| Key Specifications |
|---|
| Model | WB-R4900-G6-ULTRA-SFF-C |
| Product Code | 0235A4TA |
| Product Type | Server |
| Series | Smart Compute |
| Manufacturer | H3C |
| Description | WB R4900 G6 Ultra SFF Air-Cooled CTO Server |
| Product Specifications |
|---|
| Model | WB-R4900-G6-ULTRA-SFF-C |
| Product Code | 0235A4TA |
| Product Type | Server |
| Series | Smart Compute |
| Description | WB R4900 G6 Ultra SFF Air-Cooled CTO Server |
| Manufacturer | H3C |
| Catalog Description |
|---|
| Description | WB R4900 G6 Ultra SFF Air-Cooled CTO Server |
| Ordering Information |
|---|
| Base Configuration | |
| 0235A4TA | WB-R4900-G6-Ultra-SFF-C; WB R4900 G6 Ultra SFF Air-Cooled CTO Server |
| Processor | |
| 0231AMLX | UN-CPU-INTEL-6526Y; 6526Y (2.8 G Hz/16-core/37.5 MB/195 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMB | UN-CPU-INTEL-6530; 6530 (2.1 G Hz/32-core/160 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMR | 6534 (3.9 G Hz/8-core/22.5 MB/195 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMW | UN-CPU-INTEL-6538N; 6538N (2.1 G Hz/32-core/60 MB/205 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLF | UN-CPU-INTEL-6538Y+; 6538Y+ (2.2 G Hz/32-core/60 MB/225 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMP | UN-CPU-INTEL-6542Y; 6542Y (2.9 G Hz/24-core/60 MB/250 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLW | UN-CPU-INTEL-6544Y; 6544Y (3.6 G Hz/16-core/45 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMM3 | UN-CPU-INTEL-6548N; 6548N (2.8 G Hz/32-core/60 MB/250 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLU | UN-CPU-INTEL-6548Y+; 6548Y+ (2.5 G Hz/32-core/60 MB/250 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLQ | UN-CPU-INTEL-6554S; 6554S (2.2 G Hz/36 cores/180 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMF | UN-CPU-INTEL-6558Q; 6558Q (3.2 G Hz/32 cores/60 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLE | UN-CPU-INTEL-8558; 8558 (2.1 G Hz/48 cores/260 MB/330 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLN | UN-CPU-INTEL-8558P; 8558P (2.7 G Hz/48 cores/260 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMM2 | UN-CPU-INTEL-8558U; 8558U (2.0 G Hz/48 cores/260 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMN | UN-CPU-INTEL-8562Y+; 8562Y+ (2.8 G Hz/32-core/60 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLR | UN-CPU-INTEL-8568Y+; 8568Y+ (2.3 G Hz/48 cores/300 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMK | UN-CPU-INTEL-8570; 8570 (2.1 G Hz/56 cores/300 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMM4 | UN-CPU-INTEL-8571N; 8571N (2.4 G Hz/52 cores/300 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLP | UN-CPU-INTEL-8580; 8580 (2.0 G Hz/60 cores/300 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMJ | UN-CPU-INTEL-8581V; 8581V (2.0 G Hz/60 cores/300 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMH | UN-CPU-INTEL-8592+; 8592+(1.9 G Hz/64-core/320 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMMY | UN-CPU-INTEL-8592V; 8592V (2.0 G Hz/64-core/320 MB/330 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AMLH | UN-CPU-INTEL-8593Q; 8593Q (2.2 G Hz/64-core/320 MB/385 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0A | C4410Y (2.0 G Hz/12-core/30 MB/150 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYQ | R4900 G6 Ultra Servers; Type: Processor |
