ITMall,Your IT Global Procurement Service Expert
H3C LS-12501X-AF Ethernet Switch
Brand H3C
N/AVerified

H3C LS-12501X-AF Ethernet Switch

Model (MPN)
0235A2DM
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock

H3C LS-12501X-AF Ethernet Switch. H3C S12501X-AF Ethernet Switch Host.

Key Specifications

MPU console port1 / 1 / 1
max ND table size for IPv648K / 48K
MPU slots2 / 2 / 2
Maximum power consumption4800 W / 9600 W / 19200W
Throughput28800Mpps / 57600Mpps / 115200Mpps
LPU slots4 / 8 / 16
Your Price
Best Value
$56,257.00
Availability Out of Stock
Quantity

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

H3C LS-12501X-AF Ethernet Switch is H3C S12501X-AF Ethernet Switch Host.

Specifications

Key Specifications
MPU console port1 / 1 / 1
max ND table size for IPv648K / 48K
MPU slots2 / 2 / 2
Maximum power consumption4800 W / 9600 W / 19200W
Throughput28800Mpps / 57600Mpps / 115200Mpps
LPU slots4 / 8 / 16
Product Specifications
Switching capacity57.6T/387Tbps / 115.2T/516Tbps / 230.4T/1032Tbps
Throughput28800Mpps / 57600Mpps / 115200Mpps
MPU slots2 / 2 / 2
LPU slots4 / 8 / 16
Maximum power consumption4800 W / 9600 W / 19200W
Weight (full configuration)≤ 100 kg≤ 220.5 lb / ≤ 190 kg≤ 418.9 lb / ≤ 350 kg≤ 771.6 lb
Dimensions (H x W x D)264 x 440 x 857 mm (6U)10.4 x 17.3 x 33.7 in / 531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in / 931 x 440 x 857 mm (21U)36.7 x 17.3 x 33.7 in
Switching fabric module slots6 / 6 / 6
MPU nameLSXM1SUP04B1 / LSXM1SUP04H1 / LSXM1SUPB1 / LSXM1SUPH1 / LSXM1SUPB1 / LSXM1SUPH1
MPU processorQuad Core 1.2 GHz / Quad Core 1.2 GHz / Quad Core 1.2 GHz
MPU SDRAM8 GB / 16 GB / 8 GB / 16 GB / 8 GB / 16 GB
MPU flash1 GB / 1 GB / 1 GB
MPU console port1 / 1 / 1
MPU MGMT ports2x 10/100/1000M Base-T2x 1000M SFP / 2x 10/100/1000M Base-T2x 1000M SFP / 1x 10/100/1000M Base-T1x 1000M SFP / 2x 10/100/1000M Base-T2x 1000M SFP / 1x 10/100/1000M Base-T1x 1000M SFP
MPU USB port1 / 1 / 1
RedundancyRedundant MPUs, switching fabric modules, power modules, and fan trays
Product Specifications
Device virtualizationIRF
Network virtualizationBGP-EVPNVxLAN
VXLANL2 VxLAN gatewayL3 VxLAN gatewayDistributed VxLAN gatewayCentralized VxLAN gatewayEVPN VxLANmanual configured VxLANIPv4 VxLAN tunnel
ProgrammabilityOpenflow1.3NetconfAnsiblePython / TCL/Restful API to realize DevOps automated operation and maintenance
Traffic analysisSflow
VLANPort-based VLANsVLAN mappingL2PTMVRP(Multiple VLAN Registration Protocol)
MAC addressDynamic learning and aging of mac address entriesDynamic,static and blackhole entries
IPv4 routing (Hardware-based unicast routing)RIP(Routing Information Protocol) v1/2OSPF (Open Shortest Path First) v1/v2ISIS(Intermediate System to Intermediate system)BGP (Border Gateway Protocol)Routing policyVRRPPBRICMP
IPv6 routing (Hardware-based unicast routing)RIPngOSPFv3IPv6 ISISBGP4+Routing policyVRRPPBRIPv6 ICMP
IP ServiceDHCP Server, DHCP Relay, DHCP SnoopingDHCP server of 3K operations/second
MPLS/VPLSSupport L3 MPLS VPNSupport MCEVPLSSupport MPLS OAMSupport P/PE functionSupport LDP protocol
Multicast (Hardware-based multicast routing)IGMP snoopingMLD snoopingIPv4 and IPv6 multicast VLANIPv4 and IPv6 PIM snoopingIGMP and MLDPIM and IPv6 PIM, Any-RPMSDP
TelemetryERSPANPacket capture
QOSWeighted Random Early Detection (WRED) and tail dropFlexible queue scheduling algorithms based on port and queue, including strict priority (SP), Weighted Deficit Round Robin (WDRR), Weighted Fair Queuing (WFQ), SP + WDRR, and SP + WFQ. Traffic shapingCOPP
Configuration and maintenanceConsole telnet and SSH terminalsSNMPv1/v2/v3ZTP
Configuration and maintenanceSystem logFile upload and download via FTP/TFTPBootRom update and remote updateNQAping,tracert NTP
Security and managementHierarchical management and password protection of usersAuthentication methods,including AAA,RADIUS and HWTACACSSupport DDos, ARP attack and ICMP attack functionSSH 2.0HTTPSSSLPKIBoot ROM access control (password recovery)RMONpermit third party transceivers (license)
HAIndependent switching fabric modules1+1 redundancy or key components such as MPUs and power modulesN+1 redundancy for switching fabric modulesPassive backplaneCLOS+ midplane free design (12500X-AF)Hot swapping for all componentsReal-time data backup on active/standby MPUs
HAHot patchingNSR/GR for OSFP/BGP/IS-IS/RSVP Port aggregation and multi-card link aggregationBFD for VRRP/BGP/IS-IS/OSPF/RSVP/static routing, with a failover time less than 50 millisecondsIP FRR and TE FRR with a switchover time less than 50 millisecond
