H3C UNIS-R4970-G7-MAL0-C UNIS Server R4970 G7 MAL0 CTOServers

H3C UNIS-R4970-G7-MAL0-C
H3C UNIS-R4970-G7-MAL0-C UNIS Server R4970 G7 MAL0 CTOServers
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | UNIS Server R4970 G7 MAL0 CTOServers |
| Ordering Information | |
| Motherboard | |
| 0231AP6T | 0231AP6T - R4970 G7 dual-socket Feiteng S5000C (64 cores @2.1GHz) motherboard (CMCTO) |
| CPU Cooler | |
| 9821A108 | UN-ME-HeatSink-2UbY-R4970G7-M - R4970 G7 Feiteng S5000C CPU Standard Cooler |
| 9821A10E | UN-ME-HeatSink-2UbLY-R4970G7-M - R4970 G7 Feiteng S5000C CPU L-Shaped Horn-Style Heatsink |
| Memory | |
| 0231AP9C | 0231AP9C - 32GB 2Rx8 DDR5-4800B(CAS-40-39-39)RDIMMMemory Module(FTZY)(CMCTO) |
| 0231AP9D | 0231AP9D - 64GB 2Rx4 DDR5-4800B(CAS-40-39-39)RDIMMMemory Module(FTZY)(CMCTO) |
| 0231AP9R | 0231AP9R - 16GB 1Rx8 DDR5-4800B(CAS-40-39-39)RDIMMMemory Module(FTZY)(CMCTO) |
| 0231AQCB | 0231AQCB - 64GB 2Rx4 DDR5-5600B(CAS-46-45-45) 1anm UniIC&Longsys RDIMMMemory Module(CMCTO) |
| 0231AR4D | 0231AR4D - UNIS R4970 G7 Servers |
| 0231AR4F | UN-DDR5-5600B-64G-2Rx4-R-FT-M - UNIS R4970 G7 Servers |
| 0231AR4G | UN-DDR5-5600B-32G-2Rx8-R-FT-M - UNIS R4970 G7 Servers |
| Fan | |
| 0231AJPT | UN-FAN-8056-2U-G6 - G6 2U 8056Fan Module(CTO&BTO) |
| BMC Module | |
| 0231ANKS | UNIS-PCA-BMC-R4970-G7-E2000S - H3C UNIS Server R4970 G7 Fei teng E2000S BMC management board module (CTO&BTO) |
| i Fist Module | |
| 0231APBH | UN-IFIST-EX-ARM-G7 - H3C Uni Server G7 ARM iFISTModule(CTO&BTO) |
| Power Supply | |
| 0231AGUP | UN-GW-CRPS1300D3 - 1300W AC&240V HVDC power Module (GW-R1-Platinum-low load high efficiency) (CTO&BTO) |
| 0231APC0 | UN-CRPS-1300W-AC-12V-C5-B1-GW - 1300W AC & 240V HVDC power Supply Module (GW-R2-CQCⅤ - low-load high-efficiency) (for SA) (CTO&BTO) |
| 0231AJYB | UN-PS-2132-5L5 - 1300W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231ACT9 | DPS-1300AB-6 R-M - 1300W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231ACTG | FSP1600-20FH-M - 1600W 336V HVDC power Supply Module (dedicated power cable) (FP-R1- Platinum) (CMCTO) |
| 0231AHRV | UN-DD-2162-3L5 - 1600W 48V DC power Supply Module (LT-R1- Platinum) (CTO&BTO) |
| 0231AMKU | UN-GW-CRPS1600C2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Titanium) (CTO&BTO) |
| 0231AMPJ | UN-CRPS-1600W-AC-12V-94%-M - 1600W AC & 240V HVDC power supply (Platinum) (CMCTO) |
| 0231AGUN | UN-GW-CRPS1600D2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Platinum) (CTO&BTO) |
| 0231APBX | UN-CRPS-1600W-AC-12V-C5-B1-GW - 1600W AC & 240V HVDC power Supply Module (GW-R2-CQCⅤ - low-load high-efficiency) (for SA) (CTO&BTO) |
