H3C LS-FS6300V2-48UX2Q4C-EI Layer 3 Ethernet Switch Chassis, supports 48 1G/2.5G/10G SFP+ PoE++ ports, supports 2 40G QSFP+ ports, supports 4 100G QSFP28 ports, no power supply

H3C LS-FS6300V2-48UX2Q4C-EI
H3C LS-FS6300V2-48UX2Q4C-EI Layer 3 Ethernet Switch Chassis, supports 48 1G/2.5G/10G SFP+ PoE++ ports, supports 2 40G QSFP+ ports, supports 4 100G QSFP28 ports, no power supply. Switching Capacity: 2.56Tbps/25.6Tbps. Packet Forwarding Rate: 1620Mpps. Management Ethernet port: 10/100/1000Base-T Electrical Port: 1
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C FS6300V2-48UX2Q4C-EI L3 Ethernet Switch Chassis, supports 48 1G/2.5G/10G SFP Plus PoE++ ports, supports 2 40G QSFP Plus ports, supports 4 100G QSFP28 ports, no power supply |
| Key Specifications | |
| Switching Capacity | 2.56Tbps/25.6Tbps |
| Packet Forwarding Rate | 1620Mpps |
| Management Ethernet port | 10/100/1000Base-T Electrical Port: 1 |
| 1/2.5/10GE SFP+ | 48 ports |
| 40GE QSFP+ | 2 ports |
| 40/100GE QSFP28 | 4 ports |
| Product Specifications | |
| Specification | FS6300V2-48UX2Q4C-EI |
| Switching Capacity | 2.56Tbps/25.6Tbps |
| Packet Forwarding Rate | 1620Mpps |
| Dimensions (Width x Depth x Height) (Unit: mm) | 440×400×43.6 |
| Weight | ≤8kg |
| Console Port | 1 |
| Management Ethernet port | 10/100/1000Base-T Electrical Port: 1 |
| USB port | 1 |
| 1/2.5/10GE SFP+ | 48 ports |
| 40GE QSFP+ | 2 ports |
| 40/100GE QSFP28 | 4 ports |
| Power Supply | Dual Modular Power Supply |
| Fan | Triple Modular Fans |
| PoE | Supports PoE(802.3af)/PoE+(802.3at)/PoE++(802.3bt) with maximum 100W output power per port |
| Static Power Consumption | Single AC: 101W Dual AC: 111W |
| Typical power consumption | Single AC: 133W Dual AC: 146W |
| Full Load Power Consumption | Single AC: 1698W (POE: 1400W) Dual AC: 3213W (POE: 2800W) |
| Input voltage | AC: Rated Voltage Range: 100~240V AC: 50/60Hz |
| Whole machine leakage current | Meet UL62368-1/EN62368 -1/IEC62368 -1/UL60950-1/IEC60950-1/GB4943.1 standard |
| Operating Environment Temperature | -5ºC~45ºC |
| Operating Ambient Relative Humidity (Non-condensing) | 5%~95% |
| Characteristics | Characterization |
| Port aggregation | Support Port Aggregation Support Static Aggregation Support Dynamic Aggregation Support 10GE Port Aggregation Support 40GE Port Aggregation Support 100GE Port Aggregation Support Cross-Device Link Aggregation M-LAG |
| Port Features | Supports IEEE802.3x flow control (full-duplex) Supports storm suppression based on port rate percentage Supports storm suppression based on PPS Supports storm suppression based on bps |
| Jumbo Frame | Supports maximum frame length of 13312 |
| MAC Address Table | Supports static, dynamic, and blackhole MAC address modes. Supports source MAC address filtering. Supports setting the maximum number of learned Port MAC addresses. |
| VLAN | Supports 802.1Q VLAN, supports 4K VLAN, supports Port-based VLAN, supports QinQ and flexible QinQ, supports Guest VLAN, supports STP, RSTP, MSTP, PVST, supports MVRP, supports Voice VLAN, supports Policy VLAN, supports IP Subnet-based VLAN, supports Protocol-based VLAN, supports MAC-based VLAN |
| Layer 2 Ring Protocol | Supports STP/RSTP/MSTP/PVST protocols. Supports STP Root Protection. Supports BPDU Protection. Supports G.8032 Ethernet Ring Protection Switching protocol (ERPS), with switching time ≤50ms, compatible with other products supporting this protocol. Supports Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection for primary/secondary links. |
