H3C UN-R3900-G7-UAL0-C Uni Server R3900 G7 AP LFF air-cooled CTO server

H3C UN-R3900-G7-UAL0-C
H3C UN-R3900-G7-UAL0-C Uni Server R3900 G7 AP LFF air-cooled CTO server. Acceleration card supports: Supports 4 double-wide GPU acceleration cards + 1 double-wide DPU acceleration card, supporting 8 single-wide GPU acceleration cards + 1 double-wide DPU acceleration card 1. CPU: Supports 1× IntelⓇ XeonⓇ 6 processor. Memory: Supports 12× DDR5 memory slots; maximum speed 6400MT/s; supports 12× MRDIMM memory slots; maxi
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C Uni Server R3900 G7 AP LFF air-cooled CTO server |
| Key Specifications | |
| Dimensions/Chassis Size | 2U standard chassis: 87.5mm (H) × 445.4mm (W) × 800mm (D) (excluding safety panel)/87.5mm (H) × 445.4mm (W) × 828mm (D) (including safety panel) |
| operating temperature | 5℃ - 40℃ |
| CPU | Supports 1× IntelⓇ XeonⓇ 6 processor |
| Memory | Supports 12× DDR5 memory slots; maximum speed 6400MT/s; supports 12× MRDIMM memory slots; maximum speed 8800MT/s; additionally supports extending 16 memory slots via CXL1 |
| Storage Controller | Supports RAID 0/1/5/6/10/50/60, etc.; Optional 8GB cache; supports supercapacitor protection |
| Storage | Supports 28× 2.5-inch SAS/SATA drives1; supports 16× 3.5-inch SAS/SATA drives1; supports 16× NVMe drives; supports 12× E3.S drives (7.5mm)/8× E3.S drives (16.8mm) |
| Product Specifications | |
| CPU | Supports 1× IntelⓇ XeonⓇ 6 processor |
| Memory | Supports 12× DDR5 memory slots; maximum speed 6400MT/s; supports 12× MRDIMM memory slots; maximum speed 8800MT/s; additionally supports extending 16 memory slots via CXL1 |
| Storage Controller | Supports RAID 0/1/5/6/10/50/60, etc.; Optional 8GB cache; supports supercapacitor protection |
| Storage | Supports 28× 2.5-inch SAS/SATA drives1; supports 16× 3.5-inch SAS/SATA drives1; supports 16× NVMe drives; supports 12× E3.S drives (7.5mm)/8× E3.S drives (16.8mm) |
| Network | Built-in 1 dedicated 1Gbps management Ethernet port; supports 1 OCP 3.0 network card; supports hot swapping; supports Optional PCIe 5.0-standard slot network cards for PCIe expansion (supports on-demand configuration); supports Ethernet cards, Infini Band cards and smart network cards |
| extended slot | Supports 11 PCIe 5.0 expansion slots, 1 Optional OCP 3.0 slot |
| Acceleration card supports | Supports 4 double-wide GPU acceleration cards + 1 double-wide DPU acceleration card, supporting 8 single-wide GPU acceleration cards + 1 double-wide DPU acceleration card 1 |
| Interface | Standard: 2 VGA ports (1 front, 1 rear), 5 USB interfaces (2 front, 1 internal, 2 rear); includes 1 dedicated maintenance interface (front); includes 1 HDM management Ethernet port + 1 serial port (rear); Optional: 1 front HDM management Ethernet port |
| Fan Module | Supports hot-swappable fans, N+1 redundancy |
| Optical Drive | Supports external optical drive |
| Liquid cooling | Supports cold-plate liquid cooling and (fluorinated liquid or oil) immersion liquid cooling 1 |
| Power Supply | Optional 800W/1300W/1600W/2000W/2400W/2700W/3200W 1+1 redundant power supplies 1; Optional -48V/336V DC power Supply Module; supports 1+1 redundancy; Optional Platinum-grade/Titanium-grade; CQC31-461288 certification level V power supply |
| Authentication | Supports CCC, CQC, environmental and other certifications |
| operating temperature | 5℃ - 40℃ |
