| Key Specifications |
|---|
| Dimensions (W x H x D) | 440mm x 886mm x 660mm (20RU) |
| Weight (Kg) | < 143kg |
| Supervisor Engine Module Slot Count | 2 |
| Total Power Consumption (W) | <2252W |
| Service Module Slot Count | 8 (vertical slots) |
| Fabric Module Slot Count | 4 |
| Product Specifications |
|---|
| Dimensions (W x H x D) | 440mm x 886mm x 660mm (20RU) |
| Weight (Kg) | < 143kg |
| Supervisor Engine Module Slot Count | 2 |
| Total Power Consumption (W) | <2252W |
| Service Module Slot Count | 8 (vertical slots) |
| Fabric Module Slot Count | 4 |
| Product Specifications |
|---|
| Supervisor Engine Module Slot Count | 2 |
| Service Module Slot Count | 8 (vertical slots) |
| Fabric Module Slot Count | 4 |
| Redundancy design | Supervisor Engine Module, Fabric Module, Power Supply, Fan |
| Dimensions (W x H x D) | 440mm x 886mm x 660mm (20RU) |
| Weight (Kg) | < 143kg |
| Total Power Consumption (W) | <2252W |
| Ambient temperature | Operating: 0~45℃; Non-operating: -40~70℃ |
| AAA Services | Portal Authentication, RADIUS Authentication, HWTACACS Authentication, PKI/CA (X.509 format)Authentication, domain authentication, CHAP authentication, PAP authentication |
| Virus Protection | Detection based on virus characteristics Support manual and automatic upgrade of virus database Message stream processing mode Support HTTP, FTP, SMTP, POP3 protocols Supported virus types: Backdoor, Email-Worm, IM-Worm, P2P-Worm, Trojan, Ad Ware, Virus, etc. Support virus logs and reports |
| Deep Intrusion Prevention | Supports defense against hacker attacks, worms/viruses, Trojan horses, malicious code, spyware/adware, DoS/DDoS often Supports defense against buffer overflow, SQL injection, IDS/IPS escape, etc. Supports classification (based on attack type, target machine system) and grading (in four levels: high, medium, low, and prompt) of attack signature libraries Supports manual Supports manual and automatic upgrade (TFTP and HTTP) of the attack signature library. Supports the identification and control of P2P/IM such as BT. |
| Email/Web/Application-Layer Filtering | Email FilteringSMTP Email Address Filtering Email Header Filtering Email Content Filtering Email Attachment Filtering Web FilteringHTTP URL FilteringHTTP Content Filtering Application Layer Filtering Java Blocking ActiveX BlockingSQL Injection Attack Prevention |
| VPN | L2TP VPN、IPSec VPN、GRE VPN、MPLS VPN、SSL VPN |
| IPv6 | IPv6 Stateful Firewall, IPv6 Inter-Domain Policies, IPv6 Attack Prevention, IPv6 Connection Limits, IPv6 Protocols: ICMPv6, PMTU, Ping6, DNS6, TraceRT6, Telnet6, DHCPv6 Client, DHCPv6 Relay, etc. IPv6 Routing: RIPng, OSPFv3, BGP4+, static routing, policy-based routing, PIM-SM, PIM-DM, etc. IPv6 Transition Technologies: NAT-PT, IPv6 Tunnel, NAT64 (DNS64), DS-LITE, etc. |
| Environmental Protection and Certification | Supports Europe's strict RoHS environmental certification |
| Catalog Description |
|---|
| Description | H3C SecPath M9016-V Multiservice Security Gateway Appliance |
| Key Features |
|---|
| Feature 1 | High-performance hardware and software processing platform Adopts a fully distributed architecture that separates control, service, and data, and separates the control engine, switching engine, service engine, and interface unit hardware to decouple key system components and improve system reliability. |
