| Key Specifications |
|---|
| Jumbo Frame | Supports maximum frame length of 13312 |
| DHCP | DHCPv4/v6 ClientDHCP Snooping、DHCPv6 SnoopingDHCPv4/v6 RelayDHCPv4/v6 ServerDHCP Snooping option82/DHCP Relay option82 |
| Ports | 48*100/1000 SFP PoE++ Ports, 4*1G/2 |
| MPLS | Support MPLS MCE |
| Model | LS-FS5300-48US4X2Q-EI |
| Product Code | 9801A4J5 |
| Product Specifications |
|---|
| Port aggregation | Supports Port Aggregation, Supports Static Aggregation, Supports Dynamic Aggregation, Supports Cross-Device Link Aggregation, M-LAG |
| Port Features | Supports IEEE802.3x flow control (full-duplex) Supports storm suppression based on port rate percentage Supports storm suppression based on PPS Supports storm suppression based on bps |
| Jumbo Frame | Supports maximum frame length of 13312 |
| MAC Address Table | Supports static, dynamic, and blackhole MAC address modes. Supports source MAC address filtering. Supports setting the maximum number of learned Port MAC addresses. |
| VLAN | Supports 802.1Q VLAN, supports 4K VLAN, supports Port-based VLAN, supports QinQ and flexible QinQ, supports Guest VLAN, supports STP, RSTP, MSTP, PVST, supports MVRP, supports Voice VLAN, supports Policy VLAN, supports IP Subnet-based VLAN, supports Protocol-based VLAN, supports MAC-based VLAN |
| DHCP | DHCPv4/v6 ClientDHCP Snooping、DHCPv6 SnoopingDHCPv4/v6 RelayDHCPv4/v6 ServerDHCP Snooping option82/DHCP Relay option82 |
| IRF2 Intelligent Elastic Architecture | Supports IRF2 Intelligent Elastic Architecture Supports Distributed Device Management, Distributed Link Aggregation, Distributed Elastic Routing Supports Stacking via Standard Ethernet Interface etc. Supports Local Stacking and Remote Stacking |
| IP Routing | Supports IPv4/IPv6 static routing Supports IPv4/IPv6 dual stack Supports RIPv1/v2, RIPng Supports OSPFv1/v2, OSPFv3 Supports BGP4, BGP4+ for IPv6 Supports IS-IS, IS-IS V6 Supports Equivalent Routing, Policy Routing Supports VRRP/VRRPv3 Supports OSPF Multi-Process, MD5 encryption authentication, STUB/NSSA area support route COST settings, support inter-area route filtering |
| IPv6 | Supports IPv4/IPv6 dual-stack protocols Supports ND (Neighbor Discovery)Supports ND Snooping Supports PMTUSupports IPv6-Ping, IPv6-Tracert, IPv6-Telnet, IPv6-TFTP, IPv6-ICMP, IPv6-DNS, IPv6-FTP |
| Mirroring | Supports flow Mirroring. Supports N:1-Port Mirroring. Supports local and remote Port Mirroring. Supports ERSPAN. |
| ACL\QoS | Supports L2 (Layer 2)~L4 (Layer 4) packet filtering, providing flow classification based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, TCP/UDP port number, and VLANs Supports Time Range ACLs Supports inbound and outbound bi-directional ACL policies Supports issuing ACLs based on VLANs Supports limiting the rate of incoming messages and the rate of outgoing messages on ports Supports message redirection Supports message redirection Supporting the rate of receiving messages and the rate of sending messages on ports Supports message redirection. Supports bi-directional ACL policy in both inbound and outbound directions Supports VLAN-based downstream ACLs Supports limiting the rate of incoming and outgoing messages on ports Supports message redirection Supports 802.1p and DSCP priority re-tagging of messages Supports CAR (Committed Access Rate) function Supports flexible queue scheduling algorithms, which can be set up based on ports and queues at the same time Support for SP, WFQ, SP+WFQ three modes support for network slicing |
| MPLS | Support MPLS MCE |