| 0231AL10 | R4900 G6 Ultra Servers; Type: Processor |
| 0231AL03 | R4900 G6 Ultra Servers; Type: Processor |
| 0231AKYA | R4900 G6 Ultra Servers; Type: Processor |
| 0231AKYS | R4900 G6 Ultra Servers; Type: Processor |
| 0231AKYD | R4900 G6 Ultra Servers; Type: Processor |
| 0231AL0M | R4900 G6 Ultra Servers; Type: Processor |
| 0231AKY7 | C8458P (2.7 G Hz/44 cores/82.5 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0G | C8462Y+ (2.8 G Hz/32-core/60 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL04 | R4900 G6 Ultra Servers; Type: Processor |
| 0231AL0L | 4410T (2.7 G Hz/10 cores/26.25 MB/150 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYL | 4416+(2.0 G Hz/20 cores/37.5 MB/165 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0X | 5415+(2.9 G Hz/8-core/22.5 MB/150 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0W | 5416S (2.0 G Hz/16-core/30 MB/150 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYH | 5418N (1.8 G Hz/24 cores/45 MB/165 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL06 | UN-CPU-INTEL-5418Y; 5418Y (2.0 G Hz/24-core/45 MB/185 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKY8 | 5420+(2.0 G Hz/28 cores/52.5 MB/205 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0H | UN-CPU-INTEL-6426Y; 6426Y (2.5 G Hz/16-core/37.5 MB/185 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYY | 6428N (1.8 G Hz/32-core/60 MB/185 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AK80 | UN-CPU-INTEL-6430; 6430 (2.1 G Hz/32 cores/60 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYM | 6434 (3.7 G Hz/8-core/22.5 MB/195 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYP | 6438M (2.2 G Hz/32 cores/60 MB/205 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0R | 6438N (2.0 G Hz/32-core/60 MB/205 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0K | 6438Y+ (2.0 G Hz/32-core/60 MB/205 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0B | 6442Y (2.6 G Hz/24-core/60 MB/225 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0T | 6444Y (3.6 G Hz/16-core/45 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYK | 6448Y (2.1 G Hz/32-core/60 MB/225 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL02 | 6454S (2.2 G Hz/32-core/60 MB/270 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYN | 6458Q (3.1 G Hz/32 cores/60 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYU | 8452Y (2.0 G Hz/36 cores/67.5 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYG | 8458P (2.7 G Hz/44 cores/82.5 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AK82 | 8460Y+ (2.0 G Hz/40 cores/105 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYE | 8462Y+ (2.8 G Hz/32-core/60 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0D | 8468 (2.1 G Hz/48 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL09 | 8468V (2.4 G Hz/48-core/97.5 MB/330 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL01 | 8470 (2.0 G Hz/52 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYX | 8470N (1.7 G Hz/52 cores/97.5 MB/300 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AL0U | 8470Q (2.1 G Hz/52 