| Key Specifications |
|---|
| Power Supply | AC:100V~240V |
| System Management | Supports FTP, TFTP, Xmodem |
| Fabric Module Quantity | 6 |
| Hardware Architecture | Orthogonal CLOS Architecture |
| Redundancy design | Supervisor Engine Module, Fabric Module, Power Supply, Fan (Front-to-Back Airflow) |
| Multicast | Supports PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, Any-RP, and other routing protocols |
| Product Specifications |
|---|
| Power Supply | AC:100V~240V |
| System Management | Supports FTP, TFTP, Xmodem |
| Fabric Module Quantity | 6 |
| Hardware Architecture | Orthogonal CLOS Architecture |
| Redundancy design | Supervisor Engine Module, Fabric Module, Power Supply, Fan (Front-to-Back Airflow) |
| Multicast | Supports PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, Any-RP, and other routing protocols |
| Product Specifications |
|---|
| Fabric Module Quantity | 6 |
| Hardware Architecture | Orthogonal CLOS Architecture |
| Redundancy design | Supervisor Engine Module, Fabric Module, Power Supply, Fan (Front-to-Back Airflow) |
| Ethernet Features | Supports 802.1Q |
| Routing Features | Supports Static Routing, RIP, OSPF, IS-IS, BGP4, etc. |
| IPv6 Features | Supports IPv6 ND (Neighbor Discovery) |
| Multicast | Supports PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, Any-RP, and other routing protocols |
| ACL/Qo S | Supports Standard and Extended ACL |
| Programmability and Automation | Supports Ansible automation technology |
| Lossless Network | Supports lossless Ethernet features such as RDMA, RoCE v2, PFC, ECN, etc. |
| Load Balancing | Supports FGLB, LBN/LBN Enhanced, Path Navigation, Per-Packet Adaptive Tuning, Spray*, spraylink* |
| SDN/OPENFLOW | Supports OPENFLOW 1.3 standard |
| VXLAN | Supports VXLAN Layer 2 switching |
| Visualization | Supports INT |
| MPLS/VPLS | Supports L3 MPLS VPN |
| Security Mechanisms | Supports EAD security solution |
| System Management | Supports FTP, TFTP, Xmodem |
| Reliability | Independent hardware Fabric Module design, achieving true separation of control and forwarding. |
| Compatible with Multiple Cloud Platforms | Supports adaptation and compatibility with third-party cloud platform products and technical capabilities. |
| Green Energy Saving | Supports 802.3az Energy Efficient Ethernet |
| Ambient temperature | Operating ambient temperature: 0℃~40℃ Storage ambient temperature: -40℃~70℃ |
| Ambient humidity | Operating ambient humidity: 5%~95% (non-condensing) Storage ambient humidity: 5%~95% (non-condensing) |
| Power Supply | AC:100V~240V |
| Catalog Description |
|---|
| Description | H3C S12508G-AF,Combined Configuration,(Chassis+M3SUPS2*2+M3SFS08F2*4+M108XFAN*2+AC Power Module*4) |
| Key Features |
|---|
| Feature 1 | Advanced CLOS+Multi-level Multi-plane Switching Architecture. The S12500G-AF Series Chassis switch adopts an advanced CLOS+multi-level multi-plane switching architecture, featuring an orthogonal backplane-less design. Service Module cards and Fabric Modules adopt a fully orthogonal design (90 degrees). Cross-Line Card service traffic passes directly to the Fabric Module via orthogonal connectors, reducing backplane wiring to zero (greatly avoiding signal attenuation), significantly enhancing system bandwidth and scalability, and allowing overall capacity to scale smoothly. |
