| Overview |
|---|
| Full Product Name | QFX5200 Switch |
| OS Supported | Junos OS |
| Chassis |
|---|
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 1 U |
| Chassis Height | 1.72 in / 4.3688 cm |
| Chassis Width | 17.36 in / 44.0944 cm |
| Chassis Depth | 20.48 in / 52.0192 cm |
| Chassis Weight (As Shipped) | 23.8 lb / 10.79 kg |
| Cooling System |
|---|
| Airflow Direction | Front-to-back |
| Airflow Volume | 130 CFM |
| AFO/AFI? | AFO |
| Fan Module Model Number | QFX5200-32C-FANAFO |
| Fan Module Count | 5 |
| Fan Module Redundancy | 4+1 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| Environmental Specifications |
|---|
| Operating Altitude | 10000 ft / 3048 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 95% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| Built-in Network Ports |
|---|
| QSFP28 Port Count | 32 |
| QSFP28 Port Channelization | Y |
| Other Port Configuration |
|---|
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| Management Port 2 Count | 2 |
| Management Port 2 Type | SFP |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| Timing Port | Y |
| Performance (Routing/Switching) |
|---|
| Throughput (Bidirectional) | 6400 Gbps |
| Throughput (Unidirectional) | 3200 Gbps |
| Forwarding Capacity | 3.2 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 104 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 128 |
| IPv4 Multicast Routes (Thousands) | 52 |
| IPv6 Unicast Host Routes (Thousands) | 52 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 98 |
| IPv6 Multicast Routes (Thousands) | 28 |
| Firewall Filters (Ingress) | 768 |
| Firewall Filters (Egress) | 1024 |
| ARP Entries (Thousands) | 32 |
| MPLS Labels (Thousands) | 16 |
| MSTP Instances | 64 |
| VSTP Instances | 253 |
| LAGs Count | 128 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 136 |
| MPLS IPv4 L3 VPNs (Premium Services License) | 2048 |
| Number Of FCoE VLANs/FC Virtual Fabrics | 4095 |
| Maximum Mirroring Sessions | 4 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4096 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 16 MB |
| Performance (Security) |
|---|
| GRE Tunnels | 1024 |
| Processor |
|---|
| CPU | 1.8 GHz quad-core Intel CPU |
| DRAM | 16 GB |
| Storage |
|---|
| Internal Storage Size | 64 GB |
| Internal Storage Type | SSD |
| Power System |
|---|
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JPSU-850W-AC-AFO |
| AC Max Power Consumption | 312 W |
| AC Average Power Consumption | 184 W |
| Grounding Cable Lug Type | Panduit LCD10-10A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 14 AWG |
| Supported Transceivers |
|---|
| CTP-SFP-1GE-LX | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module, CTP1000 |
| CTP-SFP-1GE-SX | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module, CTP1000 |
| CTP-SFP-1GE-T | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module (uses Cat 5 cable) |
| EX-QSFP-40GE-DAC-50CM | QSFP+ 40 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable) for 50cm Transmission |
| EX-SFP-10GE-DAC-1M | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 1M |
