Product Overview
The Juniper QFX10008-SF is a high-performance network component designed for the QFX10008 series.

Our CCIE certified engineers can help you verify compatibility.
Global logistics network aiming for same-day handover.
Every unit undergoes rigorous 38-point inspection test.
Trusted by enterprise clients across 6 continents.
Certified network engineers ready to assist with configuration.
The Juniper QFX10008-SF is a high-performance network component designed for the QFX10008 series.
| QFX10008-BASE — Overview | |
|---|---|
| Full Product Name | QFX10008 Modular Ethernet Switch |
| OS Supported | Junos OS |
| QFX10008-BASE — Chassis | |
| Fixed/Modular Chassis? | Modular |
| Form Factor | 13 U |
| Chassis Height | 22.6 in / 57.404 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 32 in / 81.28 cm |
| Chassis Weight (Spare) | 145.2 lb / 65.85 kg |
| Chassis Weight (As Shipped) | 280 lb / 126.98 kg |
| Chassis Weight (Fully Loaded With All Components) | 493 lb / 224 kg |
| QFX10008-BASE — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Tray Model Number | QFX10008-FAN |
| Fan Tray Count | 2 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y |
| Fan Tray Controller Model Number | QFX10008-FAN-CTRL |
| Fan Tray Controller Count | 2 |
| Fan Tray Controller Hot-Removable And Hot-Insertable? | Y |
| QFX10008-BASE — Environmental Specifications | |
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX10008-BASE — Performance (General) | |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| QFX10008-BASE — Performance (Routing/Switching) | |
| Throughput | 48000 Gbps |
| Forwarding Capacity | 16 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 2000 |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Unicast Host Routes (Thousands) | 2000 |
| IPv6 Multicast Routes (Thousands) | 128 |
| Filter Terms | 64000 |
| Policers | 8000 |
| ARP Entries (Tunnel Mode) (Thousands) | 510 |
| LAGs Count | 1000 |
| MAC Addresses Per System (Thousands) | 1000 |
| MPLS IPv4 L3 VPNs | 4096 |
| VLAN IDs Count | 4093 |
| VXLAN Tunnels | 1000 |
| Jumbo Frame | 9216 bytes |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| QFX10008-BASE — Power System | |
| PSU Count | 3 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | QFX10000-PWR-AC |
| Grounding Cable Lug Type | Panduit LCD6-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 6 AWG |
| QFX10008-BASE — Routing/Switching Hardware | |
| RE Model Number | QFX10000-RE |
| RE Count | 1 |
| SFB Model Number | QFX10008-SF |
| SFB Count | 5 |
| SFB Hot-Pluggable? | Y |
| Line Card Slots | 8 |
| QFX10008-BASE-H — Overview | |
| Full Product Name | QFX10008 Modular Ethernet Switch |
| OS Supported | Junos OS |
| QFX10008-BASE-H — Chassis | |
| Fixed/Modular Chassis? | Modular |
| Form Factor | 13 U |
| Chassis Height | 22.6 in / 57.404 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 32 in / 81.28 cm |
| Chassis Weight (Spare) | 145.2 lb / 65.85 kg |
| Chassis Weight (Fully Loaded With All Components) | 493 lb / 224 kg |
| QFX10008-BASE-H — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Tray Model Number | QFX10008-FAN |
| Fan Tray Count | 2 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y |
| Fan Tray Controller Model Number | QFX10008-FAN-CTRL |
| Fan Tray Controller Count | 2 |
| Fan Tray Controller Hot-Removable And Hot-Insertable? | Y |
| QFX10008-BASE-H — Environmental Specifications | |
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX10008-BASE-H — Performance (General) | |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| QFX10008-BASE-H — Performance (Routing/Switching) | |
| Throughput | 48000 Gbps |
| Forwarding Capacity | 16 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 2000 |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Unicast Host Routes (Thousands) | 2000 |