| 0231ACTA | DPS-1600AB-13 R-M - 1600W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231AMQ7 | UN-CRPS-2000W-AC-12V-94%-M - 2000W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO) |
| 0231AFSS | UN-GW-CRPS2000D - 2000W AC & 240V HVDC power Supply Module (GW-R2- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231AHRU | UN-PS-2202-11L - 2000W AC & 240V HVDC power Supply Module (LT-R1- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231AFQB | UN-DPS-2400EB B - 2400W AC & 240V HVDC power Supply Module (DT-R1-Platinum) (CTO&BTO) |
| 0231APBY | UN-CRPS-800W-AC-12V-C5-B1-GW - 800W AC & 240V HVDC power Supply Module (GW-R3-CQCⅤ)(for SA)(CTO&BTO) |
| Front Hard Drive Backplane | |
| 0231AK7A | UN-PCA-BP-8LFF-2U-G6 - G6 2U front 8LFF backplane module(CTO&BTO) |
| 0231AJPN | UN-PCA-BP-12LFF-4NVMe-2U-G6 - G6 2U front 12LFF supports 4NVMe hard disk backplane module (CTO&BTO) |
| 0231AJPR | UN-PCA-BP-12LFF-2U-G6 - G6 2U front 12LFF backplane module(CTO&BTO) |
| 0231AJQ8 | UN-PCA-BP-12LFF-UniBay-2U-G6 - G6 2U front 12LFF Uni Bay hard disk backplane module (CTO&BTO) |
| 0231AK78 | UN-PCA-BP-12LFF-EXP-2U-G6 - G6 2U front 12LFF backplane module with Expander drive bay (CTO&BTO) |
| Rear Hard Drive Cage | |
| 0231AK7B | UN-HDDCage-2LFF-2U-G6 - G6 2U rear 2LFF drive cage module(CTO&BTO) |
| 0231AK88 | UN-HDDCage-2SFF-2U-G6 - G6 2U rear 2SFF drive cage module(CTO&BTO) |
| 0231AK8A | UN-HDDCage-2UniBay-2U-G6 - G6 2U rear 2SFF Uni Bay hard disk cage module (CTO&BTO) |
| 0231AK7K | UN-HDDCage-4LFF-2U-G6 - G6 2U rear 4LFF drive cage module(CTO&BTO) |
| 0231AK83 | UN-HDDCage-4UniBay-2U-G6 - G6 2U Rear 4SFF Uni Bay Drive Cage Module (CTO&BTO) |
| 0231AK86 | UN-HDDCage-4SFF-2U-G6 - G6 2U rear 4SFF drive cage module(CTO&BTO) |
| M.2 Adapter Card | |
| 0231AF5Q | UN-RC-2M2-G5 - G5 front 2*M.2 2280/22110 Riser module(CTO&BTO) |
| M.2 SSD | |
| 0231AHCQ | UN-SSD-480G-SATA-S4520-M.2 - 480GB SATA RI S4520 M.2 SSDHard Drive Module(CTO&BTO) |
| SD card | |
| 0231A6RC | UN-SD-32G-Micro-F - 32G microSD mainstream flash drive module (FIO) |
| 0231A7KC | 0231A7KC - UNIS R4970 G7 Servers |
| SD card expansion module | |
| 0231AJQE | UN-RC-DSD-UART-G6 - G6 serial port & DSD interface board (CTO&BTO) |
| 1/2-slot adapter card | |
| 0231AJQ9 | UN-RC-3FHHL-2U-G6 - G6 2U Riser1/Riser2 X16X8X8 Riser (supports 3x 75W GPU) (CTO&BTO) |
| 0231AJQF | UN-RC-3FHFL-2U-G6 - G6 2U Riser1/Riser2 3X16 Riser(supports 2x150W GPUs and 1x FHHL)(CTO&BTO) |
| 0231AK6U | UN-RC-2FHHL-2U-G6 - G6 2U Riser1/Riser2 2X8 Riser(supports 2x FHHL modules)(CTO&BTO) |
| 0231AK8E | UN-RC-1FHHL-2U-G6 - G6 2U Riser1/Riser2 X16 Riser (Supports 1x FHHL module) (CTO&BTO) |
| 3/4-slot structural modules | |
