The Juniper QFX5230-64CD-TCHAS is a high-performance network component designed for the QFX5230-64CD series.

Our CCIE certified engineers can help you verify compatibility.
Global logistics network aiming for same-day handover.
Every unit undergoes rigorous 38-point inspection test.
Trusted by enterprise clients across 6 continents.
Certified network engineers ready to assist with configuration.
The Juniper QFX5230-64CD-TCHAS is a high-performance network component designed for the QFX5230-64CD series.
| QFX5230-64CD-AFI — Overview | |
|---|---|
| Full Product Name | QFX5230-64CD Switch |
| OS Supported | Junos OS Evolved |
| QFX5230-64CD-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 2 U |
| Chassis Height | 3.43 in / 8.7122 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 25.6 in / 65.024 cm |
| Chassis Weight (Fully Loaded With All Components) | 55 lb / 24.94 kg |
| Chassis Model Number | QFX5230-64CD-CHAS |
| QFX5230-64CD-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| AFO/AFI? | AFI |
| Airflow Volume | 500 CFM |
| Fan Module Model Number | QFX5230-64CD-FANAI |
| Fan Module Count | 4 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5230-64CD-AFI — Environmental Specifications | |
| Operating Altitude | 0 ft (0 m) |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5230-64CD-AFI — Built-in Network Ports | |
| SFP+ Port Count | 2 |
| QSFP56-DD Port Count | 64 |
| QSFP56-DD Port Channelization | Y |
| QFX5230-64CD-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5230-64CD-AFI — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 51200 Gbps |
| Throughput (Unidirectional) | 25600 Gbps |
| Forwarding Capacity | 10.53 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 720 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 720 |
| IPv6 Unicast Host Routes (Thousands) | 366 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 366 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 2000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 768 |
| Ingress Port ACL | 3000 |
| Ingress Routed ACL | 3000 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 128 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 128 |
| Maximum Mirroring Sessions | 8 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 112 MB |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5230-64CD-AFI — Processor | |
| CPU | Intel 6-core Intel Hewitt Lake D-1637 |
| DRAM | 32 GB |
| QFX5230-64CD-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JNP-2700W-AC-AFI |
| AC Max Power Consumption | 1396 W |
| AC Average Power Consumption | 498 W |
| Grounding Cable Lug Type | Panduit LCD4-14A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 4 AWG |
| QFX5230-64CD-AFI — Storage | |
| Internal Storage Size | 200 (100+100) GB |
| Internal Storage Type | SSD |
| QFX5230-64CD-AFO — Overview | |
| Full Product Name | QFX5230-64CD Switch |
| OS Supported | Junos OS Evolved |
| QFX5230-64CD-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 2 U |
| Chassis Height | 3.43 in / 8.7122 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 25.6 in / 65.024 cm |
| Chassis Weight (Fully Loaded With All Components) | 55 lb / 24.94 kg |
| Chassis Model Number | QFX5230-64CD-CHAS |
| QFX5230-64CD-AFO — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Airflow Volume | 495 CFM |
| Fan Module Model Number | QFX5230-64CD-FANAO |
| Fan Module Count | 4 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5230-64CD-AFO — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5230-64CD-AFO — Built-in Network Ports | |
| SFP+ Port Count | 2 |
| QSFP56-DD Port Count | 64 |
| QSFP56-DD Port Channelization | Y |
| QFX5230-64CD-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5230-64CD-AFO — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 51200 Gbps |
| Throughput (Unidirectional) | 25600 Gbps |
| Forwarding Capacity | 10.53 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 720 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 720 |
| IPv6 Unicast Host Routes (Thousands) | 366 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 366 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 2000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 768 |
| Ingress Port ACL | 3000 |
| Ingress Routed ACL | 3000 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 128 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 128 |
| Maximum Mirroring Sessions | 8 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 112 MB |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5230-64CD-AFO — Processor | |
| CPU | Intel 6-core Intel Hewitt Lake D-1637 |
| DRAM | 32 GB |
| QFX5230-64CD-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| AC PSU Model Number | JNP-3000W-AC-AFO |
| AC Max Power Consumption | 1396 W |
| AC Average Power Consumption | 498 W |
| Grounding Cable Lug Type | Panduit LCD4-14A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 4 AWG |
| QFX5230-64CD-AFO — Storage | |
| Internal Storage Size | 200 (100+100) GB |
| Internal Storage Type | SSD |
| QFX5230-64CD-D-AFI — Overview | |
| Full Product Name | QFX5230-64CD Switch |
| OS Supported | Junos OS Evolved |
| QFX5230-64CD-D-AFI — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 2 U |
| Chassis Height | 3.43 in / 8.7122 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 25.6 in / 65.024 cm |
