H3C LS-7003E Ethernet Switch Chassis

H3C LS-7003E
H3C LS-7003E Ethernet Switch Chassis. Switching Capacity: 20.8Tbps/48Tbps. IPv4Packet Forwarding Rate: 2880Mpps/16800Mpps. Physical Dimensions (Width × Height × Depth) (mm): 436 x 175 x 420 436 x 575 x 420
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C S7003EEthernet Switch Chassis |
| Key Specifications | |
| Switching Capacity | 20.8Tbps/48Tbps |
| IPv4Packet Forwarding Rate | 2880Mpps/16800Mpps |
| Physical Dimensions (Width × Height × Depth) (mm) | 436 x 175 x 420 436 x 575 x 420 |
| Fully Configured Weight (kg) | ≤27kg |
| Power Supply | DC:–48V~–60V AC: 100V~240 |
| Total slot count | 3 |
| Product Specifications | |
| Switching Capacity | 20.8Tbps/48Tbps |
| IPv4Packet Forwarding Rate | 2880Mpps/16800Mpps |
| Total slot count | 3 |
| Service Module Slot Count | 3 |
| Redundancy design | Power Supply, Supervisor Engine Module redundant |
| Layer 2 Features | Supports IEEE 802.1P (CoS priority) Supports IEEE 802.1Q (VLAN) Supports IEEE 802.1d (STP)/802.1w (RSTP)/802.1s (MSTP) Supports IEEE 802.1ad (QinQ), flexible QinQ and VLAN mapping Supports IEEE 802.3x (full-duplex flow control) and back pressure flow control (half-duplex) Supports IEEE 802.3ad (link aggregation) and cross-board link aggregation Supports IEEE 802.3 (10Base-T)/802.3u (100Base-T) Supports IEEE 802.3z (1000BASE-X)/802.3ab (1000BaseT) Supports IEEE 802.3ae (10Gbase) Supports RRPP (Rapid Ring Protection Protocol) Supports cross-board Port/flow Mirroring Supports Port broadcast/multicast/unknown unicast storm suppression Supports Jumbo Frame Supports VLAN division based on Port, protocol, subnet and MAC Supports SuperVLAN Supports PVLAN Supports Multicast VLAN+ Supports point-to-point single VLAN cross-connection, double VLAN cross-connection All forwarding relies on VLAN-ID for forwarding, N/A MAC address learning Supports maximum VLAN MAPING/flexible QinQ table entries Comprehensive VLAN MAPPING capability Supported Supports GVRP Supports LLDP |
| IPv4 Routing Features | Supports ARP Proxy, DHCP Relay, DHCP Server, Static Routing, RIPv1/v2, OSPFv2, IS-IS, BGPv4, OSPF/IS-IS/BGP GR (Graceful Restart), Equal-cost Load Balancing, Policy Routing, Routing Policy |
| IPv6 Routing Features | Supports ICMPv6, ICMPv6 Redirect, DHCPv6, ACLv6, OSPFv3, RIPng, BGP4+, IS-ISv6, Manual Tunnel, ISATAP, 6to4 Tunnel, Dual Stack of IPv6 and IPv4 |
| Multicast | Supports IGMPv1/v2/v3 Supports IGMPv1/v2/v3 Snooping Supports IGMP Filter Supports IGMP Fast leave Supports PIM-SM/PIM-DM/PIM-SSM Supports MSDP Supports Any Cast-RP Supports MLDv2/MLDv2 Snooping Supports PIM-SMv6, PIM-DMv6, PIM-SSMv6 |
| ACL/ QoS | Supports standard and extended ACL Supports VLAN-based ACL Supports Ingress/Egress ACL Supports Ingress/Egress CAR with granularity as low as 8Kbps Supports two-level Meter capabilities Supports VLAN aggregation CAR and MAC aggregation CAR functions Supports traffic shaping (Traffic Shaping) Supports 802.1P/DSCP priority Mark/Remark Supports hierarchical QoS (H-QoS) with three-level queue scheduling Supports queue scheduling mechanisms including SP, WRR, SP+WRR, CBWFQ Supports congestion avoidance mechanisms including Tail-Drop, WRED Supports Mirroring |
| SDN/ OPEN FLOW | Supports OPENFLOW 1.3 standard Supports multiple controllers (EQUAL mode, master-slave mode) Supports multi-table pipeline Supports Group table Supports Meter |
| VXLA N | Supports VXLAN Layer 2 Switching, Supports VXLAN Routing Switching, Supports VXLAN Gateway, Supports VXLAN Distributed Control Plane with IS-IS+ENDP, Supports VXLAN Centralized Control Plane with Open Flow+Netconf |
