H3C LS-5500V2-28C-EI Layer 3 Ethernet Switch Chassis, supports 24 10/100/1000BASE-T ports (including 8 SFP Combo ports), 4 1G/10GBASE-X SFP+ ports, and 1 slot

H3C LS-5500V2-28C-EI
H3C LS-5500V2-28C-EI Layer 3 Ethernet Switch Chassis, supports 24 10/100/1000BASE-T ports (including 8 SFP Combo ports), 4 1G/10GBASE-X SFP+ ports, and 1 slot. Switching Capacity: 1.36Tbps/13.6Tbps. Packet Forwarding Rate: 228Mpps/256Mpps. Front panel service port description: 24 10/100/1000BASE-T Ports (including 8 Combo ports), 4 1G/10GBASE-X SFP Plus Ports, 1 Slot
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C S5500V2-28C-EI L3 Ethernet Switch Chassis, supports 24 10/100/1000BASE-T ports (including 8 SFP Combo ports), 4 1G/10GBASE-X SFP Plus ports, and 1 slot |
| Key Specifications | |
| Switching Capacity | 1.36Tbps/13.6Tbps |
| Packet Forwarding Rate | 228Mpps/256Mpps |
| Dimensions (Width x Depth x Height) (Unit: mm) | 440×360×43.6 |
| Weight | <3.5kg |
| Input voltage | AC: Rated voltage range: 100V~240V AC, 50/60Hz DC: Input rated voltage range: -36V~-72V DC |
| Power Consumption (Static) | MIN:AC:20WMAX:AC:58W |
| Product Specifications | |
| Switching Capacity | 1.36Tbps/13.6Tbps |
| Packet Forwarding Rate | 228Mpps/256Mpps |
| Dimensions (Width x Depth x Height) (Unit: mm) | 440×360×43.6 |
| Weight | <3.5kg |
| Management port | Console Port |
| Management serial port | mini USB console,USB |
| Front panel service port description | 24 10/100/1000BASE-T Ports (including 8 Combo ports), 4 1G/10GBASE-X SFP Plus Ports, 1 Slot |
| extended slot | 1 |
| Expansion line cards | LSWM2QP2P (2-Port 40G) LSWM2SP2PM (2-Port 10G SFP+ with MACSec Interface Card) LSWM2XGT2PM (2-Port 10G BASE-T with MACSec Interface Module) LSWM2SP8P (8-Port 10G SFP+ Interface Card) LSWM4SP8PM (8-Port 10G SFP+ with MACSec Interface Module) LSPM4G4T6P (4-Port Gigabit Electrical Port + 6-Port SFP (2*Combo) Interface Module) LSPM6FWD8 (S5500V2-28C-EI Dedicated Next-Generation Firewall Module) |
| Port aggregation | Supports GE port aggregation, 10GE port aggregation, 40G aggregation, Static aggregation, Dynamic aggregation, Cross-device aggregation, 8-Port link aggregation |
| Port Features | Supports IEEE 802.3x flow control (full-duplex) Supports multicast storm suppression Supports broadcast storm suppression Supports storm suppression based on Port rate percentage Supports storm suppression based on PPS Supports storm suppression based on bps |
| Jumbo Frame | Supports maximum frame length of 10000 |
| MAC Address Table | Supports blackhole MAC address Supports Static, Dynamic MAC address assignment Supports MAC address automatic learning and aging |
| VLAN | Supports VLAN based on Port Supports VLAN based on MAC address Supports VLAN based on protocol Supports VLAN based on IP subnet Supports QinQ, flexible QinQ* Supports VLAN Mapping Supports Voice VLAN Supports SuperVLAN Supports Guest VLAN Supports PVLAN Supports MVRP |
| Layer 2 Ring Protocol | Supports STP/RSTP/MSTP Supports Smart Link Supports RRPP |
| DHCP | DHCP ClientDHCP SnoopingDHCP RelayDHCP Relay SECURITYDHCP ServerDHCP Snooping option82/DHCP Relay option82 |
| IRF2 Intelligent Elastic Architecture | Supports IRF2 intelligent elastic architecture for distributed device management, distributed link aggregation, and distributed elastic routing. Supports stacking via standard Ethernet interfaces, including local stacking and remote stacking. Supports stacking of up to 9 devices. |
| IP Routing | Supports Static routing Supports RIPv1/v2, RIPng Supports OSPFv1/v2, OSPFv3 Supports BGP4, BGP4+ for IPv6 Supports equal-cost routing, policy routing Supports VRRP/VRRPv3 |
| IPv6 | Supports Neighbor Discovery (ND) Supports Path MTU (PMTU) Supports IPv6-Ping, IPv6-Traceroute, IPv6-Telnet, IPv6-TFTP Supports Manual Configuration Tunnel Supports 6to4 Tunnel Supports ISATAP Tunnel Supports IPv6 in IPv6 Tunnel Supports IPv4 in IPv6 Tunnel Supports GRE Tunnel Supports MLD SNOOPING |
| Multicast | Supports IGMP Snooping v1/v2/v3, MLD Snooping v1/v2 Supports PIM Snooping Supports MLD Proxy Supports Multicast VLAN Supports IGMP v1/v2/v3, MLD v1/v2 Supports PIM-DM, PIM-SM, PIM-SSM Supports MSDP, MSDP for IPv6 |
| Mirroring | Supports Flow Mirroring Supports N:4-Port Mirroring Supports Local and Remote Port Mirroring |
