ITMall,Your IT Global Procurement Service Expert
H3C UN-R4950-G6-SFF-LC-C
Brand H3C
N/AVerified

H3C UN-R4950-G6-SFF-LC-C

Model (MPN)
0235A4P6
Condition
Factory Sealed
Original Packaging (NIB)
Out of Stock

H3C UN-R4950-G6-SFF-LC-C Uni Server R4950 G6 SFF cold-plate liquid-cooling CTO server. GPU Support: Supported up to 4 dual-width or 10 single-width GPU cards, Note: For liquid-cooling models Supported 3 dual-width or 9 single-width GPU cards. Processor: Supports 2 AMD EPYC 9004 series processors, up to 128 cores per processor, maximum third-level cache 1152MB, maximum power 400W. Memory: Supports up to 24 DDR5 memory

Key Specifications

DescriptionH3C Uni Server R4950 G6 SFF cold-plate liquid-cooling CTO server
Dimensions/Chassis Size2U chassis: chassis dimensions (excluding the safety panel) (H x W x D): 87.5mm x 445.4mm x 780.0mm; chassis dimensions (including the safety panel) (H x W x D): 87.5mm x 445.4mm x 808.0mm
Power Supply and CoolingAir-cooled model: 5°C to 40°C; liquid-cooled model: 5°C to 50°C (operating temperature support is affected by different configurations; refer to the detailed product technical documentation for details)
operating temperatureSupports CPU liquid cooling and Optional Platinum-grade redundant power supplies of 1300W/1600W/2000W/2400W; supports 1+1 redundant, hot-swappable redundant fans
ProcessorSupports 2 AMD EPYC 9004 series processors, up to 128 cores per processor, maximum third-level cache 1152MB, maximum power 400W
MemorySupports up to 24 DDR5 memory slots, data rate up to 4800MT/s, supports RDIMM or 3DS RDIMM, maximum memory capacity 6TB
Your Price
Best Value
$178.50
List Price: $1,785.00Save 90%
Availability Out of Stock
Quantity

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Secure Payment
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Overview

H3C UN-R4950-G6-SFF-LC-C Uni Server R4950 G6 SFF cold-plate liquid-cooling CTO server