| Chassis Weight (Fully Loaded With All Components) | 55 lb / 24.94 kg |
| Chassis Model Number | QFX5230-64CD-CHAS |
| QFX5230-64CD-D-AFI — Cooling System | |
| Airflow Direction | Back-to-front |
| Airflow Volume | 496 CFM |
| AFO/AFI? | AFI |
| Fan Module Model Number | QFX5230-64CD-FANAI |
| Fan Module Count | 4 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5230-64CD-D-AFI — Environmental Specifications | |
| Operating Altitude | 0 ft (0 m) |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5230-64CD-D-AFI — Built-in Network Ports | |
| SFP+ Port Count | 2 |
| QSFP56-DD Port Count | 64 |
| QSFP56-DD Port Channelization | Y |
| QFX5230-64CD-D-AFI — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5230-64CD-D-AFI — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 51200 Gbps |
| Throughput (Unidirectional) | 25600 Gbps |
| Forwarding Capacity | 10.53 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 720 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 720 |
| IPv6 Unicast Host Routes (Thousands) | 366 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 366 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 2000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 768 |
| Ingress Port ACL | 3000 |
| Ingress Routed ACL | 3000 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 128 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 128 |
| Maximum Mirroring Sessions | 8 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 112 MB |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5230-64CD-D-AFI — Processor | |
| CPU | Intel 6-core Intel Hewitt Lake D-1637 |
| DRAM | 32 GB |
| QFX5230-64CD-D-AFI — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Back-to-front |
| PSU Hot-Removable And Hot-Insertable? | Y |
| DC PSU Model Number | JNP-2400W-DC-AFI |
| DC Max Power Consumption | 1446 W |
| DC Average Power Consumption | 487 W |
| Grounding Cable Lug Type | Panduit LCD4-14A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 4 AWG |
| QFX5230-64CD-D-AFI — Storage | |
| Internal Storage Size | 200 (100+100) GB |
| Internal Storage Type | SSD |
| QFX5230-64CD-D-AFO — Overview | |
| Full Product Name | QFX5230-64CD Switch |
| OS Supported | Junos OS Evolved |
| QFX5230-64CD-D-AFO — Chassis | |
| Fixed/Modular Chassis? | Fixed |
| Form Factor | 2 U |
| Chassis Height | 3.43 in / 8.7122 cm |
| Chassis Width | 17.4 in / 44.196 cm |
| Chassis Depth | 25.6 in / 65.024 cm |
| Chassis Weight (Fully Loaded With All Components) | 55 lb / 24.94 kg |
| Chassis Model Number | QFX5230-64CD-CHAS |
| QFX5230-64CD-D-AFO — Cooling System | |
| Airflow Direction | Front-to-back |
| AFO/AFI? | AFO |
| Airflow Volume | 497 CFM |
| Fan Module Model Number | QFX5230-64CD-FANAO |
| Fan Module Count | 4 |
| Fan Module Hot-Removable And Hot-Insertable? | Y |
| QFX5230-64CD-D-AFO — Environmental Specifications | |
| Operating Altitude | 6000 ft / 1828 m |
| Operating Temperature | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% |
| Relative Humidity, Noncondensing (Nonoperating) | 5% through 90% |
| Seismic Tolerance | Zone 4 |
| Maintenance Clearance | 30 in / 76.2 cm |
| QFX5230-64CD-D-AFO — Built-in Network Ports | |
| SFP+ Port Count | 2 |
| QSFP56-DD Port Count | 64 |
| QSFP56-DD Port Channelization | Y |
| QFX5230-64CD-D-AFO — Other Port Configuration | |
| Console Port Count | 1 |
| Console Port Type | RJ-45 |
| Management Port Count | 1 |
| Management Port Type | RJ-45 |
| USB Port Count | 1 |
| USB Port Type | Type A |
| 10 MHz Port | Y |
| PPS Port | Y |
| QFX5230-64CD-D-AFO — Performance (Routing/Switching) | |
| Throughput (Bidirectional) | 51200 Gbps |
| Throughput (Unidirectional) | 25600 Gbps |
| Forwarding Capacity | 10.53 Bpps |
| IPv4 Unicast Host Routes (Thousands) | 720 |
| IPv4 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv4 Unicast Routes Prefixes (FIB) (Thousands) | 720 |
| IPv6 Unicast Host Routes (Thousands) | 366 |
| IPv6 Unicast Routes Prefixes (RIB) (Thousands) | 2000 |
| IPv6 Unicast Routes Prefixes (FIB) (Thousands) | 366 |
| Egress VLAN ACL | 512 |
| Egress Port ACL | 2000 |
| Egress Routed ACL | 2000 |
| Ingress VLAN ACL | 768 |
| Ingress Port ACL | 3000 |
| Ingress Routed ACL | 3000 |
| ARP Entries (Thousands) | 32 |
| LAGs Count | 128 |
| Ports Per LAG | 64 |
| MAC Addresses Per System (Thousands) | 128 |
| Maximum Mirroring Sessions | 8 |
| Traffic Mirroring Destination VLANs | 4 |
| Traffic Mirroring Destination Ports | 4 |
| VLAN IDs Count | 4000 |
| Jumbo Frame | 9216 bytes |
| Total Packet Buffer | 112 MB |
| QoS Hardware Queues Per Port (Multicast) | 2 |
| QoS Hardware Queues Per Port (Unicast) | 8 |
| QFX5230-64CD-D-AFO — Processor | |
| CPU | Intel 6-core Intel Hewitt Lake D-1637 |
| DRAM | 32 GB |
| QFX5230-64CD-D-AFO — Power System | |
| PSU Count | 2 |
| PSU Redundancy | 1+1 |
| PSU Airflow Direction | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y |
| DC PSU Model Number | JNP-3000W-DC-AFO |
| DC Max Power Consumption | 1446 W |
| DC Average Power Consumption | 487 W |
| Grounding Cable Lug Type | Panduit LCD4-14A-L |
| Grounding Cable Temperature Rating | 90° C / 194° F |
| Grounding Cable Wire Gauge | 4 AWG |
| QFX5230-64CD-D-AFO — Storage | |
| Internal Storage Size | 200 (100+100) GB |
| Internal Storage Type | SSD |
No reviews yet
Be the first to review this enterprise product.
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
Still have questions?