| Security Features | Supports user level management and password protection Supports 802.1X authentication/centralized MAC address authentication Supports Portal authentication Supports Guest VLANSupports RADIUS authentication Supports HWTACACS+ authentication Supports SSH 2.0Supports Port isolation, Port security, Sticky MACSupports binding of IP, MAC, Port, VLAN in combination Supports blacklist and whitelist Supports MFFSupports EADSupports SAVI, SAVA, ensuring security in IPv6 environment Supports DHCP Snooping, DHCPv6 Snooping, preventing rogue DHCP servers Supports dynamic ARP inspection (Dynamic ARP Inspection, DAI), preventing man-in-the-middle attacks and ARP denial of service Supports anti-DOS attack Supports anti-ARP attack Supports anti-ICMP attack Supports CPU protection Supports CPU anti-attack Supports BPDU guard, Root guard Supports uRPF (unicast reverse path forwarding), preventing IP source address spoofing, preventing viruses and attacks Supports binding of IP/Port/MACSupports plaintext and MD5 ciphertext authentication of OSPF, RIPv2 packets Supports PKI (Public Key Infrastructure, public key infrastructure) |
| Management and Maintenance | Supports hotfix function, can be online for patch upgrade Supports XModem/FTP/TFTP load upgrade Supports Command Line Interface (CLI), Telnet, Console port for configuration Supports netcool network management platform Supports SNMPv1/v2/v3, RMON (Remote Monitoring) Supports hardware BFD For VRRP/IS-IS/BGP/RIP/OSPF/static routing, the minimum detection interval of 3ms support iMC Intelligent Management Center support Syslog, system logs, hierarchical alarms, debugging information output support NTP support for power alarms, fan, temperature alarms support Ping, Tracert support VCT (Virtual Cable) cable testing function support Dual Channel Cable (DCC), DCC, DCC, DCC, DCC, DCC, DCC, DCC, DCC, and DCC. Test) cable detection function supports DLDP (Device Link Detection Protocol) unidirectional link detection protocol supports LLDP supports Y.1731 supports Ethernet OAM supports Telemetry visualization supports NETCONF network management protocol supports Python script management operation and maintenance supports Loopback-detection detection Port loopback detection support Net Stream function, traffic analysis sampling ratio of 1:1 support SFLOW support USB for file upload and download, support USB open support ID indicator, you can locate the location of the device through the indicator flashes |
| Green Energy Saving | Port automatic power down function, Port scheduled power down function (Schedule job), EEE (802.3az) energy saving standard support |
| Catalog Description |
|---|
| Description | H3C FS5300-48US4X2Q-EI L3 Ethernet Switch with 48*100/1000 SFP PoE++ Ports, 4*1G/2.5G/10G SFP Plus Ports, and 2*40G QSFP Plus Ports, Without Power Supplies |
| Ordering Information |
|---|
| Base Configuration | |
| 9801A4J5 | LS-FS5300-48US4X2Q-EI |
| SFP Gigabit Optical Port | |
| 02312173 | SFP-GE-LH80-SM1550; Single-mode SFP optical module (1550 nm, 80 km, LC); Type: SFP Gigabit Optical Port |
| 0231A12U | SFP-FE-LX-SM1550-BIDI; SFP Fast Ethernet BIDI Optical Module (TX 1550 nm/RX 1310 nm, 15 km, LC); Type: SFP Gigabit Optical Port |
| 0231A12T | SFP-FE-LX-SM1310-BIDI; SFP Fast Ethernet BIDI Optical Module (TX 1310 nm/RX 1550 nm, 15 km, LC); Type: SFP Gigabit Optical Port |
| 0231A564 | SFP-FE-LX-SM1310-A; Single-mode SFP 100M/155M optical module (1310 nm, 15 km, LC); Type: SFP Gigabit Optical Port |
| 0231A965 | SFP-FE-LX-SM1310-D; Single-mode SFP 100M/155M optical module (1310 nm, 15 km, LC); Type: SFP Gigabit Optical Port |
| 0231A320 | SFP-FE-SX-MM1310-A; Optical Module-SFP 100M/155M-Multimode Module (1310nm, 2km, LC); Type: SFP Gigabit Optical Port |