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231AKYJ | UN-CPU-INTEL-8480+; 8480+(2.0 G Hz/56 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231ALJF | 9460 (2.2 G Hz/40 cores/97.5 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231ALJD | 9462 (2.7 G Hz/32-core/75 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231ALJC | 9468 (2.1 G Hz/48 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231ALJB | 9470 (2.0 G Hz/52 cores/105 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| 0231ALJA | 9480 (1.9 G Hz/56 cores/112.5 MB/350 W) CPU Module (CTO & BTO); Type: Processor |
| Memory | |
| 0231ALVA | 16GB 1Rx8 DDR5-4800B CAS-40-39-39 RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AM23 | UN-DDR5-4800B-16G-1Rx8-R-2; 16GB 1Rx8 DDR5-4800B (CAS-40-39-39)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AK7X | 64GB 2RX4 DDR5-4800 RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AM1X | UN-DDR5-4800B-64G-2Rx4-R-2; 64GB 2Rx4 DDR5-4800B (CAS-40-39-39)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AM4C | UN-DDR5-4800B-96G-2Rx4-R-2; 96GB 2RX4 DDR5-4800B CAS-40-39-39 SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AM4E | UN-DDR5-4800B-96G-2Rx4-R; 96GB 2RX4 DDR5-4800B CAS-40-39-39 RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231ALV9 | UN-DDR5-4800B-128G-4Rx4-R; 128GB 4Rx4 DDR5-4800B 3DS CAS-46-39-39 RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMLD | UN-DDR5-5600B-32G-1Rx4-R; 32GB 1Rx4 DDR5-5600B (CAS-46-45-45)RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMM1 | UN-DDR5-5600B-32G-2Rx8-R-2; 32GB 2Rx8 DDR5-5600B (CAS-46-45-45)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMMS | UN-DDR5-5600B-32G-2Rx8-R; 32GB 2Rx8 DDR5-5600B (CAS-46-45-45)RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMMU | UN-DDR5-5600B-32G-1Rx4-R-2; 32GB 1Rx4 DDR5-5600B (CAS-46-45-45)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMLJ | UN-DDR5-5600B-64G-2Rx4-R-2; 64GB 2Rx4 DDR5-5600B (CAS-46-45-45)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMLY | UN-DDR5-5600B-64G-2Rx4-R; 64GB 2Rx4 DDR5-5600B (CAS-46-45-45)RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMME | UN-DDR5-5600B-96G-2Rx4-R-2; 96GB 2Rx4 DDR5-5600B (CAS-46-45-45)SAMSUNG&HYNIX RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231AMMT | UN-DDR5-5600B-96G-2Rx4-R; 96GB 2Rx4 DDR5-5600B (CAS-46-45-45)RDIMM Memory Module (CTO&BTO); Type: Memory |
| 0231APKA | UN-DDR5-5600B-128G-2Rx4-R; 128GB 2Rx4 DDR5-5600B (CAS-46-45-45) RDIMM Memory Module (CTO&BTO); Type: Memory |
| Configuration Options | |
| 0231AK76 | UN-DUMMY-DIMM-DDR5-M; DDR5 Fake Memory Module (CMCTO) |
| Front Hard Drive Backplate | |
| 0231AJPU | UN-PCA-BP-8SFF-2U-G6; G6 2U Front-Mounted 8-SFF Hard Drive Backplane Module (CTO & BTO); Type: Front Hard Drive Backplate |
| 0231AJQC | UN-PCA-BP-8Uni Bay-2U-G6; Type: Front Hard Drive Backplate |
| 0231AJQ4 | UN-PCA-BP-25SFF-2U-G6; G6 2U Front-Mounted 25SFF Hard Drive Backplane Module (CTO & BTO); Type: Front Hard Drive Backplate |
| Rear Hard Drive Cage | |
| 0231AK88 | UN-HDD Cage-2SFF-2U-G6; G6 2U Rear-Mounted 2SFF Hard Drive Cage Module (CTO & BTO); Type: Rear Hard Drive Cage |
| 0231AK8A | UN-HDD Cage-2Uni Bay-2U-G6; G6 2U Rear-Mounted 2SFF Uni Bay Hard Drive Cage Module (CTO & BTO); Type: Rear Hard Drive Cage |
