H3C RT-MSR5680-X3 MSR5680-X3 Router Chassis. System Switching Capacity: 8Tbps~88Tbps. Fixed Ports: SPU-100-X1:10*GE(Combo)SPU-200-X1:10*GE(Combo)+ 2*SFP+SPU-300-G:4*25GE + 16*SFP+ +16*GE SPU-400-X1:10*GE(Combo)+ 4*SFP+SPU-600-X1(SPE-S1):4*GE(Combo)+ 4*SFPSPU-600-X1(SPE-S3):8*SFP+. Memory: MPU-100-X1:2GBMPU-100-G:4GBSPU-100/200-X1:2GBSPU-300-G:8GBSPU-400-X1:4GBSPU-600-X1(SPE-S1):2GBSPU-600-X1(SPE-S3):8GB
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C MSR5680-X3 Router Chassis |
| Key Specifications | |
| System Switching Capacity | 8Tbps~88Tbps |
| Fixed Ports | SPU-100-X1:10*GE(Combo)SPU-200-X1:10*GE(Combo)+ 2*SFP+SPU-300-G:4*25GE + 16*SFP+ +16*GE SPU-400-X1:10*GE(Combo)+ 4*SFP+SPU-600-X1(SPE-S1):4*GE(Combo)+ 4*SFPSPU-600-X1(SPE-S3):8*SFP+ |
| Interface Type | Supports FE, GE, 10GE, 25GE Ethernet interfaces; supports 155M POS, 622M POS, and 155M CPOS interfaces Supports E1-F/E1 interfaces |
| Dimensions (W×D×H, mm) | 440×480×219.5 |
| Maximum Power Consumption | 300W (single)/450W (quad) |
| Power Supply | AC:100V~240V、50Hz/60HzDC:-48V~-60V |
| Product Specifications | |
| Forwarding Performance | 945Mpps~13500Mpps |
| System Switching Capacity | 8Tbps~88Tbps |
| IPsec Throughput | 4.8Gbps~35Gbps |
| Supervisor Engine Module | 2,1:1 |
| Fixed Ports | SPU-100-X1:10*GE(Combo)SPU-200-X1:10*GE(Combo)+ 2*SFP+SPU-300-G:4*25GE + 16*SFP+ +16*GE SPU-400-X1:10*GE(Combo)+ 4*SFP+SPU-600-X1(SPE-S1):4*GE(Combo)+ 4*SFPSPU-600-X1(SPE-S3):8*SFP+ |
| HMIM Service Slot | 8 |
| DHMIM service slot | 2 |
| Memory | MPU-100-X1:2GBMPU-100-G:4GBSPU-100/200-X1:2GBSPU-300-G:8GBSPU-400-X1:4GBSPU-600-X1(SPE-S1):2GBSPU-600-X1(SPE-S3):8GB |
| FLASH | MPU-100-X1:8GBMPU-100-G:4GB |
| USB | 2, support 3G/4G Modem expansion |
| Console Port | 1 |
| CON(Mini-USB Type AB) | 1 |
| Maximum Power Consumption | 300W (single)/450W (quad) |
| Power Supply | AC:100V~240V、50Hz/60HzDC:-48V~-60V |
| Redundant power supplies | Built-in redundancy 4 power supplies, N+M backups |
| Device Height | 5 RU |
| Dimensions (W×D×H, mm) | 440×480×219.5 |
| Ambient temperature | -20-65℃ |
| operating temperature | -20-65℃ |
| Ambient Relative Humidity | 5 to 95% (no condensation) |
| EMC | FCC Part 15 (CFR 47) CLASS AICES-003 CLASS A VCCI-3 CLASS A VCCI-4 CLASS A CISPR 22 CLASS A EN 55022 CLASS A AS/NZS CISPR22 CLASS A CISPR 24EN 55024EN 61000-3-2EN 61000-3-3EN 61000-6-1ETSI EN 300 386EN 301 489-1EN 301 489-17 |
| Security | UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1/A11AS/NZS 60950EN 60825-1EN 60825-2FDA 21 CFR Subchapter J GB 4943 |
| Layer 2 Protocols | Supports Ethernet, Ethernet II, VLAN (VLAN-BASED PORT VLAN, VOICE VLAN, Guest VLAN), 802.3x, 802.1p, 802.1Q, 802.1x, STP(802.1D), RSTP(802.1w), MSTP(802.1 s), PPP, PPPoE Client, PPPoE Server, HDLC, DDR, Modem, ISDN, etc. |