| 0231A089 | SFP-FE-LH40-SM1310; Single-mode SFP 100M/155M optical module (1310 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 0231A090 | SFP-FE-LH80-SM1550; Optical Module-SFP 100M/155M Single-mode Long-Reach Module (1550nm, 80km, LC); Type: SFP Gigabit Optical Port |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI; SFP GigabitBIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI; SFP GigabitBIDI Optical Module (TX 1490 nm/RX 1550 nm, 70 km, LC); Type: SFP Gigabit Optical Port |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI; SFP GigabitBIDI Optical Module (TX 1550 nm/RX 1310 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI; SFP GigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC); Type: SFP Gigabit Optical Port |
| 0231A54T | SFP-STACK-Kit; Type: SFP Gigabit Optical Port |
| 0231A563 | SFP-GE-LX-SM1310-A; Single-mode SFP GE optical module (1310 nm, 10 km, LC); Type: SFP Gigabit Optical Port |
| 0231A962 | SFP-GE-LX-SM1310-D; Single-mode SFP GE optical module (1310 nm, 10 km, LC); Type: SFP Gigabit Optical Port |
| 02312170 | SFP-GE-LH40-SM1310; Single-mode SFP GE optical module (1310 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 0231A963 | SFP-GE-LH40-SM1310-D; Single-mode SFP GE optical module (1310 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 02312172 | SFP-GE-LH40-SM1550; Single-mode SFP optical module (1550 nm, 40 km, LC); Type: SFP Gigabit Optical Port |
| 0231A964 | SFP-GE-LH80-SM1550-D; Single-mode SFP optical module (1550 nm, 80 km, LC); Type: SFP Gigabit Optical Port |
| 0231A562 | SFP-GE-SX-MM850-A; Multi-mode SFP-GE optical module (850 nm, 0.55 km, LC); Type: SFP Gigabit Optical Port |
| 0231A961 | SFP-GE-SX-MM850-D; Multi-mode SFP-GE optical module (850 nm, 0.55 km, LC); Type: SFP Gigabit Optical Port |
| 0231A11U | SFP-GE-LX-SM1310-BIDI; Optical Module - SFP Gigabit BIDI Optical Module - TX1310/RX1490, 10 km, LC; Type: SFP Gigabit Optical Port |
| 0231A11V | SFP-GE-LX-SM1490-BIDI; Optical Module - SFP Gigabit BIDI Optical Module - TX1490/RX1310, 10 km, LC; Type: SFP Gigabit Optical Port |
| 0231A085 | SFP-GE-T; SFP GE Electrical Port Module (100m, RJ45); Type: SFP Gigabit Optical Port |
| 0231A960 | SFP-GE-T-D; SFP GE Electrical Port Module (100m, RJ45); Type: SFP Gigabit Optical Port |
| 0231AJXK | SFP-2.5G-LX10-SM1310-DR-I; SFP 2.5G/1G Single-Mode Operating-Temperature Optical Module (1310 nm, 10 km, LC); Type: SFP Gigabit Optical Port |
| SFP/SFP+10G Optical Port | |
| 0231A9X2 | SFP-XG-CPRI-IR-SM1310; SFP+ 10G CPRI Optical Module (-40°C to 85°C, 1310nm, 1.4km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A9X3 | SFP-XG-CPRI-LR-SM1310; SFP+ 10G CPRI Optical Module (-40°C to 85°C, 1310nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231AA9S | SFP-XG-LH80-Tunable-OPN; 10G SFP+Optical Module (single-mode, Tunable, 80km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A3TA | SFP-XG-D-AOC-10M; SFP+ to SFP+10m AOC; Type: SFP/SFP+10G Optical Port |
| 0231A3TB | SFP-XG-D-AOC-20M; SFP+ to SFP+20m AOC; Type: SFP/SFP+10G Optical Port |
| 0231A3T9 | SFP-XG-D-AOC-7M; SFP+ to SFP+7m AOC; Type: SFP/SFP+10G Optical Port |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI; SFP+ 10GBIDI Optical Module (TX 1270nm/RX 1330nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI; SFP+ 10GBIDI Optical Module (TX 1270nm/RX 1330nm, 40km, LC); Type: SFP/SFP+10G Optical Port |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI; SFP+ 10GBIDI Optical Module (TX 1330nm/RX 1270nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI; SFP+ 10GBIDI Optical Module (TX 1330nm/RX 1270nm, 40km, LC); Type: SFP/SFP+10G Optical Port |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI; SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC); Type: SFP/SFP+10G Optical Port |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI; SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A0A8 | SFP-XG-LX-SM1310; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A2L3 | SFP-XG-LX-SM1310-E; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A1RQ | SFP-XG-LX-SM1310-D; SFP+ 10G Module (1310nm, 10km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A0SP | SFP-XG-LH40-SM1550; SFP+ 10G Module (1550nm, 40km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A1RR | SFP-XG-LH40-SM1550-D; SFP+ 10G Module (1550nm, 40km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A2T6 | SFP-XG-LH80-SM1550-D; SFP+ 10G Module (1550nm, 80km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A1PA | SFP-XG-LH80-SM1550; SFP+ 10G Module (1550nm, 80km, LC); Type: SFP/SFP+10G Optical Port |
