H3C UN-R4900LC-G5-SFF-C Uni Server R4900LC G5 SFF CTO liquid cooling server

H3C UN-R4900LC-G5-SFF-C
H3C UN-R4900LC-G5-SFF-C Uni Server R4900LC G5 SFF CTO liquid cooling server. GPU Support: Supports up to 3 dual-width GPU cards or 6 single-width GPU cards. Processor: Supports up to 2 Intel® Xeon® 3rd Gen Scalable family processors or Tyanxijun® Zhenye processor series, up to 40 cores per processor, maximum power 270W. Memory: Supports up to 32 DDR4 memory slots, speed up to 3200MT/s, supports RDIMM or LRDIMM; up to
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | H3C Uni Server R4900LC G5 SFF CTO liquid cooling server |
| Key Specifications | |
| Dimensions/Chassis Size | 2U chassis: 87.5mm (H) × 445.4mm (W) × 748mm (D) (excluding safety panel); 87.5mm (H) × 445.4mm (W) × 776mm (D) (including safety panel) |
| operating temperature | 5°C - 50°C (working temperature supported depends on different configurations; for details, refer to the detailed product technical documentation) |
| Processor | Supports up to 2 Intel® Xeon® 3rd Gen Scalable family processors or Tyanxijun® Zhenye processor series, up to 40 cores per processor, maximum power 270W |
| Chipset | Intel® C621A |
| Memory | Supports up to 32 DDR4 memory slots, speed up to 3200MT/s, supports RDIMM or LRDIMM; up to 16 Intel® Optane® Persistent Memory PMem 200 Series with a maximum capacity of 6TB per single-processor |
| Storage Controller | Standard onboard array controller; supports SATA RAID 0/1/10/5; Optional HBA cards and array cards based on standard PCIe slots |
| Product Specifications | |
| Processor | Supports up to 2 Intel® Xeon® 3rd Gen Scalable family processors or Tyanxijun® Zhenye processor series, up to 40 cores per processor, maximum power 270W |
| Chipset | Intel® C621A |
| Memory | Supports up to 32 DDR4 memory slots, speed up to 3200MT/s, supports RDIMM or LRDIMM; up to 16 Intel® Optane® Persistent Memory PMem 200 Series with a maximum capacity of 6TB per single-processor |
| Storage Controller | Standard onboard array controller; supports SATA RAID 0/1/10/5; Optional HBA cards and array cards based on standard PCIe slots |
| FBWC | Optional support for up to 8GB cache; supports supercapacitor protection |
| Storage | Supports up to 12 x 3.5-inch hard drives (12 front) supports up to 29 x 2.5-inch hard drives (25 front, 4 rear expansion); supports SAS/SATA HDD/SSD drives; supports up to 8 x NVMe drive slots; supports PCIe NVMe storage acceleration cards; supports SATA and PCIe M.2 options |
| Network | 1 x 1Gbps dedicated management Ethernet port on board; up to 1 x OCP 3.0 network card Optional; Optional expansion of 4×1GE electrical ports or 2×10GE electrical ports/fiber ports or 2×25GE fiber ports; Optional network adapter based on standard PCIe slots; supports 1/10/25/40/100/200GE NICs; IB cards |
| extended slot | Supports up to 6 x PCIe 4.0 standard slots |
| Interface | Standard: 1 x front VGA, 1 x rear VGA, and 1 x serial port; 6 x USB 3.0 (2 front, 2 rear, 2 internal); 1 x front dedicated management interface liquid-cooling interface: UQD04 male connector from the rear window of the chassis or tube + UQD04 female connector |
| GPU Support | Supports up to 3 dual-width GPU cards or 6 single-width GPU cards |
| Optical Drive | Supports external optical drive |