| Interface Type | Supports FE, GE, 10GE, 25GE Ethernet interfaces; supports 155M POS, 622M POS, and 155M CPOS interfaces Supports E1-F/E1 interfaces |
| IP Services | Support Unicast Forwarding/Multicast Forwarding, TCP, UDP, IP Option, IP Unnumber, Policy Routing, Netstream, s Flow, etc Support ECMP Support UCMP |
| IP Applications | Support Ping, Trace, ICMP, DHCP Server, DHCP Relay, DHCP Client, DHCP Snooping, DNS client, DNS Proxy, DDNS, IP Accounting, UDP Helper, NTP, SNTP, and so on. |
| IPv4 Routing | Static routing Dynamic routing protocols: RIPv1/v2, OSPFv2, BGP (Neighbor Count 512), IS-IS routing Iterative Routing Policy ECMP (Equivalent Multipath) Multicast routing protocols: IGMPV1/V2/V3, PIM-DM, PIM-SM, MBGP, MSDP |
| IPv6 | Support Ipv6 ND, Ipv6 PMTU, Ipv6 FIB, Ipv6 ACL, NAT-PT, Ipv6 Tunneling, 6PE, DS-LITE; IPv6 Tunneling Technologies: Manual Tunneling, Auto Tunneling, GRE Tunneling, 6to4, Static Routing Dynamic Routing Protocols: RIPng, OSPFv3, IS-ISv6, BGP4+ IPv6 Multicast Protocols: MLD V1/V2, PIM-DM, PIM-SM |
| QoS | Supports LR, Port-Based Mirroring, Port Trust Mode, Port Priority, etc. Supports CAR (Committed Access Rate) Supports FIFO, WFQ, CBQ, etc. Supports WRED (Weighted Randomized Prior Detection) Supports GTS (Generic Traffic Shaping) supports traffic classification supports 5-layer H-QoS (Hierarchical QoS) supports packet marking function (based on IP address, port number, 802.1P, DSCP value, etc.) supports Hierarchical QoS (H-QoS), supports PQ/WFQ/CBWFQ and other queue scheduling mechanisms supports multi-level queuing mechanism for packets (including CQ, PQ, LLQ, WFQ etc.) |
| Voice | Support FXS/FXO/E&M/E1/T1, support R2, DSS1, Q.sig, etc. Support G.711, G.723, G.726, G.729AB, etc. Support Rich Voice Services, Voice Backup, DTMF Transmission Support RFC2833, Intelligent Dial-up Router, 1:1 Binding of FXS and FXO, Power Failure Escape, SIP Sever Local survival, IVR, etc. |
| 4/5G | Acts as LNS, interfacing with 4/5G access devices |
| Security Features | PPPoE Client&Server, PORTAL, 802.1x Local Authentication, RBAC, Radius, TacacsASPF, ACL, FILTER, Connection Count Limit IKE, IPSecADVPNL2TP, NAT/NAPT, PKI, RSA, SSH v1.5/2.0. URPF, GRE (supports GRE over IPSec) Supports ARP anti-attack Supports EAD Endpoint Access Defense Supports EVI, VxLAN, Trill and other data center features Supports State Secret Encryption |
| MPLS | Protocol: LDP, Static LSPL3VPN: Cross-domain MPLS VPN (Option1/2/3), Nested MPLS VPN, Hierarchical PE (HoPE), CE Dual Attribution, MCE, Multi-Role Hosts, etc. L2VPN: Supports Martini, Kompella, PWE3, CCC, and SVC methods, MPLS TE, MPLS-TP, RSVP TE, multicast VPNs |