| MPLS /VPLS | Supports L3 MPLS VPN, Supports L2 VPN: VLL (Martini, Kompella), Supports MCE, Supports MPLS OAM, Supports VPLS, VLL, Supports Hierarchical VPLS, QinQ+VPLS Access, Supports P/PE Function, Supports LDP Protocol |
| Security Mechanisms | Supports EAD security solution, Portal authentication, MAC authentication, IEEE 802.1x and IEEE 802.1x SERVER, AAA/Radius, HWTACACS, supports CLI authentication, SSHv1.5/SSHv2, ACL traffic filtering mechanism, OSPF, RIPv2 and BGPv4 plaintext and MD5 encrypted authentication, CLI uses hierarchical protection to prevent unauthorized intrusion, different users have different Configuration permissions, supports limited IP address Telnet login and password mechanism, supports binding of IP address, VLAN ID, MAC address and Port in various combinations, supports uRPF, supports primary-backup data backup mechanism, supports fault alarm and self-recovery, supports data logging |
| System Management | Supports FTP, TFTP, Xmodem. Supports SNMP v1/v2/v3. Supports s Flow traffic statistics. Supports RMON. Supports NTP clock. Supports Net Stream traffic statistics. Supports intelligent Power Supply management, supports 802.3az energy-efficient Ethernet. Supports online device status monitoring mechanism, achieving detection of key components including supervisor engine, backplane, chips, and storage. |
| Reliability | Supports Supervisor Engine Module 1+1 Redundancy Backup Supports Power Supply 1+1 Redundancy Backup Adopt Passive Backplane Design All Line Cards Support Hot Swappable Supports CPU Protection Technology Supports VRRP Supports Ethernet OAM (802.1ag and 802.3ah) Supports MAC Tracert Supports RPR Supports RRPP, ERPS Supports Graceful Restart for OSPF/BGP/IS-IS Supports DLDP Supports VCT Supports Smart-Link Supports Hot Patch |
| Environmental requirements | Temperature Range: 0°C~45°C Relative Humidity: 10%~95% (Non-condensing) |
| Power Supply | DC:–48V~–60V AC: 100V~240 |
| Physical Dimensions (Width × Height × Depth) (mm) | 436 x 175 x 420 436 x 575 x 420 |
| Fully Configured Weight (kg) | ≤27kg |
| Ordering Information | |
| Standard Controller Engine Board | |
| 0231A5M8 | LSQM1CGP24TSSA8 - H3C S7003E Switching and Routing Engine Module, 24 Gigabit Ethernet optical ports (SFP, LC) + 4 10 Gigabit Ethernet optical ports (SFP+, LC) (SA) |
| SFP Gigabit Port | |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A12T | SFP-FE-LX-SM1310-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1310/RX 1550 nm, 15 km, LC) |
| 0231A12U | SFP-FE-LX-SM1550-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1550/RX 1310 nm, 15 km, LC) |
| 0231A564 | SFP-FE-LX-SM1310-A - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A965 | SFP-FE-LX-SM1310-D - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A320 | SFP-FE-SX-MM1310-A - Optical Module—SFP 100M/155M Multimode Module (1310 nm, 2 km, LC) |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A11U | SFP-GE-LX-SM1310-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1310/RX 1490, 10 km, LC |
| 0231A11V | SFP-GE-LX-SM1490-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1490/RX 1310, 10 km, LC |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| SFP+ 10G Port | |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231A0A8 | SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A0A6 | SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231A0AK | LSWM1STK - SFP+Cable0.65m |
| 0231A0AL | LSWM2STK - SFP+Cable1.2m |
| 0231A0AM | LSWM3STK - SFP+Cable3m |