| Management | HDM agentless management tool (with a dedicated management port) and H3C Uni System management software; supports LCD touch intelligent management module; supports an Optional U-Center data center management platform with 64M local display memory |
| Security | Supports secure chassis, TCM/TPM security modules, and two-factor authentication |
| Power Supply and Cooling | Optional Platinum-level 550W/800W/850W/1200W/1300W/1600W/2000W/2400W 1+1 redundant power supplies; Optional Titanium-level power supplies; Optional 800W -48V/336V DC power supply modules; supports 1+1 redundancy; hot-pluggable redundant fans; supports CPU liquid cooling heat dissipation |
| Authentication | Supports SEPAetc.Authentication |
| operating temperature | 5°C - 50°C (working temperature supported depends on different configurations; for details, refer to the detailed product technical documentation) |
| Dimensions/Chassis Size | 2U chassis: 87.5mm (H) × 445.4mm (W) × 748mm (D) (excluding safety panel); 87.5mm (H) × 445.4mm (W) × 776mm (D) (including safety panel) |
| Warranty | 3 years, 5×9, Next Business Day (NBD) response |
| Ordering Information | |
| Excludes heat sink for processor | |
| 0231AKS2 | 0231AKS2 - 4309Y (2.8GHz/8 cores/12MB/105W) CPU module (CTO&BTO) |
| 0231AKSY | 0231AKSY - 4310 (2.1GHz/12 cores/18MB/120W) CPU module (CTO&BTO) |
| 0231AKT0 | UN-CPU-INTEL-4314 - 4314 (2.4GHz/16 cores/24MB/135W) CPU module (CTO & BTO) |
| 0231AKSA | 0231AKSA - 4316 (2.3GHz/20 cores/30MB/150W) CPU module (CTO&BTO) |
| 0231AKR4 | 0231AKR4 - 5315Y(3.2GHz/8 cores/12MB/140W)CPU module(CTO&BTO) |
| 0231AKSE | 0231AKSE - 5317(3.0GHz/12 cores/18MB/150W)CPU module(CTO&BTO) |
| 0231AKTJ | 0231AKTJ - 5318N(2.1GHz/24 cores/36MB/150W)CPU module(CTO&BTO) |
| 0231AKTQ | 0231AKTQ - R4900LCG5 Server |
| 0231AKTR | UN-CPU-INTEL-5318Y - 5318Y (2.1GHz/24-core/36MB/165W) CPU module (CTO&BTO) |
| 0231AKRM | UN-CPU-INTEL-5320 - 5320 (2.2GHz/26-core/39MB/185W) CPU module (CTO&BTO) |
| 0231AKRP | UN-CPU-INTEL-6326 - 6326 (2.9GHz/16-core/24MB/185W) CPU module (CTO&BTO) |
| 0231AKTV | UN-CPU-INTEL-6330 - 6330 (2.0GHz/28-core/42MB/205W) CPU module (CTO&BTO) |
| 0231AKRJ | 0231AKRJ - 6330N(2.2GHz/28 cores/42MB/165W)CPU module(CTO&BTO) |
| 0231AKTU | 0231AKTU - 6334(3.6GHz/8-core/18MB/165W)CPU module(CTO&BTO) |
| 0231AKT5 | 0231AKT5 - 6338(2.0GHz/32-core/48MB/205W)CPU module(CTO&BTO) |
| 0231AKT8 | 0231AKT8 - 6342(2.8GHz/24 cores/36MB/230W)CPU module(CTO&BTO) |
| 0231AKT9 | 0231AKT9 - 6346(3.1GHz/16 cores/36MB/205W)CPU module(CTO&BTO) |
| 0231AKSQ | UN-CPU-INTEL-6348 - 6348 (2.6GHz/28-core/42MB/235W) CPU module (CTO&BTO) |
| 0231AKST | 0231AKST - 6354(3.0GHz/18-core/39MB/205W)CPU module(CTO&BTO) |
| 0231AKR9 | 0231AKR9 - 8352V (2.1GHz/36 cores/54MB/195W) CPU module (CTO&BTO) |
| 0231AKRB | 0231AKRB - 8352Y(2.2GHz/32-cores/48MB/205W)CPU module(CTO&BTO) |
| 0231AKSS | 0231AKSS - 8358(2.6GHz/32-cores/48MB/250W)CPU module(CTO&BTO) |
| 0231AKRN | 0231AKRN - 8358P(2.6GHz/32-cores/48MB/240W)CPU module(CTO&BTO) |
| 0231AKSP | 0231AKSP - 8360Y(2.4GHz/36-cores/54MB/250W)CPU module(CTO&BTO) |
| 0231AKRX | 0231AKRX - 8362(2.8GHz/32-cores/48MB/265W)CPU module(CTO&BTO) |
| 0231AKS0 | 0231AKS0 - 8368(2.4GHz/38 cores/57MB/270W)CPU module (CTO&BTO) |
