| SSD Support for WAVE Platforms (WAAS 5.2+) |
| WAVE-294-K9 | 200-GB HDD, Quantity of Per Appliance: 1 |
| WAVE-294-SSD-K9 | 200-GB SSD, Quantity of Per Appliance: 1 |
| WAVE-594-K9 | 500-GB HDD or 400-GB SSD, Quantity of Per Appliance: 1 or 2 (optional) |
| WAVE-694-K9 | 600-GB SSD, Quantity of Per Appliance: 1 or 2 (optional) |
| WAVE-8541-K9 | 600-GB HDD or 600-GB SSD, Quantity of Per Appliance: 8 |
| WAVE Appliances Features |
| Cisco WAVE 294 (WAVE-294-K9 or WAVE-294-SSD-K9) | Excellent for edge deployments at small branch and remote offices; Supports up to 200 TCP connections (upgradable to 400); Offers 250-GB HDD and 200-GB SSD data storage options; Has 2 onboard Gigabit Ethernet ports; Provides a 4-port inline I/O module (IOM) bundled by default, with an optional upgrade to an 8-port inline IOM |
| Cisco WAVE 594 (WAVE-594-K9) | Excellent for edge deployments at small and medium-sized branch offices; Supports up to 750 TCP connections (upgradable to 1300); Offers 500-GB HDD and 400-GB SSD data storage options (with an optional second HDD or SSD for RAID 1 redundancy); Has 2 onboard Gigabit Ethernet ports; Provides 4-port Gigabit Ethernet copper inline, 8-port Gigabit Ethernet copper inline, or 4-port Gigabit Ethernet SX fiber; Offers optional second power supply for 1 + 1 redundancy |
| Cisco WAVE 694 (WAVE-694-K9) | Excellent for edge deployments at large enterprise branch offices; Excellent for core deployments at small data centers; Supports up to 2500 TCP connections (upgradable to 6000); Offers 600-GB HDD data storage with RAID 1 redundancy; Has 2 onboard Gigabit Ethernet ports; Offers optional 4-port Gigabit Ethernet copper inline, 8-port Gigabit Ethernet copper inline, or 4-port Gigabit Ethernet SX fiber inline; Offers optional second power supply for 1 + 1 redundancy |
| Cisco WAVE 7541 (WAVE-7541-K9) | Excellent for core deployments at medium-sized data centers and large enterprise branch offices; Supports up to 18,000 TCP connections; Offers 2.2-TB HDD data storage with RAID 5 redundancy; Has 2 onboard Gigabit Ethernet ports; Offers optional 8-port Gigabit Ethernet copper inline, 4-port Gigabit Ethernet SX fiber inline, or 2-port 10 Gigabit Ethernet Enhanced Small Form-Factor Pluggable (SFP+) |
| Cisco WAVE 7571 (WAVE-7571-K9) | Excellent for core deployments at large data centers; Supports 60,000 TCP connections; Offers 3.2-TB HDD data storage with RAID 5 redundancy; Has 2 onboard Gigabit Ethernet ports; Offers optional 8-port Gigabit Ethernet copper inline, 4-port Gigabit Ethernet SX fiber inline, or 2-port 10 Gigabit Ethernet SFP+ |
| Cisco WAVE 8541 (WAVE-8541-K9) | Excellent for core deployments at large data centers and for service providers and cloud providers; Supports 150,000 TCP connections; Offers 4.2-TB HDD or SSD data storage with RAID 5 redundancy; Has 2 onboard Gigabit Ethernet ports; Offers optional 8-port Gigabit Ethernet copper inline, 4-port Gigabit Ethernet SX fiber inline, or 2-port 10 Gigabit Ethernet SFP+ |
| I/O Modules for WAVE Appliances |
| 4-port Gigabit Ethernet copper module (WAVE-INLN-GE-4T) | Fail-to-wire capability; Support for inline and WCCP deployments |
| 8-port Gigabit Ethernet copper module (WAVE-INLN-GE-8T) | Fail-to-wire capability; Support for inline and WCCP deployments |
| 4-port Gigabit Ethernet fiber module (WAVE-INLN-GE-4SX) | Fail-to-wire capability; Support for inline and WCCP deployments |
| 2-port 10 Gigabit Ethernet module (WAVE-10GE-2SFP) | Support for SFP+ short-reach (SR) transceivers; Support for WCCP interception only |
| Hardware Specifications |
| DRAM | WAVE 294: 4 to 8 GB; WAVE 594: 8 to 12 GB; WAVE 694: 16 to 24 GB; WAVE 7541: 24 GB; WAVE 7571: 48 GB; WAVE 8541: 96 GB |
| Usable storage | WAVE 294: 250 GB with HDD or 200 GB with SSD; WAVE 594: 500 GB with HDD or 400 GB with SSD; WAVE 694: 600 GB; WAVE 7541: 2.2 TB; WAVE 7571: 3.1 TB; WAVE 8541: 4.2 TB |
| Maximum data storage | WAVE 294: 1 x 250-GB HDD or 1 x 200-GB SSD; WAVE 594: 2 x 500-GB HDD or 400-GB SSD; WAVE 694: 2 x 600-GB HDD; WAVE 7541: 6 x 450-GB HDD; WAVE 7571: 8 x 450-GB HDD; WAVE 8541: 8 x 600-GB HDD or SSD |