Specifications

Catalog Description
DescriptionH3C Uni Server R4950 G6 SFF cold-plate liquid-cooling CTO server
Key Specifications
Dimensions/Chassis Size2U chassis: chassis dimensions (excluding the safety panel) (H x W x D): 87.5mm x 445.4mm x 780.0mm; chassis dimensions (including the safety panel) (H x W x D): 87.5mm x 445.4mm x 808.0mm
Power Supply and CoolingAir-cooled model: 5°C to 40°C; liquid-cooled model: 5°C to 50°C (operating temperature support is affected by different configurations; refer to the detailed product technical documentation for details)
operating temperatureSupports CPU liquid cooling and Optional Platinum-grade redundant power supplies of 1300W/1600W/2000W/2400W; supports 1+1 redundant, hot-swappable redundant fans
ProcessorSupports 2 AMD EPYC 9004 series processors, up to 128 cores per processor, maximum third-level cache 1152MB, maximum power 400W
MemorySupports up to 24 DDR5 memory slots, data rate up to 4800MT/s, supports RDIMM or 3DS RDIMM, maximum memory capacity 6TB
Storage ControllerOptional RAID controller and Tri-Mode array card* based on standard PCIe slots
Product Specifications
ProcessorSupports 2 AMD EPYC 9004 series processors, up to 128 cores per processor, maximum third-level cache 1152MB, maximum power 400W
MemorySupports up to 24 DDR5 memory slots, data rate up to 4800MT/s, supports RDIMM or 3DS RDIMM, maximum memory capacity 6TB
Storage ControllerOptional RAID controller and Tri-Mode array card* based on standard PCIe slots
StorageSupported up to 41 x 2.5-inch SATA/SAS hard drives (25 front, 8 mid, 8 rear expansion). Note: For liquid-cooled models Not supported for mid hard drives Supported up to 20 x 3.5-inch SATA/SAS hard drives (12 front, 4 mid, 4 rear expansion). Note: For liquid-cooled models Not supported for mid hard drives Supported up to 28 x U.2 NVMe solid-state drives Supported up to 36 x E3.S solid-state drives (1TB) or 18 x E3.S solid-state drives (2TB)* Supported up to 40 x E1.S solid-state drives Supported up to 2 x 2280/22110 SATA/NVMe M.2 hard drives
NetworkSupports up to 2 × onboard OCP 3.0 Ethernet NICs + 1 × Optional OCP 3.0 Ethernet NIC*. Supports network adapters based on standard PCIe slots. Supports Infini Band cards. Supports smart NICs
extended slotSupported up to 10 x PCIe 5.0 available standard slots, Note: For liquid-cooling models Supported 9 x PCIe 5.0 available slots
InterfaceFront: Left bracket (Optional): 1 VGA, 1 USB3.0, 1 Type C port; Right bracket: 1 USB3.0 Built-in: 1 USB3.0 Rear: 1 VGA, 1 serial port (Optional), 2 USB3.0, 1 HDMI dedicated network port liquid cooling interface: through UQD04 male or flexible hose + UQD04 female at the rear of the chassis window
GPU SupportSupported up to 4 dual-width or 10 single-width GPU cards, Note: For liquid-cooling models Supported 3 dual-width or 9 single-width GPU cards
ManagementHDM agentless management tool (with dedicated management port) and H3C FIST management software; supports LCD touch intelligent management module
SecuritySupports chassis intrusion detection, TCM/TPM security module, and CPU-embedded dedicated security processor