| DHCP | DHCPv4/v6 ClientDHCP Snooping、DHCPv6 SnoopingDHCPv4/v6 RelayDHCPv4/v6 ServerDHCP Snooping option82/DHCP Relay option82 |
| IRF2 Intelligent Elastic Architecture | Supports IRF2 Intelligent Elastic Architecture Supports Distributed Device Management, Distributed Link Aggregation, Distributed Elastic Routing Supports Stacking via Standard Ethernet Interface etc. Supports Local Stacking and Remote Stacking |
| IP Routing | Supports IPv4/IPv6 static routing Supports IPv4/IPv6 dual stack Supports RIPv1/v2, RIPng Supports OSPFv1/v2, OSPFv3 Supports BGP4, BGP4+ for IPv6 Supports IS-IS, IS-IS V6 Supports Equivalent Routing, Policy Routing Supports VRRP/VRRPv3 Supports OSPF Multi-Process, MD5 encryption authentication, STUB/NSSA area support route COST settings, support inter-area route filtering |
| IPv6 | Supports IPv4/IPv6 dual-stack protocols Supports ND (Neighbor Discovery)Supports ND Snooping Supports PMTUSupports IPv6-Ping, IPv6-Tracert, IPv6-Telnet, IPv6-TFTP, IPv6-ICMP, IPv6-DNS, IPv6-FTP |
| Multicast | Supports IGMP Snooping v1/v2/v3 and rapid leave mechanism, MLD Snooping v1/v2, PIM Snooping, MLD Proxy, multicast VLAN, multicast load balancing across bundled ports, port-based multicast traffic statistics, controlled multicast, IGMP v1/v2/v3, MLD v1/v2, PIM-DM, PIM-SM, PIM-SSM, MSDP, MSDP for IPv6, MBGP, MBGP for IPv6 |
| Mirroring | Supports flow Mirroring. Supports N:1-Port Mirroring. Supports local and remote Port Mirroring. Supports ERSPAN. |
| ACL\QoS | Supports L2 (Layer 2) to L4 (Layer 4) packet filtering functions, providing traffic classification based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, TCP/UDP Port number, VLAN, supports Time Range ACL, bidirectional ACL policies for inbound and outbound directions, supports ACL deployment based on VLAN, supports rate limiting for received and sent packets on Port, supports packet redirection, supports 802.1p and DSCP priority remarking, supports CAR (Committed Access Rate) function, supports flexible queue scheduling algorithms, can be configured simultaneously based on Port and queue, supports SP, WFQ, and SP+WFQ three modes |
| MPLS | Support MPLS MCE |
| Security Features | Supports user level management and password protection Supports 802.1X authentication/centralized MAC address authentication Supports Portal authentication Supports Guest VLANSupports RADIUS authentication Supports HWTACACS+ authentication Supports SSH 2.0Supports Port isolation, Port security, Sticky MACSupports binding of IP, MAC, Port, VLAN in combination Supports blacklist and whitelist Supports MFFSupports EADSupports SAVI, SAVA, ensuring security in IPv6 environment Supports DHCP Snooping, DHCPv6 Snooping, preventing rogue DHCP servers Supports dynamic ARP inspection (Dynamic ARP Inspection, DAI), preventing man-in-the-middle attacks and ARP denial of service Supports anti-DOS attack Supports anti-ARP attack Supports anti-ICMP attack Supports CPU protection Supports CPU anti-attack Supports BPDU guard, Root guard Supports uRPF (unicast reverse path forwarding), preventing IP source address spoofing, preventing viruses and attacks Supports binding of IP/Port/MACSupports plaintext and MD5 ciphertext authentication of OSPF, RIPv2 packets Supports PKI (Public Key Infrastructure, public key infrastructure) |