| 0231AKSR | 0231AKSR - 8368Q(2.6GHz/38c/57MB/270W)CPUModule(CTO&BTO) |
| 0231AKRQ | 0231AKRQ - 6336Y(2.4GHz/24-cores/36MB/185W)CPU module(CTO&BTO) |
| Processor | |
| 0231AGRY | 0231AGRY - H3C Uni Server R4900 G5 4309Y (2.8GHz/8-core/12MB/105W) CPU module (CTO&BTO) |
| 0231AGRP | 0231AGRP - H3C Uni Server R4900 G5 4310 (2.1GHz/12-core/18MB/120W) CPU module (CTO&BTO) |
| 0231AGS6 | 0231AGS6 - H3C Uni Server R4900 G5 4314 (2.4GHz/16-core/24MB/135W) CPU module (CTO&BTO) |
| 0231AGRQ | 0231AGRQ - H3C Uni Server R4900 G5 4316 (2.3GHz/20-core/30MB/150W) CPU module (CTO&BTO) |
| 0231AHTC | 0231AHTC - H3C Uni Server R4900 G5 5315Y (3.2GHz/8-core/12MB/140W) CPU module (CTO&BTO) |
| 0231AGS5 | 0231AGS5 - H3C Uni Server R4900 G5 5317 (3.0GHz/12-core/18MB/150W) CPU module (CTO&BTO) |
| 0231AHT2 | 0231AHT2 - H3C Uni Server R4900 G5 5318N (2.1GHz/24-core/36MB/150W) CPU module (CTO&BTO) |
| 0231AH8W | 0231AH8W - H3C Uni Server R4900 G5 5318S(2.1GHz/24-core/36MB/165W) CPU module(CTO&BTO) |
| 0231AGUC | 0231AGUC - H3C Uni Server R4900 G5 5320 (2.2GHz/26-core/39MB/185W) CPU module (CTO&BTO) |
| 0231AGS2 | 0231AGS2 - H3C Uni Server R4900 G5 6326 (2.9GHz/16-core/24MB/185W) CPU module (CTO&BTO) |
| 0231AG83 | 0231AG83 - H3C Uni Server R4900 G5 6330 (2.0GHz/28-core/42MB/205W) CPU module (CTO&BTO) |
| 0231AFVR | 0231AFVR - H3C Uni Server R4900 G5 6330N (2.2GHz/28-core/42MB/165W) CPU module (CTO&BTO) |
| 0231AHRP | 0231AHRP - H3C Uni Server R4900 G5 6334 (3.6GHz/8-core/18MB/165W) CPU module (CTO&BTO) |
| 0231AJDN | 0231AJDN - H3C Uni Server R4900 G5 6336Y (2.4GHz/24-core/36MB/185W) CPU module (CTO&BTO) |
| 0231AG81 | 0231AG81 - H3C Uni Server R4900 G5 6338 (2.0GHz/32-core/48MB/205W) CPU module (CTO&BTO) |
| 0231AHRS | 0231AHRS - H3C Uni Server R4900 G5 6342(2.8GHz/24 cores/36MB/230W)CPU module(CTO&BTO) |
| 0231AGM2 | 0231AGM2 - H3C Uni Server R4900 G5 6346(3.1GHz/16 cores/36MB/205W)CPU module(CTO&BTO) |
| 0231AG86 | 0231AG86 - H3C Uni Server R4900 G5 6348(2.6GHz/28-core/42MB/235W)CPU module(CTO&BTO) |
| 0231AHRQ | 0231AHRQ - H3C Uni Server R4900 G5 6354(3.0GHz/18-core/39MB/205W)CPU module(CTO&BTO) |
| 0231AHTB | 0231AHTB - H3C Uni Server R4900 G5 8352V(2.1GHz/36-core/54MB/195W)CPU module(CTO&BTO) |
| 0231AG98 | 0231AG98 - H3C Uni Server R4900 G5 8352Y(2.2GHz/32 cores/48MB/205W)CPU module(CTO&BTO) |
| 0231AGPX | 0231AGPX - H3C Uni Server R4900 G5 8358(2.6GHz/32 cores/48MB/250W)CPU module(CTO&BTO) |
| 0231AFVT | 0231AFVT - H3C Uni Server R4900 G5 8358P(2.6GHz/32 cores/48MB/240W) CPU module(CTO&BTO) |
| 0231AFVW | 0231AFVW - H3C Uni Server R4900 G5 8360Y(2.4GHz/36 cores/54MB/250W) CPU module(CTO&BTO) |
| 0231AHSU | 0231AHSU - H3C Uni Server R4900 G5 8362(2.8GHz/32 cores/48MB/265W)CPU module(CTO&BTO) |
| 0231AHTP | 0231AHTP - H3C Uni Server R4900 G5 8368(2.4GHz/38-core/57MB/270W) CPU module(CTO&BTO) |
| CPU Cooler | |
| 0231ALY4 | 0231ALY4 - R4900LCG5 Server |
| 0231ALYB | 0231ALYB - R4900LCG5 Server |
| 0231ALYM | 0231ALYM - R4900LCG5 Server |
| 0231ALYF | 0231ALYF - R4900LCG5 Server |
| 0231ALYE | UN-2P-G5-LC-CPU-UQD04 - R4700/4900LC G5 CPU immersion liquid cooling heat dissipation module (soft pipe direct outlet UQD04)(CTO & BTO) |
| Memory | |
| 0231AF6N | 0231AF6N - R4900LCG5 Server |
