H3C LS-6520XP-54XG-EI-G Ethernet Switch(48*SFP++4*QSFP28+2*QSFP+), No Power Supply, No Fan

H3C LS-6520XP-54XG-EI-G
H3C LS-6520XP-54XG-EI-G Ethernet Switch(48*SFP++4*QSFP28+2*QSFP+), No Power Supply, No Fan. Switching Capacity: 4.8Tbps/48T. Packet Forwarding Rate: 2000Mpps. Management Ethernet port: 2, located on the rear panel 1*10/100/1000Base-T RJ-45 port 1*1000M full-duplex SFP interface
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C S6520XP-54XG-EI-GEthernet Switch(48*SFP Plus+4*QSFP28+2*QSFP Plus),No Power Supply,No Fan |
| Key Specifications | |
| Switching Capacity | 4.8Tbps/48T |
| Packet Forwarding Rate | 2000Mpps |
| Management Ethernet port | 2, located on the rear panel 1*10/100/1000Base-T RJ-45 port 1*1000M full-duplex SFP interface |
| 1/10GE SFP+ Port | 48 ports |
| 40GE QSFP+ port | 2 ports |
| 40/100GE QSFP28-Port | 4 ports |
| Product Specifications | |
| Switching Capacity | 4.8Tbps/48T |
| Packet Forwarding Rate | 2000Mpps |
| Dimensions (Width x Depth x Height) (Unit: mm) | 440×400×43.6 |
| Full Configuration Weight | ≤10kg |
| Console Port | 1, located on the rear panel |
| Management Ethernet port | 2, located on the rear panel 1*10/100/1000Base-T RJ-45 port 1*1000M full-duplex SFP interface |
| USB port | 1 (full speed), located on the rear panel |
| 1/10GE SFP+ Port | 48 ports |
| 40GE QSFP+ port | 2 ports |
| 40/100GE QSFP28-Port | 4 ports |
| Input voltage | Rated voltage range: 100V~240V AC, 50/60Hz; Maximum voltage range: 90V~264V AC, 47/63Hz |
| DC | Rated voltage range: -48V~-60V DC |
| Fan | Fan is hot-swappable |
| Power consumption (W when fully loaded) | 250 |
| Operating Environment Temperature | 0ºC~45ºC |
| Operating Ambient Relative Humidity (Non-condensing) | 10%~90% |
| Forwarding Mode | Supports store-forward mode and cut-through mode. |
| Link aggregation | Supports 10GE Port aggregation, 40GE Port aggregation, Static aggregation, Dynamic aggregation |
| Jumbo Frame | Supports |
| MAC Address Table | Supports Static MAC address, Blackhole MAC address, Port MAC address configuration, Maximum number of MAC addresses learned per port |
| VLAN | Supports Port-based VLAN (4094), Guest VLAN, Voice VLAN, Default VLAN, QINQ, Flexible QINQ, VLAN MAPPING, PVST+, RPVST+ |
| Traffic Monitoring | Support s Flow |
| DHCP | DHCP ClientDHCP SnoopingDHCP RelayDHCP ServerDHCP Snooping option82/DHCP Relay option82 |
| ARP | Supports Static entries, Supports free ARP, Supports standard proxy ARP and local proxy ARP, Supports Dynamic ARP Inspection, Supports ARP anti-attack, Supports ARP source suppression, Supports ARP Detection function (can check according to DHCP Snooping security table entries, 802.1x table entries, or IP/MAC Static binding table entries) |
| Routing protocols | Supports IPv4/IPv6 Static routing, RIP and other Layer 3 dynamic routing protocols, Policy routing; Supports RIP v1/v2, RIPng, Equal-cost routing, VRRP, OSPFv1/v2, OSPF v3, BGP, ISIS and other enhanced Layer 3 routing protocols |
| IPv6 Features | Supports Neighbor Discovery (ND), PMTU, ICMP v6, Telnet v6, SFTP v6, SNMP v6, BFD v6, VRRP v3, BGP4+, ISISv6, IPv6-Portal, IPv6 tunnel |
| Multicast Protocol | Supports IGMP Snooping v2/v3, IGMP Snooping Fast-leave, IGMP Snooping Group-policy, PIM-SM, PIM-SSM, PIM snooping, MVRP, MFF, Enhanced Three-layer Multicast Protocol |
| Zero Configuration | Supports CWMP-TR069 and other zero-configuration methods |
| Broadcast/Multicast/Unicast storm suppression | Supports Storm suppression based on Port rate percentage, Storm suppression based on pps, Storm suppression based on bps |