| 0231AKEN | UN-PCA-BP-2Uni Bay-OCP-2U-G6; G6 2U Rear 2SFF Uni Bay Hard Drive Backplane and OCP 3.0 Adapter Module (CTO & BTO); Type: Rear Hard Drive Cage |
| 0231AK86 | UN-HDD Cage-4SFF-2U-G6; G6 2U Rear 4SFF Hard Drive Cage Module (CTO & BTO); Type: Rear Hard Drive Cage |
| NV Me Cable Adjustment | |
| MBNVMEMX | R4900 G6 Ultra Servers; Type: NV Me Cable Adjustment |
| MBSATAMX | R4900 G6 Ultra Servers; Type: NV Me Cable Adjustment |
| M.2 Adapter Card | |
| 0231AMP7 | Type: M.2 Adapter Card |
| 0231AF5Q | UN-RC-2M2-G5; G5 Front 2*M.2 2280/22110 Riser Module (CTO & BTO); Type: M.2 Adapter Card |
| M.2 SSD | |
| 0231AHCQ | UN-SSD-480G-SATA-S4520-M.2; 480GB SATA RI S4520 M.2 SSD Hard Drive Module (CTO&BTO); Type: M.2 SSD |
| 0231AK1R | 480GB 6G SATA RI 5400PRO M.2 SSD Hard Drive Module (CTO&BTO); Type: M.2 SSD |
| SD card | |
| 0231A6RC | UN-SD-32G-Micro-F; 32G microSD Mainstream Flash Drive Module (FIO); Type: SD card |
| 0231A7KC | R4900 G6 Ultra Servers; Type: SD card |
| SD Card Expansion Module | |
| 0231AJQE | UN-RC-DSD-UART-G6; Type: SD Card Expansion Module |
| Fan | |
| 0231AJPX | UN-FAN-8038-2U-G6; G6 2U 8038Fan Module (CTO&BTO); Type: Fan |
| 0231AJPT | UN-FAN-8056-2U-G6; G6 2U 8056Fan Module (CTO&BTO); Type: Fan |
| Power Supply | |
| 0231AGUP | UN-GW-CRPS1300D3; 1300W AC & 240V High-Voltage DC Power Supply Module (GW-R1 - Platinum - High Efficiency at Light Loads) (CTO & BTO); Type: Power Supply |
| 0231AJYB | UN-PS-2132-5L5; 1300W AC & 240V High-Voltage DC Power Supply Module (LT-R1 - Platinum - High Efficiency at Light Loads) (CTO & BTO); Type: Power Supply |
| 0231ACT9 | DPS-1300AB-6 R-M; Type: Power Supply |
| 0231ACTG | FSP1600-20FH-M; 1600W 336V High-Voltage DC Power Supply Module (Dedicated Power Supply Cable) (FP-R1-Platinum) (CMCTO); Type: Power Supply |
| 0231AHRV | UN-DD-2162-3L5; Type: Power Supply |
| 0231AMKU | UN-GW-CRPS1600C2; 1600W AC & 240V High-Voltage DC Power Supply Module (GW-R1-Titanium) (CTO & BTO); Type: Power Supply |
| 0231AMPJ | UN-CRPS-1600W-AC-12V-94%-M; 1600 W AC & 240 V High-Voltage DC power (Platinum) (CMCTO); Type: Power Supply |
| 0231AGUN | UN-GW-CRPS1600D2; 1600W AC & 240V High-Voltage DC Power Supply Module (GW-R1 - Platinum) (CTO & BTO); Type: Power Supply |
| 0231ACTA | DPS-1600AB-13 R-M; Type: Power Supply |
| 0231AMQ7 | UN-CRPS-2000W-AC-12V-94%-M; 2000WAC & 240V High-Voltage DC power (Platinum—High Efficiency at Light Loads) (CMCTO); Type: Power Supply |
| 0231AFSS | UN-GW-CRPS2000D; 2000WAC & 240V High-Voltage DC Power Supply Module (GW-R2 - Platinum - High Efficiency at Light Loads) (CTO & BTO); Type: Power Supply |
| 0231AHRU | UN-PS-2202-11L; 2000WAC & 240V High-Voltage DC Power Supply Module (LT-R1 - Platinum - High Efficiency at Light Loads) (CTO & BTO); Type: Power Supply |
| 0231AFQB | UN-DPS-2400EB B; 2400W AC & 240V High Voltage DC Power Supply Module (DT-R1-Platinum) (CTO & BTO); Type: Power Supply |
| Configuration Options | |
| 0404A0X6 | CAB-DC PWR-3.0m-3V3; (-48V) DC power cable - 3.0 m - (P3W-3V3 female connector) - (UL2464 12 AWG/3C black) - (3*T2510 blue) |