| 0231AF6R | 0231AF6R - 16GB 2Rx8 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AM1W | 0231AM1W - 16GB 2Rx8 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| 0231AM21 | 0231AM21 - R4900LCG5 Server |
| 0231AF76 | UN-DDR4-3200AA-32G-2Rx4-R - 32GB 2Rx4 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AG95 | UN-DDR4-3200AA-32G-2Rx8-R - 32GB 2Rx8 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AM1T | UN-DDR4-3200AA-32G-2Rx8-R-2 - 32GB 2Rx8 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| 0231AM25 | UN-DDR4-3200AA-32G-2Rx4-R-2 - 32GB 2Rx4 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| Front Hard Drive Backplane | |
| 0231AEYE | UN-PCA-BP-8SFF-2U-G5 - G5 8SFF hard drive backplane module (CTO & BTO) |
| 0231AEYV | UN-PCA-BP-8UniBay-2U-G5 - G5 25SFF Uni Bay hard drive backplane module (CTO & BTO) |
| Rear Hard Drive Cage | |
| 0231AFTJ | UN-HDDCage-2SFF-2U-G5 - H3C Uni Server G5 2U rear 2x SFF drive cage module (CTO & BTO) |
| M.2 Adapter Card | |
| 0231AF5Q | UN-RC-2M2-G5 - G5 front 2*M.2 2280/22110 Riser module(CTO&BTO) |
| M.2 SSD | |
| 0231ABTD | 0231ABTD - R4900LCG5 Server |
| 0231ABTE | 0231ABTE - R4900LCG5 Server |
| 0231AES4 | 0231AES4 - R4900LCG5 Server |
| 0231AES6 | 0231AES6 - R4900LCG5 Server |
| 0231AHCQ | UN-SSD-480G-SATA-S4520-M.2 - 480GB SATA RI S4520 M.2 SSDHard Drive Module(CTO&BTO) |
| Power Supply | |
| 0231AGUP | UN-GW-CRPS1300D3 - 1300W AC&240V HVDC power Module (GW-R1-Platinum-low load high efficiency) (CTO&BTO) |
| 0231AGUN | UN-GW-CRPS1600D2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Platinum) (CTO&BTO) |
| Power Supply Cable | |
| 0404A0X6 | CAB-DC PWR-3.0m-3V3 - (-48V) DC power cable-3.0m-(P3W-3V3 female connector)-(UL2464 12AWG/3C black)-(3*T2510 blue) |
| 0404A0K4 | CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard |
| 0404A06Q | CAB-AC Pwr CHI-1.8m - Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard |
| 04040890 | CAB-AC Pwr EN&SI-3m - Wall power outlet AC power cable - 3.0m - 1.0mm^2 - black - (BS1363A plug (3P) right-angle male 250V13A) - (H05VV-F) - (C13 connector (3P) straight female 250V10A) - UK standard |
| 0404A0MW | CAB-AC-16A-PDU-3m-Eu - PDU Power Supply Cable - 3.0 m - 1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (H05VV-F) - (C19 Connector (3P) Straight Female 250 V 16 A) - European Standard |
| Fan | |
| 0231AF5E | UN-FAN-6038-2U-G5 - G5 2U 6038Fan Module(CTO&BTO) |
| 0231AF5G | UN-FAN-6056-2U-G5 - H3C Uni Server G5 2U 6056Fan Module(CTO&BTO) |
| Slot 1 & 2 Adapter Card | |
| 0231AF52 | UN-RC-3FHFL-2U-SW-G5 - G5 2U 3X16 Riser (slot 1/2) (supports 2 FHFL and 1 FHHL, supports 2x 150W GPU) (CTO&BTO) |
| 0231AF5A | UN-RC-3FHFL-2U-G5 - G5 2U X16X8X8 Riser (slot 1/2) (supports 2 FHFL and 1 FHHL, supports 1 300W GPU) (CTO&BTO) |
| 0231ALY3 | UN-RC-2FHFL-2U-LC-G5 - G5 2U Riser2 2X16 Riser (supports 2 x FHFL, supports liquid cooling) (CTO&BTO) |
| Slot 3 Adapter Card | |
| 0231AF5L | UN-RC-2HHHL-R3-2U-G5 - G5 2U X8X8 Riser(Slot3)(Supports 2 x HHHL)(CTO&BTO) |
| 3X16 Adapter Card Slot Confirmation | |
| RISSLCHK | RISSLCHK - R4900LCG5 Server |
| Standard Control Card (PCIe Standard Card) | |
| 0231A8JY | 0231A8JY - LSI 9361-8i 12G SAS RAID card module (supports 8 x SAS Ports, with 1GB cache, PCIe, excluding power-loss protection module) (CMCTO) |
| 0231A8K4 | 0231A8K4 - LSI 9361-8i 12G SAS RAID card module (supports 8 x SAS Ports, with 2GB cache, PCIe, excluding power-loss protection module) (CMCTO) |