| Dimensions/Chassis Size | 2U standard chassis: 87.5mm (H) × 445.4mm (W) × 800mm (D) (excluding safety panel)/87.5mm (H) × 445.4mm (W) × 828mm (D) (including safety panel) |
| Management | HDM3 agentless management tool (with dedicated management port) and H3C Uni System management software; supports LCD touch intelligent management module; Optional U-Center data center management platform |
| Security | Supports security chassis and TCM/TPM security module |
| Warranty | 3 years, 5×9, Next Business Day (NBD) response |
| Ordering Information | |
| Processor | |
| 0231AQNP | UN-CPU-INTEL-6979P - R3900 G7 Servers |
| 0231AQNQ | UN-CPU-INTEL-6972P - R3900 G7 Servers |
| 0231AQNT | UN-CPU-INTEL-6960P - R3900 G7 Servers |
| 0231AQNU | UN-CPU-INTEL-6952P - R3900 G7 Servers |
| 0231AQP1 | UN-CPU-INTEL-6980P - R3900 G7 Servers |
| CPU Cooler | |
| 0231AQNR | UN-ME-HeatSink-AP-1UcY-M - R3900 G7 Servers |
| 0231AQNS | UN-ME-HeatSink-AP-2UcY-M - 2U high-performance T-type heat pipe cooling module (CMCTO) |
| Memory | |
| 0231AP60 | UN-DDR5-6400B-64G-2Rx4-R - 64GB 2RX4 DDR5-6400B RDIMMMemory Module(CTO&BTO) |
| 0231AP61 | UN-DDR5-6400B-96G-2Rx4-R - 96GB 2RX4 DDR5-6400B RDIMMMemory Module(CTO&BTO) |
| 0231AP69 | UN-DDR5-6400B-128G-2Rx4-R - R3900 G7 Servers |
| 0231AP6A | 0231AP6A - R3900 G7 Servers |
| Dummy Memory | |
| 0231AK76 | UN-DUMMY-DIMM-DDR5-M - DDR5 dummy memory module (CMCTO) |
| Front Hard Drive Backplane | |
| 0231AN9V | UN-PCA-BP-8LFF-UniBay-2U-G6 - G6 2U front 8LFF Uni Bay hard disk backplane module (CTO&BTO) |
| 0231AJPN | UN-PCA-BP-12LFF-4NVMe-2U-G6 - G6 2U front 12LFF supports 4NVMe hard disk backplane module (CTO&BTO) |
| 0231AJQ8 | UN-PCA-BP-12LFF-UniBay-2U-G6 - G6 2U front 12LFF Uni Bay hard disk backplane module (CTO&BTO) |
| Rear Hard Drive Cage | |
| 0231AK8A | UN-HDDCage-2UniBay-2U-G6 - G6 2U rear 2SFF Uni Bay hard disk cage module (CTO&BTO) |
| NVMe Cable Adjustment | |
| NVMECHK1 | NVMECHK1 - R3900 G7 Servers |
| M.2 Adapter Card | |
| 0231AP6H | UN-RC-2M2-G7 - R3900 G7 Servers |
| M.2 SSD | |
| 0231AHCQ | UN-SSD-480G-SATA-S4520-M.2 - 480GB SATA RI S4520 M.2 SSDHard Drive Module(CTO&BTO) |
| Fan | |
| 0231AQNN | UN-FAN-6056-2U-G7 - G7 2U 6056Fan Module(CTO&BTO) |
| Power Supply | |
| 0231ALYS | UN-CRPS-1300W-AC-12V-94%-M2 - 1300W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO) |
| 0231AGUP | UN-GW-CRPS1300D3 - 1300W AC&240V HVDC power Module (GW-R1-Platinum-low load high efficiency) (CTO&BTO) |
| 0231AKDP | UN-PAC1K3D12-B2 - 1300W AC & 240V HVDC power Supply Module (HW-R1- Platinum) (CTO&BTO) |
| 0231AJYB | UN-PS-2132-5L5 - 1300W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231ACT9 | DPS-1300AB-6 R-M - 1300W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231AMKU | UN-GW-CRPS1600C2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Titanium) (CTO&BTO) |
| 0231ANVH | UN-CRPS1600-AC12-Ti-B1-LT - 1600W AC & 240V HVDC power Supply Module (LT-R1- Titanium) (CTO&BTO) |
| 0231AMPJ | UN-CRPS-1600W-AC-12V-94%-M - 1600W AC & 240V HVDC power supply (Platinum) (CMCTO) |
| 0231ANVG | UN-CRPS1600-AC12-Ti-B1-M - 1600W AC & 240V HVDC power supply (Titanium) (CMCTO) |
| 0231AGUN | UN-GW-CRPS1600D2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Platinum) (CTO&BTO) |
| 0231ACTA | DPS-1600AB-13 R-M - 1600W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231AMQ7 | UN-CRPS-2000W-AC-12V-94%-M - 2000W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO) |
