ITMall,Your IT Global Procurement Service Expert
H3C LS-6850-56HF-CP
Brand H3C
N/AVerified

H3C LS-6850-56HF-CP

Model (MPN)
0235A4P5
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock

H3C LS-6850-56HF-CP Cold Plate Liquid Cooled Layer 3 Ethernet Switch (48*SFP28+8*QSFP28). Switching Capacity: 4Tbps. Packet Forwarding Rate: 2000Mpps. Out-of-band Management Ethernet Port: 1 x 100/1000BASE-T

Key Specifications

DescriptionH3C S6850-56HF-CP Cold Plate Liquid Cooled L3 Ethernet Switch (48*SFP28+8*QSFP28)
Switching Capacity4Tbps
Packet Forwarding Rate2000Mpps
Out-of-band Management Ethernet Port1 x 100/1000BASE-T
100GE QSFP28 port8 units
25GE SFP28 port48 ports
Your Price
Best Value
$6,599.95
List Price: $94,285.00Save 93%
Availability Out of Stock
Quantity

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

H3C LS-6850-56HF-CP Cold Plate Liquid Cooled Layer 3 Ethernet Switch (48*SFP28+8*QSFP28)

Specifications

Catalog Description
DescriptionH3C S6850-56HF-CP Cold Plate Liquid Cooled L3 Ethernet Switch (48*SFP28+8*QSFP28)
Key Specifications
Switching Capacity4Tbps
Packet Forwarding Rate2000Mpps
Out-of-band Management Ethernet Port1 x 100/1000BASE-T
100GE QSFP28 port8 units
25GE SFP28 port48 ports
Dimensions (Width x Depth x Height) (Unit: mm)440×400×44
Product Specifications
Dimensions (Width x Depth x Height) (Unit: mm)440×400×44
Full Configuration Weight≤9kg
Serial Console port (RJ45)1
Out-of-band Management Ethernet Port1 x 100/1000BASE-T
USB port1 USB 2.0 interface
100GE QSFP28 port8 units
25GE SFP28 port48 ports
Input voltage90v~264v
Power ModuleDual Modular Power Supply
Cooling methodCold plate liquid cooling, Air cooling
Coolant modelDow Corning: PG25 Propylene glycol aqueous solution
Connector typeUQD02-T04BSSJE (Blue) UQD02-T04RSSJE (Red)
Fan Module4 Hot-swappable Fan Modules, Front-to-Back Ventilation
Power Consumption (Static)Single AC: 91W Dual AC: 97W
Power Consumption (Typical)Single AC: 143W Dual AC: 150W
Operating Environment Temperature0ºC~45ºC
Coolant Inlet Temperature≤45ºC
Coolant System Pressure Drop (Bar)≤40kPa
Coolant System Flow Rate (L/min)≤1.5 L/min
Operating environment relative humidity5%~95%, Non-condensing
Switching Capacity4Tbps
Packet Forwarding Rate2000Mpps
Forwarding ModeSupports store-forward mode and cut-through mode.
Device VirtualizationSupports IRF2 intelligent resilient architecture, local and remote stacking Supports distributed device management, distributed link aggregation, distributed resilient routing Supports cross-device link aggregation DRNI
Network VirtualizationSupport for VxLAN Layer 2 and Layer 3 gateways Support for BGP-EVPN Support for Emulate-ping vxlan, VxLAN Tracert, etc. Support for QinQ in VxLAN Support for GRE Tunnel
SDN ControllerSupports ADDC
Data Center FeaturesSupport VxLAN MappingSupport service chainService chainSupport RoCE v2 Lossless NetworkingSupport FCoESupport DCBX, PFC, ETS, ECN, QCN
ProgrammableSupports Open Flow, Ansible automation Configuration
MAC Address TableSupports dynamic, static, and blackhole MAC address table entries. Supports MAC address auto-learning and aging. Supports source MAC address filtering.
VLANSupports Port-based, Protocol-based, MAC-based VLAN. Supports Default VLAN. Supports PVLAN. Supports Super VLAN. Supports Voice VLAN. Supports QinQ and Flexible QinQ.
Traffic MonitoringSupports s Flow/Net Stream Supports Telemetry Supports INT (In-band Network Telemetry)
DHCPDHCP Server and DHCP Client; DHCP Snooping and DHCP Relay
ARPSupports ARP, RARP, and Gratuitous ARP. Supports Dynamic ARP Inspection. Supports ARP anti-attack. Supports ARP source suppression. Supports ARP Detection function.