| 0231A8KA | UN-HBA-LSI-9300-8i-A1 - LSI 9300-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| 0231AB06 | UN-HBA-LSI-9311-8i-F - LSI 9311-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| 0231A8AY | UN-RAID-LSI-9460-8i(4G)-F - LSI 9460-8i 12G SAS RAID controller module (supports 8 x SAS Ports, includes 4GB cache, PCIe, excluding supercapacitor) (CMCTO) |
| 0231A8B5 | UN-RAID-LSI-9460-8i(2G)-F - LSI 9460-8i 12G SAS RAID card module (supports 8 SAS Ports, with 2GB cache, PCIe, without supercapacitor) (CMCTO) |
| 0231A8B0 | UN-HBA-LSI-9440-8i-F - LSI 9440-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| Battery | |
| 0231AEYS | UN-BAT-LSI-G2-A - LSI G2 supercapacitor module (CTO&BTO) |
| 0231AEYR | UN-BAT-LSI-G3-A - LSI G3 supercapacitor module (CTO&BTO) |
| 0231AFA4 | UN-BAT-PMC-G3-2U - PMC G3 Supercapacitor Module (for 2U Standard Chassis) (CTO & BTO) |
| VROCModule(Supports NVMe Hard DriveRAID) | |
| 0231A6R6 | UN-NVMe-VROC-Key-S-F - Intel NVMe VROC module - Standard edition (FIO) |
| 0231A6R8 | UN-NVMe-VROC-Key-P-F - Intel NVMe VROC module - Advanced edition (FIO) |
| 0231A7LJ | UN-NVMe-VROC-Key-i-F - Intel NVMe VROC module - Intel edition (FIO) |
| Graphics Card | |
| 0231AGGQ | 0231AGGQ - R4900LCG5 Server |
| 0231AFJE | 0231AFJE - R4900LCG5 Server |
| 0231AH39 | 0231AH39 - R4900LCG5 Server |
| 0231AHRC | 0231AHRC - NVIDIA A2 16G GPUModule(CTO&BTO) |
| 0231AGPS | 0231AGPS - R4900LCG5 Server |
| 0231AEC5 | 0231AEC5 - R4900LCG5 Server |
| 0231AGSV | 0231AGSV - R4900LCG5 Server |
| 0231AEDK | 0231AEDK - R4900LCG5 Server |
| 0231AJWA | UN-GPU-A2-16GB-NoCEC - Nvidia Tesla A2 16GB Non-CEC GPUModule(CTO&BTO) |
| 0231AJWD | 0231AJWD - R4900LCG5 Server |
| 0231ABT8 | UN-GPU-T4-F - T4 Display Acceleration Card (FIO) |
| T4 GPU Customer Validation | |
| T4GCHECK | T4GCHECK - R4900LCG5 Server |
| Network Adapter | |
| 0231A7GL | 0231A7GL - R4900LCG5 Server |
| 0231A7GM | 0231A7GM - R4900LCG5 Server |
| Optical Module | |
| 0231AFUN | UN-CAB-IB-DAC-MCP1600-E003E26-3m - Mellanox 3m EDR 100G DAC Cable (CTO&BTO) |
| 0231AC16 | QSFP-100G-SR4-MM850-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO) |
| 0231A9VY | 0231A9VY - R4900LCG5 Server |
| 0231AEC7 | 0231AEC7 - 1-port 100Gb QSFP28 Optical Interface MCX515A-CCAT Ethernet NIC (CMCTO) |
| 0231AE3E | QSFP-100G-SR4-MM850-B-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO) |
| 0231AFUR | 0231AFUR - R4900LCG5 Server |
| 0231AFUP | UN-CAB-IB-DAC-MCP7H50-V002R26-2m - Mellanox 2m HDR100 100G DAC breakout cable (CTO&BTO) |
| 0231ADWS | 0231ADWS - 2-Port100GEoptical interface Network Adapter(QSFP28)(CTO&BTO) |
| 0231AEC8 | UN-NIC-ETH-MCX516A-CCAT-2P-M - 100Gb 2-Port QSFP28 Optical Interface MCX516A-CCAT Ethernet Card (CMCTO) |
| 0231AF89 | 0231AF89 - R4900LCG5 Server |
| 0231AFUS | UN-IB-MCX653106A-ECAT-100Gb-2P - 100Gb 2-Port Infiniband HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231AGJA | UN-NIC-ETH-MCX623106AN-CDAT-2P - 2-Port100Gb QSFP56optical interfaceMCX623106AN-CDATNetwork Adapter(CTO&BTO) |
| 0231AC0U | QSFP-40G-SR4-MM850-CM - QSFP+ 40G optical module (850nm, 100m, SR4, supports 1 to 4) (FIO) |
| 0231AH2Y | UN-NIC-BCM957508-P2100G-2P - 2-port 100Gb QSFP56 Optical Interface BCM957508-P2100G Ethernet card (CTO&BTO) |