IEEE standard802.3ab/802.3ae/802.3z/802.3x/802.3ad802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG802.1x/802.1Qbb/802.1az/802.1Qaz
RFCRFC793/RFC2328/RFC1256/RFC1771/RFC1185/RFC1191/RFC1195/RFC1195/RFC1212/RFC1213/RFC1213/RFC1213/RFC1215/RFC1245/RFC1246/RFC1256/RFC1256/RFC1265/RFC1266/RFC1268/RFC1271/RFC1284/RFC1286/RFC1305/RFC1305/RFC1305/RFC1321/RFC1323
EMCFCC Part 15 (CFR 47) CLASS AICES-003 CLASS AVCCI CISPR 32 CLASS ACISPR 22 CLASS AEN 55022 CLASS AAS/NZS CISPR22 CLASS ACISPR 32 CLASS AEN 55032 CLASS AAS/NZS CISPR32 CLASS ACISPR 24EN 55024EN 61000-3-2EN 61000-3-3ETSI EN 300 386
TemperatureOperating temperature: 0°C to 40°C (32°F to 104°F)Storage temperature: -40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
Environmental protectionWEEE and RoHS
SafetyUL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter J GB 4943.1
Product Specifications
VirtualizationIRF2.0 stack / 2 / 2
M-LAG device number2 / 2
ACLmax number of ingress ACLs / 40K / 40K
max number of ingress Car8K / 8K
max number of ingress Counter8K / 8K
max number of egress ACLs20K / 20K
max number of egress Counter4K / 4K
Forwarding tableJumbo frame length(byte) / 12288 / 12288
Mirroring group15 / 15
PBR policy1000 / 1000
PBR node256 / 256
max number of MACs per switch750K / 750K
max number of ARP entries IPv4350K / 1M
max ND table size for IPv648K / 48K
max number of unicast routes IPv4250K / 4M
max number of unicast routes IPv664K / 2M
IPv4 l2 multicast group2000 / 4000
IPv4 l3 multicast group2000 / 4000
IPv4 multicast routing16K / 16K
IPv6 l2 multicast group1000 / 2000
IPv6 l3 multicast group1000 / 2000
IPv6 multicast routing8K / 8K
LAGG group1024 / 1024
LAGG member per group64 / 64
ECMP groupmax 2047 / max 2047
ECMP member per group2-128 / 2-128
VRF4095 / 4095
InterfaceLoopback interface number / 1K / 1K
L3 sub interface number4094 / 4094
SVI interface number4094 / 4094
VxLAN AC number16K / 16K
VxLAN VSI number16K / 16K
VxLAN tunnel number4K / 4K
VSI interface number8K / 8K
IPv4 tunnel number127 / 127
IPv6 tunnel number127 / 127
VLAN number4094 / 4094
PerformanceRIB / 1M / 4M
MSTP instance64 / 64
PVST instance128 / 128
PVST logical port number1000 / 1000
VRRP VRID16 / 16
PerformanceVRRP group / 256 / 256
NQA group32 / 32
MPLS/VPLSLDP peer / 128(local),256(remote) / 128(local),256(remote)
VRF4000 / 4000
VPLS: Number of Pseudo Wires4000 / 4000
VPLS: number of peers/single VPLS full mesh instance100 / 100
RSVP adjacency200 / 200
Static tablestatic mac-address / 20K / 20K
static multicast mac-address256 / 256
static ARP8K / 8K
static ND1K / 1K
static IPv4 routing table250K / 250K
static IPv6 routing table128K / 128K
Catalog Description
DescriptionH3C S12501X-AF Ethernet Switch Host
Key Features
Feature 1Advanced CLOS+ multi-grade multi-plane switching architecture: CLOS+ multi-grade multi-plane architecture, midplane free design, providing continuous bandwidth upgrade capability. Supports industry first 48-port 40GE/ 100GE interfaces and can meet the existing and future application requirements of data centers. Adopts independent switching fabric modules
Feature 2Green: Intelligent EMS engine system - Provides smart power management that supports sequential power-on and power-off and device status check. Sequential power-on and power-off reduces power impulse and electromagnetic radiation, and increases the lifetime of the device. Additionally, device status checks can isolate faulty and idle cards to reduce power
Feature 3H3C S12501X-AF Ethernet Switch Host
Feature 4Part of the H3C S12500 Series Switches family
Feature 5Suitable for ITMall project quotation and compatibility review
Product Identity
BrandH3C
SeriesH3C S12500 Series Switches

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

FAQ

What is the MPU console port specification for LS-12501X-AF?
LS-12501X-AF lists MPU console port as 1 / 1 / 1. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the max ND table size for IPv6 specification for LS-12501X-AF?
LS-12501X-AF lists max ND table size for IPv6 as 48K / 48K. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the MPU slots specification for LS-12501X-AF?
LS-12501X-AF lists MPU slots as 2 / 2 / 2. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Maximum power consumption specification for LS-12501X-AF?
LS-12501X-AF lists Maximum power consumption as 4800 W / 9600 W / 19200W. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?