H3C LS-Z+M4+A-1 Ethernet Switch is H3C S12504G-AF,Combined Configuration,(Chassis+M1SUP04T2*2+M1SFT04F2*4+M2TGS48TD2+AC2400*2+FAN*2).

H3C LS-Z+M4+A-1 Ethernet Switch
H3C LS-Z+M4+A-1 Ethernet Switch. H3C S12504G-AF,Combined Configuration,(Chassis+M1SUP04T2*2+M1SFT04F2*4+M2TGS48TD2+AC2400*2+FAN*2).
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Key Specifications | |
|---|---|
| MPU console port | 1 / 1 |
| max ND table size for IPv6 | 67690 / 78584 |
| MPU slots | 2 / 2 / 2 |
| Maximum power consumption | 5800 W / 12000 W / 22400W |
| MPU processor | Quad Core 2.2GHz / Quad Core 2.2GHz |
| Buffer | 32M(T series LPU)36M(S series LPU) |
| Product Specifications | |
| Buffer | 32M(T series LPU)36M(S series LPU) |
| Switching capacity | 57.6T/387Tbps / 115.2T/516Tbps / 230.4T/1032Tbps |
| Throughput | 21600Mpps / 43200Mpps / 86400Mpps |
| MPU slots | 2 / 2 / 2 |
| LPU slots | 4 / 8 / 16 |
| Maximum power consumption | 5800 W / 12000 W / 22400W |
| Weight (full configuration) | ≤ 110 kg≤ 242.5 lb / ≤ 190 kg≤ 418.9 lb / ≤ 352 kg≤ 776 lb |
| Dimensions (H x W x D) | 264 x 440 x 857 mm (6U)10.4 x 17.3 x 33.7 in / 531 x 440 x 857 mm (12U)20.9 x 17.3 x 33.7 in / 931 x 440 x 857 mm (21U)36.7 x 17.3 x 33.7 in |
| Switching fabric module slots | 6 / 6 / 6 |
| MPU name | LSXM1SUP04T2 / LSXM2SUPT2 |
| MPU processor | Quad Core 2.2GHz / Quad Core 2.2GHz |
| MPU SDRAM | 16 GB / 16 GB |
| MPU flash | T series: 8 GBLSXM1SUPS2 used in the S12508G-AF: 1GLSXM3SUPS2 used in the S12508G-AF/S12516G-AF:2G LSXM3SUP04S2 used in the S12504G-AF:2G |
| MPU console port | 1 / 1 |
| MPU MGMT ports | 2 / 2 |
| MPU USB port | 1 / 1 |
| Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays |
| Temperature | Operating temperature: 0°C to 40°C (32°F to 104°F)Storage temperature: -40°C to 70°C (-40°F to 158°F) |
| Humidity | 5% to 95% (non-condensing) |
| Green | Support 802.3az energy efficient Ethernet |
| Safety | UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter JGB 4943.1 |
| Product Specifications | |
| Device virtualization | IRF2.0M-LAG(DRNI)S-MLAG |
| Network virtualization | BGP-EVPNVxLAN |
| VXLAN | L2 VxLAN gatewayL3 VxLAN gatewayDistributed VxLAN gatewayCentralized VxLAN gatewayEVPN VxLANmanual configured VxLANIPv4 VxLAN tunnelIPv6 VxLAN tunnelQinQ VxLAN accessVxLAN DCI, vxlan mapping and route regeneration to interconnect DCs by L2 and L3VxLAN multicastEVPN-VxLAN multicast |
| MPLS/VPLS | Support L3 MPLS VPNSupport L2 VPN: VLL (Martini, Kompella)Support MCESupport MPLS OAMSupport VPLS, VLLSupport hierarchical VPLS and QinQ+VPLS accessSupport P/PE functionSupport LDP protocol |
| SDN | H3C SeerEngine-DC |
| Lossless network | PFC and ECNDCBXRDMA and ROCEPFC deadlock watchdogECN overlay |
| Programmability | Openflow1.3NetconfAnsiblePython/TCL/Restful API to realize DevOps automated operation and maintenance |
| Traffic analysis | SflowNetstream(TE LPUs and S series LPUs) |
| VLAN | Port-based VLANsMac-based VLAN,Subnet-based VLAN and Protocol VLANVLAN mappingQinQMVRP(Multiple VLAN Registration Protocol)Super VLANPVLAN |
| MAC address | Dynamic learning and aging of mac address entriesDynamic,static and blackhole entriesMac address limiting on ports |
| IPv4 routing | Static routing and default routingRIP(Routing Information Protocol) v1/2OSPF (Open Shortest Path First) v2ISIS(Intermediate System to Intermediate system)BGP (Border Gateway Protocol)Routing policyPBR |
| IPv6 routing | Static routing and default routingRIPngOSPFv3IPv6 IS ISBGP4+Routing policyPBR |
| Multicast | IGMP snoopingMLD snoopingIPv4 and IPv6 multicast VLANIPv4 and IPv6 PIM snoopingIGMP and MLDPIM and IPv6 PIMMSDPMulticast VPN |
| Telemetry | gRPCERSPANMirror on dropTelemetry StreamINTiNQAPacket tracePacket capture |
| Configuration and maintenance | Console telnet and SSH terminalsSNMPv1/v2/v3ZTPSystem logFile upload and download via FTP/TFTPBootRom update and remote updateNQAping,tracert VxLAN ping and VxLAN tracertNTPPTP(1588v2)GIR Graceful Insertion and Removal |