| Reliability | Supports IRF2 Supports NSR, GR Supports VRRP, VRRPv3 Supports load sharing and backup based on multiple links Supports NQA with routing, VRRP, and interface backup linkage function to achieve end-to-end link detection and backup function Supports master-control-master-standby inversion of BFD fast link detection, hardware BFD (minimum packet sending interval of 10ms) |
| Management and Maintenance | Support SNMP V1/V2c/V3, MIB, SYSLOG, RMON Support BiMS remote management solution, support U disk opening Support command line management, file system management, Dual ImageNQA (Network Quality Assurance) Support DHCP, FTP, HTTP, ICMP, UDP public, UDP private, TCP public, TCP private, SNMP and other protocols test support console port login, support telnet (VTY) login, support SSH login, support FTP login |
| SDN | Supports VxLAN, EVPN, intelligent routing Supports Telemetry, BGP-LS, BGP IPv4/IPv6 Flow Spec Supports NQA, iNQA, TWAMP-light, iFIT Supports Segment routing, SRv6 Supports BFD for SR/SRv6 Supports CBTS, WAAS Support for opening auto-deployment, Netconf support for channelized sub-interfaces, cloud platform connectivity |
| Ordering Information | |
| MSU | |
| 0231AK5C | RT-MSU-200 - H3C MSU-200 Main Control Service Processing Unit (2*10GE(SFP+),2*GE Combo,8*GE(RJ45),1*SIC Slot) |
| SIC module | |
| 0231AEST | RT-SIC-5G - 5G NR (NSA/SA/4G FDD/TDD LTE-A/3G WCDMA,Sub6,GNSS) SIC module |
| Antenna | |
| 2701A02J | ANT-5G-NR - 5G NR Rod Antenna - SMA Interface |
| 2701A00P | ANT-SL15346E - Omnidirectional Antenna - 806–960 MHz/1710–2500 MHz - 3 d Bi - Vertical Polarization - 50 W - TNC (Male) - No Mount - Ceiling-Mounted Antenna |
| 2701A00Q | ANT-SL15209B - Omnidirectional Antenna - 824–965 MHz/1710–2170 MHz - 3 d Bi - Vertical Polarization - 50 W - TNC (Male) - Magnetic Mount - Mobile Device Antenna - 3-meter Extension Cable |
| Cable Optional Configuration Scheme | |
| 0150A2H3 | CAB-RF-10m-SMA-B - 10m Antenna Extension Cable - Wall Mounting Bracket - SMA Interface |
| 0150A2H2 | CAB-RF-10m-SMA-M - 10m Antenna Extension Cable - Magnetic Base - SMA Interface |
| 0150A2H4 | CAB-RF-15m-SMA-B - 15m Antenna Extension Cable - Wall Mounting Bracket - SMA Interface |
| 0150A2H7 | CAB-RF-15m-SMA-M - 15m Antenna Extension Cable - Magnetic Base - SMA Interface |
| 0150A2H6 | CAB-RF-5m-SMA-B - 5m Antenna Extension Cable - Wall Mounting Bracket - SMA Interface |
| 0150A2H5 | CAB-RF-5m-SMA-M - 5m Antenna Extension Cable - Magnetic Base - SMA Interface |
| SFP+ 10G Port | |
| 02312170 | SFP-GE-LH40-SM1310 - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 02312172 | SFP-GE-LH40-SM1550 - Optical Module—SFP—GE—Single-Mode Module—(1550 nm, 40 km, LC) |