| 0231AKAV | UN-ME-2FHFL-R4-2U-EXP-G6 - Riser4 supports 2x FHFL-structure modules(CTO&BTO) |
| 0231AKBA | UN-ME-2HHHL-R3-2U-EXP-G6 - Riser3 supports 2x HHHL-structure modules(CTO&BTO) |
| Standard Control Card (PCIe Standard Card) | |
| 0231AK8J | UN-RAID-P9560-3S-8i-4GB - P9560-8i 12G SAS RAID card module (supports 8x SAS ports, with 4GB cache, excluding supercapacitor) (CTO&BTO) |
| 0231AG62 | UN-RAID-LSI-9560-LP-8i-4GB - LSI 9560-8i 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, PCIe, without supercapacitor) (CTO&BTO) |
| 0231AQWY | UN-HBA-LSI-9500-LP-8i-ARM - LSI 9500-8i 12Gb 1-port SAS HBA card (05-50134-01) (supports 8 SAS ports, PCIe, ARM) (CTO&BTO) |
| 0231AEVL | UN-RAID-LSI-9560-LP-16i-8GB-M - LSI 9560-16i 12G SAS RAID card module (supports 16x SAS Ports, with 8GB cache, PCIe, excludes supercapacitor) (CMCTO) |
| 0231AQWX | UN-HBA-LSI-9500-LP-16i-ARM - LSI 9500-16i 12Gb 2-port SAS HBA card (05-50134-00) (supports 16 SAS ports, PCIe, ARM) (CTO&BTO) |
| 0231A8P1 | UN-RAID-P460-B4-F - P460-B4 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, excluding supercapacitor) (CMCTO) |
| 0231AAUF | 0231AAUF - P460-B2 12G SAS RAID card module (supports 8 SAS ports, with 2GB cache, excluding supercapacitor) (CMCTO) |
| 0231A8ND | UN-HBA-H460-B1-F - H460-B1 12G SAS HBA card module (supports 8 SAS ports, PCIe) (CMCTO) |
| Battery | |
| 0231AEYR | UN-BAT-LSI-G3-A - LSI G3 supercapacitor module (CTO&BTO) |
| 0231AFA4 | UN-BAT-PMC-G3-2U - PMC G3 Supercapacitor Module (for 2U Standard Chassis) (CTO & BTO) |
| Graphics Card | |
| 0231AN53 | UN-GPU-BI-V150-64GB-DW - Tansun Semiconductor Tianjai 150 BI-V150 64G PCIe4.0 x16 FHFL GPU module (CTO&BTO) |
| 0231AMQH | UN-GPU-R200-8F-32GB-DW - Kunlun Xin R200-8F 32GB GPU module (CTO&BTO) |
| 0231AQMY | UN-GPU-VG1000-32GB-LP - Hanbo Semiconductor VG1000 32G PCIe4.0 x16 LP GPU module (CTO&BTO) |
| Network Adapter | |
| 0231AGJA | UN-NIC-ETH-MCX623106AN-CDAT-2P - 2-Port100Gb QSFP56optical interfaceMCX623106AN-CDATNetwork Adapter(CTO&BTO) |
| Optical Module | |
| 0231AC16 | QSFP-100G-SR4-MM850-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO) |
| 0231AFRV | UN-NIC-ETH531F-LP-2P - 2-Port10GEoptical interface Network Adapter(CTO&BTO) |
| 0231A8KB | UN-SFP-XG-SX-MM850-E1 - SFP+ 10GModule(850nm,300m,LC) |
| 0231AC0T | SFP-XG-LX-SM1310-CM - SFP+ 10GModule(1310nm,10km,LC)(FIO) |
| 0231AN1B | UN-NIC-ETH-N10G-LP-2P - 2-port 10G PCIe3.0 X8 SFP+ Optical Interface N10G-X2-DC Ethernet card (CTO&BTO) (for SA) |
| 0231ANJD | UN-NIC-ETH-RP1000P2SFP-LP-2P - 2-Port10GEoptical interface Network Adapter(RP1000P2SFP)(CTO&BTO) |
| 0231AC0Y | SFP-GE-SX-MM850-CM - Optical module - SFP-GE-multimode optical module (850nm, 0.55km, LC) (FIO) |