| Security and management | Micro-SegmentationHierarchical management and password protection of usersAuthentication methods,including AAA,RADIUS and HWTACACSSupport DDos, ARP attack and ICMP attack functionIP-MAC-port binding and IP Source GuardSSH 2.0HTTPSSSLPKIBoot ROM access control (password recovery)RMON |
| Product Specifications | |
| Virtualization | IRF2.0 stack / 2 / 2 |
| M-LAG device number | 2 / 2 |
| ED group | 8 / 8 |
| ACL | max number of ingress ACL / 5.25K / IPv4: 26KIPv6: 8K |
| max number of egress ACL | 2048 / IPv4: 2KIPv6: 1K |
| Forwarding table | Jumbo frame length(byte) / 9216 / 13312 |
| Mirroring group | 4 / 8 |
| PBR policy | 1000 / 1000 |
| PBR node | 256 / 256 |
| max number of MAC per switch | 288K / 576K |
| max number of ARP entries IPv4 | 136K / 94K-26 |
| max ND table size for IPv6 | 67690 / 78584 |
| max number of unicast routes IPv4 | 360267 / 762k |
| max number of unicast routes IPv6 | 144179 / 256k |
| IPv4 l2 multicast group | 16K / 8k |
| IPv4 l3 multicast group | 16K / Standard: 4094maximum: 8177 |
| IPv4 multicast routing | 256K / 16K |
| IPv6 l2 multicast group | 8K / 4k |
| IPv6 l3 multicast group | 8K / Standard: 4094maximum: 6832 |
| IPv6 multicast routing | 8K / 8K |
| LAGG group | 1000 / 256 |
| LAGG member per group | 32 / 255 |
| ECMP group | max 4K / max 2K |
| ECMP member per group | 2-128 / 2-128 |
| VRF | 4095 / 4k |
| Interface | Loopback interface number / 1K / 1K |
| L3 sub interface number | 500 / 4096 |
| SVI interface number | 4094 / 4094 |
| SVI second ip | 1K / 1K |
| VxLAN AC number | 16K / 8K |
| VxLAN number | 16K / 8K |
| VxLAN tunnel number | 9K / 4K |
| VSI interface number | 8K / 8K |
| IPv4 tunnel number | 2K / 4K |
| IPv6 tunnel number | 2K / 2K |
| VLAN number | 4096 / 4096 |
| Performance | RIB / 1M / 1M |
| MSTP instance | 64 / 64 |
| PVST instance | 510 / 126 |
| PVST logical port number | 2000 / 2000 |
| VRRP VRID | 255 / 255 |
| VRRP group | 256 / 256 |
| NQA group | 32 / 32 |
| Static table | static mac-address / 20k / 48k |
| static ARP | 136K / 94k-26 |
| static ND | 1K / 1K |
| Static table | static IPv4 routing table / 360267 / 762k |
| static IPv6 routing table | 144179 / 256k |
| Catalog Description | |
| Description | H3C S12504G-AF,Combined Configuration,(Chassis+M1SUP04T2*2+M1SFT04F2*4+M2TGS48TD2+AC2400*2+FAN*2) |
| Key Features | |
| Feature 1 | Advanced CLOS+ multi-grade multi-plane switching architecture: CLOS+ multi-grade multi-plane architecture, midplane free design, providing continuous bandwidth upgrade capability, improve system bandwidth and evolution capabilities, and the capacity of the whole machine can be smoothly expanded. Supports 48-port 10G, 36-port 40GE/ 100GE interfaces and can |
| Feature 2 | Green: Intelligent EMS engine system - Provides smart power management that supports sequential power-on and power-off and device status check. Sequential power-on and power-off reduces power impulse and electromagnetic radiation, and increases the lifetime of the device. Additionally, device status checks can isolate faulty and idle cards to reduce power |
| Feature 3 | H3C S12504G-AF,Combined Configuration,(Chassis+M1SUP04T2*2+M1SFT04F2*4+M2TGS48TD2+AC2400*2+FAN*2) |
| Feature 4 | Part of the H3C S12500 Series Switches family |
| Feature 5 | Suitable for ITMall project quotation and compatibility review |
| Product Identity | |
| Brand | H3C |
| Series | H3C S12500 Series Switches |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the MPU console port specification for LS-Z+M4+A-1?
What is the max ND table size for IPv6 specification for LS-Z+M4+A-1?
What is the MPU slots specification for LS-Z+M4+A-1?
What is the Maximum power consumption specification for LS-Z+M4+A-1?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?