ITMall,Your IT Global Procurement Service Expert
H3C LS-12508G-AF Ethernet Switch
Brand H3C
N/AVerified

H3C LS-12508G-AF Ethernet Switch

Model (MPN)
0235A57D
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock

H3C LS-12508G-AF Ethernet Switch. H3C S12508G-AF Ethernet Switch Host.

Key Specifications

Switching capacity115.2T/516Tbps
MPU console port1
Dimensions (H x W x D)531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in
Weight (full configuration)≤ 190 kg≤ 418.9 lb
MPU slots2
Maximum power consumption12000 W
Your Price
Best Value
$50,000.00
Availability Out of Stock
Quantity

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

H3C LS-12508G-AF Ethernet Switch is H3C S12508G-AF Ethernet Switch Host.

Specifications

Key Specifications
Switching capacity115.2T/516Tbps
MPU console port1
Dimensions (H x W x D)531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in
Weight (full configuration)≤ 190 kg≤ 418.9 lb
MPU slots2
Maximum power consumption12000 W
Product Specifications
Buffer32M(T series LPU)36M(S series LPU)
Switching capacity115.2T/516Tbps
Throughput43200Mpps
MPU slots2
LPU slots8
Maximum power consumption12000 W
Weight (full configuration)≤ 190 kg≤ 418.9 lb
Dimensions (H x W x D)531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in
Switching fabric module slots6
MPU nameLSXM2SUPT2
MPU processorQuad Core 2.2GHz
MPU SDRAM16 GB
MPU flashT series: 8 GBLSXM1SUPS2 used in the S12508G-AF: 1GLSXM3SUPS2 used in the S12508G-AF/S12516G-AF:2G LSXM3SUP04S2 used in the S12504G-AF:2G
MPU console port1
MPU MGMT ports2
MPU USB port1
RedundancyRedundant MPUs, switching fabric modules, power modules, and fan trays
TemperatureOperating temperature: 0°C to 40°C (32°F to 104°F)Storage temperature: -40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
GreenSupport 802.3az energy efficient Ethernet
SafetyUL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter JGB 4943.1
Product Specifications
Device virtualizationIRF2.0M-LAG(DRNI)S-MLAG
Network virtualizationBGP-EVPNVxLAN
VXLANL2 VxLAN gatewayL3 VxLAN gatewayDistributed VxLAN gatewayCentralized VxLAN gatewayEVPN VxLANmanual configured VxLANIPv4 VxLAN tunnelIPv6 VxLAN tunnelQinQ VxLAN accessVxLAN DCI, vxlan mapping and route regeneration to interconnect DCs by L2 and L3VxLAN multicastEVPN-VxLAN multicast
MPLS/VPLSSupport L3 MPLS VPNSupport L2 VPN: VLL (Martini, Kompella)Support MCESupport MPLS OAMSupport VPLS, VLLSupport hierarchical VPLS and QinQ+VPLS accessSupport P/PE functionSupport LDP protocol
SDNH3C SeerEngine-DC
Lossless networkPFC and ECNDCBXRDMA and ROCEPFC deadlock watchdogECN overlay
ProgrammabilityOpenflow1.3NetconfAnsiblePython/TCL/Restful API to realize DevOps automated operation and maintenance
Traffic analysisSflowNetstream(TE LPUs and S series LPUs)
VLANPort-based VLANsMac-based VLAN,Subnet-based VLAN and Protocol VLANVLAN mappingQinQMVRP(Multiple VLAN Registration Protocol)Super VLANPVLAN
MAC addressDynamic learning and aging of mac address entriesDynamic,static and blackhole entriesMac address limiting on ports
IPv4 routingStatic routing and default routingRIP(Routing Information Protocol) v1/2OSPF (Open Shortest Path First) v2ISIS(Intermediate System to Intermediate system)BGP (Border Gateway Protocol)Routing policyPBR
IPv6 routingStatic routing and default routingRIPngOSPFv3IPv6 IS ISBGP4+Routing policyPBR
MulticastIGMP snoopingMLD snoopingIPv4 and IPv6 multicast VLANIPv4 and IPv6 PIM snoopingIGMP and MLDPIM and IPv6 PIMMSDPMulticast VPN
TelemetrygRPCERSPANMirror on dropTelemetry StreamINTiNQAPacket tracePacket capture
Configuration and maintenanceConsole telnet and SSH terminalsSNMPv1/v2/v3ZTPSystem logFile upload and download via FTP/TFTPBootRom update and remote updateNQAping,tracert VxLAN ping and VxLAN tracertNTPPTP(1588v2)GIR Graceful Insertion and Removal