| Feature 2 | Supports cell switching, possesses dynamic routing capability, load balances traffic across multiple switching fabrics, ensuring a non-blocking switching matrix while improving switching fabric utilization efficiency. |
| Feature 3 | Supports high-density 10GE, 25GE, 40GE, 100GE, 200GE, and 400GE Ethernet ports. Supports 100G split into 4*10G, 100G split into 4*10/25G, 400GE split into 2*200G/4*100G, fully meeting future application development needs. |
| Feature 4 | Forwarding and control separation. Switching fabric supports 5+1 or 4+2 redundancy. |
| Feature 5 | AI-Inside driven intelligent network S12500G-AF Series switch supports Seerblade high-performance AI computing Module, providing users with an intelligent computing platform deeply integrated with the network, featuring high-performance CPU, GPU, and large storage capacity, meeting the lightweight deployment needs of AI+Big Data applications for SME users. |
| Ordering Information |
|---|
| SFP Gigabit port | |
| 02312173 | SFP-GE-LH80-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP Gigabit port |
| 0231A563 | SFP-GE-LX-SM1310-A; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP Gigabit port |
| 0231A962 | SFP-GE-LX-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP Gigabit port |
| 02312170 | SFP-GE-LH40-SM1310; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP Gigabit port |
| 0231A963 | SFP-GE-LH40-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP Gigabit port |
| 02312172 | SFP-GE-LH40-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 40km, LC); Type: SFP Gigabit port |
| 0231A964 | SFP-GE-LH80-SM1550-D; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP Gigabit port |
| 0231A562 | SFP-GE-SX-MM850-A; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP Gigabit port |
| 0231A961 | SFP-GE-SX-MM850-D; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP Gigabit port |
| 0231A11U | SFP-GE-LX-SM1310-BIDI; Optical transceiver - SFP Gigabit BIDI module-TX1310/RX1490, 10km, LC; Type: SFP Gigabit port |
| 0231A11V | SFP-GE-LX-SM1490-BIDI; Optical transceiver - SFP Gigabit BIDI module-TX1490/RX1310, 10km, LC; Type: SFP Gigabit port |
| Configuration Options | |
| 0231AGQ2 | LSXM3SUPS2 |
| 0231AGJ3 | LSXM3SFS08F2 |
| Fabric Module Filler Panel | |
| 0231A3RL | LSXM1BFP08A; 08Fabric Module Filler Handle Strip; Type: Fabric Module Filler Panel |
| QSFP-DD port | |
| 0231A4B3 | QSFP-100G-D-AOC-10M; 100G QSFP28 to 100G QSFP28 10m AOC; Type: QSFP-DD port |
| 0231A4AY | QSFP-100G-D-CAB-1M; Type: QSFP-DD port |
| 0231A4B4 | QSFP-100G-D-AOC-20M; 100G QSFP28 to 100G QSFP28 20m AOC; Type: QSFP-DD port |
| 0231A4B0 | QSFP-100G-D-CAB-3M; Type: QSFP-DD port |
| 0231A5HB | QSFP-100G-D-CAB-5M; Type: QSFP-DD port |
| 0231A4B2 | QSFP-100G-D-AOC-7M; 100G QSFP28 to 100G QSFP28 7m AOC; Type: QSFP-DD port |
| 0231A4UF | QSFP-100G-LR4-WDM1300; 100G QSFP28 optical transceiver (1310nm, 10km, LR4, WDM, LC); Type: QSFP-DD port |
| 0231A9V9 | QSFP-100G-CWDM4-SM1300-A; 100G QSFP28 optical transceiver (1310nm, 2km, CWDM4, LC); Type: QSFP-DD port |