Power Supply and CoolingAir-cooled model: 5°C to 40°C; liquid-cooled model: 5°C to 50°C (operating temperature support is affected by different configurations; refer to the detailed product technical documentation for details)
AuthenticationSupports CCC, CECP, SEPAetc.Authentication
operating temperatureSupports CPU liquid cooling and Optional Platinum-grade redundant power supplies of 1300W/1600W/2000W/2400W; supports 1+1 redundant, hot-swappable redundant fans
Dimensions/Chassis Size2U chassis: chassis dimensions (excluding the safety panel) (H x W x D): 87.5mm x 445.4mm x 780.0mm; chassis dimensions (including the safety panel) (H x W x D): 87.5mm x 445.4mm x 808.0mm
Warranty3-year 5x9 support, next business day response (NBD)
Ordering Information
Processor
0231AKB8UN-CPU-AMD-9654 - AMD Genoa 9654 (2.4GHz/96 cores/384MB/360W) CPU module (CTO&BTO)
0231AKB9UN-CPU-AMD-9174F - AMD Genoa 9174F (4.1GHz/16-core/256MB/320W) CPU module (CTO&BTO)
0231AKDNUN-CPU-AMD-9224 - AMD Genoa 9224 (2.5GHz/24-core/64MB/200W) CPU module (CTO&BTO)
0231ALBNUN-CPU-AMD-9334 - AMD Genoa 9334 (2.7GHz/32-core/128MB/210W) CPU module (CTO&BTO)
0231ALDQ0231ALDQ - AMD Genoa 9534 (2.45GHz/64 cores/256MB/280W) CPU module (CTO&BTO)
0231ALDRUN-CPU-AMD-9554 - AMD Genoa 9554 (3.1GHz/64-core/256MB/360W) CPU module (CTO&BTO)
0231ALFAUN-CPU-AMD-9454 - AMD Genoa 9454 (2.75GHz/48-core/256MB/290W) CPU module (CTO&BTO)
0231ALFG0231ALFG - AMD Genoa 9634 (2.25GHz/84 cores/384MB/290W) CPU module (CTO&BTO)
0231ALK5UN-CPU-AMD-9124 - AMD Genoa 9124 (3.0GHz/16-core/64MB/200W) CPU module (CTO&BTO)
0231ALK6UN-CPU-AMD-9274F - AMD Genoa 9274F (4.05GHz/24-core/256MB/320W) CPU module (CTO&BTO)
0231ALK7UN-CPU-AMD-9374F - AMD Genoa 9374F (3.85GHz/32-core/256MB/320W) CPU module (CTO&BTO)
0231ALK8UN-CPU-AMD-9354 - AMD Genoa 9354(3.25GHz/32 cores/256MB/280W)CPU module(CTO&BTO)
0231ALK9UN-CPU-AMD-9254 - AMD Genoa 9254(2.9GHz/24 cores/128MB/200W)CPU module(CTO&BTO)
0231ALKAUN-CPU-AMD-9474F - AMD Genoa 9474F(3.6GHz/48 cores/256MB/360W)CPU module(CTO&BTO)
0231AM96UN-CPU-AMD-9754 - AMD Bergamo 9754 (2.25GHz/128 cores/256MB/360W) CPU module (CTO&BTO)
0231AM970231AM97 - AMD Bergamo 9734 (2.2GHz/112 cores/256MB/340W) CPU module (CTO&BTO)
0231AMKX0231AMKX - AMD Genoa-X 9184X(3.55GHz/16 cores/768MB/320W) CPU module(CTO&BTO)
0231AMKY0231AMKY - AMD Genoa-X 9384X(3.1GHz/32 cores/768MB/320W) CPU module(CTO&BTO)
0231AML00231AML0 - AMD Genoa-X 9684X(2.55GHz/96 cores/1152MB/400W) CPU module(CTO&BTO)
Memory
0231AK7X0231AK7X - 64GB 2RX4 DDR5-4800 RDIMMMemory Module(CTO&BTO)
0231ALG50231ALG5 - R4950 G6 Server
0231ALV9UN-DDR5-4800B-128G-4Rx4-R - 128GB 4Rx4 DDR5-4800B 3DS CAS-46-39-39 RDIMMMemory Module(CTO&BTO)
0231ALVA0231ALVA - 16GB 1Rx8 DDR5-4800B CAS-40-39-39 RDIMMMemory Module(CTO&BTO)
0231AM1XUN-DDR5-4800B-64G-2Rx4-R-2 - 64GB 2Rx4 DDR5-4800B(CAS-40-39-39)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AM23UN-DDR5-4800B-16G-1Rx8-R-2 - 16GB 1Rx8 DDR5-4800B(CAS-40-39-39)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AM4CUN-DDR5-4800B-96G-2Rx4-R-2 - 96GB 2RX4 DDR5-4800B CAS-40-39-39 SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AM4EUN-DDR5-4800B-96G-2Rx4-R - 96GB 2RX4 DDR5-4800B CAS-40-39-39 RDIMMMemory Module(CTO&BTO)