| 02312173 | SFP-GE-LH80-SM1550 - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231A085 | SFP-GE-T - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A0BY | SFP-GE-LX10-SM1310 - SFP GEOptical Module-(-40°C~85°C,1310nm,10km,LX,SM,LC) |
| 0231A0SP | SFP-XG-LH40-SM1550 - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A11U | SFP-GE-LX-SM1310-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1310/RX 1490, 10 km, LC |
| 0231A11V | SFP-GE-LX-SM1490-BIDI - Optical Module - SFP Gigabit BIDI Optical Module - TX 1490/RX 1310, 10 km, LC |
| 0231A1PA | SFP-XG-LH80-SM1550 - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A1RP | SFP-XG-SX-MM850-D - SFP+ 10GModule(850nm,300m,LC) |
| 0231A1RQ | SFP-XG-LX-SM1310-D - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A1RR | SFP-XG-LH40-SM1550-D - SFP+ 10GModule(1550nm,40km,LC) |
| 0231A2L3 | SFP-XG-LX-SM1310-E - SFP+ 10GModule(1310nm,10km,LC) |
| 0231A2L4 | SFP-XG-SX-MM850-E - SFP+ 10GModule(850nm,300m,LC) |
| 0231A2T6 | SFP-XG-LH80-SM1550-D - SFP+ 10GModule(1550nm,80km,LC) |
| 0231A2UL | SFP-GE-LH70-SM1490-BIDI - SFPGigabitBIDI Optical Module (TX 1490/RX 1550 nm, 70 km, LC) |
| 0231A2UM | SFP-GE-LH70-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1490 nm, 70 km, LC) |
| 0231A2UN | SFP-GE-LH40-SM1310-BIDI - SFP Gigabit BIDI Optical Module (TX 1310/RX 1550 nm, 40 km, LC) |
| 0231A2UP | SFP-GE-LH40-SM1550-BIDI - SFPGigabitBIDI Optical Module (TX 1550/RX 1310 nm, 40 km, LC) |
| 0231A562 | SFP-GE-SX-MM850-A - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A563 | SFP-GE-LX-SM1310-A - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A960 | SFP-GE-T-D - SFP GEElectrical Port Module(100m,RJ45) |
| 0231A961 | SFP-GE-SX-MM850-D - Optical Module - SFP-GE - Multimode Module (850 nm, 0.55 km, LC) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A963 | SFP-GE-LH40-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 40 km, LC) |
| 0231A964 | SFP-GE-LH80-SM1550-D - Optical Module - SFP-GE - Single-Mode Module - (1550 nm, 80 km, LC) |
| 0231ABSP | SFP-XG-LH40-SM1270-BIDI - SFP+ 10G BIDI Optical Module (TX 1270 nm/RX 1330 nm, 40 km, LC) |
| 0231ABSQ | SFP-XG-LX-SM1270-BIDI - SFP+ 10GBIDIOptical Module(TX1270nm/RX1330nm,10km,LC) |
| 0231ABSR | SFP-XG-LX-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 10 km, LC) |
| 0231ABSS | SFP-XG-LH40-SM1330-BIDI - SFP+ 10G BIDI Optical Module (TX 1330 nm/RX 1270 nm, 40 km, LC) |
| 0231ABST | SFP-XG-LH80-SM1490-BIDI - SFP+ 10GBIDI Optical Module (TX 1490nm/RX 1550nm, 80km, LC) |
| 0231ABSU | SFP-XG-LH80-SM1550-BIDI - SFP+ 10GBIDI Optical Module (TX 1550nm/RX 1490nm, 80km, LC) |