| 0231A5M6 | LSQM1CGT24TSSA8 - H3C S7003E Switching and Routing Engine Module, 24 Gigabit Ethernet Electrical Ports (RJ45) + 4 10 Gigabit Ethernet Optical Ports (SFP+, LC) (SA) |
| Enhanced Controller Engine Board | |
| 0231A6TY | LSQM1CGP24TSSC8 - H3C S7003E Switching and Routing Engine Module, 24 Gigabit Ethernet ports (SFP, LC) + 4 10 Gigabit Ethernet ports (SFP+, LC) (SA) |
| 0231A089 | SFP-FE-LH40-SM1310 - Optical Module - SFP 100M/155M Single-Mode Module - (1310nm, 40km, LC) |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI - SFPGigabitBIDI Optical Module (TX 1490/RX 1550 nm, 70 km, LC) |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC) |
| 0231A6U0 | LSQM1CGT24TSSC8 - H3C S7003E Switching and Routing Engine Module, 24-port Gigabit Ethernet electrical interfaces (RJ45) + 4-port 10 Gigabit Ethernet optical interfaces (SFP+, LC) (SC) |
| Business Module | |
| 0231A5XN | LSQM1TGS16FD8 - H3C S7000E 16-Port10GEthernetoptical interface Module(SFP+,LC)(FD) |
| 0231A0G1 | LSTM1STK - SFP+Cable5m |
| 0231A1J8 | LSTM2STK - SFP+ cable7m |
| 0231A5P5 | LSQM2GP24TSSA8 - H3C S7000E 24-Port Gigabit Ethernetoptical interface(SFP,LC)+4-Port10GEthernetoptical interface Module(SFP+,LC)(SA) |
| 0231A5P7 | LSQM2GP48SA8 - H3C S7000E 48-Port Gigabit Ethernetoptical interface Module(SFP,LC)(SA) |
| 0231A5P6 | LSQM2GT48SA8 - H3C S7000E 48-Port Gigabit Ethernetelectrical interface Module(RJ45)(SA) |
| Security License Certificate | |
| 3130A2CL | LIS-F1000G2-ACG-3Y - H3C Sec Path F1000G2,application identificationsignature database update service,3 years |
| 3130A2CM | LIS-F1000G2-AV-1Y - H3C Sec Path F1000G2,AV anti-virus security license,1 year |
| 3130A2CN | LIS-F1000G2-AV-3Y - H3C Sec Path F1000G2,AV anti-virus security license,3 years |
| 3130A2CH | LIS-F1000G2-IPS-1Y - H3C Sec Path F1000G2,IPS signature database update service,1 year |
| 3130A2CJ | LIS-F1000G2-IPS-3Y - H3C Sec Path F1000G2,IPS signature database update service,3 years |
| 3130A2CK | LIS-F1000G2-ACG-1Y - H3C Sec Path F1000G2,application identificationsignature database update service,1 year |
| 3130A2CG | LIS-F1000G2-LB - H3C Sec Path F1000G2,LBlicense certificate |
| 3130A37C | LIS-F1000G2-URL-1Y - H3C Sec Path F1000G2 URLsignature database update service license certificate,1 year |
| 3130A377 | LIS-F1000G2-URL-3Y - H3C Sec Path F1000G2 URLsignature database update service license certificate,3 years |
| 3130A3V8 | LIS-U-AV-1Y-ADE - H3C Secblade-Advance-ADE AV antivirus security license certificate,1 year |
| 3130A3VG | 3130A3VG - S7000E Switch Series |
| 3130A3W1 | LIS-U-IPS-1Y-ADE - H3C Secblade-Advance-ADE IPSsignature database update service license certificate,1 year |
| 3130A3W0 | 3130A3W0 - S7000E Switch Series |
| 3130A3VV | LIS-U-WAF-1Y-ADE - H3C Secblade-Advance-ADE WAF Feature Library Upgrade License, 1 year |
| 3130A3W7 | 3130A3W7 - S7000E Switch Series |
| Power Module | |
| 0231A79R | LSQM1AC650 - H3C PSR650A AC power Module,650W |
| 0231A91B | LSQM1AC300 - AC power Module,300W |
| Serial Cable | |
| 04042967 | CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port) |
| 0404A1EE | CAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP) |
| Product Identity | |
| Brand | H3C |
| Series | H3C S7000E Series Switch |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Switching Capacity specification for LS-7003E?
What is the IPv4Packet Forwarding Rate specification for LS-7003E?
What is the Fully Configured Weight (Kg) specification for LS-7003E?
What is the Total slot count specification for LS-7003E?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?