0231AMLJUN-DDR5-5600B-64G-2Rx4-R-2 - 64GB 2Rx4 DDR5-5600B(CAS-46-45-45)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AMLYUN-DDR5-5600B-64G-2Rx4-R - 64GB 2Rx4 DDR5-5600B(CAS-46-45-45)RDIMMMemory Module(CTO&BTO)
0231AMM1UN-DDR5-5600B-32G-2Rx8-R-2 - 32GB 2Rx8 DDR5-5600B(CAS-46-45-45)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AMMEUN-DDR5-5600B-96G-2Rx4-R-2 - 96GB 2Rx4 DDR5-5600B(CAS-46-45-45)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO)
0231AMMTUN-DDR5-5600B-96G-2Rx4-R - 96GB 2Rx4 DDR5-5600B(CAS-46-45-45)RDIMMMemory Module(CTO&BTO)
0231APKAUN-DDR5-5600B-128G-2Rx4-R - 128GB 2Rx4 DDR5-5600B (CAS-46-45-45) RDIMMMemory Module(CTO&BTO)
Dummy Memory
0231AK76UN-DUMMY-DIMM-DDR5-M - DDR5 dummy memory module (CMCTO)
Front Hard Drive Cage
0231AP95UN-PCA-BP-25SFF-A-2U-G6 - G6 2U front 25SFF drive backplane module (applicable to AMD) (CTO&BTO)
0231AJPUUN-PCA-BP-8SFF-2U-G6 - G6 2U front 8SFF hard drive backplane module (CTO&BTO)
0231AP93UN-PCA-BP-8UniBay-A-2U-G6 - G6 2U front 8Uni Bay drive backplane module (applicable to AMD) (CTO&BTO)
Rear Hard Drive Cage
0231AK88UN-HDDCage-2SFF-2U-G6 - G6 2U rear 2SFF drive cage module(CTO&BTO)
0231AP8UUN-HDDCage-2UniBay-A-2U-G6 - G6 2U rear 2 Uni Bay drive cage module (for AMD) (CTO&BTO)
0231AK86UN-HDDCage-4SFF-2U-G6 - G6 2U rear 4SFF drive cage module(CTO&BTO)
0231AP8VUN-HDDCage-4UniBay-A-2U-G6 - G6 2U rear 4 Uni Bay hard drive cage module (applicable to AMD) (CTO&BTO)
Diagnostics Panel
0231AE9YUN-SID-LCD-SFF-M - SFF LCD panel module (CMCTO)
Riser Slot 1
0231AJQ9UN-RC-3FHHL-2U-G6 - G6 2U Riser1/Riser2 X16X8X8 Riser (supports 3x 75W GPU) (CTO&BTO)
0231AJQFUN-RC-3FHFL-2U-G6 - G6 2U Riser1/Riser2 3X16 Riser(supports 2x150W GPUs and 1x FHHL)(CTO&BTO)
0231AK6UUN-RC-2FHHL-2U-G6 - G6 2U Riser1/Riser2 2X8 Riser(supports 2x FHHL modules)(CTO&BTO)
0231AK8EUN-RC-1FHHL-2U-G6 - G6 2U Riser1/Riser2 X16 Riser (Supports 1x FHHL module) (CTO&BTO)
Riser Slot 2
0231ALYKUN-RC-2FHFL-2U-LC-G6 - G6 2U Riser2 2X16 Riser (supports 2x FHFL, supports liquid cooling) (CTO&BTO)
Hard Disk Array Controller Card (Requires a PCIe Adapter Card)
0231A8NDUN-HBA-H460-B1-F - H460-B1 12G SAS HBA card module (supports 8 SAS ports, PCIe) (CMCTO)
0231A8P1UN-RAID-P460-B4-F - P460-B4 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, excluding supercapacitor) (CMCTO)
0231AAUF0231AAUF - P460-B2 12G SAS RAID card module (supports 8 SAS ports, with 2GB cache, excluding supercapacitor) (CMCTO)
0231AEVLUN-RAID-LSI-9560-LP-16i-8GB-M - LSI 9560-16i 12G SAS RAID card module (supports 16x SAS Ports, with 8GB cache, PCIe, excludes supercapacitor) (CMCTO)
0231AG62UN-RAID-LSI-9560-LP-8i-4GB - LSI 9560-8i 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, PCIe, without supercapacitor) (CTO&BTO)
0231AJ69UN-HBA-LSI-9540-LP-8i - LSI 9540-8i 12G SAS HBA card module (supports 8 SAS Ports, PCIe) (CTO&BTO)
0231AJ6EUN-HBA-LSI-9500-LP-8i - LSI 9500-8i 12G SAS HBA card module (supports 8x SAS Ports, PCIe) (CTO&BTO)
0231AJ6MUN-HBA-LSI-9500-LP-16i - LSI 9500-16i 12G SAS HBA card module (supports 16x SAS Ports, PCIe) (CTO&BTO)