| IPv6 Multicast Routes (Thousands) | 128 |
| Filter Terms | 64000 |
| Policers | 8000 |
| ARP Entries (Tunnel Mode) (Thousands) | 510 |
| LAGs Count | 1000 |
| MAC Addresses Per System (Thousands) | 1000 |
| MPLS IPv4 L3 VPNs | 4096 |
| VLAN IDs Count | 4093 |
| VXLAN Tunnels | 1000 |
| Jumbo Frame | 9216 bytes |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| QFX10008-BASE-H — Power System | |
| PSU Count | 3 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| HVDC PSU Model Number | JNP10K-PWR-AC2 |
| Grounding Cable Lug Type | Panduit LCD6-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 6 AWG |
| QFX10008-BASE-H — Routing/Switching Hardware | |
| RE Model Number | QFX10000-RE |
| RE Count | 1 |
| SFB Model Number | QFX10008-SF |
| SFB Count | 5 |
| SFB Hot-Pluggable? | Y |
| Line Card Slots | 8 |
| QFX10008-REDUND — Overview | |
| Full Product Name | QFX10008 Modular Ethernet Switch |
| OS Supported | Junos OS |
| QFX10008-REDUND — Chassis | |
| Fixed/Modular Chassis? | Modular |
| Form Factor | 13 U |
| Chassis Height | 22.6 in / 57.404 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 32 in / 81.28 cm |
| Chassis Weight (Spare) | 145.2 lb / 65.85 kg |
| Chassis Weight (As Shipped) | 322 lb / 146.03 kg |
| Chassis Weight (Fully Loaded With All Components) | 493 lb / 224 kg |
| QFX10008-REDUND — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Tray Model Number | QFX10008-FAN |
| Fan Tray Count | 2 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y |
| Fan Tray Controller Model Number | QFX10008-FAN-CTRL |
| Fan Tray Controller Count | 2 |
| Fan Tray Controller Hot-Removable And Hot-Insertable? | Y |
| QFX10008-REDUND — Environmental Specifications | |
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX10008-REDUND — Performance (General) | |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| QFX10008-REDUND — Performance (Routing/Switching) | |
| Throughput | 48000 Gbps |
| Forwarding Capacity | 16 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 2000 |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Unicast Host Routes (Thousands) | 2000 |
| IPv6 Multicast Routes (Thousands) | 128 |
| Filter Terms | 64000 |
| Policers | 8000 |
| ARP Entries (Tunnel Mode) (Thousands) | 510 |
| LAGs Count | 1000 |
| MAC Addresses Per System (Thousands) | 1000 |
| MPLS IPv4 L3 VPNs | 4096 |
| VLAN IDs Count | 4093 |
| VXLAN Tunnels | 1000 |
| Jumbo Frame | 9216 bytes |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| QFX10008-REDUND — Power System | |
| PSU Count | 6 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | QFX10000-PWR-AC |
| Grounding Cable Lug Type | Panduit LCD6-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 6 AWG |
| QFX10008-REDUND — Routing/Switching Hardware | |
| RE Model Number | QFX10000-RE |
| RE Count | 2 |
| RE Hot-Pluggable? | Primary |
| RE Hot-Removable And Hot-Insertable? | Backup |
| SFB Model Number | QFX10008-SF |
| SFB Count | 6 |
| SFB Hot-Pluggable? | Y |
| Line Card Slots | 8 |
| QFX10008-REDUND-DC — Overview | |
| Full Product Name | QFX10008 Modular Ethernet Switch |
| OS Supported | Junos OS |
| QFX10008-REDUND-DC — Chassis | |
| Fixed/Modular Chassis? | Modular |
| Form Factor | 13 U |
| Chassis Height | 22.6 in / 57.404 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 32 in / 81.28 cm |
| Chassis Weight (Spare) | 145.2 lb / 65.85 kg |
| Chassis Weight (As Shipped) | 319 lb / 144.67 kg |
| Chassis Weight (Fully Loaded With All Components) | 493 lb / 224 kg |
| QFX10008-REDUND-DC — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Tray Model Number | QFX10008-FAN |
| Fan Tray Count | 2 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y |
| Fan Tray Controller Model Number | QFX10008-FAN-CTRL |