| 0231AFSS | UN-GW-CRPS2000D - 2000W AC & 240V HVDC power Supply Module (GW-R2- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231AHRU | UN-PS-2202-11L - 2000W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231ANVF | UN-CRPS3200-AC12-Ti-B1-GW - 3200W AC & 240V HVDC power Module (GW-R1-Titanium) (CTO&BTO) |
| Power Supply Cable | |
| 0404A0K4 | CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard |
| 0404A06Q | CAB-AC Pwr CHI-1.8m - Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard |
| Slot 1 & 2 Adapter Card | |
| 0231AJQ9 | UN-RC-3FHHL-2U-G6 - G6 2U Riser1/Riser2 X16X8X8 Riser (supports 3x 75W GPU) (CTO&BTO) |
| 0231AN9X | UN-RC-3FHFL-2U-G6-1 - G6 2U Riser1/Riser2 3X16 Riser module (supports 2x 150W GPUs and 1x FHHL) (CTO&BTO) |
| Riser specification confirmation | |
| AJQ9CHK3 | AJQ9CHK3 - R3900 G7 Servers |
| AN9XCHK1 | AN9XCHK1 - R3900 G7 Servers |
| AP8JCHK1 | AP8JCHK1 - R3900 G7 Servers |
| AP8KCHK1 | AP8KCHK1 - R3900 G7 Servers |
| Control card module | |
| 0231AG62 | UN-RAID-LSI-9560-LP-8i-4GB - LSI 9560-8i 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, PCIe, without supercapacitor) (CTO&BTO) |
| 0231AJ6E | UN-HBA-LSI-9500-LP-8i - LSI 9500-8i 12G SAS HBA card module (supports 8x SAS Ports, PCIe) (CTO&BTO) |
| 0231AEVL | UN-RAID-LSI-9560-LP-16i-8GB-M - LSI 9560-16i 12G SAS RAID card module (supports 16x SAS Ports, with 8GB cache, PCIe, excludes supercapacitor) (CMCTO) |
| 0231AJ6M | UN-HBA-LSI-9500-LP-16i - LSI 9500-16i 12G SAS HBA card module (supports 16x SAS Ports, PCIe) (CTO&BTO) |
| Battery | |
| 0231AEYR | UN-BAT-LSI-G3-A - LSI G3 supercapacitor module (CTO&BTO) |
| VROCModule(Supports NVMe Hard DriveRAID) | |
| 0231A6R6 | UN-NVMe-VROC-Key-S-F - Intel NVMe VROC module - Standard edition (FIO) |
| 0231A6R8 | UN-NVMe-VROC-Key-P-F - Intel NVMe VROC module - Advanced edition (FIO) |
| Graphics Card | |
| 0231ANF4 | UN-GPU-48GB-DW - NVIDIA 48G PCIe4.0 X16 FHFL GPUModule(CTO&BTO) |
| 0231ANMC | 0231ANMC - Nvidia L2 24G PCIe4.0 X16 HHHL GPUModule(CTO&BTO) |
| Network Adapter | |
| 0231AFUR | 0231AFUR - R3900 G7 Servers |
| Optical Module | |
| 0231AC16 | QSFP-100G-SR4-MM850-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO) |
| 0231AFUS | UN-IB-MCX653106A-ECAT-100Gb-2P - 100Gb 2-Port Infiniband HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231AGJA | UN-NIC-ETH-MCX623106AN-CDAT-2P - 2-Port100Gb QSFP56optical interfaceMCX623106AN-CDATNetwork Adapter(CTO&BTO) |
| 0231AH2Y | UN-NIC-BCM957508-P2100G-2P - 2-port 100Gb QSFP56 Optical Interface BCM957508-P2100G Ethernet card (CTO&BTO) |
| 0231A9AU | UN-NIC-X710DA2-F-B-10Gb-2P-F2 - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A8KB | UN-SFP-XG-SX-MM850-E1 - SFP+ 10GModule(850nm,300m,LC) |
| 0231AC0T | SFP-XG-LX-SM1310-CM - SFP+ 10GModule(1310nm,10km,LC)(FIO) |
| 0231AFRV | UN-NIC-ETH531F-LP-2P - 2-Port10GEoptical interface Network Adapter(CTO&BTO) |
| 0231A7NA | UN-CNA-560T-B2-10Gb-2P-1 - 2-Port10Gbelectrical interface Network Adapter-560T-B2 |
| 0231A8K1 | UN-NIC-GE-4P-360T-B2-1 - 4-Port Gigabitelectrical interface Network Adapter-360T-B2 |
| 0231AK5Y | UN-NIC-ETH330T-LP-4P - 4-PortGEelectrical interface Network Adapter(CTO&BTO) |
| 0231AFN8 | UN-IB-MCX653105A-HDAT-200Gb-1P - 200Gb 1-Port Infini Band HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231AM5N | UN-IB-MCX75310AAS-HEAT-200Gb-1P - 1-port 200Gb Infiniband NDR/Ethernet adapter card (supports OSFP optical modules) (CTO&BTO) |