M.2 Adapter Card
0231AKB0UN-RAID-MARVELL-M.2 - MARVELL SATA M.2 RAID card (supports 2 M.2 SATA Ports, supports M.2 hot-swap, PCIe) (CTO&BTO)
0231AF5QUN-RC-2M2-G5 - G5 front 2*M.2 2280/22110 Riser module(CTO&BTO)
M.2 SSD
0231AK1R0231AK1R - 480GB 6G SATA RI 5400PRO M.2 SSDHard Drive Module(CTO&BTO)
0231AES60231AES6 - R4950 G6 Server
0231AHCQUN-SSD-480G-SATA-S4520-M.2 - 480GB SATA RI S4520 M.2 SSDHard Drive Module(CTO&BTO)
0231AES40231AES4 - R4950 G6 Server
OCP Slot 1
0231AKMHUN-NIC-BCM957508-N2100G-3S-2P - 2-Port100Gb QSFP56optical interfaceBCM957508-N2100G OCP3.0Network Adapter(CTO&BTO)
Optical Module
0231AC16QSFP-100G-SR4-MM850-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO)
0231AGFLUN-NIC-ETH-MCX623436AN-CDAB-2P - 2-Port100Gb optical interfaceMCX623436AN-CDAB OCP3.0Network Adapter(CTO&BTO)
0231AEBX0231AEBX - R4950 G6 Server
0231A8KBUN-SFP-XG-SX-MM850-E1 - SFP+ 10GModule(850nm,300m,LC)
0231AC0TSFP-XG-LX-SM1310-CM - SFP+ 10GModule(1310nm,10km,LC)(FIO)
0231AEBYUN-NIC-ETH561F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter(CTO&BTO)
0231AEBVUN-NIC-ETH565T-3S-2P - 2-Port10GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO)
0231AEBWUN-NIC-ETH640F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO)
0231A7N6SFP-25G-SR-MM850-1 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC)
0231AFH3UN-NIC-ETH660F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO)
0231AG96UN-NIC-ETH-MCX631432AN-ADAB-2P - 2-Port25Gb SFP28optical interfaceMCX631432AN OCP3.0Network Adapter(CTO&BTO)
0231AEBUUN-NIC-ETH360T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO)
OCPSlot2
Network Card (Requires PCIe Adapter Card)
0231A7GN0231A7GN - 2-Port25GEoptical interface Network Adapter(SFP+)(FIO)
0231A7NHUN-NIC-620F-B2-25Gb-2P-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2
0231A7PXUN-NIC-BCM957416-T-B-10Gb-2P-F - 2-Port10GEelectrical interface Network Adapter(BCM957416)(FIO)
0231A7Q2UN-NIC-BCM957414-F-B-25Gb-2P-F - 2-Port25GEoptical interface Network Adapter(BCM957414)(FIO)
0231A7WCUN-NIC-X710DA4-F-B-10Gb-4P-F - 4-Port10GEoptical interface Network Adapter(SFP+)(FIO)
0231A8K1UN-NIC-GE-4P-360T-B2-1 - 4-Port Gigabitelectrical interface Network Adapter-360T-B2
0231A8K2UN-CNA-10GE-2P-560F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-560F-B2
0231A8K9UN-NIC-10GE-2P-530F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-530F-B2
0231A9AUUN-NIC-X710DA2-F-B-10Gb-2P-F2 - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO)
0231AB5WUN-NIC-MCX512A-ACAT-F-2*25Gb-F - 2-Port25Gboptical interface Network Adapter(SFP28)(MCX512A-ACAT)(FIO)
0231ADWS0231ADWS - 2-Port100GEoptical interface Network Adapter(QSFP28)(CTO&BTO)
0231AF8AUN-NIC-X2522-25Gb-2P-M - 2-port 25Gb SFP28 Optical Interface X2522-25G-PLUS low-latency network card (CTO&BTO)
0231AFH5UN-NIC-ETH630F-LP-2P - 2-Port25GEoptical interface Network Adapter (ETH630F)(CTO&BTO)
0231AFN8UN-IB-MCX653105A-HDAT-200Gb-1P - 200Gb 1-Port Infini Band HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO)
0231AFRVUN-NIC-ETH531F-LP-2P - 2-Port10GEoptical interface Network Adapter(CTO&BTO)