| 0231ADWF | SFP-GE-LH20-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,20km,LC) |
| 0231AEUM | SFP-XG-SX-MM850-S - SFP+ 10G Optical Module(850nm,300m,SX,LC) |
| 0231AEUN | SFP-GE-LX-SM1310-S - SFPGigabit Optical Module(1310nm,10km,LX,LC) |
| 0231AEUP | SFP-GE-SX-MM850-S - SFPGigabit Optical Module(850nm,550m,SX,LC) |
| 0231AEUQ | SFP-XG-LX-SM1310-S - SFP+ 10G Optical Module(1310nm,10km,LX,LC) |
| 0231AH26 | SFP-GE-LX-SM1310-BIDI-I - Optical Module-SFPGigabitBIDI Optical Module(-40℃~85℃,TX1310/RX1490,10km,LC) |
| 0231AH28 | SFP-GE-LX-SM1490-BIDI-I - Optical Module-SFPGigabitBIDI Optical Module(-40℃~85℃,TX1490/RX1310,10km,LC) |
| SFP Gigabit Port | |
| 0231A089 | SFP-FE-LH40-SM1310 - Optical Module - SFP 100M/155M Single-Mode Module - (1310nm, 40km, LC) |
| 0231A12T | SFP-FE-LX-SM1310-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1310/RX 1550 nm, 15 km, LC) |
| 0231A12U | SFP-FE-LX-SM1550-BIDI - SFP Fast Ethernet BIDI Optical Module (TX 1550/RX 1310 nm, 15 km, LC) |
| 0231A320 | SFP-FE-SX-MM1310-A - Optical Module—SFP 100M/155M Multimode Module (1310 nm, 2 km, LC) |
| 0231A564 | SFP-FE-LX-SM1310-A - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231A965 | SFP-FE-LX-SM1310-D - Optical Module—SFP 100M/155M Single-Mode Module (1310 nm, 15 km, LC) |
| 0231AK5D | RT-MSU-100 - H3C MSU-100 Main Service Processing Unit |
| 0231AKPU | RT-MSU-400-G - H3C MSU-400-G Main Service Processing Unit (10*10GE (SFP+), 8*GE (RJ45)) |
| XMIMModule | |
| 0231AK46 | RT-XMIM-2E1 - 2-port Partial Channelized E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module |
| Cable | |
| 0404A0KN | CAB-E1-75ohm-3m-RJ45-2*BNC - E1Cable-3m-(RJ45P-8P8CS+CORE(F5B-RH14.2*28.5*8))-(SFTP-CAT5E24(4P)P430U+2*(COAX-SYFVZ75-1-1))-(2*BNC75SM) |
| Extension | |
| 0404A076 | CAB-E1-120ohm-15m-RJ45 - E1 Trunk Cable - 15 m - (RJ45P-8P8CS) - (120CC4P0.5P430U(S)) - (RJ45P-8P8CS) - 120 ohms |
| 0404A09E | CAB-E1-120ohm-2m-RJ45 - E1 trunk cable - 2.00 m - (RJ45P-8P8CS) - (120CC4P0.5P430U(S)) - (RJ45P-8P8CS) - 120 ohms |
| 0404A077 | CAB-E1-120ohm-30m-RJ45 - E1 trunk cable - 30 m - (RJ45P-8P8CS) - (120CC4P0.5P430U(S)) - (RJ45P-8P8CS) - 120 ohms |
| 0404A078 | CAB-E1-10m-BNC - Single Cable—E1 Trunk Cable—75 ohms—10 m—(BNC to BNC) |
| 0404A079 | CAB-E1-15m-BNC - Single Cable—E1 Trunk Cable—75 ohms—15 m—(BNC to BNC) |
| 0404A080 | CAB-E1-20m-BNC - Single Cable - E1 Trunk Cable - 75 Ohm - 20 m - (BNC to BNC) |
| E1 Connector | |
| 04026813 | CAB-E1/75-120 Convert - E1 Cable 120 Ohm to 75 Ohm Adapter Box |
| 14040202 | CAB-BNC-75 - Coaxial Connector - BNC - 75Ω - Straight/Socket - Dual Female - Connects to E1 Cable BNC Male Plug |
| 0231AK47 | RT-XMIM-8E1 - 8-port Partial Channelized E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module |