| EX-SFP-10GE-SR | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) SR Optics |
| EX-SFP-1GE-LX | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optics |
| EX-SFP-1GE-SX | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optics |
| EX-SFP-1GE-SX-ET | SFP, 1000Base-SX Gigabit Ethernet, Extended Temperature Range Optics |
| EX-SFP-1GE-T | Small Form Factor Pluggable 10/100/1000 Copper Transceiver Module |
| JNP-100G-2X50G-1M | 100G DAC Breakout into 2x50G 1M |
| JNP-100G-2X50G-2M | 100G DAC Breakout into 2x50G 2M |
| JNP-100G-2X50G-3M | 100G DAC Breakout into 2x50G 3M |
| JNP-100G-2X50G-5M | 100G DAC Breakout into 2x50G 5M |
| JNP-100G-4X25G-1M | 100G QSFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 1m |
| JNP-100G-4X25G-3M | 100G QSFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 3m |
| JNP-100G-4X25G-5M | 100G QFP28 to SFP28 4x25G Direct Attach Copper Breakout (twinax copper cable) 5m |
| JNP-100G-AOC-10M | QSFP28 100G active optical cable for 10M |
| JNP-100G-AOC-15M | QSFP28 100G active optical cable for 15M |
| JNP-100G-AOC-1M | QSFP28 100G active optical cable for 1M |
| JNP-100G-AOC-20M | QSFP28 100G active optical cable for 20M |
| JNP-100G-AOC-30M | QSFP28 100G active optical cable for 30M |
| JNP-100G-AOC-3M | QSFP28 100G active optical cable for 3M |
| JNP-100G-AOC-5M | QSFP28 100G active optical cable for 5M |
| JNP-100G-AOC-7M | QSFP28 100G active optical cable for 7M |
| JNP-100G-AOCBO-10M | 100GE-AOC OM3 10m 850nm 70C |
| JNP-100G-AOCBO-15M | 100GE-AOC OM3 15m 850nm 70C |
| JNP-100G-AOCBO-1M | 100GE-AOC OM3 1m 850nm 70C |
| JNP-100G-AOCBO-20M | 100GE-AOC OM3 20m 850nm 70C |
| JNP-100G-AOCBO-30M | 100GE-AOC OM3 30m 850nm 70C |
| JNP-100G-AOCBO-3M | 100GE-AOC OM3 3m 850nm 70C |
| JNP-100G-AOCBO-5M | 100GE-AOC OM3 5m 850nm 70C |
| JNP-100G-AOCBO-7M | 100GE-AOC OM3 7m 850nm 70C |
| JNP-100G-DAC-1M | 100G DAC Twinax Copper Cable 1M |
| JNP-100G-DAC-3M | 100G DAC Twinax Copper Cable 3M |
| JNP-100G-DAC-5M | 100G DAC Twinax Copper Cable 5M |
| JNP-40G-AOC-10M | 40G active optical cable for 10M |
| JNP-40G-AOC-15M | 40G active optical cable for 15M |
| JNP-40G-AOC-1M | 40G active optical cable for 1M |
| JNP-40G-AOC-20M | 40G active optical cable for 20M |
| JNP-40G-AOC-30M | 40G active optical cable for 30M |
| JNP-40G-AOC-3M | 40G active optical cable for 3M |
| JNP-40G-AOC-5M | 40G active optical cable for 5M |
| JNP-40G-AOC-7M | 40G active optical cable for 7M |
| JNP-QSFP-100G-BXSR | 100GBASE-BXSR OM4 100m 850nm 70C |
| JNP-QSFP-100G-CWDM | 100G CWDM4 optics |
| JNP-QSFP-100G-LR4 | QSFP28 100GBase-LR4 Optics for up to 10km transmission over serial SMF |
| JNP-QSFP-100G-PSM4 | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF |
| JNP-QSFP-100G-SR4 | QSFP28 100GBase-SR4 Optics for up to 100m transmission over parallel MMF |
| JNP-QSFP-40G-LR4 | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF |
| JNP-QSFP-40G-LX4 | QSFP+ 40GBASE-LX4 40 Gigabit Optics for up to 150m transmission with OM4 over duplex MMF |
| JNP-QSFP-40GE-ER4 | |
| JNP-QSFP-40GE-IR4 | QSFP+ 40GBase-IR4 40 Gigabit Optics for up to 2 km transmission over SMF |