0231AFUGUN-NIC-ETH-MCX631102AN-ADAT - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO)
0231AFUR0231AFUR - R4950 G6 Server
0231AFUPUN-CAB-IB-DAC-MCP7H50-V002R26-2m - Mellanox 2m HDR100 100G DAC breakout cable (CTO&BTO)
0231AFUSUN-IB-MCX653106A-ECAT-100Gb-2P - 100Gb 2-Port Infiniband HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO)
0231AG88UN-NIC-ETH-E810XXVDA2G1P5-2P - 2-port 25Gb SFP28 Optical Interface E810XXVDA2G1P5 Ethernet card (CTO&BTO)
0231AGJAUN-NIC-ETH-MCX623106AN-CDAT-2P - 2-Port100Gb QSFP56optical interfaceMCX623106AN-CDATNetwork Adapter(CTO&BTO)
Graphics card (requires a PCIe adapter card)
0231AJFSUN-GPU-A16-64G-DW - NVIDIA A16 64G GPUModule(CTO&BTO)
0231AKCL0231AKCL - R4950 G6 Server
0231ANF4UN-GPU-48GB-DW - NVIDIA 48G PCIe4.0 X16 FHFL GPUModule(CTO&BTO)
0231ALL70231ALL7 - R4950 G6 Server
0231ALLAUN-GPU-L40-48GB - NVIDIA L40 48G GPUModule(CTO&BTO)
0231AG9XUN-GPU-A10-24G - NVIDIA Tesla A10 24G GPUModule(Non-CEC)(CTO&BTO)
0231ANMC0231ANMC - Nvidia L2 24G PCIe4.0 X16 HHHL GPUModule(CTO&BTO)
0231AJWAUN-GPU-A2-16GB-NoCEC - Nvidia Tesla A2 16GB Non-CEC GPUModule(CTO&BTO)
0231AK450231AK45 - R4950 G6 Server
0231AJWD0231AJWD - R4950 G6 Server
0231ABT8UN-GPU-T4-F - T4 Display Acceleration Card (FIO)
Fiber Channel HBA card (requires PCIe adapter card)
0231A7LNUN-FC-HBA-LPe32002-32Gb-2P - 2-port 32Gb optical fiber channel HBA card (with two SFP+ optical modules)
0231A7NBUN-HBA-16Gb-LPe31000-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module)
0231A7NFUN-HBA-16Gb-LPe31002-2P-1 - 2-port 16Gb Fibre Channel HBA card (with two SFP+ modules)
0231A8JQUN-FC-HBA-QLE2690-16Gb-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module)
0231AGHHUN-FC-HBA-LPe35000-LP-32Gb-1P - 1-port 32Gb Optical Interface LPe35000 AIC FC HBA card (PCIe 4.0) (comes with one SFP+ optical module) (CTO&BTO)
0231AGHJUN-FC-HBA-LPe35002-LP-32Gb-2P - 2-port 32Gb Optical Interface LPe35002 AIC FC HBA card (PCIe 4.0) (comes with two SFP+ optical modules) (CTO&BTO)
0231ANQ1UN-FC-HBA-LPe36002-LP-64G-2P - 2-port 64Gb PCIe4.0 X8 SFP+ Optical Interface LPe36002 LP FC HBA card (with two SFP+ optical modules) (CTO&BTO)
0231ANQ2UN-FC-HBA-LPe36000-LP-64G-1P - 1-port 64Gb PCIe4.0 X8 SFP+ Optical Interface LPe36000 LP FC HBA card (with one SFP+ optical module) (CTO&BTO)
i Fist Module
0231AJQ5UN-IFIST-EX-G6 - G6 iFISTModule(CTO&BTO)
Power Supply
0231AGUPUN-GW-CRPS1300D3 - 1300W AC&240V HVDC power Module (GW-R1-Platinum-low load high efficiency) (CTO&BTO)
0231AJYBUN-PS-2132-5L5 - 1300W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO)
0231ACTGFSP1600-20FH-M - 1600W 336V HVDC power Supply Module (dedicated power cable) (FP-R1- Platinum) (CMCTO)
0231AHRVUN-DD-2162-3L5 - 1600W 48V DC power Supply Module (LT-R1- Platinum) (CTO&BTO)
0231AMKUUN-GW-CRPS1600C2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Titanium) (CTO&BTO)
0231AGUNUN-GW-CRPS1600D2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Platinum) (CTO&BTO)
0231ACTADPS-1600AB-13 R-M - 1600W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO)
0231AFSSUN-GW-CRPS2000D - 2000W AC & 240V HVDC power Supply Module (GW-R2- Platinum - light-load high efficiency) (CTO&BTO)