Security and managementMicro-SegmentationHierarchical management and password protection of usersAuthentication methods,including AAA,RADIUS and HWTACACSSupport DDos, ARP attack and ICMP attack functionIP-MAC-port binding and IP Source GuardSSH 2.0HTTPSSSLPKIBoot ROM access control (password recovery)RMON
Product Specifications
VirtualizationIRF2.0 stack / 2 / 2
M-LAG device number2 / 2
ED group8 / 8
ACLmax number of ingress ACL / 5.25K / IPv4: 26KIPv6: 8K
max number of egress ACL2048 / IPv4: 2KIPv6: 1K
Forwarding tableJumbo frame length(byte) / 9216 / 13312
Mirroring group4 / 8
PBR policy1000 / 1000
PBR node256 / 256
max number of MAC per switch288K / 576K
max number of ARP entries IPv4136K / 94K-26
max ND table size for IPv667690 / 78584
max number of unicast routes IPv4360267 / 762k
max number of unicast routes IPv6144179 / 256k
IPv4 l2 multicast group16K / 8k
IPv4 l3 multicast group16K / Standard: 4094maximum: 8177
IPv4 multicast routing256K / 16K
IPv6 l2 multicast group8K / 4k
IPv6 l3 multicast group8K / Standard: 4094maximum: 6832
IPv6 multicast routing8K / 8K
LAGG group1000 / 256
LAGG member per group32 / 255
ECMP groupmax 4K / max 2K
ECMP member per group2-128 / 2-128
VRF4095 / 4k
InterfaceLoopback interface number / 1K / 1K
L3 sub interface number500 / 4096
SVI interface number4094 / 4094
SVI second ip1K / 1K
VxLAN AC number16K / 8K
VxLAN number16K / 8K
VxLAN tunnel number9K / 4K
VSI interface number8K / 8K
IPv4 tunnel number2K / 4K
IPv6 tunnel number2K / 2K
VLAN number4096 / 4096
PerformanceRIB / 1M / 1M
MSTP instance64 / 64
PVST instance510 / 126
PVST logical port number2000 / 2000
VRRP VRID255 / 255
VRRP group256 / 256
NQA group32 / 32
Static tablestatic mac-address / 20k / 48k
static ARP136K / 94k-26
static ND1K / 1K
Static tablestatic IPv4 routing table / 360267 / 762k
static IPv6 routing table144179 / 256k
Catalog Description
DescriptionH3C S12508G-AF Ethernet Switch Host
Key Features
Feature 1Advanced CLOS+ multi-grade multi-plane switching architecture: CLOS+ multi-grade multi-plane architecture, midplane free design, providing continuous bandwidth upgrade capability, improve system bandwidth and evolution capabilities, and the capacity of the whole machine can be smoothly expanded. Supports 48-port 10G, 36-port 40GE/ 100GE interfaces and can
Feature 2Green: Intelligent EMS engine system - Provides smart power management that supports sequential power-on and power-off and device status check. Sequential power-on and power-off reduces power impulse and electromagnetic radiation, and increases the lifetime of the device. Additionally, device status checks can isolate faulty and idle cards to reduce power
Feature 3H3C S12508G-AF Ethernet Switch Host
Feature 4Part of the H3C S12500 Series Switches family
Feature 5Suitable for ITMall project quotation and compatibility review
Product Identity
BrandH3C
SeriesH3C S12500 Series Switches

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

FAQ

What is the Switching capacity specification for LS-12508G-AF?
LS-12508G-AF lists Switching capacity as 115.2T/516Tbps. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the MPU console port specification for LS-12508G-AF?
LS-12508G-AF lists MPU console port as 1. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Dimensions (H x W x D) specification for LS-12508G-AF?
LS-12508G-AF lists Dimensions (H x W x D) as 531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Weight (full configuration) specification for LS-12508G-AF?
LS-12508G-AF lists Weight (full configuration) as ≤ 190 kg≤ 418.9 lb. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?