| 0231A7PX | UN-NIC-BCM957416-T-B-10Gb-2P-F - 2-Port10GEelectrical interface Network Adapter(BCM957416)(FIO) |
| 0231A8K1 | UN-NIC-GE-4P-360T-B2-1 - 4-Port Gigabitelectrical interface Network Adapter-360T-B2 |
| 0231AK5Y | UN-NIC-ETH330T-LP-4P - 4-PortGEelectrical interface Network Adapter(CTO&BTO) |
| 0231ANJJ | UN-NIC-ETH-SF400T-LP-4P-GE - 4-Port1GEelectrical interface Network Adapter(SF400T)(CTO&BTO) |
| 0231A7NH | UN-NIC-620F-B2-25Gb-2P-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2 |
| 0231A7N6 | SFP-25G-SR-MM850-1 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2 |
| 0231AFH5 | UN-NIC-ETH630F-LP-2P - 2-Port25GEoptical interface Network Adapter (ETH630F)(CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-Port25GEoptical interface Network Adapter(ETH630F)(CTO&BTO) |
| 0231AFUG | UN-NIC-ETH-MCX631102AN-ADAT - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO) |
| 0231AL2V | 0231AL2V - UNIS R4970 G7 Servers |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - Kunpeng-dedicated 2-port 25G SFP28 Optical Interface MCX512A-ACAT Ethernet card (CTO&BTO) |
| 0231ALXR | UN-NIC-ETH641F-LP-2P - 2-Port25GEoptical interface Network Adapter (ETH641F)(CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-Port25GEoptical interface Network Adapter (ETH641F)(CTO&BTO) |
| OCPNetwork Adapter | |
| 0231AEBU | UN-NIC-ETH360T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBV | UN-NIC-ETH565T-3S-2P - 2-Port10GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231ALCE | UN-NIC-ETH-BCM957416N4160C-2P - 2-Port10Gelectrical interfaceBCM957416N4160C OCP3.0Network Adapter(CTO&BTO) |
| 0231AEBY | UN-NIC-ETH561F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231ANSH | UN-NIC-ETH-SF400T-C201-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network AdapterSF400T-C201(for SA)(CTO&BTO) |
| 0231AEBW | UN-NIC-ETH640F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AMBC | UN-NIC-BCM957414N4140C-3S-2P - 2-Port 25G PCIe3.0 x8 SFP28 Optical Interface BCM957414N4140C OCP3.0 Ethernet Network Adapter Card (CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - 2-Port 25G PCIe3.0 x8 SFP28 Optical Interface BCM957414N4140C OCP3.0 Ethernet Network Adapter Card (CTO&BTO) |
| 0231AK4A | UN-SFP-25G-SR-MM850-HW-1 - UNIS R4970 G7 Servers |
| 0231A962 | SFP-GE-LX-SM1310-D - Optical Module - SFP-GE - Single-Mode Module (1310 nm, 10 km, LC) |
| Fibre Channel controller | |
| 0231AGHH | UN-FC-HBA-LPe35000-LP-32Gb-1P - 1-port 32Gb Optical Interface LPe35000 AIC FC HBA card (PCIe 4.0) (comes with one SFP+ optical module) (CTO&BTO) |