| RAID support | WAVE 294: -; WAVE 594 and 694: RAID 1 (optional on WAVE 594); WAVE 7541 and 7571: RAID 5; WAVE 8541: RAID 5 |
| Network interfaces | All platforms: Two 10/100/1000BASE-T |
| Power | WAVE 294: One 400-Watt AC power supply; WAVE 594 and 694: One 450-Watt AC power supply, Redundant power available as an option; WAVE 7541 and 7571: Two 650-Watt AC power supplies, 1 + 1 redundancy, hot-swappable; WAVE 8541: Two 650-Watt AC power supplies, 1 + 1 redundancy, hot-swappable |
| Fan | WAVE 294: Five fans; WAVE 594 and 694: Redundant 40-mm fans, hot swappable; WAVE 7541, 7571, 8541: Redundant 40- and 60-mm fans, hot swappable |
| Rack units | WAVE 294 and 594/694: 1 (WAVE 294 can be used as desktop); WAVE 7541 and 8541: 2 |
| I/O module | WAVE 294: 4-port Gigabit Ethernet inline bundled (8-port optional); WAVE 594 and 694: 4-port or 8-port Gigabit Ethernet inline (optional); WAVE 7541, 7571, 8541: 2-port 10 Gigabit Ethernet SFP+, 8-port Gigabit Ethernet inline, or 4-port Gigabit Ethernet inline fiber (optional) |
| Console | All platforms: USB, mini-USB, and RJ-45 serial console, auto-detect |
| Height | WAVE 294, 594, 694: 1.69 in. (42 mm); WAVE 7541, 8571, 8541: 3.42 in. (87 mm) |
| Width | All platforms: 16.89 in. (429 mm) |
| Depth | WAVE 294: 14.55 in. (370 mm); WAVE 594 and 694: 20.33 in. (516 mm) includes power-supply handles; WAVE 7541, 7571, 8541: 24.88 in. (632 mm) includes power supply handles |
| Maximum weight | WAVE 294: 16.40 lbs (7.44 kg); WAVE 594 and 694: 22.51 lbs (10.21 kg); WAVE 7541, 7571, 8541: 47.66 lbs (21.62 kg) |
| Shipping dimensions | WAVE 294: 21.69 x 19.88 x 7.75 in. (55 x 50.5 x 19.7 cm); WAVE 594/694: 26.50 x 21.69 x 7.75 in. (67.3 x 55 x 19.7 cm); WAVE 7541, 7571, 8541: 30.75 x 21.69 x 10.19 in. (78 x 55 x 25.9 cm) |
| Shipping weight | WAVE 294: 22.0 lbs (10.0 kg); WAVE 594/694: 28.50 lbs (12.93 kg); WAVE 7541, 7571, 8541: 53.0 lbs (24.0 kg) |
| Operating Specifications |
| Universal input range line voltage | All platforms: 90 to 132 VAC, 180 to 264 VAC |
| Operating temperature | All platforms: 32 to 104°F (0 to 40°C) |
| Non-operating temperature | All platforms: -22 to 140°F (-30 to 60°C) |
| Humidity operating | All platforms: 10 to 90% RH (noncondensing) |
| Humidity non-operating | All platforms: 5 to 95% RH (noncondensing) |
| Altitude operating | All platforms: 10,000 ft (3050 m) |
| Altitude non-operating | All platforms: 15,000 ft (4572 m) |
| Regulatory Compliance |
| Compliance | CE marking |
| EMC | 47 CFR Part 15 Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN 55022 Class A, ICES 003 Class A, VCCI Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, CISPR24, GB9254-2008, KN22 Class A, KN24 (all platforms) |
| Safety | UL 60950-1 Second Edition, 21 CFR 1040, CSA22.2-No. 60950-1 Second Edition, IEC/EN 60950-1 Second Edition, AS/NZS 60950, GB4943-1995 (all platforms) |
| WAAS Features and Benefits |
| WAN Optimization Features | Transport flow optimization (TFO); Data redundancy elimination (DRE) up to 100:1; Adaptive persistent session-based compression up to 5:1 |
| Application Acceleration | Protocol acceleration (read-ahead, prediction, etc.); Optimizers for SMB, MAPI/EMAPI, HTTP/HTTPS, NFS, ICA, print services; Content prepositioning |
| Deployment Ease | Network/client/server transparency; Automatic peer discovery; Quickstart wizard; EZ Config for ISRs; Management/monitoring tools |
| Cloud Deployment | vWAAS agility; AppNav-XE on ASR1000/ISR/CSR; VRF preservation, flow affinity, HA; SaaS acceleration |
| Video Delivery | Edge-stream splitting; VoD prepositioning; Server offload up to 10x |
| Management | WAAS Central Manager HTML5; Stats, SNMPv2c/3, SMTP, syslog; Centralized upgrades; XML API |
| Scalability/HA | WCCP N+1, inline fail-to-wire; Redundant links; AppNav virtualization |
| Security | 256-bit AES encryption; Firewall integration; SSL preservation; AAA/RBAC |