| Management and Maintenance | Supports hotfix function, can be online for patch upgrade Supports XModem/FTP/TFTP load upgrade Supports Command Line Interface (CLI), Telnet, Console port for configuration Supports netcool network management platform Supports SNMPv1/v2/v3, RMON (Remote Monitoring) Supports hardware BFD For VRRP/IS-IS/BGP/RIP/OSPF/static routing, the minimum detection interval of 3ms support iMC Intelligent Management Center support Syslog, system logs, hierarchical alarms, debugging information output support NTP support for power alarms, fan, temperature alarms support Ping, Tracert support VCT (Virtual Cable) cable testing function support Dual Channel Cable (DCC), DCC, DCC, DCC, DCC, DCC, DCC, DCC, DCC, and DCC. Support VCT (Virtual Cable Test) cable detection function support DLDP (Device Link Detection Protocol) unidirectional link detection protocol support LLDP support Y.1731 support Ethernet OAM support Telemetry visualization support NETCONF network management protocol support Python script management operation and maintenance support public cloud management support Loopback-detection port loopback detection support SFLOW support USB for file upload and download, support USB open bureau |
| Green Energy Saving | Port automatic power down function, Port scheduled power down function (Schedule job), EEE (802.3az) energy saving standard support |
| Ordering Information | |
| SFP/SFP+10GOptical Port | |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI - SFP Gigabit BIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC) |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI - SFPGigabitBIDI Optical Module (TX 1490/RX 1550 nm, 70 km, LC) |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1310 nm, 40 km, LC) |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC) |
| 0231ALXS | SFP-GE-LX-SM1310-F - SFPGigabit All-Optical 3.0 Optical Module (1310nm, 10km, SM, LC) |
| 0231A54T | SFP-STACK-Kit - SFP Stacking Cable—(150 cm, includes stacking module) |
| 0231ADWF | SFP-GE-LH20-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,20km,LC) |
| 0231ADWE | SFP-GE-LH40-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,40km,LC) |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231AH26 | SFP-GE-LX-SM1310-BIDI-I - Optical Module-SFPGigabitBIDI Optical Module(-40℃~85℃,TX1310/RX1490,10km,LC) |
| 0231AH28 | SFP-GE-LX-SM1490-BIDI-I - Optical Module-SFPGigabitBIDI Optical Module(-40℃~85℃,TX1490/RX1310,10km,LC) |
| 0231A11U | SFP-GE-LX-SM1310-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1310/RX 1490, 10 km, LC |
| 0231A11V | SFP-GE-LX-SM1490-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1490/RX 1310, 10 km, LC |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| 0231AJXK | SFP-2.5G-LX10-SM1310-DR-I - SFP 2.5G/1G Single-Mode Industrial-Temperature Optical Module (1310 nm, 10 km, LC) |
| 0231ALXV | SFP-2.5G-LX10-SM1310-DR-I-F - SFP 2.5G/1G All-Optical 3.0 Optical Module(-40°C~85°C,1310nm,10km,SM,LC) |
| 0231AKBE | SFP-XG-D-AOC-20M-H - SFP+ to SFP+ 20m Active Fiber Cable |
| 0231A3TA | SFP-XG-D-AOC-10M - SFP+ to SFP+10m AOC |
| 0231A3TB | SFP-XG-D-AOC-20M - SFP+ to SFP+20m AOC |
| 0231A3T9 | SFP-XG-D-AOC-7M - SFP+ to SFP+7m AOC |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231AKBC | SFP-XG-SX-MM850-H - SFP+ 10G Optical Module(850nm,300m,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A0A8 | SFP-XG-LX-SM1310 - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A0A6 | SFP-XG-SX-MM850-A - SFP+ 10GModule(850nm,300m,LC) |
| 0231ALXU | SFP-XG-LX-SM1310-F - SFP+ All-Optical 3.010G Optical Module(1310nm,10km,SM,LC) |
| 0231A0AK | LSWM1STK - SFP+Cable0.65m |
| 0231A0AL | LSWM2STK - SFP+Cable1.2m |