0231AHRUUN-PS-2202-11L - 2000W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO)
0231AFQBUN-DPS-2400EB B - 2400W AC & 240V HVDC power Supply Module (DT-R1-Platinum) (CTO&BTO)
0231ANVFUN-CRPS3200-AC12-Ti-B1-GW - 3200W AC & 240V HVDC power Module (GW-R1-Titanium) (CTO&BTO)
No-power-cord power supply
0231ALYSUN-CRPS-1300W-AC-12V-94%-M2 - 1300W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO)
0231AMPJUN-CRPS-1600W-AC-12V-94%-M - 1600W AC & 240V HVDC power supply (Platinum) (CMCTO)
0231AMQ7UN-CRPS-2000W-AC-12V-94%-M - 2000W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO)
Power Supply Cable
0404A0K4CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard
0404A19YCAB-AC Pwr-3m-C19-CHE - R4950 G6 Server
0404A06QCAB-AC Pwr CHI-1.8m - Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard
04040890CAB-AC Pwr EN&SI-3m - Wall power outlet AC power cable - 3.0m - 1.0mm^2 - black - (BS1363A plug (3P) right-angle male 250V13A) - (H05VV-F) - (C13 connector (3P) straight female 250V10A) - UK standard
0404A0MWCAB-AC-16A-PDU-3m-Eu - PDU Power Supply Cable - 3.0 m - 1.5 mm² - Black - (C20 Connector (3P) Straight Male 250 V 16 A) - (H05VV-F) - (C19 Connector (3P) Straight Female 250 V 16 A) - European Standard
Fan
0231AJPXUN-FAN-8038-2U-G6 - G6 2U 8038Fan Module(CTO&BTO)
0231AJPTUN-FAN-8056-2U-G6 - G6 2U 8056Fan Module(CTO&BTO)
Air Deflector
0231AK71UN-FAN-COVER-OCP-G6 - G6 OCP dedicated air duct shroud module (CTO&BTO)
0231AK72UN-FAN-COVER-OCP-FAN-G6 - G6 OCP air-duct shroud module with fans (CTO&BTO)
0231ANLMUN-ME-GPU-Kit - GPU Accessories Kit (CTO & BTO)
0231AKB6UN-FAN-COVER-3GPU-R4950G6 - H3C Uni Server R4950 G6 dedicated 3GPU airflow baffle module (CTO&BTO)
2120A09RUN-ME-Air Baffle-R1-S2-G6 - H3C Uni Server R4950 G6 Riser1 Slot2 airflow baffle module
CPU Cooler
0231ALXX0231ALXX - R4950 G6 Server
0231ALXYUN-R4950-G6-LC-CPU-UQD04 - H3C Uni Server R4950 G6 CPU liquid-cooling heat dissipation module (soft tubing direct outlet) (CTO&BTO)
0231ALY00231ALY0 - R4950 G6 Server
0231ALY10231ALY1 - R4950 G6 Server
Security Hardware
0231AG60UN-TCM-SPI-A - H3C server platform trusted module SPI TCM (CTO&BTO)
0231AG5YUN-TPM-SPI-A - H3C server series trusted platform module SPI TPM (CTO&BTO)
Ear Hook
0231AKB3UN-EAR-QE-2U-LEFT-R4950G6 - H3C Uni Server R4950 G6 2U intelligent left ear component (CTO&BTO)
Security Panel
0231AFTBUN-SEC-Panel-2U-G5 - H3C Uni Server G5 2U intelligent security panel (CTO&BTO)
Rack Rail
0231APX9UN-RL-G-G6 - G6 2U/1U Ball Screw Guide Rails (CTO & BTO)
0231AFT2UN-RL-B-G5 - G5 2U/1U Standard Slides (CTO & BTO)
0231AF5BUN-RL-G-G5 - G5 2U/1U Ball-Bearings Slides (CTO & BTO)
Cable Management Tray
2150A0EECMA-2U-A - 2U Cable Management Rack
0231AQCEUN-CMA-2U-G6 - G6 2U Cable Management Rack (CTO & BTO)
Tag
0231AGWUUN-Label-Shock&Tilt Monitor - Anti-tilt label and 37G anti-vibration label (CTO&BTO)
Is customization Required?
CUSTNEEDCUSTNEED - R4950 G6 Server
LCOUTAGELCOUTAGE - R4950 G6 Server
Customized module
0231A8A6UN-CTM-G3-F - H3C customer-specific customization module (1H) (FIO)
Installing Services