| Supports ACL\QoS | Supports L2 (Layer 2) to L4 (Layer 4) packet filtering functions, providing flow classification based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, TCP/UDP port number, and VLAN, with IPv6 ACL support, Time Range ACL support, bidirectional ACL policies in inbound and outbound directions, ACL deployment based on VLAN, rate limiting on received and transmitted packets per Port with minimum granularity of 8Kbps, packet redirection support, 802.1p and DSCP priority remarking support, CAR (Committed Access Rate) function support, flexible queue scheduling algorithms that allow simultaneous configuration based on Port and queue, supporting SP, WRR, and SP+WRR modes, and WRED support. |
| Security Features | Supports user level management and password protection Supports 802.1X authentication/centralized MAC address authentication Maximum users per port limit Supports Guest VLANSupports RADIUS authentication Supports SSH 2.0Supports Port isolation Supports Port security Supports EADSupports DHCP Snooping to prevent rogue DHCP servers Supports dynamic ARP inspection to prevent man-in-the-middle attacks and ARP DoS attacks Supports HTTPSSupports BPDU guard, Root guard Supports uRPF (unicast reverse path forwarding) to prevent IP source address spoofing and mitigate virus and attack threats Supports binding of IP/Port/MACSupports plaintext and MD5 authentication for OSPF and RIPv2 packets Supports PKI (Public Key Infrastructure) |
| Management and Maintenance | Supports XModem/FTP/TFTP loading and upgrade, Supports Command Line Interface (CLI), Telnet, Console port for configuration, Supports SNMPv1/v2/v3, WEB management, Supports RMON (Remote Monitoring) alarms, events, historical records, Supports iMC intelligent management center, Supports system logs, hierarchical alarms, debug information output, Supports NTP, Supports Power Supply alarms, Fan, temperature alarms, Supports Ping, Tracert, Supports VCT (Virtual Cable Test) cable detection function, Supports DLDP (Device Link Detection Protocol) unidirectional link detection protocol, Supports LLDP, Supports Loopback-detection Port loop detection |
| Green Energy Saving | Port automatic Power down function, Port scheduled Power down function (Schedule job) |
| Input voltage | AC: Rated voltage range: 100V~240V AC, 50/60Hz DC: Input rated voltage range: -36V~-72V DC |
| Power Consumption (Static) | MIN:AC:20WMAX:AC:58W |
| Operating Environment Temperature | 0℃~45℃ |
| Operating Ambient Relative Humidity (Non-condensing) | 10%-90% |
| Ordering Information | |
| SFP Gigabit Port | |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A12T | SFP-FE-LX-SM1310-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1310/RX 1550 nm, 15 km, LC) |
| 0231A12U | SFP-FE-LX-SM1550-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1550/RX 1310 nm, 15 km, LC) |
| 0231A0LU | 0231A0LU - S5500V2EI |
| 0231A564 | SFP-FE-LX-SM1310-A - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A965 | SFP-FE-LX-SM1310-D - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A0LP | 0231A0LP - S5500V2EI |
| 0231A320 | SFP-FE-SX-MM1310-A - Optical Module—SFP 100M/155M Multimode Module (1310 nm, 2 km, LC) |
| 0231A089 | SFP-FE-LH40-SM1310 - Optical Module - SFP 100M/155M Single-Mode Module - (1310nm, 40km, LC) |
| 0231A090 | SFP-FE-LH80-SM1550 - Optical Module—SFP 100M/155M Single-Mode Long-Distance Module—(1550 nm, 80 km, LC) |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI - SFP Gigabit BIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC) |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI - SFPGigabitBIDI Optical Module (TX 1490/RX 1550 nm, 70 km, LC) |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1310 nm, 40 km, LC) |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC) |
| 0231A54T | SFP-STACK-Kit - SFP Stacking Cable—(150 cm, includes stacking module) |
| 0231ADWF | SFP-GE-LH20-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,20km,LC) |
| 0231ADWE | SFP-GE-LH40-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,40km,LC) |
| 0231A0HL | 0231A0HL - S5500V2EI |
| 0231A0LS | 0231A0LS - S5500V2EI |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A0LQ | 0231A0LQ - S5500V2EI |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A0HK | 0231A0HK - S5500V2EI |
| 0231A11U | SFP-GE-LX-SM1310-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1310/RX 1490, 10 km, LC |
| 0231A11V | SFP-GE-LX-SM1490-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1490/RX 1310, 10 km, LC |
| 0231AEUP | SFP-GE-SX-MM850-S - SFPGigabit Optical Module(850nm,550m,SX,LC) |
| 0231AEUN | SFP-GE-LX-SM1310-S - SFPGigabit Optical Module(1310nm,10km,LX,LC) |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| SFP+ 10G Port | |