| 0231A5LL | QSFP-100G-LR4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 2km, LR4L, CWDM4, LC); Type: QSFP-DD port |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 40km, ER4L, WDM, LC); Type: QSFP-DD port |
| 0231A5HA | QSFP-100G-PSM4-SM1310; 100G QSFP28 optical transceiver (1310nm, 500m, PSM4, MPO/APC); Type: QSFP-DD port |
| 0231AH0E | QSFP-100G-SR4-MM850-H; 100G QSFP28 optical transceiver (850nm, 100m OM4, SR4, MPO); Type: QSFP-DD port |
| 0231A5H6 | 100G QSFP28 optical transceiver (850nm, 100m OM4, SWDM4, LC); Type: QSFP-DD port |
| 0231A4B1 | QSFP-100G-SR4-MM850; 100G QSFP28 optical transceiver (850nm, 100m OM4, SR4, MPO); Type: QSFP-DD port |
| 0231AC0J | QSFP-100G-LR4-WDM1300-A; 100G QSFP28 optical transceiver (1310nm, 10km, LR4, WDM, LC); Type: QSFP-DD port |
| 0231A9VA | Type: QSFP-DD port |
| 0231AL4Q | QSFP56-200G-D-DAC-1M; Type: QSFP-DD port |
| 0231AL4X | QSFP56-200G-D-DAC-2M; Type: QSFP-DD port |
| 0231AL4Y | QSFP56-200G-D-DAC-3M; Type: QSFP-DD port |
| 0231AJHU | QSFP56-200G-FR4-WDM1300; 200G QSFP56single-modeoptical transceiver (1300nm, 2km, FR4, SMF/LC); Type: QSFP-DD port |
| 0231AJHS | QSFP56-200G-SR4-MM850; 200G QSFP56multimodeoptical transceiver (850nm, 100m OM4, 70m OM3, SR4, MPO12/UPC); Type: QSFP-DD port |
| 0231AJ4J | QSFPDD-400G-LR8-WDM1300; 400G QSFP-D Dsingle-modeoptical transceiver (1300nm, 10km, LR8, LC); Type: QSFP-DD port |
| 0231ALH4 | QSFPDD-400G-ZR-B; Type: QSFP-DD port |
| 0231AM4H | QSFPDD-400G-2QSFP56-200G-AOC-10m; Type: QSFP-DD port |
| 0231AM4K | QSFPDD-400G-2QSFP56-200G-AOC-20m; Type: QSFP-DD port |
| 0231AMGR | QSFPDD-400G-2QSFP56-200G-AOC-30m; Type: QSFP-DD port |
| 0231AMGQ | QSFPDD-400G-2QSFP56-200G-AOC-50m; Type: QSFP-DD port |
| 0231AM4J | QSFPDD-400G-2QSFP56-200G-AOC-5m; Type: QSFP-DD port |
| 0231AM4G | QSFPDD-400G-2QSFP56-200G-AOC-7m; Type: QSFP-DD port |
| 0231ADR7 | QSFPDD-400G-D-CAB-2M; Type: QSFP-DD port |
| 0231ANDN | QSFPDD-400G-D-AOC-5m; Type: QSFP-DD port |
| 0231AESL | QSFPDD-400G-FR4-WDM1300; 400G QSFPD Dsingle-modeoptical transceiver (1300nm, 2km, FR4, LC); Type: QSFP-DD port |
| 0231AE00 | QSFPDD-400G-SR8-MM850; Type: QSFP-DD port |
| 0231AM92 | QSFPDD-400G-SR4-MM850; Type: QSFP-DD port |
| 0231A1LS | LSWM1QSTK0; 40G QSFP+ 1m cable; Type: QSFP-DD port |
| 0231A1LT | LSWM1QSTK1; 40G QSFP+ 3m cable; Type: QSFP-DD port |
| 0231A1LU | LSWM1QSTK2; 40G QSFP+ 5m cable; Type: QSFP-DD port |
| 0231AKDD | QSFP-40G-D-AOC-10M-H; Type: QSFP-DD port |
| 0231AKDC | QSFP-40G-D-AOC-20M-H; Type: QSFP-DD port |
| 0231AKDF | QSFP-40G-D-AOC-7M-H; Type: QSFP-DD port |
| 0231A3U4 | QSFP-40G-D-AOC-10M; 40G QSFP+ to 40G QSFP+10m AOC; Type: QSFP-DD port |
| 0231A3U5 | QSFP-40G-D-AOC-20M; 40G QSFP+ to 40G QSFP+20m AOC; Type: QSFP-DD port |
| 0231A3U3 | QSFP-40G-D-AOC-7M; 40G QSFP+ to 40G QSFP+7m AOC; Type: QSFP-DD port |
| 0231A2E4 | QSFP-40G-LR4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 10km, LR4, LC); Type: QSFP-DD port |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850; QSFP+ 40G BIDI optical transceiver (850nm, 100m, SR); Type: QSFP-DD port |
| 0231AJHT | QSFP-40G-LX4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 150m, OM3, LX4); Type: QSFP-DD port |
