ITMall,Your IT Global Procurement Service Expert
H3C LS-9827-64EP
Brand H3C
N/AVerified

H3C LS-9827-64EP

Model (MPN)
0235A4U5
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock

H3C LS-9827-64EP Layer 3 Ethernet Switch Chassis. Switching Capacity: 102.4Tbps. Packet Forwarding Rate: 21000Mpps. Out-of-band Management Ethernet Port: 1 Electrical port

Key Specifications

DescriptionH3C S9827-64EP L3 Ethernet Switch Chassis
Switching Capacity102.4Tbps
Packet Forwarding Rate21000Mpps
Out-of-band Management Ethernet Port1 Electrical port
800GE OSFP800-Port64-Ports
Dimensions (Width x Depth x Height) (Unit: mm)442×760×175
Your Price
Best Value
$72,047.99
List Price: $1,029,257.00Save 93%
Availability Out of Stock
Quantity

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

H3C LS-9827-64EP Layer 3 Ethernet Switch Chassis

Specifications

Catalog Description
DescriptionH3C S9827-64EP L3 Ethernet Switch Chassis
Key Specifications
Switching Capacity102.4Tbps
Packet Forwarding Rate21000Mpps
Out-of-band Management Ethernet Port1 Electrical port
800GE OSFP800-Port64-Ports
Dimensions (Width x Depth x Height) (Unit: mm)442×760×175
Full Configuration Weight40.5kg
Product Specifications
Dimensions (Width x Depth x Height) (Unit: mm)442×760×175
Full Configuration Weight40.5kg
Serial Console port (RJ45)1
Out-of-band Management Ethernet Port1 Electrical port
USB port1 USB 2.0 interface
800GE OSFP800-Port64-Ports
Supervisor Module1 Supervisor Module
Input voltageAC
HVDC180V~320V
Power Module4 Modular Power Supplies
Fan Module8 Hot-swappable Fan Modules, Front-to-rear Airflow
Power Consumption (Static)4 AC: 237W
Power Consumption (Typical)4 AC: 743W
Operating Environment Temperature0ºC~40ºC
Operating Environment Humidity (Non-condensing)5%~95%
Switching Capacity102.4Tbps
Packet Forwarding Rate21000Mpps
Forwarding ModeSupports Store-and-forward mode
Network VirtualizationSupports BGP-EVPN and VxLAN
SDN ControllerSupports ADDC
Data Center FeaturesSupports VxLAN Mapping, Supports Service Chain, Supports RDMA Lossless Network RoCEv2, Supports Buffer Visualization, Supports DCBX, PFC, ETS, ECN, Supports iNOF, IPCC*, Supports CNP Response and CNP Retransmission, Supports Spraylink, LBN, DLB, Supports Global Load Balancing FGLB*, Supports Intelligent Traffic Model Identification, Dynamic Adjustment of AI ECN Thresholds, Supports Latency-based ECN, Achieving Precise Traffic Control, Supports PFC Deadlock Prevention
ProgrammableSupports NETCONF, Supports Python, Supports Ansible Automation Configuration
MAC Address TableSupports dynamic, static, and blackhole MAC address table entries. Supports MAC address auto-learning and aging. Supports source MAC address filtering.
VLANSupports Port-based, Protocol-based, and MAC-based VLANs. Supports Default VLAN.
Traffic MonitoringSupports s Flow/Net Stream. Supports Telemetry. Supports INT (In-band Network Telemetry). Supports Telemetry stream (Packet Event packet loss and ultra-long latency visualization). Supports RoCE cluster intelligent O&M platform. Supports gRPC high-speed data active reporting, active detection of network-wide paths, and real-time monitoring of network health status. Supports microsecond-level PFC and headroom monitoring, achieving precise visualized O&M.
ARPSupports ARP, RARP, and Gratuitous ARP. Supports Dynamic ARP Inspection. Supports ARP anti-attack. Supports ARP source suppression. Supports ARP Detection function.
IP RoutingSupports static routing and default routing. Supports IPv4 dynamic routing protocols such as RIP, OSPF, BGP, ISIS. Supports IPv6 dynamic routing protocols such as RIPng, OSPFv3, BGP4+, ISISv6. Supports equal-cost routing and policy-based routing.
IPv6 FeaturesSupports IPv6 ND (Neighbor Discovery). Supports IPv6 VxLAN over IPv4. Supports PMTU Discovery (Path MTU Discovery). Supports ICMPv6, Telnetv6, SFTPv6, SNMPv6, VRRPv3. Supports IPv6-Portal and IPv6 Tunnel.
ReliabilitySupports STP, RSTP, MSTP. Supports BPDU protection, Root protection, and Loop protection. Supports LACP. Supports DLDP. Supports Smart Link. Supports M-LAG.
QoSSupports Port transmit/receive packet rate limiting. Supports ACL, CAR, priority remarking, and queues. Supports multiple queue scheduling such as SP, WRR, WFQ, SP+WRR, SP+WFQ. Supports Layer 2~Layer 4 packet filtering. Supports flow classification based on Source MAC, Destination MAC, Source IP (IPv4/IPv6) address, Destination IP (IPv4/IPv6) address, Port, Protocol, VLAN. Supports traffic shaping. Supports congestion avoidance mechanisms such as WRED and tail drop.
MirroringSupports traffic mirroring. Supports N:4-Port mirroring. Supports local and remote Port mirroring (ERSPAN).
Security FeaturesSupports user level management and password protection, supports IP, MAC, Port, VLAN combination binding, supports prevention of DOS, ARP, ICMP, and other attacks, supports IP Source Guard, Port isolation, supports HTTPS, SSL, supports MOD, supports CPU attack prevention function, supports ARP attack prevention function, supports automatic defense (ARP/DHCP/ICMP, etc. attack defense)