| 0404A0K4 | CAB-PDU-2.0m-C14-C13-MUL-50598; PDU Power Supply Cable—2.0 m—1.0 mm²—Black—(C14 Connector (3P) Straight Male, 250 V, 10 A)—(227 IEC 53 (RVV) & H05VV-F & SJT)—(C13)—Chinese, U. S., European, and Korean Standards |
| 0404A19Y | CAB-AC Pwr-3m-C19-CHE; R4900 G6 Ultra Servers |
| 0404A06Q | CAB-AC Pwr CHI-1.8m; Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard |
| 04040890 | CAB-AC Pwr EN&SI-3m; AC power Cord for Wall Outlet—3.0 m—1.0 mm²—Black—(BS1363A Plug (3P), Angled Male, 250 V, 13 A)—(H05VV-F)—(C13 Connector (3P), Straight Female, 250 V, 10 A)—British Standard |
| 0404A0MW | CAB-AC-16A-PDU-3m-Eu; PDU Power Supply Cable—3.0 m—1.5 mm²—Black—(C20 Connector (3P), Straight Male, 250 V, 16 A)—(H05VV-F)—(C19 Connector (3P), Straight Female, 250 V, 16 A)—European Standard |
| Slot 1 & 2 Adapter Card | |
| 0231AJQ9 | UN-RC-3FHHL-2U-G6; Type: Slot 1 & 2 Adapter Card |
| 0231AJQF | UN-RC-3FHFL-2U-G6; Type: Slot 1 & 2 Adapter Card |
| 0231AK6U | UN-RC-2FHHL-2U-G6; Type: Slot 1 & 2 Adapter Card |
| 0231AK8E | UN-RC-1FHHL-2U-G6; Type: Slot 1 & 2 Adapter Card |
| 0231AN9X | UN-RC-3FHFL-2U-G6-1; Type: Slot 1 & 2 Adapter Card |
| Slot 3 Adapter Card | |
| 0231AJPW | UN-RC-2HHHL-R3-2U-G6; Type: Slot 3 Adapter Card |
| 0231AJQ7 | UN-RC-2FHFL-R3-2U-G6; Type: Slot 3 Adapter Card |
| 0231AJQA | UN-RC-1FHFL-R3-2U-G6; Type: Slot 3 Adapter Card |
| 0231AKED | UN-RC-2HHHL-R3-2U-G6-2; Type: Slot 3 Adapter Card |
| Slot4 Adapter Card | |
| 0231AJPS | UN-RC-2HHHL-R4-2U-G6; Type: Slot4 Adapter Card |
| 4GPU Module | |
| 0231AK8B | UN-PCA-R4900-4GPU-G6; G6 2U 4GPU Module (CTO&BTO); Type: 4GPU Module |
| M.2 PC Ie Card | |
| 0231AGT9 | UN-RAID-MARVELL-SANTACRUZ-LP-2i; Type: M.2 PC Ie Card |
| 0231AKB0 | UN-RAID-MARVELL-M.2; Type: M.2 PC Ie Card |
| Standard Control Card (PC Ie Standard Card) | |
| 0231AG62 | UN-RAID-LSI-9560-LP-8i-4GB; Type: Standard Control Card (PC Ie Standard Card) |
| 0231AJ69 | UN-HBA-LSI-9540-LP-8i; Type: Standard Control Card (PC Ie Standard Card) |
| 0231AJ6E | UN-HBA-LSI-9500-LP-8i; Type: Standard Control Card (PC Ie Standard Card) |
| 0231AEVL | UN-RAID-LSI-9560-LP-16i-8GB-M; Type: Standard Control Card (PC Ie Standard Card) |
| 0231AJ6M | UN-HBA-LSI-9500-LP-16i; Type: Standard Control Card (PC Ie Standard Card) |
| 0231A8P1 | UN-RAID-P460-B4-F; Type: Standard Control Card (PC Ie Standard Card) |
| 0231AAUF | P460-B2 12G SAS RAID Card Module (Supports 8 x SAS Ports, with 2GB Cache, without Supercapacitor) (CMCTO); Type: Standard Control Card (PC Ie Standard Card) |
| 0231A8ND | UN-HBA-H460-B1-F; Type: Standard Control Card (PC Ie Standard Card) |
| Battery | |
| 0231AEYR | UN-BAT-LSI-G3-A; LSI G3 Supercapacitor Module (CTO & BTO); Type: Battery |
| 0231AFA4 | UN-BAT-PMC-G3-2U; PMC G3 Supercapacitor Module (for use in 2U standard chassis) (CTO & BTO); Type: Battery |
| VROC Module (Supports NV Me Hard DriveRAID) | |
| 0231A6R6 | UN-NV Me-VROC-Key-S-F; Type: VROC Module (Supports NV Me Hard DriveRAID) |
| 0231A6R8 | UN-NV Me-VROC-Key-P-F; Type: VROC Module (Supports NV Me Hard DriveRAID) |
| Graphics Card | |
| 0231AJFS | UN-GPU-A16-64G-DW; NVIDIA A16 64G GPU Module (CTO&BTO); Type: Graphics Card |
| 0231AL4D | R4900 G6 Ultra Servers; Type: Graphics Card |
| 0231ANF4 | UN-GPU-48GB-DW; NVIDIA 48G PC Ie4.0 X16 FHFL GPU Module (CTO&BTO); Type: Graphics Card |