| 0231A4PB | QSFP-40G-LR4L-WDM1300; QSFP+ 40G optical transceiver (1310nm, 2km, LR4L, LC); Type: QSFP-DD port |
| 0231A4UG | QSFP-40G-ER4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 40km, ER4, LC); Type: QSFP-DD port |
| 0231A2UQ | QSFP-40G-LR4-PSM1310; Type: QSFP-DD port |
| 0231A2NF | QSFP-40G-SR4-MM850; Type: QSFP-DD port |
| 0231A2KL | QSFP-40G-CSR4-MM850; Type: QSFP-DD port |
| Configuration Options | |
| 0231AGJ5 | LSXM3CDQ16SF2 |
| QSFP28 port | |
| 0231A5HD | QSFP-100G-4SFP-25G-CAB-3M; Type: QSFP28 port |
| 0231A5HE | QSFP-100G-4SFP-25G-CAB-5M; Type: QSFP28 port |
| 0231ANBT | QSFP-100G-BIDI-MM850-G2; 100G QSFP28 multimodeoptical transceiver (850nm, 100m OM4, 70m OM3, BIDI, LC); Type: QSFP28 port |
| 0231A5UL | QSFP-100G-eSR4-MM850; 100G QSFP28 optical transceiver (850nm, 300m OM4, eSR4, MPO); Type: QSFP28 port |
| 0231A7W9 | QSFP-100G-BIDI-MM850; 100G QSFP28 optical transceiver (850nm, 100m OM4, BIDI, LC); Type: QSFP28 port |
| 0231A1LV | LSWM1QSTK3; 40G QSFP+ to 4x10G SFP+ 1m cable; Type: QSFP28 port |
| 0231A1LW | LSWM1QSTK4; 40G QSFP+ to 4x10G SFP+ 3m cable; Type: QSFP28 port |
| 0231A1LX | LSWM1QSTK5; 40G QSFP+ to 4x10G SFP+ 5m cable; Type: QSFP28 port |
| 0231AKDB | QSFP-40G-CSR4-MM850-H; Type: QSFP28 port |
| Configuration Options | |
| 0231AGJ4 | LSXM3CGQ18SF2 |
| QSFP28 port | |
| 0231A5HC | QSFP-100G-4SFP-25G-CAB-1M; Type: QSFP28 port |
| Configuration Options | |
| 0231AGHL | LSXM3CGQ36SF2 |
| 0231AL31 | LSXM4CGQ36SF2 |
| 0231AGJ2 | LSXM3QGS36SF2 |
| SFP28 port | |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI; SFP Gigabit BIDI optical transceiver (TX1310/RX1550nm, 40km, LC); Type: SFP28 port |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI; SFP Gigabit BIDI optical transceiver (TX1490/RX1550nm, 70km, LC); Type: SFP28 port |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI; SFP Gigabit BIDI optical transceiver (TX1550/RX1310nm, 40km, LC); Type: SFP28 port |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI; SFP Gigabit BIDI optical transceiver (TX1550/RX1490nm, 70km, LC); Type: SFP28 port |
| 0231A085 | SFP-GE-T; SFP GE copper transceiver (100m, RJ45); Type: SFP28 port |
| 0231A960 | SFP-GE-T-D; SFP GE copper transceiver (100m, RJ45); Type: SFP28 port |
| 0231A6NG | SFP-25G-D-AOC-10M; Type: SFP28 port |
| 0231A5GY | SFP-25G-D-CAB-1M; Type: SFP28 port |
| 0231A6NH | SFP-25G-D-AOC-20M; Type: SFP28 port |
| 0231A5H0 | SFP-25G-D-CAB-3M; Type: SFP28 port |
| 0231A6ND | SFP-25G-D-AOC-3M; Type: SFP28 port |
| 0231A5H1 | SFP-25G-D-CAB-5M; Type: SFP28 port |
| 0231A6NE | SFP-25G-D-AOC-5M; Type: SFP28 port |
| 0231A6NF | SFP-25G-D-AOC-7M; Type: SFP28 port |
| 0231ABR6 | SFP-25G-LR-SM1310; 25G SFP28 optical transceiver (1310nm, 10km, LR, SM, LC); Type: SFP28 port |
| 0231A4Y2 | SFP-25G-SR-MM850; 25G SFP28 optical transceiver (850nm, 100m, SR, MM, LC); Type: SFP28 port |