| JNP-QSFP-4X10GE-IR | QSFP+ 40GBASE optics, up to 1.4 km transmission on parallel single mode (4X10GbE long reach up to 1.4 km) |
| JNP-QSFP-4X10GE-LR | QSFP+ 40G breakout into 4x10GBASE LR up to 10km SMF, MPO-12 APC Receptacle |
| JNP-QSFP-AOCBO-10M | 40G active optical breakout cable for 10M |
| JNP-QSFP-AOCBO-1M | 40G active optical breakout cable for 1M |
| JNP-QSFP-AOCBO-3M | 40G active optical breakout cable for 3M |
| JNP-QSFP-AOCBO-5M | 40G active optical breakout cable for 5M |
| JNP-QSFP-AOCBO-7M | 40G active optical breakout cable for 7M |
| JNP-QSFP-DAC-10MA | QSFP+ 40GBase Direct Attach Copper Cable 10-meter,active |
| JNP-QSFP-DAC-5M | QSFP+ 40GBase Direct Attach Copper Cable 5-meter, passive |
| JNP-QSFP-DAC-7MA | QSFP+ 40GBase Direct Attach Copper Cable 7-meter, active |
| JNP-QSFP-DACBO-10M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 10-meter, passive |
| JNP-QSFP-DACBO-5MA | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 5-meter, active |
| JNP-QSFP-DACBO-7MA | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 7-meter, active |
| JNP-QSFPP-40G-BXSR | 40GBASE-BXSR OM3 100m 850nm 70C |
| QFX-QSFP-40G-ESR4 | QSFP+ 40GBase-eSR4 40 Gigabit Optics, 850nm for up to 300m Transmission on MMF |
| QFX-QSFP-40G-SR4 | QSFP+ 40GBase-SR4 40 Gigabit Optics, 850nm for up to 150m transmission on MMF |
| QFX-QSFP-DAC-1M | QSFP+ Cable Assy, 1m, 30AWG, Passive, Programmable ID |
| QFX-QSFP-DAC-3M | QSFP+ Cable Assy, 3m, 30AWG, Passive, Programmable ID |
| QFX-QSFP-DACBO-1M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 1m |
| QFX-QSFP-DACBO-3M | QSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Break out Copper (twinax copper cable) 3m |
| QFX-SFP-10GE-SR | SFP+ 10GBase-SR 10 Gigabit Ethernet Optics, 850nm for up to 300m transmission on MMF |
| QFX-SFP-1GE-LX | SFP 1000Base-LX Gigabit Ethernet Optics, 1310nm for 10km transmission on SMF |
| QFX-SFP-1GE-SX | SFP 1000Base-SX Gigabit Ethernet Optics, 850nm for upto 550m transmission on MMF |
| QFX-SFP-1GE-T | SFP 1000Base-T Copper Transceiver Module for up to 100m transmission |
| QFX-SFP-DAC-1M | SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1m |
| QSFP-100G-4WDM40 | QSFP28 100G 4WDM-40 transceiver |
| QSFP-100G-CWDM-C | QSFP-28, 100G-CWDM4 Transceiver |
| QSFP-100G-CWDM-T2 | |
| QSFP-100G-DR | QSFP28 100GBASE-DR; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 500 m; Standard Temperature (0 through 70°C); Duplex LC connector |
| QSFP-100G-ER4L | QSFP28 100G-ER4 Lite Ethernet only module |
| QSFP-100G-FR | QSFP28 100G-FR/100GBASE-FR1; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 2 km; Standard Temperature (0 through 70°C); Duplex LC connector |
| QSFP-100G-LR | QSFP28 100G-LR/100GBASE-LR1; Media-Side RS (544,514) FEC enabled, Host-side CAUI-4 no FEC; SMF 10 km; Standard Temperature (0 through 70°C); Duplex LC connector |
| QSFP-100G-LR4-C | QSFP-28, 100G-LR4 Transceiver |
| QSFP-100G-LR4-T2 | 100G-LR4 Ethernet only QSFP28 Module T2 |
| QSFP-100G-PSM4-T2 | QSFP28 100G base PSM4 optics for up to 500 m transmission over parallel SMF |