| 0231ALL7 | R4900 G6 Ultra Servers; Type: Graphics Card |
| 0231ALLA | UN-GPU-L40-48GB; NVIDIA L40 48G GPU Module (CTO&BTO); Type: Graphics Card |
| 0231AG9X | UN-GPU-A10-24G; NVIDIA Tesla A10 24G GPU Module (Non-CEC)(CTO&BTO); Type: Graphics Card |
| 0231ANMC | Nvidia L2 24G PC Ie4.0 X16 HHHL GPU Module (CTO&BTO); Type: Graphics Card |
| 0231AJWA | UN-GPU-A2-16GB-NoCEC; Nvidia Tesla A2 16GB Non-CEC GPU Module (CTO&BTO); Type: Graphics Card |
| 0231AK45 | R4900 G6 Ultra Servers; Type: Graphics Card |
| 0231AJWD | R4900 G6 Ultra Servers; Type: Graphics Card |
| 0231ABT8 | UN-GPU-T4-F; T4 Display Acceleration Card (FIO); Type: Graphics Card |
| 0231APKW | UN-GPU-LEADTEK-RTX4090 D-24GB-DW; R4900 G6 Ultra Servers; Type: Graphics Card |
| Network Adapter | |
| 0231AEC7 | 1-Port 100Gb QSFP28 Optical Interface MCX515A-CCAT Ethernet Card (CMCTO); Type: Network Adapter |
| Optical Module | |
| 0231AC16 | QSFP-100G-SR4-MM850-CM; 100G QSFP28 Optical Module (850nm, 100m OM4, SR4, MPO)(FIO); Type: Optical Module |
| Network Adapter | |
| 0231AFUR | R4900 G6 Ultra Servers; Type: Network Adapter |
| Optical Module | |
| 0231AFUP | UN-CAB-IB-DAC-MCP7H50-V002R26-2m; Mellanox 2m HDR100 100G DAC breakout cable (CTO&BTO); Type: Optical Module |
| Network Adapter | |
| 0231ADWS | 2-Port100GE Optical Interface Network Adapter (QSFP28)(CTO&BTO); Type: Network Adapter |
| 0231AEC8 | UN-NIC-ETH-MCX516A-CCAT-2P-M; 2-Port 100Gb QSFP28 Optical Interface MCX516A-CCATE Ethernet Card (CMCTO); Type: Network Adapter |
| 0231AFUS | UN-IB-MCX653106A-ECAT-100Gb-2P; Type: Network Adapter |
| 0231AGJA | UN-NIC-ETH-MCX623106AN-CDAT-2P; 2-Port100Gb QSFP56Optical InterfaceMCX623106AN-CDAT Network Adapter (CTO&BTO); Type: Network Adapter |
| Optical Module | |
| 0231AC0U | QSFP-40G-SR4-MM850-CM; Type: Optical Module |
| Network Adapter | |
| 0231AH2Y | UN-NIC-BCM957508-P2100G-2P; 2-Port 100Gb QSFP56 Optical Interface BCM957508-P2 100G Ethernet Card (CTO & BTO); Type: Network Adapter |
| 0231A7PW | UN-NIC-BCM957412-F-B-10Gb-2P-F; 2-Port10GE Optical Interface Network Adapter (BCM957412)(FIO); Type: Network Adapter |
| Optical Module | |
| 0231A8KB | UN-SFP-XG-SX-MM850-E1; SFP+ 10G Module (850nm, 300m, LC); Type: Optical Module |
| 0231AC0T | SFP-XG-LX-SM1310-CM; SFP+ 10G Module (1310nm, 10km, LC)(FIO); Type: Optical Module |
| Network Adapter | |
| 0231A8K2 | UN-CNA-10GE-2P-560F-B2-1; 2-Port10G Optical Interface Network Adapter (SFP+)-560F-B2; Type: Network Adapter |
| Optical Module | |
| 0231AC0Y | SFP-GE-SX-MM850-CM; Optical Module-SFP-GE-multimode Optical Module (850nm, 0.55km, LC)(FIO); Type: Optical Module |
| Network Adapter | |
| 0231A9AU | UN-NIC-X710DA2-F-B-10Gb-2P-F2; 2-Port10GE Optical Interface Network Adapter (SFP+)(FIO); Type: Network Adapter |
| 0231AFRV | UN-NIC-ETH531F-LP-2P; 2-Port10GE Optical Interface Network Adapter (CTO&BTO); Type: Network Adapter |
| 0231A7WC | UN-NIC-X710DA4-F-B-10Gb-4P-F; 4-Port10GE Optical Interface Network Adapter (SFP+)(FIO); Type: Network Adapter |
| 0231A7NA | UN-CNA-560T-B2-10Gb-2P-1; 2-Port10Gbelectrical interface Network Adapter-560T-B2; Type: Network Adapter |
| 0231A8K1 | UN-NIC-GE-4P-360T-B2-1; 4-Port Gigabitelectrical interface Network Adapter-360T-B2; Type: Network Adapter |