| 0231AH0D | SFP-25G-SR-MM850-H; 25G SFP28 optical transceiver (850nm, 100m, SR, MM, LC); Type: SFP28 port |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1270nm/RX1330nm, 10km, LC); Type: SFP28 port |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1270nm/RX1330nm, 40km, LC); Type: SFP28 port |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1330nm/RX1270nm, 10km, LC); Type: SFP28 port |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1330nm/RX1270nm, 40km, LC); Type: SFP28 port |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1490nm/RX1550nm, 80km, LC); Type: SFP28 port |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI; SFP+ 10GbE BIDI optical transceiver (TX1550nm/RX1490nm, 80km, LC); Type: SFP28 port |
| 0231A0A8 | SFP-XG-LX-SM1310; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP28 port |
| 0231A1RQ | SFP-XG-LX-SM1310-D; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP28 port |
| 0231A2L3 | SFP-XG-LX-SM1310-E; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP28 port |
| 0231A0SP | SFP-XG-LH40-SM1550; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP28 port |
| 0231A1RR | SFP-XG-LH40-SM1550-D; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP28 port |
| 0231A1PA | SFP-XG-LH80-SM1550; SFP+ 10GbE optical transceiver (1550nm, 80km, LC); Type: SFP28 port |
| 0231A2T6 | SFP-XG-LH80-SM1550-D; SFP+ 10GbE optical transceiver (1550nm, 80km, LC); Type: SFP28 port |
| 0231A0A6 | SFP-XG-SX-MM850-A; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP28 port |
| 0231A1RP | SFP-XG-SX-MM850-D; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP28 port |
| 0231A2L4 | SFP-XG-SX-MM850-E; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP28 port |
| 0231A0AK | LSWM1STK; SFP+ cable0.65m; Type: SFP28 port |
| 0231A0AL | LSWM2STK; SFP+ cable1.2m; Type: SFP28 port |
| 0231A0AM | LSWM3STK; SFP+ cable3m; Type: SFP28 port |
| 0231A0G1 | LSTM1STK; SFP+ cable5m; Type: SFP28 port |
| Configuration Options | |
| 0231AGHP | LSXM3YGS48SF2 |
| SFP+ 10GbE port | |
| 0231AJXK | SFP-2.5G-LX10-SM1310-DR-I; SFP 2.5G/1G single-modeindustrial temperatureoptical transceiver (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231AH0W | SFP-10GE-T; SFP+ 10G Ecopper transceiver (Cat6a/Cat7, 30m, RJ45); Type: SFP+ 10GbE port |
| 0231AKBC | SFP-XG-SX-MM850-H; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP+ 10GbE port |
| Configuration Options | |
| 0231AGHN | LSXM3TGS48SF2 |
| QSFP28 port | |
| 0231AG54 | QSFP-40G-LR4-PSM1310-A; Type: QSFP28 port |
| Configuration Options | |
| 0231AJD0 | LSXM3TGT48CQSF2 |
| 0231AGJ6 | LSXM3CDQ8SF2 |
| 0231ANEN | LSXM3CCQ36SG2 |
| QSFP112 400Gport | |
| 0231AN5P | Q112-400G-2Q112-200G-AOC-10m-SM; Type: QSFP112 400Gport |
| 0231AN54 | Q112-400G-2Q112-200G-AOC-20m-SM; Type: QSFP112 400Gport |
| 0231AN5H | Q112-400G-2Q112-200G-AOC-30m-SM; Type: QSFP112 400Gport |
| 0231AN5Q | Q112-400G-2Q112-200G-AOC-50m-SM; Type: QSFP112 400Gport |
| 0231AN5T | QSFP112-400G-D-AOC-10m-SM; Type: QSFP112 400Gport |
| 0231AN5U | QSFP112-400G-D-AOC-20m-SM; Type: QSFP112 400Gport |
| 0231AN5N | QSFP112-400G-D-AOC-30m-SM; Type: QSFP112 400Gport |
| 0231AN5G | QSFP112-400G-D-AOC-50m-SM; Type: QSFP112 400Gport |
| 0231AM98 | QSFP112-400G-FR4-WDM1300; 400G QSFP112single-modeoptical transceiver (1300nm, 2km, FR4, LC); Type: QSFP112 400Gport |
| 0231AM9A | QSFP112-400G-DR4-SM1310; Type: QSFP112 400Gport |
| 0231APVF | QSFP112-400G-SR8-MM850; 400G QSFP112optical transceiver (850nm, 100m OM4, SR8, MPO16/APC); Type: QSFP112 400Gport |
