-AF Ethernet Switch Host |
| Key Features | |
| Feature 1 | Advanced CLOS+ multi-grade multi-plane switching architecture: CLOS+ multi-grade multi-plane architecture, midplane free design, providing continuous bandwidth upgrade capability. Supports industry first 48-port 40GE/ 100GE interfaces and can meet the existing and future application requirements of data centers. Adopts independent switching fabric modules |
| Feature 2 | Green: Intelligent EMS engine system - Provides smart power management that supports sequential power-on and power-off and device status check. Sequential power-on and power-off reduces power impulse and electromagnetic radiation, and increases the lifetime of the device. Additionally, device status checks can isolate faulty and idle cards to reduce power |
| Feature 3 | H3C S12501X-AF Ethernet Switch Host |
| Feature 4 | Part of the H3C S12500 Series Switches family |
| Feature 5 | Suitable for ITMall project quotation and compatibility review |
| Product Identity | |
| Brand | H3C |
| Series | H3C S12500 Series Switches |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the MPU console port specification for LS-12501X-AF?
What is the max ND table size for IPv6 specification for LS-12501X-AF?
What is the MPU slots specification for LS-12501X-AF?
What is the Maximum power consumption specification for LS-12501X-AF?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?