| Layer 2 Ring Protocol | Supports STP/RSTP/MSTP protocols, STP Root Guard, BPDU Guard, ERPS Ethernet Ring Protection Protocol (G.8032) |
| QoS/ACL | Supports rate limiting on both received and transmitted packets per Port. Supports CAR functionality. Supports dual-rate three-color CAR functionality. Each Port supports 8 output queues. Supports flexible queue scheduling algorithms, with settings available at both Port and queue levels. Supports multiple scheduling modes including SP, WDRR, and SP+WDRR. Supports re-marking of 802.1p and DSCP priorities. Provides L2 (Layer 2) to L4 (Layer 4) packet filtering functions, offering flow classification based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, Port, protocol, and VLAN. Supports Time Range. Supports WRED. |
| Mirroring | Supports flow Mirroring. Supports N:1-Port Mirroring. Supports local and remote Port Mirroring. |
| MPLS | Supports MPLS L3VPN |
| Reliability | Supports BFD for Static, IS-IS, OSPF, RIP, BGP, IPv6 Static, OSPFv3, PIM, and Track routing. Supports BPDU protection, root protection, and loop protection. Supports port role limitation and TC-BPDU propagation limitation. Supports protection against TC-BPDU attack. Supports PVST message protection for MSTP. Supports Smart Link. Supports hardware BFD (minimum 3ms packet interval). |
| Security Features | Supports user level management and password protection. Supports centralized MAC authentication. Supports 802.1X. Supports storm control. Supports AAA authentication. Supports RADIUS authentication. Supports HWTACACS. Supports SSH 2.0. Supports port isolation. Supports IP+MAC+Port binding. Supports plaintext and MD5 encrypted authentication for dynamic routing protocols. Supports route redistribution. Supports IP Source Guard. Supports HTTPS. Supports SSL. Supports PKI (Public Key Infrastructure). Supports CPU protection. |
| Loading and Upgrade | Supports XModem protocol for loading and upgrading Supports FTP (File Transfer Protocol) for loading and upgrading Supports TFTP (Trivial File Transfer Protocol) for loading and upgrading |
| Management and Maintenance | Supports Command Line Interface (CLI) Configuration Supports Telnet Remote Configuration Supports Console Port Configuration Supports schedule job Supports ISSU Supports SNMP (Simple Network Management Protocol) Supports IMC Network Management System Supports System Log Supports Hierarchical Alarm Supports NTP Supports Power Supply Alarm Function Supports Fan and Temperature Alarm Supports Debug Information Output Supports Ping, Tracert Supports Track Supports Telnet Remote Maintenance Supports USB for File Upload and Download |
| Power Consumption (Static) | Single AC: 72W Dual AC: 86W |
| Power consumption (at full load) | Single AC: 165W Dual AC: 175W |
| Ordering Information | |
| SFP/SFP+10GOptical Port | |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A11U | SFP-GE-LX-SM1310-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1310/RX 1490, 10 km, LC |
| 0231A11V | SFP-GE-LX-SM1490-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1490/RX 1310, 10 km, LC |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| 0231AJXK | SFP-2.5G-LX10-SM1310-DR-I - SFP 2.5G/1G Single-Mode Industrial-Temperature Optical Module (1310 nm, 10 km, LC) |
| 0231AH0W | SFP-10GE-T - SFP+ 10GEElectrical Port Module(Cat6a/Cat7,30m,RJ45) |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231A0A8 | SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A0A6 | SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A0AK | LSWM1STK - SFP+Cable0.65m |