Management and MaintenanceSupports Telemetry visualization function, supports cache micro-burst detection, supports Zero Configuration Auto-config and Configuration rollback, supports Command Line Interface (CLI) Configuration, supports Configuration via Console, Telnet, SSH, etc., supports RMON (Remote Monitoring), supports SNMP v1/v2c/v3, supports Network Management System, supports NETCONF and Python, supports system logs and user operation logs, supports level-based alarms, supports Power Supply, Fan, temperature alarm function, supports NTP network time protocol, supports Jumbo Frame 9216 bytes, supports Ping, Tracert, etc. debug information output, supports FTP, TFTP, USB, etc. methods for uploading and downloading files, supports XModem protocol loading upgrade
Light Source Module16 Remotely Pluggable Optical Modules
Ordering Information
Main Control Engine Board
0231AMNQLSWM1SUPX1 - H3C S9800 Master Control Engine Module
Fan Options
0231AMNRFAN-80B-1-D - Fan Module(Fan Panel Side Air Outlet)
Power Module
0231AMP2PSR2000-12A-S - 2000W AC System Power Module (Power Supply Side Outlet)
Power Supply Cable
0404A0K4CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard
0404A27MCAB-AC-0.6m-CHN-51005 - PDUPower Supply Cable-0.6m-3*0.75mm^2-Black-(C14 Connector(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard
0404A27LCAB-AC-1.0m-CHN-51004 - PDUPower Supply Cable-1.0m-3*0.75mm^2-Black-(C14 Connector(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard
0404A1W1CAB-AC PWR-3m-CHN-50905 - PDU Power Supply Cable - 3.0 m - 3 × 1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - National Standard
0404A0U5CAB-HVDC PWR-2m-PDU - PDU Power Supply Cable - 2.0 m - 3 × 1.0 mm² - Yellow 121C - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - Chinese Standard
0404A02WCAB-C13-C14-1.0m - PDU Power Supply Cable - 1.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - GB Standard
0404A098CAB-C13-C14-1.5m - PDU Power Supply Cable - 1.5 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250 V 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - National Standard
0404A02XCAB-C13-C14-2.0m - PDU Power Supply Cable - 2.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male, 250 V, 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female, 250 V, 10 A) - Chinese National Standard
0404A0W5CAB-PDU PWR-5m-C13/C14 - PDU Power Supply Cable - 5.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250 V 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - Chinese Standard
0404A06QCAB-AC Pwr CHI-1.8m - Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard
04042697CAB-AC Pwr CHI-10m - Wall Plug AC power Cord-10m-3*1.0mm^2-Black-(GB1002 Plug(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard
04042698CAB-AC Pwr CHI-15m - Wall Plug AC power Cord-15m-3*1.0mm^2-Black-(GB1002 Plug(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard
04041104Cable-Power-AC - AC power Cord for Wall Outlet - 3.0 m - 3 × 1.0 mm² - Black - (GB1002 Plug (3P) Straight Male 250 V 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250 V 10 A) - Chinese National Standard
0404A1GYCab-PDU-C14-3m-C13-CHN - PDU Power Supply Cable - 3.0 m - 3 × 1.0 mm² - Black - (C14 Connector (3P) Straight Male, 250 V, 10 A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female, 250 V, 10 A) - Chinese National Standard
0404A13VCable-Power-AC-CHI-5m - Wall Plug AC power cord-5.0m-3*1.0mm^2-Black-(GB1002 Plug(3P) Straight Male 250V10A)-(227 IEC 53(RVV))-(C13 Connector(3P) Straight Female 250V10A)-National Standard
0404A19E0404A19E - H3C S9827 Switch Series
0404A0GJCAB-HVDC-250V10A-3m-Y - Wall-mounted AC power cord—3.0 m—3 × 1.0 mm²—Yellow 121C—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard
0404A0GFCAB-HVDC-10A-PDU-3m-Y - PDU Power Supply Cable - 3.0 m - 3 × 1.0 mm² - Yellow 121C - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV)) - (C13 Connector (3P) Straight Female 250V 10A) - National Standard
Serial Cable
04042967CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port)
0404A1EECAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP)
Rack Rail
0231A2VLLSVM1BSR10 - H3C S9810 Installation Rack Rail Accessory-630mm~900mm
Product Identity
BrandH3C
SeriesH3C S9827 Series Switch

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

FAQ

What is the Switching capacity specification for LS-9827-64EP?
LS-9827-64EP lists Switching capacity as 102.4Tbps. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Serial console port specification for LS-9827-64EP?
LS-9827-64EP lists Serial console port as 1. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Dimensions (W × D × H) specification for LS-9827-64EP?
LS-9827-64EP lists Dimensions (W × D × H) as 442×760×175 mm. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Weight (Full loaded) specification for LS-9827-64EP?
LS-9827-64EP lists Weight (Full loaded) as 40.5kg. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?