IP RoutingSupports static routing and default routing. Supports IPv4 dynamic routing protocols such as RIP, OSPF, BGP, ISIS. Supports IPv6 dynamic routing protocols such as RIPng, OSPFv3, BGP4+, ISISv6. Supports equal-cost routing and policy-based routing.
IPv6 FeaturesSupports IPv6 ND (Neighbor Discovery), Supports IPv6 VxLAN over IPv4, Supports PMTU Discovery (Path MTU Discovery), Supports ICMPv6, Telnetv6, SFTPv6, SNMPv6, BFDv6, VRRPv3, Supports IPv6-Portal and IPv6 Tunnel
Multicast ProtocolSupports IGMP Snooping v2/v3 Supports IGMP v1/v2/v3 Supports PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP Supports MLD Snooping Supports Multicast Policy Supports Multicast VLANs Supports Multicast Over VxLANs
MPLSSupports MPLS, MCE, MPLS VPN, VPLS, MPLS TE
ReliabilitySupports STP, RSTP, MSTP, Supports BPDU Protection, Root Protection, Loop Protection, Supports PVST, Supports LACP, Supports DLDP, Supports RRPP, Supports ERPS Ethernet Ring Protection Protocol (G.8032), Supports Smart Link, Supports BFD minimum 3.3ms packet transmission interval, Supports VRRP
QoSSupports Port transmit/receive packet rate limiting. Supports ACL, CAR, priority remarking, and queues. Supports multiple queue scheduling such as SP, WRR, WFQ, SP+WRR, SP+WFQ. Supports Layer 2~Layer 4 packet filtering. Supports flow classification based on Source MAC, Destination MAC, Source IP (IPv4/IPv6) address, Destination IP (IPv4/IPv6) address, Port, Protocol, VLAN. Supports traffic shaping. Supports congestion avoidance mechanisms such as WRED and tail drop.
MirroringSupports traffic mirroring. Supports N:4-Port mirroring. Supports local and remote Port mirroring (ERSPAN).
Security FeaturesSupports user hierarchical management and password protection Supports 802.1x, AAA, Radius, HWTACACS and other authentication Supports IP, MAC, port, VLAN combination binding Supports prevention of DOS, ARP, and ICMP attacks Supports IP Source Guard, port isolation Supports HTTPs, SSL Supports anti-DDos, ARP attack DDos, ARP and ICMP attacks
Management and MaintenanceSupported Telemetry visualization functions Supported buffer micro-burst detection Supported zero-configuration Auto-config and configuration rollback Supported command line interface (CLI) configuration Supported configuration via Console, Telnet, SSH, etc. Supported RMON (Remote Monitoring) Supported SNMP v1/v2c/v3 Supported network management system Supported Netconf and Python Supported system log and user operation log Supported hierarchical alarm Supported power, fan, and temperature alarm functions Supported NTP, SNTP network time protocol Supported Jumbo Frame Supported Ping, Tracert, and other debugging information output Supported file upload and download via FTP, TFTP, USB, etc. Supported XModem protocol for loading and firmware upgrade Supported monitoring of Power Module temperature, fan speed, etc. Supported monitoring of temperature and other information
Ordering Information
SFP28-Port
02312173SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC)
0231AJ2K0231AJ2K - S6850
0231A563SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC)
0231A962SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC)
02312170SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC)
0231A963SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC)
0231A964SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC)
0231A562SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC)
0231A961SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC)
0231A085SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45)
0231A960SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45)
0231A6NGSFP-25G-D-AOC-10M - 25G SFP28 to 25G SFP28 10m Active Optical Cable