| 0231AGHJ | UN-FC-HBA-LPe35002-LP-32Gb-2P - 2-port 32Gb Optical Interface LPe35002 AIC FC HBA card (PCIe 4.0) (comes with two SFP+ optical modules) (CTO&BTO) |
| 0231AM7L | UN-FC-HBA-LPe31002-LP-16G-2P - 2-port 16Gb Optical Interface LPe31002 FC HBA card (PCIe 3.0) (with two SFP+ optical modules) (CTO&BTO) |
| Rack Rail | |
| 0231APX9 | UN-RL-G-G6 - G6 2U/1U Ball Screw Guide Rails (CTO & BTO) |
| 0231AFT2 | UN-RL-B-G5 - G5 2U/1U Standard Slides (CTO & BTO) |
| 0231AF5B | UN-RL-G-G5 - G5 2U/1U Ball-Bearings Slides (CTO & BTO) |
| Cable Management Tray | |
| 2150A0EE | CMA-2U-A - 2U Cable Management Rack |
| 0231AQCE | UN-CMA-2U-G6 - G6 2U Cable Management Rack (CTO & BTO) |
| Ear Hook | |
| 0231AKB3 | UN-EAR-QE-2U-LEFT-R4950G6 - H3C Uni Server R4950 G6 2U intelligent left ear component (CTO&BTO) |
| GPU Airflow Shroud | |
| 9821A10B | UN-FAN-COVER-3GPU-R4970G7 - R4970 G7 3GPU Dedicated Air Deflector |
| Tag | |
| 0231AGWU | UN-Label-Shock&Tilt Monitor - Anti-tilt label and 37G anti-vibration label (CTO&BTO) |
| Capacitor Box | |
| 2120A07W | BBOX-OCP-G6 - UNIS R4970 G7 Servers |
| Security Hardware | |
| 0231AKEY | UN-TCM-SPI-B - H3C server platform trusted module SPI TCM (CTO&BTO) |
| Customized module | |
| 0231A8A6 | UN-CTM-G3-F - H3C customer-specific customization module (1H) (FIO) |
| Installing Services | |
| 8814A0VB | SV-PS-UNIS-ISS - UNIS server first-time basic installation service |
| Operating System Compatibility Verification | |
| BATJOSXX | BATJOSXX - UNIS R4970 G7 Servers |
| OSCHECKX | OSCHECKX - UNIS R4970 G7 Servers |
| linux | |
| ALIN89A5 | ALIN89A5 - UNIS R4970 G7 Servers |
| O2003S4A | O2003S4A - UNIS R4970 G7 Servers |
| O2203S3A | O2203S3A - UNIS R4970 G7 Servers |
| O2403LTA | O2403LTA - UNIS R4970 G7 Servers |
| UOS2060U | UOS2060U - UNIS R4970 G7 Servers |
| UOS207RK | UOS207RK - UNIS R4970 G7 Servers |
| UOS207EK | UOS207EK - UNIS R4970 G7 Servers |
| Zhongbiao Kylin | |
| NSAQ699A | NSAQ699A - UNIS R4970 G7 Servers |
| YH10S3RA | YH10S3RA - UNIS R4970 G7 Servers |
| YH10SP3A | YH10SP3A - UNIS R4970 G7 Servers |
| Zhongke Hongqi | |
| ZKHQA88A | ZKHQA88A - UNIS R4970 G7 Servers |
| Other Operating Systems | |
| NINGV31A | NINGV31A - UNIS R4970 G7 Servers |
| OTHERSOS | OTHERSOS - UNIS R4970 G7 Servers |
| Product Identity | |
| Brand | H3C |
| Series | H3C UNIS R4970 G7 rack server (Fei teng) |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Model specification for UNIS-R4970-G7-MAL0-C?
What is the Product Code specification for UNIS-R4970-G7-MAL0-C?
What is the Product Type specification for UNIS-R4970-G7-MAL0-C?
What is the Series specification for UNIS-R4970-G7-MAL0-C?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?