| Feature 2 | A dedicated hardware switching engine supports non-blocking processing and forwarding of high-performance security services. A dedicated high-performance control engine enables unified system configuration management and security clustering. The security service engine utilizes multi-core high-performance processors, delivering industry-leading high-speed processing performance for security services on a single board. |
| Feature 3 | A single hardware board provides comprehensive security protection from Layer 2 to Layer 7, including firewall, NAT, load balancing (LB), intrusion prevention system (IPS), antivirus (AV), access control group (ACG), and VPN. |
| Feature 4 | Built-in professional-grade hardware TCAM ensures high-speed lookup of large-capacity policy table entries. The built-in modular software system supports multi-process scheduling and isolation of the runtime environments between processes, ensuring that a failure in a single process does not affect the rest of the system, thereby enhancing system reliability. |
| Feature 5 | Supports permission management, allowing users to define read and write permissions based on features, command lines, system resources, and web management levels, thereby enhancing system security. |
| Ordering Information |
|---|
| Supervisor Engine Module | |
| 0231AERW | NSQM1SUPD0; Type: Supervisor Engine Module |
| Fabric Module | |
| 0231AERX | NSQM1FAB08E0; Type: Fabric Module |
| Configuration Options | |
| 0231A4PY | NS-SSD-480G-SATA-SFF |
| 0231A3P3 | NSQM1FWDFG0 |
| 0231A4EQ | NSQM1NATDFGA0; H3C Sec Path M9000, Sec Blade IV NAT Amodule |
| 0231A4ER | NSQM1NATDFGB0; H3C Sec Path M9000, Sec Blade IV NAT Bmodule |
| 0231A4Q1 | NSQM1FWDFGB0 |
| 0231A4Q2 | NSQM1FWDFGC0 |
| 0231A4Q3 | NSQM1FWDFGA1 |
| 0231A4Q4 | NSQM1FWDFGB1 |
| 0231A4Q5 | NSQM1FWDFGC1 |
| 0231A4Q6 | NSQM1FWDFGD1 |
| SFP+ 10GbE port | |
| 02312173 | SFP-GE-LH80-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231A563 | SFP-GE-LX-SM1310-A; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231A962 | SFP-GE-LX-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 02312170 | SFP-GE-LH40-SM1310; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A963 | SFP-GE-LH40-SM1310-D; Optical transceiver - SFP-GE single-mode module (1310nm, 40km, LC); Type: SFP+ 10GbE port |
| 02312172 | SFP-GE-LH40-SM1550; Optical transceiver - SFP-GE single-mode module (1550nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A964 | SFP-GE-LH80-SM1550-D; Optical transceiver - SFP-GE single-mode module (1550nm, 80km, LC); Type: SFP+ 10GbE port |
| 0231A562 | SFP-GE-SX-MM850-A; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP+ 10GbE port |
| 0231A961 | SFP-GE-SX-MM850-D; Optical transceiver - SFP-GE multimode module (850nm, 0.55km, LC); Type: SFP+ 10GbE port |
| 0231A085 | SFP-GE-T; SFP GE copper transceiver (100m, RJ45); Type: SFP+ 10GbE port |
| 0231A960 | SFP-GE-T-D; SFP GE copper transceiver (100m, RJ45); Type: SFP+ 10GbE port |
| 0231A0A8 | SFP-XG-LX-SM1310; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231A1RQ | SFP-XG-LX-SM1310-D; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231A2L3 | SFP-XG-LX-SM1310-E; SFP+ 10GbE optical transceiver (1310nm, 10km, LC); Type: SFP+ 10GbE port |
| 0231A0SP | SFP-XG-LH40-SM1550; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A1RR | SFP-XG-LH40-SM1550-D; SFP+ 10GbE optical transceiver (1550nm, 40km, LC); Type: SFP+ 10GbE port |
| 0231A0A6 | SFP-XG-SX-MM850-A; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP+ 10GbE port |