0231AH0LSFP-25G-D-AOC-10M-H - 25G SFP28 to 25G SFP28 10m Active Optical Cable
0231A5GYSFP-25G-D-CAB-1M - 25G SFP28 to 25G SFP28 1m Passive Cable
0231A6NHSFP-25G-D-AOC-20M - 25G SFP28 to 25G SFP28 20m Active Optical Cable
0231AH0FSFP-25G-D-AOC-20M-H - 25G SFP28 to 25G SFP28 20m Active Optical Cable
0231A5H0SFP-25G-D-CAB-3M - 25G SFP28 to 25G SFP28 3m Passive Cable
0231A6NDSFP-25G-D-AOC-3M - 25G SFP28 to 25G SFP28 3m Active Optical Cable
0231A6NESFP-25G-D-AOC-5M - 25G SFP28 to 25G SFP28 5m Active Optical Cable
0231AH0MSFP-25G-D-AOC-5M-H - 25G SFP28 to 25G SFP28 5m Active Optical Cable
0231A6NFSFP-25G-D-AOC-7M - 25G SFP28 to 25G SFP28 7m Active Optical Cable
0231AH0GSFP-25G-D-AOC-7M-H - 25G SFP28 to 25G SFP28 7m Active Optical Cable
0231ABR6SFP-25G-LR-SM1310 - 25G SFP28Optical Module(1310nm,10km,LR,SM,LC)
0231A4Y2SFP-25G-SR-MM850 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC)
0231AH0DSFP-25G-SR-MM850-H - 25G SFP28Optical Module(850nm,100m,SR,MM,LC)
0231AJ2T0231AJ2T - S6850
0231AH0WSFP-10GE-T - SFP+ 10GEElectrical Port Module(Cat6a/Cat7,30m,RJ45)
0231AKBFSFP-XG-D-AOC-10M-H - SFP+ to SFP+ 10m Active Fiber Cable
0231AKBESFP-XG-D-AOC-20M-H - SFP+ to SFP+ 20m Active Fiber Cable
0231AKBKSFP-XG-D-AOC-7M-H - SFP+ to SFP+ 7m Active Fiber Cable
0231A3TASFP-XG-D-AOC-10M - SFP+ to SFP+10m AOC
0231A3TBSFP-XG-D-AOC-20M - SFP+ to SFP+20m AOC
0231A3T9SFP-XG-D-AOC-7M - SFP+ to SFP+7m AOC
0231ABSQSFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC)
0231ABSPSFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC)
0231ABSRSFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC)
0231ABSSSFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC)
0231ABSTSFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC)
0231ABSUSFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC)
0231AKBCSFP-XG-SX-MM850-H - SFP+ 10G Optical Module(850nm,300m,LC)
0231A0A8SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC)
0231A1RQSFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC)
0231A2L3SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC)
0231A0SPSFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC)
0231A1RRSFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC)
0231A1PASFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC)
0231A2T6SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC)
0231A0A6SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC)
0231A1RPSFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC)
0231A2L4SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC)
0231A0AKLSWM1STK - SFP+Cable0.65m
0231A0ALLSWM2STK - SFP+Cable1.2m
0231A0AMLSWM3STK - SFP+Cable3m
0231A0G1LSTM1STK - SFP+Cable5m
QSFP28-Port
0231A4B3QSFP-100G-D-AOC-10M - 100G QSFP28 to 100G QSFP28 10m AOC
0231AH0HQSFP-100G-D-AOC-10M-H - 100G QSFP28 to 100G QSFP28 10m Active Optical Cable
0231A4AYQSFP-100G-D-CAB-1M - 100G QSFP28 to 100G QSFP28 1m Passive Cable
0231A4B4QSFP-100G-D-AOC-20M - 100G QSFP28 to 100G QSFP28 20m AOC
0231AH0JQSFP-100G-D-AOC-20M-H - 100G QSFP28 to 100G QSFP28 20m Active Optical Cable
0231A4B0QSFP-100G-D-CAB-3M - 100G QSFP28 to 100G QSFP28 3m Passive Cable
0231A5HBQSFP-100G-D-CAB-5M - 100G QSFP28 to 100G QSFP28 5m passive cable
0231A4B2QSFP-100G-D-AOC-7M - 100G QSFP28 to 100G QSFP28 7m AOC
0231AH0KQSFP-100G-D-AOC-7M-H - 100G QSFP28 to 100G QSFP28 7m Active Optical Cable
0231A5HCQSFP-100G-4SFP-25G-CAB-1M - 100G QSFP28 to 4x25G SFP28 1m Passive Cable
0231A5HDQSFP-100G-4SFP-25G-CAB-3M - 100G QSFP28 to 4x25G SFP28 3m Passive Cable
0231AFJBQSFP-100G-ER4-WDM1300 - 100G QSFP28 Optical Module (1300nm, 40km, ER4, WDM, LC)
0231AFJAQSFP-100G-ZR4-WDM1300 - 100G QSFP28 Optical Module (1300nm, 80km, ZR4, WDM, LC)