| 0231A0AM | LSWM3STK - SFP+Cable3m |
| 0231A0G1 | LSTM1STK - SFP+Cable5m |
| QSFP+ Port | |
| 0231A1LS | LSWM1QSTK0 - 40G QSFP+ 1m Cable |
| 0231A1LT | LSWM1QSTK1 - 40G QSFP+ 3m Cable |
| 0231A1LU | LSWM1QSTK2 - 40G QSFP+ 5m Cable |
| 0231A9CT | QSFP-40G-D-AOC-3M - 40G QSFP+ to 40G QSFP+ 3m Active Optical Cable |
| 0231A3U4 | QSFP-40G-D-AOC-10M - 40G QSFP+ to 40G QSFP+10m AOC |
| 0231A3U5 | QSFP-40G-D-AOC-20M - 40G QSFP+ to 40G QSFP+20m AOC |
| 0231A3U3 | QSFP-40G-D-AOC-7M - 40G QSFP+ to 40G QSFP+7m AOC |
| 0231A1LV | LSWM1QSTK3 - 40G QSFP+ to 4x10G SFP+ 1m Cable |
| 0231A1LW | LSWM1QSTK4 - 40G QSFP+ to 4x10G SFP+ 3m Cable |
| 0231A1LX | LSWM1QSTK5 - 40G QSFP+ to 4x10G SFP+ 5m Cable |
| 0231A2E4 | QSFP-40G-LR4-WDM1300 - QSFP+ 40G optical module (1310 nm, 10 km, LR4, LC) |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850 - QSFP+ 40G BIDI Optical Module (850 nm, 100 m, SR) |
| 0231AJHT | QSFP-40G-LX4-WDM1300 - QSFP+ 40G Optical Module (1310nm, 150m, OM3, LX4) |
| 0231A4PB | QSFP-40G-LR4L-WDM1300 - QSFP+ 40G Optical Module (1310nm, 2km, LR4L, LC) |
| 0231AKDE | QSFP-40G-SR4-MM850-H - QSFP+ 40G Optical Module (850 nm, 100 m, SR4, supports 1-to-4 splitting) |
| 0231A2NF | QSFP-40G-SR4-MM850 - QSFP+ 40G Optical Module (850 nm, 100 m, SR4, supports 1-to-4 splitting) |
| 0231A2KL | QSFP-40G-CSR4-MM850 - QSFP+ 40G Optical Module (850 nm, 300 m, CSR4, supports 1-to-4 splitting) |
| QSFP28-Port | |
| 0231A4B3 | QSFP-100G-D-AOC-10M - 100G QSFP28 to 100G QSFP28 10m AOC |
| 0231A4B4 | QSFP-100G-D-AOC-20M - 100G QSFP28 to 100G QSFP28 20m AOC |
| 0231A4B2 | QSFP-100G-D-AOC-7M - 100G QSFP28 to 100G QSFP28 7m AOC |
| 0231A4UF | QSFP-100G-LR4-WDM1300 - 100G QSFP28 Optical Module (1310 nm, 10 km, LR4, WDM, LC) |
| 0231A5LL | QSFP-100G-LR4L-WDM1300 - 100G QSFP28 Optical Module (1310nm, 2km, LR4L, CWDM4, LC) |
| 0231A4B1 | QSFP-100G-SR4-MM850 - 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO) |
| Fan Options | |
| 0231AG9F | LSPM1FANSB-SN - H3C Fan Module (Side-Exhaust Fan) |
| Power Module | |
| 9803A05Q | PSR1600-54A-B - H3C-PSR1600-54A-B-1600W/AC PoEPower Module |
| 9803A05N | PSR600-54A-B - H3C-PSR600-54A-B-600W/AC PoEPower Module |
| 9803A05P | PSR920-54A-B - H3C-PSR920-54A-B-920W/AC PoEPower Module |
| Optical hybrid cable connectorsand pigtails | |
| 1413A02S | PoE-PoDLCA-ODF-1.5m - All-Optical 3.0 Hybrid Fiber-Optic Cable Modular Connector Pigtail - PoDLC/PC-ODF - Single-Mode - 1.5 m |
| Hybrid Optical-Electrical Cable | |
| 2505A006 | CAB-17AWG-500-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 500m (LSZH) |
| 2505A007 | CAB-21AWG-200-PVC - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 200m (PVC) |
| 2505A008 | 2505A008 - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 200m (PVC) |
| 2505A009 | CAB-17AWG-100-PVC - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 100m (PVC) |
| 2505A00A | CAB-21AWG-100-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 100m (LSZH) |
| 2505A00B | CAB-17AWG-100-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 100m (LSZH) |
| 2505A00C | CAB-17AWG-200-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 200m (LSZH) |
| 2505A00D | CAB-21AWG-100-PVC - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 100m (PVC) |
| 2505A00E | CAB-21AWG-500-PVC - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 500m (PVC) |
| 2505A00F | 2505A00F - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 33mm - 17AWG - 2C+2C - 500m (PVC) |
| 2505A00G | CAB-21AWG-200-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 200m (LSZH) |