| 0231A1RP | SFP-XG-SX-MM850-D; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP+ 10GbE port |
| 0231A2L4 | SFP-XG-SX-MM850-E; SFP+ 10GbE optical transceiver (850nm, 300m, LC); Type: SFP+ 10GbE port |
| QSFP+ port | |
| 0231A2E4 | QSFP-40G-LR4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 10km, LR4, LC); Type: QSFP+ port |
| 0231A4Q7 | QSFP-40G-BIDI-SR-MM850; QSFP+ 40G BIDI optical transceiver (850nm, 100m, SR); Type: QSFP+ port |
| 0231A4PB | QSFP-40G-LR4L-WDM1300; QSFP+ 40G optical transceiver (1310nm, 2km, LR4L, LC); Type: QSFP+ port |
| 0231A4UG | QSFP-40G-ER4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 40km, ER4, LC); Type: QSFP+ port |
| 0231A2NF | QSFP-40G-SR4-MM850; Type: QSFP+ port |
| 0231A2KL | QSFP-40G-CSR4-MM850; Type: QSFP+ port |
| Configuration Options | |
| 0231A5X1 | NSQM1TGS32QSSG0 |
| 0231A6NT | NSQM1MBFEA0 |
| QSFP28 port | |
| 0231A4B1 | QSFP-100G-SR4-MM850; 100G QSFP28 optical transceiver (850nm, 100m OM4, SR4, MPO); Type: QSFP28 port |
| 0231A5H6 | 100G QSFP28 optical transceiver (850nm, 100m OM4, SWDM4, LC); Type: QSFP28 port |
| 0231A5LL | QSFP-100G-LR4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 2km, LR4L, CWDM4, LC); Type: QSFP28 port |
| 0231A4UF | QSFP-100G-LR4-WDM1300; 100G QSFP28 optical transceiver (1310nm, 10km, LR4, WDM, LC); Type: QSFP28 port |
| 0231ABS7 | QSFP-100G-ER4L-WDM1300; 100G QSFP28 optical transceiver (1310nm, 40km, ER4L, WDM, LC); Type: QSFP28 port |
| 0231AFJB | QSFP-100G-ER4-WDM1300; 100G QSFP28 optical transceiver (1300nm, 40km, ER4, WDM, LC); Type: QSFP28 port |
| Configuration Options | |
| 0231AFH6 | NSQM1CGQ6SH0 |
| 0231A6P2 | NSQM2QG2GP40 |
| QSFP+ port | |
| 0231AJHT | QSFP-40G-LX4-WDM1300; QSFP+ 40G optical transceiver (1310nm, 150m, OM3, LX4); Type: QSFP+ port |
| Configuration Options | |
| 0231A6P1 | NSQM2QG2TG8GP40 |
| 0231A6NY | NSQM2QG4GP40 |
| 0231A6P3 | NSQM2TG8GP40 |
| 0231A6NW | NSQM1CGQ20 |
| 0231A6P0 | NSQM2TG16GP40 |
| Power Supply Module | |
| 0231AHL9 | PSR2500B-12AHD-F-V; Type: Power Supply Module |
| 0231A5XF | NSQM1AC2500; AC Power Supply Module, 2500W; Type: Power Supply Module |
| 0231A5XG | NSQM1DC2400; DC Power Supply Module, 2400W; Type: Power Supply Module |
| cable | |
| 04042967 | CAB-CON-1.8m; Type: cable |
| 0404A1EE | CAB-Console-1.8m-W31R; Console Cable-1.8m (RJ45P) (UL2725(3C28AWG)) (USB AP); Type: cable |
| Configuration Options | |
| 3130A1RR | LIS-M9000-IPS-1Y |
| 3130A1RS | LIS-M9000-IPS-3Y |
| 3130A1RT | LIS-M9000-ACG-1Y |
| 3130A1RU | LIS-M9000-ACG-3Y |
| 3130A1RW | LIS-M9000-SSL-200 |
| 3130A1RX | LIS-M9000-SSL-500 |
| 3130A1RY | LIS-M9000-SSL-1000 |
| 3130A1S0 | LIS-M9000-SSL-3000 |
| 3130A1TR | LIS-M9000-AV-1Y |
| 3130A1TS | LIS-M9000-AV-3Y |
| 3130A381 | LIS-M9000-URL-3Y |
| 3130A382 | LIS-M9000-URL-1Y |
| 3130A3QD | LIS-M9000-WAF-1Y |
| 3130A3QE | LIS-M9000-WAF-3Y |
| 3130A48B | LIS-M9000-TI-3Y |
| 3130A48C | LIS-M9000-TI-1Y |
| IMC-SSL License Certificate | |
| 3130A2WB | LIS-IMC7-SVM9KB-500; Type: IMC-SSL License Certificate |
| 3130A2WA | LIS-IMC7-SVM9KA-200; Type: IMC-SSL License Certificate |
| 3130A2WY | LIS-IMC7-SVM9KC-1K; Type: IMC-SSL License Certificate |
| 3130A2WC | LIS-IMC7-SVM9KD-3K; Type: IMC-SSL License Certificate |
| Configuration Options | |
| 3130A4S4 | LIS-Seer Engine-Sec-CDC |
| Base Configuration | |
| 0235A2MR | NS-Sec Path M9016-V |
| Product Identity |
|---|
| Brand | H3C |
| Series | H3C M9000 Series Products |