| 0231AM99 | QSFP112-400G-VR4-MM850; Type: QSFP112 400Gport |
| 0231AH0H | QSFP-100G-D-AOC-10M-H; Type: QSFP112 400Gport |
| 0231AH0J | QSFP-100G-D-AOC-20M-H; Type: QSFP112 400Gport |
| 0231AH0K | QSFP-100G-D-AOC-7M-H; Type: QSFP112 400Gport |
| 0231AFJB | QSFP-100G-ER4-WDM1300; 100G QSFP28 optical transceiver (1300nm, 40km, ER4, WDM, LC); Type: QSFP112 400Gport |
| 0231AL4P | QSFP56-200G-D-AOC-10M; Type: QSFP112 400Gport |
| 0231AL52 | QSFP56-200G-D-AOC-20M; Type: QSFP112 400Gport |
| 0231AL4N | QSFP56-200G-D-AOC-5M; Type: QSFP112 400Gport |
| 0231AL51 | QSFP56-200G-D-AOC-7M; Type: QSFP112 400Gport |
| 0231AKDE | QSFP-40G-SR4-MM850-H; Type: QSFP112 400Gport |
| Configuration Options | |
| 0231AN2A | LSXM3CDHQ36SG2 |
| 0231AL8J | LSXM3CGQ48SG2 |
| 0231APVD | LSXM4CGQ48SG2 |
| 3130A3UM | LIS-SDNAPP-MC-NAT |
| 3130A3UA | LIS-U-WAF-1Y |
| 3130A3U9 | LIS-U-WAF-3Y |
| 3130A2MP | LIS-U-LIS-1Y |
| 3130A2MR | LIS-U-LIS-3Y |
| 3130A375 | LIS-SER-URL-1Y |
| 3130A376 | LIS-SER-URL-3Y |
| 3130A4DQ | LIS-SECBLADEA-TI-1Y |
| 3130A4D8 | LIS-SECBLADEA-TI-3Y |
| 3130A1QN | LIS-U-IPS-1Y |
| 3130A1QP | LIS-U-IPS-3Y |
| 3130A1QS | LIS-U-LB; H3C Secblade-Advance, LB License Certificate |
| 3130A1QV | H3C S12500G-AF switch Series |
| 3130A1QT | LIS-U-SSL-200 |
| 3130A1QW | H3C S12500G-AF switch Series |
| 3130A1QU | LIS-U-SSL-500 |
| 3130A1QQ | LIS-U-ACG-1Y |
| 3130A1QR | LIS-U-ACG-3Y |
| 3130A1YG | LIS-U-AV-1Y |
| 3130A1YH | LIS-U-AV-3Y |
| 0231A2UH | LSXM108XFAN; H3C S12508X-AF Ethernet Switch Fan Module |
| 0231A2SN | PSR2400-54A; AC Power Supply Module-2400W |
| Power Cord | |
| 0404A0C2 | CAB-AC Pwr 3C-3m-PDU; PDU Power Cord-3.0m-3*1.5mm^2-black (C20connector (3P)straight male250V16A) (227 IEC 53(RVV)) (C19connector (3P)straight female250V16A)-China Standard; Type: Power Cord |
| 0404A13W | CAB-AC POWER 3C-5.0m-PDU; PDU Power Cord-5.0m-3*1.5mm^2-black (C20connector (3P)straight male250V16A) (227 IEC 53(RVV)) (C19connector (3P)straight female250V16A)-China Standard; Type: Power Cord |
| 0404A19G | H3C S12500G-AF switch Series; Type: Power Cord |
| 0404A0MW | CAB-AC-16A-PDU-3m-Eu; PDU Power Cord-3.0m-1.5mm^2-black (C20connector (3P)straight male250V16A) (H05VV-F) (C19connector (3P)straight female250V16A)-European Standard; Type: Power Cord |
| 0404A0GE | CAB-HVDC-16A-PDU-3m-Y; PDU Power Cord-3.0m-3*1.5mm^2-yellow121C (C20connector (3P)straight male250V16A) (227 IEC 53(RVV)) (C19connector (3P)straight female250V16A)-China Standard; Type: Power Cord |
| 0404A0LH | CAB-HVDC-16A-PDU-5m-Y; PDU Power Cord-5.0m-3*1.5mm^2-yellow121C (C20connector (3P)straight male250V16A) (227 IEC 53(RVV)) (C19connector (3P)straight female250V16A)-China Standard; Type: Power Cord |
| Configuration Options | |
| 8814A14L | SV-PS-IFAS-OAS |
| Rail Kit | |
| 0231A0PL | LSTM2KSGD0; Type: Rail Kit |
| 0231A4EK | LSXM1BSR; 1U Adjustable Rack Rail-630mm~900mm; Type: Rail Kit |
| Serial Cable | |
| 04042967 | CAB-CON-1.8m; Type: Serial Cable |
| 0404A1EE | CAB-Console-1.8m-W31R; Console Cable-1.8m (RJ45P) (UL2725(3C28AWG)) (USB AP); Type: Serial Cable |
| Base Configuration | |
| 0150A2D5 | LS-Z+M3+A-8 |
| Product Identity |
|---|
| Brand | H3C |
| Series | H3C S12500G-AF Series Switches |