8814A0KVSV-PS-US-INST - H3C Server first-time basic installation service - for overseas business only
8814A16PSV-PS-LC-SIMS - Liquid-cooling rack installation and maintenance service
Operating System Compatibility Verification
BATJOSXXBATJOSXX - R4950 G6 Server
OSCHECKXOSCHECKX - R4950 G6 Server
Windows
2019R0XX2019R0XX - R4950 G6 Server
2022R0XX2022R0XX - R4950 G6 Server
linux
ALINOS89ALINOS89 - R4950 G6 Server
H3LX202SH3LX202S - R4950 G6 Server
H3LXV202H3LXV202 - R4950 G6 Server
86ENTHAT86ENTHAT - R4950 G6 Server
87ENTHAT87ENTHAT - R4950 G6 Server
88ENTHAT88ENTHAT - R4950 G6 Server
89ENTHAT89ENTHAT - R4950 G6 Server
90ENTHAT90ENTHAT - R4950 G6 Server
91ENTHAT91ENTHAT - R4950 G6 Server
92ENTHAT92ENTHAT - R4950 G6 Server
ROCKYL86ROCKYL86 - R4950 G6 Server
ROCKYL88ROCKYL88 - R4950 G6 Server
ROCKYL90ROCKYL90 - R4950 G6 Server
ROCKYL92ROCKYL92 - R4950 G6 Server
ROCKYL93ROCKYL93 - R4950 G6 Server
SLE15SP4SLE15SP4 - R4950 G6 Server
UBSE2045UBSE2045 - R4950 G6 Server
UBSE224XUBSE224X - R4950 G6 Server
O223LTS1O223LTS1 - R4950 G6 Server
O223LTS3O223LTS3 - R4950 G6 Server
O2403LTSO2403LTS - R4950 G6 Server
HyperVisors
CASE0760CASE0760 - R4950 G6 Server
CASE0780CASE0780 - R4950 G6 Server
CTXS82XXCTXS82XX - R4950 G6 Server
CTXXS82XCTXXS82X - R4950 G6 Server
VMES70U3VMES70U3 - R4950 G6 Server
VMES8064VMES8064 - R4950 G6 Server
VMES80U1VMES80U1 - R4950 G6 Server
VMES80U2VMES80U2 - R4950 G6 Server
Zhongbiao Kylin
ZBQL10S3ZBQL10S3 - R4950 G6 Server
Other Operating Systems
NINGV312NINGV312 - R4950 G6 Server
OTHERSOSOTHERSOS - R4950 G6 Server
License Fees
3130A66XLIS-HDM-FORMAL-SERVER - H3C advanced feature license fee (CTO&BTO)
Product Identity
BrandH3C
SeriesH3C R4950 G6 rack server

Reviews

No reviews yet

Be the first to review this enterprise product.

Warranty

Standard Warranty Policy

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects

Hassle-Free RMA Process

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues

Certified Engineering Support

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch

Global Logistics & Packaging

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Resources

No downloads available for this product.

FAQ

What is the Storage Controller specification for UN-R4950-G6-SFF-LC-C?
UN-R4950-G6-SFF-LC-C lists Storage Controller as Optional RAID controllers and Tri-Mode array cards based on standard PCIe slots*. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Authentication specification for UN-R4950-G6-SFF-LC-C?
UN-R4950-G6-SFF-LC-C lists Authentication as Supports CCC, CECP, SEPA, and other certifications. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Warranty specification for UN-R4950-G6-SFF-LC-C?
UN-R4950-G6-SFF-LC-C lists Warranty as 3-year 5x9 support, next business day response (NBD). Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
What is the Model specification for UN-R4950-G6-SFF-LC-C?
UN-R4950-G6-SFF-LC-C lists Model as UN-R4950-G6-SFF-LC-C. Use this value when checking datasheet requirements, quotation details, and deployment compatibility.
Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Still have questions?