| 0231AM5P | UN-IB-MCX755106AS-HEAT-200Gb-2P - 2-port 200Gb Infiniband NDR/Ethernet adapter card (supports QSFP112 optical modules) (CTO&BTO) |
| 0231A7NH | UN-NIC-620F-B2-25Gb-2P-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2 |
| 0231ANWW | UN-SFP28-25G-LR-SM1310 - 25G SFP28 optical module (1310nm, 10km, SM, LC) (CTO&BTO) |
| 0231A7N6 | SFP-25G-SR-MM850-1 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC) |
| 0231A7Q2 | UN-NIC-BCM957414-F-B-25Gb-2P-F - 2-Port25GEoptical interface Network Adapter(BCM957414)(FIO) |
| 0231AFUG | UN-NIC-ETH-MCX631102AN-ADAT - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO) |
| 0231AG88 | UN-NIC-ETH-E810XXVDA2G1P5-2P - 2-port 25Gb SFP28 Optical Interface E810XXVDA2G1P5 Ethernet card (CTO&BTO) |
| 0231ALPQ | UN-IB-MCX75310AAS-NEAT-400Gb-1P - 1-port 400Gb Infiniband NDR/Ethernet adapter card (supports OSFP optical modules) (CTO&BTO) |
| OCPNetwork Adapter | |
| 0231AEBU | UN-NIC-ETH360T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBV | UN-NIC-ETH565T-3S-2P - 2-Port10GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBY | UN-NIC-ETH561F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AN1D | UN-NIC-ETH531F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter (ETH531F)(CTO&BTO) |
| 0231AN1E | UN-NIC-ETH330T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter (ETH330T)(CTO&BTO) |
| 0231AG96 | UN-NIC-ETH-MCX631432AN-ADAB-2P - 2-Port25Gb SFP28optical interfaceMCX631432AN OCP3.0Network Adapter(CTO&BTO) |
| 0231AC0Y | SFP-GE-SX-MM850-CM - Optical module - SFP-GE-multimode optical module (850nm, 0.55km, LC) (FIO) |
| BMC Module | |
| 0231AP5S | UN-PCA-BMC-G7 - G7 BMC management board module (CTO&BTO) |
| i Fist Module | |
| 0231AJQ5 | UN-IFIST-EX-G6 - G6 iFISTModule(CTO&BTO) |
| Diagnostic Modules | |
| 0231AG61 | UN-SID-LCD-LFF - LFF LCD panel module (CTO&BTO) |
| Security Hardware | |
| 0231AKEY | UN-TCM-SPI-B - H3C server platform trusted module SPI TCM (CTO&BTO) |
| 0231AKEX | UN-TPM-SPI-B - H3C server series trusted platform module SPI TPM (CTO&BTO) |
| Optical Drive | |
| 0231A6R9 | 0231A6R9 - Mobile USB 2.0 interface read/write optical drive module (FIO) |
| Rack Rail | |
| 0231AKEB | UN-BB-2U-G6 - G6 2U/1U Ball Screw Guide Rails (CTO & BTO) |
| Cable Management Tray | |
| 0231AQCE | UN-CMA-2U-G6 - G6 2U Cable Management Rack (CTO & BTO) |
| Security Panel | |
| 0231AFTB | UN-SEC-Panel-2U-G5 - H3C Uni Server G5 2U intelligent security panel (CTO&BTO) |
| GPU Airflow Shroud | |
| 0231AP8E | UN-FAN-COVER-GPU-R3900-G7 - R3900 G7 Servers |
| Tag | |
| 0231AGWU | UN-Label-Shock&Tilt Monitor - Anti-tilt label and 37G anti-vibration label (CTO&BTO) |
| Is customization Required? | |
| CUSTNEED | CUSTNEED - R3900 G7 Servers |
| Customized module | |
| 0231A8A6 | UN-CTM-G3-F - H3C customer-specific customization module (1H) (FIO) |
| Installing Services | |
| 8814A0CP | SV-PS-UN - H3C server first basic installation service |
| License Fees | |
| 3130A66X | LIS-HDM-FORMAL-SERVER - H3C advanced feature license fee (CTO&BTO) |
| Product Identity | |
| Brand | H3C |
| Series | H3C R3900 G7 rack server |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the CPU specification for UN-R3900-G7-UAL0-C?
What is the Fan Module specification for UN-R3900-G7-UAL0-C?
What is the Optical Drive specification for UN-R3900-G7-UAL0-C?
What is the Liquid cooling specification for UN-R3900-G7-UAL0-C?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?