| 0231A7PW | UN-NIC-BCM957412-F-B-10Gb-2P-F - 2-Port10GEoptical interface Network Adapter(BCM957412)(FIO) |
| 0231A8KB | UN-SFP-XG-SX-MM850-E1 - SFP+ 10GModule(850nm,300m,LC) |
| 0231AC0T | SFP-XG-LX-SM1310-CM - SFP+ 10GModule(1310nm,10km,LC)(FIO) |
| 0231A7Q0 | 0231A7Q0 - R4900LCG5 Server |
| 0231A8K2 | UN-CNA-10GE-2P-560F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-560F-B2 |
| 0231AC0Y | SFP-GE-SX-MM850-CM - Optical module - SFP-GE-multimode optical module (850nm, 0.55km, LC) (FIO) |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| 0231A8K9 | UN-NIC-10GE-2P-530F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-530F-B2 |
| 0231A9AU | UN-NIC-X710DA2-F-B-10Gb-2P-F2 - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A9B7 | UN-NIC-X520DA2-F-B-10Gb-2P-F - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231AABV | 0231AABV - R4900LCG5 Server |
| 0231AES1 | 0231AES1 - R4900LCG5 Server |
| 0231AFH4 | 0231AFH4 - R4900LCG5 Server |
| 0231A7WC | UN-NIC-X710DA4-F-B-10Gb-4P-F - 4-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A7PX | UN-NIC-BCM957416-T-B-10Gb-2P-F - 2-Port10GEelectrical interface Network Adapter(BCM957416)(FIO) |
| 0231A8K1 | UN-NIC-GE-4P-360T-B2-1 - 4-Port Gigabitelectrical interface Network Adapter-360T-B2 |
| 0231AB04 | 0231AB04 - R4900LCG5 Server |
| 0231AFN8 | UN-IB-MCX653105A-HDAT-200Gb-1P - 200Gb 1-Port Infini Band HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231A7G6 | UN-NIC-MCX4121A-F-B-25Gb-2P-F - 2-Port25Gboptical interface Network Adapter(SFP28)(FIO) |
| 0231A7N6 | SFP-25G-SR-MM850-1 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC) |
| 0231A7GN | 0231A7GN - 2-Port25GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A7NH | UN-NIC-620F-B2-25Gb-2P-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2 |
| 0231A7Q2 | UN-NIC-BCM957414-F-B-25Gb-2P-F - 2-Port25GEoptical interface Network Adapter(BCM957414)(FIO) |
| 0231AB5W | UN-NIC-MCX512A-ACAT-F-2*25Gb-F - 2-Port25Gboptical interface Network Adapter(SFP28)(MCX512A-ACAT)(FIO) |
| 0231AF8A | UN-NIC-X2522-25Gb-2P-M - 2-port 25Gb SFP28 Optical Interface X2522-25G-PLUS low-latency network card (CTO&BTO) |
| 0231AFGV | 0231AFGV - R4900LCG5 Server |
| 0231AFUG | UN-NIC-ETH-MCX631102AN-ADAT - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO) |
| 0231AG88 | UN-NIC-ETH-E810XXVDA2G1P5-2P - 2-port 25Gb SFP28 Optical Interface E810XXVDA2G1P5 Ethernet card (CTO&BTO) |
| 0231AB60 | 0231AB60 - R4900LCG5 Server |
| 0231AB61 | 0231AB61 - R4900LCG5 Server |
| OCPNetwork Adapter | |
| 0231AEBU | UN-NIC-ETH360T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBV | UN-NIC-ETH565T-3S-2P - 2-Port10GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBX | 0231AEBX - R4900LCG5 Server |
| 0231AEBY | UN-NIC-ETH561F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231ABWF | UN-NIC-MCX4621A-ACAB-2*25G-M - 2-Port25G OCP3.0Network Adapter(MCX4621A-ACAB)(FIO) |
| 0231AEBW | UN-NIC-ETH640F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AFH3 | UN-NIC-ETH660F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AG96 | UN-NIC-ETH-MCX631432AN-ADAB-2P - 2-Port25Gb SFP28optical interfaceMCX631432AN OCP3.0Network Adapter(CTO&BTO) |
| 0231AGL9 | 0231AGL9 - R4900LCG5 Server |
| Fibre Channel controller | |