| QSFP-100G-SR4-C | QSFP-28, 100G-SR4 Transceiver |
| QSFP-100G-SR4-T2 | 100G-SR4 Ethernet only QSFP28 Module T2 |
| QSFPP-40G-LR4-C | QSFP+ 40GBase-LR4 40 Gigabit Optics for up to 10km transmission on SMF |
| QSFPP-40G-LX4 | QSFP+ 40GBase-LX4 40 Gigabit Optics, 100m(150m) with OM3(OM4) duplex MMF fiber |
| QSFPP-4X10GE-SR | 40G QSFP+ breakout into 4x10GBASE SR Ethernet module |
| SFP-1G-LX-C | SFP, 1G, SMF 10km and MMF 550m, Extended Temperature (-5 through 70 DegC), Duplex LC connector |
| SFP-1G-SX-C | SFP, 1G, FDDI 220m and OM1 275m/OM2 MMF 550m, Extended Temperature (-10 through 85 DegC), Duplex LC connector |
| SFP-1G-T-C | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module (uses Cat 5 cable) |
| SFP-1GE-LX | GE SFP LX Plug In, Module |
| SFPP-10G-SR-C | SFP+, 10G-SR Transceiver |
| SRX-SFP-10GE-DAC-1M | SFP+ 10 Gigabit Ethernet Direct Attach Copper (Twinax Copper Cable), 1M |
| SRX-SFP-10GE-SR | Small Form Factor Pluggable 10 Gigabit Ethernet (SFP+) SR Optics |
| SRX-SFP-1GE-LX | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module |
| SRX-SFP-1GE-LX-ET | Small Form Factor Pluggable 1000Base-LX Gigabit Ethernet Optic Module - Extended temperature |
| SRX-SFP-1GE-SX | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module |
| SRX-SFP-1GE-SX-ET | Small Form Factor Pluggable 1000Base-SX Gigabit Ethernet Optic Module - Extended temperature |
| SRX-SFP-1GE-T | Small Form Factor Pluggable 1000Base-T Gigabit Ethernet Module |
| Power Supply Modules (PSM) |
|---|
| JPSU-850W-AC-AFI | QFX5100 850 Watt AC PSU, Back to Front Airflow (Part: 740-053351) |
| JPSU-850W-AC-AFO | QFX5100 850 Watt AC PSU, Front to Back airflow (Part: 740-053352) |
| JPSU-850W-DC-AFI | QFX5100 850 Watt DC PSU, Back to Front Airflow (Part: 740-053638) |
| JPSU-850W-DC-AFO | QFX5100 850 Watt DC PSU, Front to Back airflow (Part: 740-053639) |
| Power Cords/Cables |
|---|
| CBL-EX-PWR-C13-AR | AC Power Cable - Argentina (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-AU | Power Cable, Australia |
| CBL-EX-PWR-C13-BR | AC Power Cable - Brazil (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-C14 | AC Power Cable - Patch Cord, (10A/250V, 2.5m) (Part: 740-034568) |
| CBL-EX-PWR-C13-CH | Power Cable, China |
| CBL-EX-PWR-C13-EU | Power Cable, Europe |
| CBL-EX-PWR-C13-IL | AC Power Cable - Israel (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-IN | AC Power Cable - India (6A/250V, 2.5m) |
| CBL-EX-PWR-C13-IT | Power Cable, Italy |
| CBL-EX-PWR-C13-JP | Power Cable, Japan |
| CBL-EX-PWR-C13-KR | Power Cable, Korea |
| CBL-EX-PWR-C13-SA | AC Power Cable - South Africa (10A/250V, 2.5m) |
| CBL-EX-PWR-C13-SZ | Power Cable, Switzerland |
| CBL-EX-PWR-C13-UK | Power Cable, UK |
| CBL-EX-PWR-C13-US | Power Cable, US |
| CG_CBL-C13-06 | |
| Adapters |
|---|
| MAM1Q00A-QSA | |
| Rack Mounting Kits |
|---|
| EX-4PST-RMK | 4-Post Adjustable Rack Mount Kit for EX4400, EX4300, EX4100, EX3400, EX4100-F, and EX2300 Switches (Part: 760-030688) |
| JNP-4PST-RMK-1U-E | Enhanced 4-Post Rack Mount Kit for 1RU platform (Part: 760-141941) |