| 2505A00H | CAB-21AWG-500-LSZH - Symmetrical Twisted Pair Cable - Optical Hybrid Cable - 13mm - 21AWG - 2C+2C - 500m (LSZH) |
| 2505A00J | HYBRID CABLE-200-0.5 - 200-meter hybrid optical-electrical cable |
| 2505A00K | HYBRID CABLE-100-0.5 - 100-meter fiber-optic hybrid cable |
| 2505A00L | HYBRID CABLE-500-0.5 - 500-meter hybrid optical-electrical cable |
| 2505A00M | HCAB-GDJV-20AWG-200m-2F - GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.9 mm) |
| 2505A00N | HCAB-GDJV-20AWG-500m-2F - GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.9 mm) |
| 2505A00P | HCAB-GDJV-20AWG-100m-2F - GDJV-20AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.9 mm) |
| 2505A00Q | HCAB-GDJV-21AWG-200-2F - GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.7 mm) |
| 2505A00R | HCAB-GDJV-21AWG-500m-2F - GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.7 mm) |
| 2505A00S | HCAB-GDJV-21AWG-100-2F - GDJV-21AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.7 mm) |
| 2505A00T | HCAB-GDJV-17AWG-100m-2F - GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 6.2 mm) |
| 2505A00U | HCAB-GDJV-17AWG-200m-2F - GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 6.2 mm) |
| 2505A00V | HCAB-GDJV-17AWG-500m-2F - GDJV-17AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 6.2 mm) |
| 2505A00W | HCAB-GDJH-21AWG-500m-2F - GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.7 mm) |
| 2505A00X | HCAB-GDJH-21AWG-200m-2F - GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.7 mm) |
| 2505A00Y | HCAB-GDJH-21AWG-100m-2F - GDJH-21AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.7 mm) |
| 2505A010 | HCAB-GDJH-20AWG-100m-2F - GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 5.9 mm) |
| 2505A011 | HCAB-GDJH-20AWG-200m-2F - GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 5.9 mm) |
| 2505A012 | HCAB-GDJH-20AWG-500m-2F - GDJH-20AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 5.9 mm) |
| 2505A013 | HCAB-GDJH-17AWG-500m-2F - GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 500 meters (OD 6.2 mm) |
| 2505A014 | HCAB-GDJH-17AWG-100m-2F - GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 100 meters (OD 6.2 mm) |
| 2505A015 | HCAB-GDJH-17AWG-200m-2F - GDJH-17AWG-2C+2C Hybrid Optical-Electrical Cable, 200 meters (OD 6.2 mm) |
| Cable Management Box | |
| 9821A0K9 | H3C GC-KDS24-HUS1-1 - Optical Hybrid Switch Cable Management Box (1U, Supports 48 cables, for FS5500Series) |
| Ear Hook | |
| 2150A03X | LS-FL-LE-1U - 1Ucompatible lug-1UChassis |
| Heat-Shrink Tubing | |
| 9904A0KE | H3C GC-SD-B0 - Optical Hybrid Solution Customized Fiber Fusion Heat Shrink Tubing (2.3mm I.D., 50pcs included) |
| Cold-pressed intermediate terminal | |
| 9904A0KD | H3C GC-BNYF1.25 - Cold-Pressed Intermediate Terminals (BNYF1.25, 100 pcs included) |
| Configuration Cables | |
| 04042967 | CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port) |
| 0404A1EE | CAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP) |
| Product Identity | |
| Brand | H3C |
| Series | H3C FS6300V2-EI Series Switch |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Switching Capacity specification for LS-FS6300V2-48UX2Q4C-EI?
What is the Packet Forwarding Rate specification for LS-FS6300V2-48UX2Q4C-EI?
What is the Console Port specification for LS-FS6300V2-48UX2Q4C-EI?
What is the Dimensions (Width x Depth x Height) (Unit: mm) specification for LS-FS6300V2-48UX2Q4C-EI?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?