| 0231A7LG | UN-FC-HBA-LPe32000-32Gb-1P - 1-port 32Gb Fibre Channel HBA card (with one SFP+ optical module) |
| 0231A7LN | UN-FC-HBA-LPe32002-32Gb-2P - 2-port 32Gb optical fiber channel HBA card (with two SFP+ optical modules) |
| 0231A7NB | UN-HBA-16Gb-LPe31000-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module) |
| 0231A7NF | UN-HBA-16Gb-LPe31002-2P-1 - 2-port 16Gb Fibre Channel HBA card (with two SFP+ modules) |
| 0231A7PV | UN-FC-HBA-QLE2742-32Gb-2P-F - 32Gb-2-port-PCIe Fibre Channel HBA card (with two SFP+ optical modules) (FIO) |
| 0231A7Q1 | UN-FC-HBA-QLE2740-32Gb-1P-F - 32Gb-1-port-PCIe optical fiber channel HBA card (with one SFP+ optical module) (FIO) |
| 0231A8JQ | UN-FC-HBA-QLE2690-16Gb-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module) |
| 0231A8JR | 0231A8JR - R4900LCG5 Server |
| 0231A8JU | 0231A8JU - R4900LCG5 Server |
| 0231A8JV | UN-FC-HBA-QLE2692-16Gb-2P-1 - 2-port 16Gb Fibre Channel HBA card (with two SFP+ modules) |
| 0231AGHH | UN-FC-HBA-LPe35000-LP-32Gb-1P - 1-port 32Gb Optical Interface LPe35000 AIC FC HBA card (PCIe 4.0) (comes with one SFP+ optical module) (CTO&BTO) |
| 0231AGHJ | UN-FC-HBA-LPe35002-LP-32Gb-2P - 2-port 32Gb Optical Interface LPe35002 AIC FC HBA card (PCIe 4.0) (comes with two SFP+ optical modules) (CTO&BTO) |
| 0231AM7K | UN-FC-HBA-LPe31000-LP-16G-1P - 1-port 16Gb Optical Interface LPe31000 FC HBA card (PCIe 3.0) (with one SFP+ optical module) (CTO&BTO) |
| 0231AM7L | UN-FC-HBA-LPe31002-LP-16G-2P - 2-port 16Gb Optical Interface LPe31002 FC HBA card (PCIe 3.0) (with two SFP+ optical modules) (CTO&BTO) |
| Security Hardware | |
| 0231AG60 | UN-TCM-SPI-A - H3C server platform trusted module SPI TCM (CTO&BTO) |
| 0231AG5Y | UN-TPM-SPI-A - H3C server series trusted platform module SPI TPM (CTO&BTO) |
| Rack Rail | |
| 0231APX9 | UN-RL-G-G6 - G6 2U/1U Ball Screw Guide Rails (CTO & BTO) |
| 0231AFT2 | UN-RL-B-G5 - G5 2U/1U Standard Slides (CTO & BTO) |
| 0231AF5B | UN-RL-G-G5 - G5 2U/1U Ball-Bearings Slides (CTO & BTO) |
| Cable Management Tray | |
| 2150A0EE | CMA-2U-A - 2U Cable Management Rack |
| 0231AQCE | UN-CMA-2U-G6 - G6 2U Cable Management Rack (CTO & BTO) |
| Liquid Leak Power-Off Policy | |
| CPULNEED | CPULNEED - R4900LCG5 Server |
| Is customization Required? | |
| CUSTNEED | CUSTNEED - R4900LCG5 Server |
| Customized module | |
| 0231A8A6 | UN-CTM-G3-F - H3C customer-specific customization module (1H) (FIO) |
| Operating System Compatibility Verification | |
| BATJOSXX | BATJOSXX - R4900LCG5 Server |
| OSCHECKX | OSCHECKX - R4900LCG5 Server |
| Cloud and intelligent software | |
| CAS7XXXX | CAS7XXXX - R4900LCG5 Server |
| CLDSTOR3 | CLDSTOR3 - R4900LCG5 Server |
| CLDSTOR5 | CLDSTOR5 - R4900LCG5 Server |
| UIS7XXXX | UIS7XXXX - R4900LCG5 Server |
| UIS8XXXX | UIS8XXXX - R4900LCG5 Server |
| WKSPACE5 | WKSPACE5 - R4900LCG5 Server |
| Distributed storage software | |
| ONESTOS3 | ONESTOS3 - R4900LCG5 Server |
| ONESTOS5 | ONESTOS5 - R4900LCG5 Server |
| Windows | |
| 2016R0HY | 2016R0HY - R4900LCG5 Server |
| 2019R0HY | 2019R0HY - R4900LCG5 Server |
| WNDS2016 | WNDS2016 - R4900LCG5 Server |
| 2019R0XX | 2019R0XX - R4900LCG5 Server |
| 2022R0XX | 2022R0XX - R4900LCG5 Server |
| linux | |
| ALIOS7U2 | ALIOS7U2 - R4900LCG5 Server |
| BGCLE211 | BGCLE211 - R4900LCG5 Server |