0231A4UFQSFP-100G-LR4-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 10 km, LR4, WDM, LC)
0231AM91QSFP-100G-FR1-SM1310 - 100G QSFP28 Optical Module(1310nm,2km,FR1,LC)
0231A5LLQSFP-100G-LR4L-WDM1300 - 100G QSFP28 Optical Module (1310nm, 2km, LR4L, CWDM4, LC)
0231ABS7QSFP-100G-ER4L-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 40 km, ER4L, WDM, LC)
0231AM90QSFP-100G-DR1-SM1310 - 100G QSFP28 Singlemode Optical Module(1310nm,500m,DR1,LC)
0231A5HAQSFP-100G-PSM4-SM1310 - 100G QSFP28 Optical Module (1310 nm, 500 m, PSM4, MPO/APC)
0231A7W9QSFP-100G-BIDI-MM850 - 100G QSFP28 Optical Module (850nm, 100m OM4, BIDI, LC)
0231AH0EQSFP-100G-SR4-MM850-H - 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO)
0231A5ULQSFP-100G-eSR4-MM850 - 100G QSFP28 Optical Module (850nm, 300m OM4, eSR4, MPO)
0231AM8YQSFP-100G-LR1-SM1310-DC - 100G QSFP28 Optical Module (for Data Center)-(1310nm,10km,LR1,LC)
0231AJ2S0231AJ2S - S6850
0231AJ2R0231AJ2R - S6850
0231A5H60231A5H6 - 100G QSFP28 Optical Module (850 nm, 100 m OM4, SWDM4, LC)
0231A4B1QSFP-100G-SR4-MM850 - 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO)
0231A1LSLSWM1QSTK0 - 40G QSFP+ 1m Cable
0231A1LTLSWM1QSTK1 - 40G QSFP+ 3m Cable
0231A1LULSWM1QSTK2 - 40G QSFP+ 5m Cable
0231A9CTQSFP-40G-D-AOC-3M - 40G QSFP+ to 40G QSFP+ 3m Active Optical Cable
0231A3U4QSFP-40G-D-AOC-10M - 40G QSFP+ to 40G QSFP+10m AOC
0231A3U5QSFP-40G-D-AOC-20M - 40G QSFP+ to 40G QSFP+20m AOC
0231A3U3QSFP-40G-D-AOC-7M - 40G QSFP+ to 40G QSFP+7m AOC
0231A1LVLSWM1QSTK3 - 40G QSFP+ to 4x10G SFP+ 1m Cable
0231A1LWLSWM1QSTK4 - 40G QSFP+ to 4x10G SFP+ 3m Cable
0231A1LXLSWM1QSTK5 - 40G QSFP+ to 4x10G SFP+ 5m Cable
0231A2E4QSFP-40G-LR4-WDM1300 - QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC)
0231A4Q7QSFP-40G-BIDI-SR-MM850 - QSFP+ 40G BIDI Optical Module (850 nm, 100 m, SR)
0231A4PBQSFP-40G-LR4L-WDM1300 - QSFP+ 40G Optical Module (1310nm, 2km, LR4L, LC)
0231A4UGQSFP-40G-ER4-WDM1300 - QSFP+ 40G Optical Module (1310 nm, 40 km, ER4, LC)
0231A2UQQSFP-40G-LR4-PSM1310 - QSFP+ 40G Optical Module (1310 nm, 10 km, MPO/APC, LR4, parallel single-mode)
0231AG54QSFP-40G-LR4-PSM1310-A - QSFP+ 40G Optical Module (1310 nm, 10 km, MPO/APC, LR4, parallel single-mode)
0231A2NFQSFP-40G-SR4-MM850 - QSFP+ 40G Optical Module (850 nm, 100 m, SR4, supports 1-to-4 splitting)
0231A2KLQSFP-40G-CSR4-MM850 - QSFP+ 40G Optical Module (850 nm, 300 m, CSR4, supports 1-to-4 splitting)
0231AJ2M0231AJ2M - S6850
0231AJ2N0231AJ2N - S6850
Fan
0231AKLCFAN-40F-1-D - H3C Fan Module (air intake on the fan panel side)
0231APU6FAN-40B-1-C - Fan Module(Fan Panel Side Air Outlet, Supports Electronic Labeling)
Power Supply
0231AKX6SW-A-PSR550-12A-B - 550W AC System Power Module (Power Supply Side Outlet) (Platinum)
Serial Cable
04042967CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port)
0404A1EECAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP)
Product Identity
BrandH3C
SeriesH3C S6850 Series Switch

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

FAQ

What is the Switching capacity specification for LS-6850-56HF-CP?
LS-6850-56HF-CP lists Switching capacity as 4 Tbps / 3.6Tbps. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Serial console port specification for LS-6850-56HF-CP?
LS-6850-56HF-CP lists Serial console port as RJ45 / RJ45. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the max ND table size for IPv6 specification for LS-6850-56HF-CP?
LS-6850-56HF-CP lists max ND table size for IPv6 as 136K max. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Weight specification for LS-6850-56HF-CP?
LS-6850-56HF-CP lists Weight as ≤ 10 kg (22.05 lb) / ≤ 16 kg (35.27 lb). Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?