| 0231AJG0 | UN-NIC-BCM95719A1904AC-LP-4P; R4900 G6 Ultra Servers; Type: Network Adapter |
| 0231AFN6 | UN-NIC-ETH-MCX623105AN-VDAT-1P; 1-Port 200Gb QSFP56 Optical Interface MCX623105AN-VDAT Ethernet Card (CTO & BTO); Type: Network Adapter |
| 0231AFN8 | UN-IB-MCX653105A-HDAT-200Gb-1P; Type: Network Adapter |
| 0231AM5N | UN-IB-MCX75310AAS-HEAT-200Gb-1P; Type: Network Adapter |
| Optical Module | |
| 0231ANGH | UN-OSFP-RHS-400G-VR4-MM850; 400G OSFP RHS Optical Module (850nm, 50m OM4, VR4, MPO12/APC); Type: Optical Module |
| Network Adapter | |
| 0231AM5P | UN-IB-MCX755106AS-HEAT-200Gb-2P; Type: Network Adapter |
| 0231A7G6 | UN-NIC-MCX4121A-F-B-25Gb-2P-F; 2-Port25Gb Optical Interface Network Adapter (SFP28)(FIO); Type: Network Adapter |
| Optical Module | |
| 0231A7N6 | SFP-25G-SR-MM850-1; 25G SFP28 Optical Module (850nm, 100m, SR, MM, LC); Type: Optical Module |
| Network Adapter | |
| 0231A7NH | UN-NIC-620F-B2-25Gb-2P-1; 2-Port25Gb Optical Interface Network Adapter (SFP+)-620F-B2; Type: Network Adapter |
| 0231A7Q2 | UN-NIC-BCM957414-F-B-25Gb-2P-F; 2-Port25GE Optical Interface Network Adapter (BCM957414)(FIO); Type: Network Adapter |
| 0231AB5W | UN-NIC-MCX512A-ACAT-F-2*25Gb-F; 2-Port25Gb Optical Interface Network Adapter (SFP28)(MCX512A-ACAT)(FIO); Type: Network Adapter |
| 0231AFGV | R4900 G6 Ultra Servers; Type: Network Adapter |
| 0231AFH5 | UN-NIC-ETH630F-LP-2P; 2-Port25GE Optical Interface Network Adapter (ETH630F)(CTO&BTO); Type: Network Adapter |
| 0231AFUG | UN-NIC-ETH-MCX631102AN-ADAT; Type: Network Adapter |
| 0231AG88 | UN-NIC-ETH-E810XXVDA2G1P5-2P; Type: Network Adapter |
| 0231ALXR | UN-NIC-ETH641F-LP-2P; 2-Port25GE Optical Interface Network Adapter (ETH641F)(CTO&BTO); Type: Network Adapter |
| 0231ALPQ | UN-IB-MCX75310AAS-NEAT-400Gb-1P; Type: Network Adapter |
| OCP Network Adapter | |
| 0231AGFL | UN-NIC-ETH-MCX623436AN-CDAB-2P; 2-Port100Gb Optical InterfaceMCX623436AN-CDAB OCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AKMH | UN-NIC-BCM957508-N2100G-3S-2P; 2-Port100Gb QSFP56Optical InterfaceBCM957508-N2100G OCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AEBU | UN-NIC-ETH360T-3S-4P; 4-Port1G Eelectrical interfaceOCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AEBV | UN-NIC-ETH565T-3S-2P; 2-Port10G Eelectrical interfaceOCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AEBY | UN-NIC-ETH561F-3S-2P; 2-Port10GE Optical InterfaceOCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AN1D | UN-NIC-ETH531F-3S-2P; 2-Port10GE Optical InterfaceOCP3.0Network Adapter (ETH531F)(CTO&BTO); Type: OCP Network Adapter |
| 0231AN1E | UN-NIC-ETH330T-3S-4P; 4-Port1G Eelectrical interfaceOCP3.0Network Adapter (ETH330T)(CTO&BTO); Type: OCP Network Adapter |
| 0231ABWF | UN-NIC-MCX4621A-ACAB-2*25G-M; 2-Port25G OCP3.0Network Adapter (MCX4621A-ACAB)(FIO); Type: OCP Network Adapter |
| 0231AEBW | UN-NIC-ETH640F-3S-2P; 2-Port25GE Optical InterfaceOCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AFH3 | UN-NIC-ETH660F-3S-2P; 2-Port25GE Optical InterfaceOCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AG96 | UN-NIC-ETH-MCX631432AN-ADAB-2P; 2-Port25Gb SFP28 Optical InterfaceMCX631432AN OCP3.0Network Adapter (CTO&BTO); Type: OCP Network Adapter |