| BGCLE221 | BGCLE221 - R4900LCG5 Server |
| ORACLN79 | ORACLN79 - R4900LCG5 Server |
| ORACLN82 | ORACLN82 - R4900LCG5 Server |
| ORACLN83 | ORACLN83 - R4900LCG5 Server |
| ORACLN84 | ORACLN84 - R4900LCG5 Server |
| ORACLN85 | ORACLN85 - R4900LCG5 Server |
| ORACLN86 | ORACLN86 - R4900LCG5 Server |
| ORACLN90 | ORACLN90 - R4900LCG5 Server |
| 79ENTHAT | 79ENTHAT - R4900LCG5 Server |
| 810ENHAT | 810ENHAT - R4900LCG5 Server |
| 82ENTHAT | 82ENTHAT - R4900LCG5 Server |
| 83ENTHAT | 83ENTHAT - R4900LCG5 Server |
| 84ENTHAT | 84ENTHAT - R4900LCG5 Server |
| 85ENTHAT | 85ENTHAT - R4900LCG5 Server |
| 86ENTHAT | 86ENTHAT - R4900LCG5 Server |
| 87ENTHAT | 87ENTHAT - R4900LCG5 Server |
| 88ENTHAT | 88ENTHAT - R4900LCG5 Server |
| 89ENTHAT | 89ENTHAT - R4900LCG5 Server |
| 90ENTHAT | 90ENTHAT - R4900LCG5 Server |
| 91ENTHAT | 91ENTHAT - R4900LCG5 Server |
| 92ENTHAT | 92ENTHAT - R4900LCG5 Server |
| ROCKYL84 | ROCKYL84 - R4900LCG5 Server |
| ROCKYL86 | ROCKYL86 - R4900LCG5 Server |
| ROCKYL87 | ROCKYL87 - R4900LCG5 Server |
| ROCKYL88 | ROCKYL88 - R4900LCG5 Server |
| ROCKYL89 | ROCKYL89 - R4900LCG5 Server |
| ROCKYL90 | ROCKYL90 - R4900LCG5 Server |
| ROCKYL91 | ROCKYL91 - R4900LCG5 Server |
| ROCKYL92 | ROCKYL92 - R4900LCG5 Server |
| SLE12SP5 | SLE12SP5 - R4900LCG5 Server |
| SLE15SP2 | SLE15SP2 - R4900LCG5 Server |
| SLE15SP3 | SLE15SP3 - R4900LCG5 Server |
| UB1845HK | UB1845HK - R4900LCG5 Server |
| UB1846HK | UB1846HK - R4900LCG5 Server |
| UBSE204X | UBSE204X - R4900LCG5 Server |
| UBSE2041 | UBSE2041 - R4900LCG5 Server |
| UBSE2042 | UBSE2042 - R4900LCG5 Server |
| UBSE2044 | UBSE2044 - R4900LCG5 Server |
| UBSE2046 | UBSE2046 - R4900LCG5 Server |
| UBSE2245 | UBSE2245 - R4900LCG5 Server |
| O2003S2X | O2003S2X - R4900LCG5 Server |
| O2003S2B | O2003S2B - R4900LCG5 Server |
| HyperVisors | |
| CASE0706 | CASE0706 - R4900LCG5 Server |
| CTXS82XX | CTXS82XX - R4900LCG5 Server |
| VMES67U3 | VMES67U3 - R4900LCG5 Server |
| VMES70U2 | VMES70U2 - R4900LCG5 Server |
| VMES70U3 | VMES70U3 - R4900LCG5 Server |
| VMES8064 | VMES8064 - R4900LCG5 Server |
| VMES80U1 | VMES80U1 - R4900LCG5 Server |
| VMES80U2 | VMES80U2 - R4900LCG5 Server |
| Community/Regional Enabled Oss | |
| CENTOS79 | CENTOS79 - R4900LCG5 Server |
| CENTOS82 | CENTOS82 - R4900LCG5 Server |
| CENTOS83 | CENTOS83 - R4900LCG5 Server |
| CENTOS84 | CENTOS84 - R4900LCG5 Server |
| CENTOS85 | CENTOS85 - R4900LCG5 Server |
| Zhongbiao Kylin | |
| HNQL32XX | HNQL32XX - R4900LCG5 Server |
| ZBQL10X1 | ZBQL10X1 - R4900LCG5 Server |
| ZBQL10X2 | ZBQL10X2 - R4900LCG5 Server |
| ZBQLGF76 | ZBQLGF76 - R4900LCG5 Server |
| Zhongke Hongqi | |
| ZKHQAS79 | ZKHQAS79 - R4900LCG5 Server |
| ZKHQA7U8 | ZKHQA7U8 - R4900LCG5 Server |
| ZKHQAS80 | ZKHQAS80 - R4900LCG5 Server |
| Other Operating Systems | |
| NINGV312 | NINGV312 - R4900LCG5 Server |
| OTHERSOS | OTHERSOS - R4900LCG5 Server |
| Product Identity | |
| Brand | H3C |
| Series | H3C R4900LC G5 rack server |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Optical Drive specification for UN-R4900LC-G5-SFF-C?
What is the Authentication specification for UN-R4900LC-G5-SFF-C?
What is the Model specification for UN-R4900LC-G5-SFF-C?
What is the Product Code specification for UN-R4900LC-G5-SFF-C?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?