| 0231A0A6 | SFP-XG-SX-MM850-A; SFP+ 10G Module (850nm, 300m, LC); Type: SFP/SFP+10G Optical Port |
| 0231A1RP | SFP-XG-SX-MM850-D; SFP+ 10G Module (850nm, 300m, LC); Type: SFP/SFP+10G Optical Port |
| 0231A0AK | LSWM1STK; SFP+Cable0.65m; Type: SFP/SFP+10G Optical Port |
| 0231A0AL | LSWM2STK; SFP+Cable1.2m; Type: SFP/SFP+10G Optical Port |
| 0231A0AM | LSWM3STK; SFP+Cable3m; Type: SFP/SFP+10G Optical Port |
| 0231A0G1 | LSTM1STK; SFP+Cable5m; Type: SFP/SFP+10G Optical Port |
| QSFP+ Port | |
| 0231A1LS | LSWM1QSTK0; 40G QSFP+ 1m Cable; Type: QSFP+ Port |
| 0231A1LT | LSWM1QSTK1; 40G QSFP+ 3m Cable; Type: QSFP+ Port |
| 0231A1LU | LSWM1QSTK2; 40G QSFP+ 5m Cable; Type: QSFP+ Port |
| 0231A9CT | QSFP-40G-D-AOC-3M; 40G QSFP+ to 40G QSFP+ 3m Active Optical Cable; Type: QSFP+ Port |
| 0231A3U4 | QSFP-40G-D-AOC-10M; 40G QSFP+ to 40G QSFP+10m AOC; Type: QSFP+ Port |
| 0231A3U5 | QSFP-40G-D-AOC-20M; 40G QSFP+ to 40G QSFP+20m AOC; Type: QSFP+ Port |
| 0231A3U3 | QSFP-40G-D-AOC-7M; 40G QSFP+ to 40G QSFP+7m AOC; Type: QSFP+ Port |
| 0231A2E4 | QSFP-40G-LR4-WDM1300; QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC); Type: QSFP+ Port |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850; QSFP+ 40G BIDI Optical Module (850nm, 100m, SR); Type: QSFP+ Port |
| 0231A4PB | QSFP-40G-LR4L-WDM1300; QSFP+ 40G Optical Module (1310nm, 2km, LR4L, LC); Type: QSFP+ Port |
| 0231A4UG | QSFP-40G-ER4-WDM1300; QSFP+ 40G Optical Module (1310nm, 40km, ER4, LC); Type: QSFP+ Port |
| 0231A2NF | QSFP-40G-SR4-MM850; Type: QSFP+ Port |
| 0231A2KL | QSFP-40G-CSR4-MM850; Type: QSFP+ Port |
| Power Supply Module | |
| 9803A05Q | PSR1600-54A-B; H3C-PSR1600-54A-B-1600W/AC PoE Power Supply Module; Type: Power Supply Module |
| 9803A05N | PSR600-54A-B; H3C-PSR600-54A-B-600W/AC PoE Power Supply Module; Type: Power Supply Module |
| 9803A05P | PSR920-54A-B; H3C-PSR920-54A-B-920W/AC PoE Power Supply Module; Type: Power Supply Module |
| Hybrid Optical-Electrical Cable | |
| 2505A006 | CAB-17AWG-500-LSZH; Symmetrical Twisted Pair Cable—Optical-Electrical Hybrid Cable—33 mm—17 AWG—2C+2C—500 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A007 | CAB-21AWG-200-PVC; Symmetrical Twisted Pair Cable—Optical-Electrical Hybrid Cable—13 mm—21 AWG—2C+2C—200 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A008 | Symmetrical Twisted Pair Cable—Optical-Electrical Hybrid Cable—33 mm—17 AWG—2C+2C—200 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A009 | CAB-17AWG-100-PVC; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 33 mm - 17 AWG - 2C+2C - 100 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A00A | CAB-21AWG-100-LSZH; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 13 mm - 21 AWG - 2C+2C - 100 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A00B | CAB-17AWG-100-LSZH; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 33 mm - 17 AWG - 2C+2C - 100 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A00C | CAB-17AWG-200-LSZH; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 33 mm - 17 AWG - 2C+2C - 200 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A00D | CAB-21AWG-100-PVC; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 13 mm - 21 AWG - 2C+2C - 100 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A00E | CAB-21AWG-500-PVC; Symmetrical Twisted Pair Cable—Optical-Electrical Hybrid Cable—13 mm—21 AWG—2C+2C—500 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A00F | Symmetrical Twisted Pair Cable—Optical-Electrical Hybrid Cable—33 mm—17 AWG—2C+2C—500 meters (PVC); Type: Hybrid Optical-Electrical Cable |