| Fan Tray Controller Count | 2 |
| Fan Tray Controller Hot-Removable And Hot-Insertable? | Y |
| QFX10008-REDUND-DC — Environmental Specifications | |
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX10008-REDUND-DC — Performance (General) | |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| QFX10008-REDUND-DC — Performance (Routing/Switching) | |
| Throughput | 48000 Gbps |
| Forwarding Capacity | 16 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 2000 |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Unicast Host Routes (Thousands) | 2000 |
| IPv6 Multicast Routes (Thousands) | 128 |
| Filter Terms | 64000 |
| Policers | 8000 |
| ARP Entries (Tunnel Mode) (Thousands) | 510 |
| LAGs Count | 1000 |
| MAC Addresses Per System (Thousands) | 1000 |
| MPLS IPv4 L3 VPNs | 4096 |
| VLAN IDs Count | 4093 |
| VXLAN Tunnels | 1000 |
| Jumbo Frame | 9216 bytes |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| QFX10008-REDUND-DC — Power System | |
| PSU Count | 6 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| DC PSU Model Number | QFX10000-PWR-DC |
| Grounding Cable Lug Type | Panduit LCD6-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 6 AWG |
| QFX10008-REDUND-DC — Routing/Switching Hardware | |
| RE Model Number | QFX10000-RE |
| RE Count | 2 |
| RE Hot-Pluggable? | Primary |
| RE Hot-Removable And Hot-Insertable? | Backup |
| SFB Model Number | QFX10008-SF |
| SFB Count | 6 |
| SFB Hot-Pluggable? | Y |
| Line Card Slots | 8 |
| QFX10008-REDUND-H — Overview | |
| Full Product Name | QFX10008 Modular Ethernet Switch |
| OS Supported | Junos OS |
| QFX10008-REDUND-H — Chassis | |
| Fixed/Modular Chassis? | Modular |
| Form Factor | 13 U |
| Chassis Height | 22.6 in / 57.404 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 32 in / 81.28 cm |
| Chassis Weight (Spare) | 145.2 lb / 65.85 kg |
| Chassis Weight (Fully Loaded With All Components) | 493 lb / 224 kg |
| QFX10008-REDUND-H — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Fan Tray Model Number | QFX10008-FAN |
| Fan Tray Count | 2 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y |
| Fan Tray Controller Model Number | QFX10008-FAN-CTRL |
| Fan Tray Controller Count | 2 |
| Fan Tray Controller Hot-Removable And Hot-Insertable? | Y |
| QFX10008-REDUND-H — Environmental Specifications | |
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX10008-REDUND-H — Performance (General) | |
| Route Table Size (FIB) (IPv4) (Thousands) | 2000 |
| Route Table Size (FIB) (IPv6) (Thousands) | 2000 |
| QFX10008-REDUND-H — Performance (Routing/Switching) | |
| Throughput | 48000 Gbps |
| Forwarding Capacity | 16 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 2000 |
| IPv4 Multicast Routes (Thousands) | 128 |
| IPv6 Unicast Host Routes (Thousands) | 2000 |
| IPv6 Multicast Routes (Thousands) | 128 |
| Filter Terms | 64000 |
| Policers | 8000 |
| ARP Entries (Tunnel Mode) (Thousands) | 510 |
| LAGs Count | 1000 |
| MAC Addresses Per System (Thousands) | 1000 |
| MPLS IPv4 L3 VPNs | 4096 |
| VLAN IDs Count | 4093 |
| VXLAN Tunnels | 1000 |
| Jumbo Frame | 9216 bytes |
| Output Queues Per Port | 8 |
| Firewall Filters | 8000 |
| QFX10008-REDUND-H — Power System | |
| PSU Count | 6 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| HVDC PSU Model Number | JNP10K-PWR-AC2 |
| Grounding Cable Lug Type | Panduit LCD6-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 6 AWG |
| QFX10008-REDUND-H — Routing/Switching Hardware | |
| RE Model Number | QFX10000-RE |
| RE Count | 2 |
| RE Hot-Pluggable? | Primary |
| RE Hot-Removable And Hot-Insertable? | Backup |
| SFB Model Number | QFX10008-SF |
| SFB Count | 6 |
| SFB Hot-Pluggable? | Y |
| Line Card Slots | 8 |
Very fast delivery.
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
Still have questions?