| 0231AK48 | RT-XMIM-4E1 - 4-port Partial Channelized E1 (E1-F)-RJ45 or Channelized E1 (CE1/PRI)-RJ45 Interface XMIM Module |
| 0231AK61 | RT-XMIM-8GEE-R - 8-Port100/1000BASE-T-RJ45 L3InterfaceXMIMModule |
| 0231AK63 | RT-XMIM-2POS - 2-port OC-3c/STM-1c-SFP or 1-port OC-12c/STM-4c-SFP Interface XMIM Module |
| 0231A090 | SFP-FE-LH80-SM1550 - Optical Module—SFP 100M/155M Single-Mode Long-Distance Module—(1550 nm, 80 km, LC) |
| 0231A40B | SFP-622M-LX-SM1310 - 622M SFP Optical Module (1310 nm, 15 km, LC) |
| 0231AK64 | RT-XMIM-1POS - 1-port OC-3c/STM-1c-SFP or 1-port OC-12c/STM-4c-SFP Interface XMIM Module |
| 0231AKQ0 | RT-XMIM-8GEF-R - 8-Port100/1000BASE-X-SFP L3InterfaceXMIMModule |
| 0231ADWE | SFP-GE-LH40-SM1310-I - SFPGigabit Optical Module(-40℃~85℃,1310nm,40km,LC) |
| 0231AKW2 | RT-XMIM-4XP - 4-Port10GBASE-R-SFP+ L3InterfaceXMIMModule |
| 0231A9X2 | SFP-XG-CPRI-IR-SM1310 - SFP+ 10GCPRIOptical Module(-40°C~85°C,1310nm,1.4km,LC) |
| 0231A9X3 | SFP-XG-CPRI-LR-SM1310 - SFP+ 10GCPRI Optical Module (-40°C to 85°C, 1310 nm, 10 km, LC) |
| 0231AN0M | RT-XMIM-1CPOS - 1-port OC-3/STM-1 Channelized POS Optical Interface XMIM Module |
| Fan Options | |
| 0231AK4D | FAN-80B-2-C - Fan Frame Module (80-2, Fan Panel Side Outlet) |
| Power Supply Options | |
| 0231AK4C | 0231AK4C - MSR56 Router |
| 0231AK4E | PSR450-12D-F - 450W DC power Module (Air intake from power panel side) |
| 0231AKPK | PSR450-12A-A - 450W AC power Module (Air intake from power panel side) |
| IPPOS/IPS/ACG/VPNlicense certificate | |
| 3130A3LM | LIS-MSRB-WEBCACHE - H3C MSR 36/56 Series Web Cache Software License Agreement |
| 3130A1MB | LIS-MSR-IPPOS-256 - H3C MSR IP POS software authorization letter (supports 256-way concurrency) |
| 3130A1XU | LIS-MSRB-ACG-1Y - H3C MSR 26/36/56/ICG Series application identificationsignature database update service license certificate,1 year |
| 3130A1XV | LIS-MSRB-ACG-3Y - H3C MSR 26/36/56/ICG Series application identificationsignature database update service license certificate,3 years |
| Serial Cable | |
| 04042967 | CAB-CON-1.8m - Configuration Serial Cable—1.8 m—(DB9 Female to 8-pin Ethernet Port) |
| 0404A1EE | CAB-Console-1.8m-W31R - Configuration Port Cable-1.8m-(RJ45P)-(UL2725(3C28AWG))-(USB AP) |
| Product Identity | |
| Brand | H3C |
| Series | H3C MSR56 Series Router |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the System Switching Capacity specification for RT-MSR5680-X3?
What is the Console Port specification for RT-MSR5680-X3?
What is the Dimensions (W×D×H, mm) specification for RT-MSR5680-X3?
What is the HMIM Service Slot specification for RT-MSR5680-X3?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?