| 2505A00G | CAB-21AWG-200-LSZH; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 13 mm - 21 AWG - 2C+2C - 200 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A00H | CAB-21AWG-500-LSZH; Symmetrical Twisted Pair Cable - Fiber-Optic Hybrid Cable - 13 mm - 21 AWG - 2C+2C - 500 meters (LSZH); Type: Hybrid Optical-Electrical Cable |
| 2505A00J | HYBRID CABLE-200-0.5; 200-meter hybrid optical-electrical cable; Type: Hybrid Optical-Electrical Cable |
| 2505A00K | HYBRID CABLE-100-0.5; 100-meter fiber-optic hybrid cable; Type: Hybrid Optical-Electrical Cable |
| 2505A00L | HYBRID CABLE-500-0.5; 500-meter hybrid optical-electrical cable; Type: Hybrid Optical-Electrical Cable |
| 2505A00M | HCAB-GDJV-20AWG-200m-2F; GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00N | HCAB-GDJV-20AWG-500m-2F; GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00P | HCAB-GDJV-20AWG-100m-2F; GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00Q | HCAB-GDJV-21AWG-200-2F; GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00R | HCAB-GDJV-21AWG-500m-2F; GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00S | HCAB-GDJV-21AWG-100-2F; GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00T | HCAB-GDJV-17AWG-100m-2F; GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00U | HCAB-GDJV-17AWG-200m-2F; GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00V | HCAB-GDJV-17AWG-500m-2F; GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00W | HCAB-GDJH-21AWG-500m-2F; GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00X | HCAB-GDJH-21AWG-200m-2F; GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A00Y | HCAB-GDJH-21AWG-100m-2F; GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.7 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A010 | HCAB-GDJH-20AWG-100m-2F; GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A011 | HCAB-GDJH-20AWG-200m-2F; GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A012 | HCAB-GDJH-20AWG-500m-2F; GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.9 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A013 | HCAB-GDJH-17AWG-500m-2F; GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A014 | HCAB-GDJH-17AWG-100m-2F; GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| 2505A015 | HCAB-GDJH-17AWG-200m-2F; GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 6.2 mm); Type: Hybrid Optical-Electrical Cable |
| Cable Management Box | |
| 9821A0KA | H3C GC-KDS24-HUS1-B; Optical-Electrical Hybrid switch Cable Management Box (1U, Supports 48 Cables, for FS5300 Series); Type: Cable Management Box |
| Ear Hook | |
| 2150A03X | LS-FL-LE-1U; 1U Compatible Ears - 1U Chassis; Type: Ear Hook |
| Heat-Shrink Tubing | |
| 9904A0KE | H3C GC-SD-B0; Custom Fiber Fusion Splicing Heat-Shrink Sleeves for Optoelectronic Hybrid Solutions (Inner Diameter 2.3 mm, 50 pieces per pack); Type: Heat-Shrink Tubing |
| Cold-pressed intermediate terminal | |
| 9904A0KD | H3C GC-BNYF1.25; Cold-Pressed Intermediate Terminals (BNYF1.25, 100 pcs included); Type: Cold-pressed intermediate terminal |
| Port and Cable Configuration | |
| 04042967 | CAB-CON-1.8m; Configuration Serial Cable—1.8 m (DB9 Female to 8-pin Ethernet Port); Type: Port and Cable Configuration |
| 0404A1EE | CAB-Console-1.8m-W31R; Configuration Port Cable-1.8m (RJ45P) (UL2725(3C28AWG)) (USB AP); Type: Port and Cable Configuration |
| Product Identity |
|---|
| Brand | H3C |
| Series | H3C S51xxSeries Switches |