| 0231A3TA | SFP-XG-D-AOC-10M - SFP+ to SFP+10m AOC |
| 0231A3TB | SFP-XG-D-AOC-20M - SFP+ to SFP+20m AOC |
| 0231A3T9 | SFP-XG-D-AOC-7M - SFP+ to SFP+7m AOC |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231AEUQ | SFP-XG-LX-SM1310-S - SFP+ 10G Optical Module(1310nm,10km,LX,LC) |
| 0231AEUM | SFP-XG-SX-MM850-S - SFP+ 10G Optical Module(850nm,300m,SX,LC) |
| 0231A0A8 | SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A0A6 | SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231ALXU | SFP-XG-LX-SM1310-F - SFP+ All-Optical 3.010G Optical Module(1310nm,10km,SM,LC) |
| 0231A0AK | LSWM1STK - SFP+Cable0.65m |
| 0231A0AL | LSWM2STK - SFP+Cable1.2m |
| 0231A0AM | LSWM3STK - SFP+Cable3m |
| 0231A0G1 | LSTM1STK - SFP+Cable5m |
| Power Supply | |
| 0231A1U0 | LSPM2150A - 150W Asset ManagementAC Power Module |
| 0231A1U2 | LSPM5150D - 150W Asset Management DC power Module (Power Supply with Front-Facing Air Exhaust) |
| 9801A2Q0 | CA-70A12 - Pluggable AC (70W) Power Module |
| Power Supply Cable | |
| 0404A0K4 | CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard |
| 0404A27M | CAB-AC-0.6m-CHN-51005 - PDUPower Supply Cable-0.6m-3*0.75mm^2-Black-(C14 Connector(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard |
| 0404A27L | CAB-AC-1.0m-CHN-51004 - PDUPower Supply Cable-1.0m-3*0.75mm^2-Black-(C14 Connector(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard |
| 0404A1W1 | CAB-AC PWR-3m-CHN-50905 - PDU Power Supply Cable - 3.0 m - 3 × 1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - National Standard |
| 0404A0U5 | CAB-HVDC PWR-2m-PDU - PDU Power Supply Cable - 2.0 m - 3 × 1.0 mm² - Yellow 121C - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - Chinese Standard |
| 0404A02W | CAB-C13-C14-1.0m - PDU Power Supply Cable - 1.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - GB Standard |
| 0404A098 | CAB-C13-C14-1.5m - PDU Power Supply Cable - 1.5 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250 V 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - National Standard |
| 0404A02X | CAB-C13-C14-2.0m - PDU Power Supply Cable - 2.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male, 250 V, 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female, 250 V, 10 A) - Chinese National Standard |
| 0404A0W5 | CAB-PDU PWR-5m-C13/C14 - PDU Power Supply Cable - 5.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250 V 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - Chinese Standard |
| 0404A1GY | Cab-PDU-C14-3m-C13-CHN - PDU Power Supply Cable - 3.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male, 250 V, 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female, 250 V, 10 A) - Chinese National Standard |
| 0404A19E | 0404A19E - S5500V2EI |
| 0404A0GF | CAB-HVDC-10A-PDU-3m-Y - PDU Power Supply Cable - 3.0 m - 3 × 1.0 mm² - Yellow 121C - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - National Standard |
| Configuration Cables | |
| 04042967 | CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port) |
| 0404A1EE | CAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP) |
| Security License Options | |
| 3130A1XB | LIS-F100G2-AV-1Y - H3C Sec Path F100-G2 AV antivirus security service license certificate,1 year |
| 3130A1XA | LIS-F100G2-IPS-1Y - H3C Sec Path F100-G2 IPS signature database update service license certificate,1 year |
| 3130A1XX | LIS-F100G2-SSL-100 - H3C Sec Path F100-G2 SSL VPN 100 x user license certificate |
| 3130A1XW | LIS-F100G2-SSL-30 - H3C Sec Path F100-G2 SSL VPN 30 x user license certificate |
| 3130A1XC | LIS-F100G2-ACG-1Y - H3C Sec Path F100-G2 application identificationsignature database update service license certificate,1 year |
| 3130A2CF | LIS-F100G2-LB - H3C Sec Path F100G2,LBlicense certificate |
| 3130A374 | LIS-F100G2-URL-1Y - H3C Sec Path F100G2 URLsignature database update service license certificate,1 year |
| 3130A37L | LIS-F100G2-URL-3Y - H3C Sec Path F100G2 URLsignature database update service license certificate,3 years |
| Product Identity | |
| Brand | H3C |
| Series | H3C S5500V2-EI Series Switch |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Switching Capacity specification for LS-5500V2-28C-EI?
What is the Packet Forwarding Rate specification for LS-5500V2-28C-EI?
What is the Management port specification for LS-5500V2-28C-EI?
What is the Dimensions (W x D x H) (Unit: Mm) specification for LS-5500V2-28C-EI?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?