| 0231A0AL | LSWM2STK - SFP+Cable1.2m |
| 0231A0AM | LSWM3STK - SFP+Cable3m |
| 0231A0G1 | LSTM1STK - SFP+Cable5m |
| QSFP+ Port | |
| 0231A1LS | LSWM1QSTK0 - 40G QSFP+ 1m Cable |
| 0231A1LT | LSWM1QSTK1 - 40G QSFP+ 3m Cable |
| 0231A1LU | LSWM1QSTK2 - 40G QSFP+ 5m Cable |
| 0231A3U4 | QSFP-40G-D-AOC-10M - 40G QSFP+ to 40G QSFP+10m AOC |
| 0231A3U5 | QSFP-40G-D-AOC-20M - 40G QSFP+ to 40G QSFP+20m AOC |
| 0231A3U3 | QSFP-40G-D-AOC-7M - 40G QSFP+ to 40G QSFP+7m AOC |
| 0231A2E4 | QSFP-40G-LR4-WDM1300 - QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC) |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850 - QSFP+ 40G BIDI Optical Module (850 nm, 100 m, SR) |
| 0231AJHT | QSFP-40G-LX4-WDM1300 - QSFP+ 40G Optical Module (1310nm, 150m, OM3, LX4) |
| 0231A4PB | QSFP-40G-LR4L-WDM1300 - QSFP+ 40G Optical Module (1310nm, 2km, LR4L, LC) |
| 0231A4UG | QSFP-40G-ER4-WDM1300 - QSFP+ 40G Optical Module (1310 nm, 40 km, ER4, LC) |
| 0231A2NF | QSFP-40G-SR4-MM850 - QSFP+ 40G Optical Module (850 nm, 100 m, SR4, supports 1-to-4 splitting) |
| 0231A2KL | QSFP-40G-CSR4-MM850 - QSFP+ 40G Optical Module (850 nm, 300 m, CSR4, supports 1-to-4 splitting) |
| QSFP28-Port | |
| 0231A4B3 | QSFP-100G-D-AOC-10M - 100G QSFP28 to 100G QSFP28 10m AOC |
| 0231A4B4 | QSFP-100G-D-AOC-20M - 100G QSFP28 to 100G QSFP28 20m AOC |
| 0231A4B2 | QSFP-100G-D-AOC-7M - 100G QSFP28 to 100G QSFP28 7m AOC |
| 0231AFJA | QSFP-100G-ZR4-WDM1300 - 100G QSFP28 Optical Module (1300nm, 80km, ZR4, WDM, LC) |
| 0231A4UF | QSFP-100G-LR4-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 10 km, LR4, WDM, LC) |
| 0231A9V9 | QSFP-100G-CWDM4-SM1300-A - 100G QSFP28 Optical Module (1310 nm, 2 km, CWDM4, LC) |
| 0231A5LL | QSFP-100G-LR4L-WDM1300 - 100G QSFP28 Optical Module (1310nm, 2km, LR4L, CWDM4, LC) |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 40 km, ER4L, WDM, LC) |
| 0231A5HA | QSFP-100G-PSM4-SM1310 - 100G QSFP28 Optical Module (1310 nm, 500 m, PSM4, MPO/APC) |
| 0231A5UL | QSFP-100G-eSR4-MM850 - 100G QSFP28 Optical Module (850nm, 300m OM4, eSR4, MPO) |
| 0231A5H6 | 0231A5H6 - 100G QSFP28 Optical Module (850 nm, 100 m OM4, SWDM4, LC) |
| 0231A4B1 | QSFP-100G-SR4-MM850 - 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO) |
| 0231A9VA | 0231A9VA - H3C S6520X-EI-G Switch Series |
| Fan Options | |
| 0231A2VU | LSPM1FANSB - Fan Module(SW, 4028,Fan Panel Side Air Outlet) |
| 0231A2VT | LSPM1FANSA - Fan Module(SW, 4028, Fan Panel Side Air Intake) |
| Power Module | |
| 0231A6M0 | PSR250-12A - 250W AC power Module (Power Supply panel-side airflow intake) |
| 0231A8FP | PSR250-12A1 - 250W AC power Module (Power Supply panel-side airflow exhaust) |
| 0231A6NA | PSR450-12AHD - 450W High-Voltage DC power Module (Supports AC/336V High-Voltage DC, with air exhaust on the front panel) |
| 0231A6NB | PSR450-12D - 450W DC power Module (Power Supply panel-side airflow exhaust) |
| Serial Cable | |
| 04042967 | CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port) |
| Rack Rail | |
| 2150A050 | LSV-SL-S5830 - 1U long Rack Rail |
| Product Identity | |
| Brand | H3C |
| Series | H3C S6520X-EI-G Series Autonomous Switch |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Switching Capacity specification for LS-6520XP-54XG-EI-G?
What is the Packet Forwarding Rate specification for LS-6520XP-54XG-EI-G?
What is the Console Port specification for LS-6520XP-54XG-EI-G?
What is the Dimensions (Width x Depth x Height) (Unit: mm) specification for LS-6520XP-54XG-EI-G?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?