| 0231AGL9 | R4900 G6 Ultra Servers; Type: OCP Network Adapter |
| Fiber Controller | |
| 0231A7LG | UN-FC-HBA-L Pe32000-32Gb-1P; 1-Port 32Gb Fibre Channel HBA Card (with one SFP+ optical module); Type: Fiber Controller |
| 0231A7LN | UN-FC-HBA-L Pe32002-32Gb-2P; 2-Port 32Gb Fibre Channel HBA Card (with two SFP+ optical modules); Type: Fiber Controller |
| 0231A7NB | UN-HBA-16Gb-L Pe31000-1P-1; 1-Port 16 Gb Fibre Channel HBA Card (with one SFP+ module); Type: Fiber Controller |
| 0231A7NF | UN-HBA-16Gb-L Pe31002-2P-1; 2-Port 16Gb Fibre Channel HBA Card (with two SFP+ modules); Type: Fiber Controller |
| 0231A7PV | UN-FC-HBA-QLE2742-32Gb-2P-F; 32 Gb 2-Port PC Ie Fibre Channel HBA Card (with Two SFP+ Optical Modules) (FIO); Type: Fiber Controller |
| 0231A7Q1 | UN-FC-HBA-QLE2740-32Gb-1P-F; 32Gb 1-Port PC Ie Fibre Channel HBA Card (with one SFP+ optical module) (FIO); Type: Fiber Controller |
| 0231A8JQ | UN-FC-HBA-QLE2690-16Gb-1P-1; 1-Port 16 Gb Fibre Channel HBA Card (with one SFP+ module); Type: Fiber Controller |
| 0231A8JV | UN-FC-HBA-QLE2692-16Gb-2P-1; 2-Port 16Gb Fibre Channel HBA Card (with two SFP+ modules); Type: Fiber Controller |
| 0231AGHH | UN-FC-HBA-L Pe35000-LP-32Gb-1P; Type: Fiber Controller |
| 0231AGHJ | UN-FC-HBA-L Pe35002-LP-32Gb-2P; Type: Fiber Controller |
| 0231AM7K | UN-FC-HBA-L Pe31000-LP-16G-1P; Type: Fiber Controller |
| 0231AM7L | UN-FC-HBA-L Pe31002-LP-16G-2P; Type: Fiber Controller |
| 0231ANQ1 | UN-FC-HBA-L Pe36002-LP-64G-2P; 2-Port 64Gb PC Ie 4.0 x8 SFP+ Optical Interface L Pe36002 LP FC HBA Card (with two SFP+ optical modules) (CTO & BTO); Type: Fiber Controller |
| 0231ANQ2 | UN-FC-HBA-L Pe36000-LP-64G-1P; 1-Port 64Gb PC Ie 4.0 x8 SFP+ Optical Interface L Pe36000 LP FC HBA Card (with one SFP+ Optical Module) (CTO & BTO); Type: Fiber Controller |
| 0231APSM | UN-FC-HBA-QLE2870-LP-64G-1P; Type: Fiber Controller |
| 0231APSU | UN-FC-HBA-QLE2872-LP-64G-2P; Type: Fiber Controller |
| SSD Acceleration Card | |
| 0231AHWE | UN-SSD-3.2T-NV Me-PB6536-AIC; 3.2T NV Me SSD PB6 6536 SSD PC Ie Acceleration Card Module (CTO & BTO); Type: SSD Acceleration Card |
| 0231AN26 | UN-SSD-3.2T-NV Me-PB6537-AIC; 3.2TB NV Me SSD MU PB6 6537 SSD PC Ie Acceleration Card Module (CTO & BTO); Type: SSD Acceleration Card |
| 0231AJ64 | UN-SSD-6.4T-NV Me-PB6536-AIC; 6.4T NV Me SSD PB6 6536 SSD PC Ie Acceleration Card Module (CTO & BTO); Type: SSD Acceleration Card |
| 0231AN23 | UN-SSD-6.4T-NV Me-PB6537-AIC; 6.4TB NV Me SSD MU PB6 6537 SSD PC Ie Acceleration Card Module (CTO & BTO); Type: SSD Acceleration Card |
| i Fist Module | |
| 0231AJQ5 | UN-IFIST-EX-G6; G6 iFIST Module (CTO&BTO); Type: I Fist Module |
| Diagnostic Module | |
| 0231AE9Y | UN-SID-LCD-SFF-M; SFF LCD Panel Module (CMCTO); Type: Diagnostic Module |
| Security Hardware | |
| 0231AKEY | UN-TCM-SPI-B; H3C Server Series Trusted Platform Module SPI TCM (CTO & BTO); Type: Security Hardware |
| 0231AKEX | UN-TPM-SPI-B; H3C Server Series Trusted Platform Module SPI TPM (CTO & BTO); Type: Security Hardware |
| Optical Drive | |
| 0231A6R9 | Mobile USB 2.0 Interface Read/Write Optical Drive Module (FIO); Type: Optical Drive |
| Rack Rail | |
| 0231APX9 | UN-RL-G-G6; G6 2U/1U Ball Screw Guide Rails (CTO & BTO); Type: Rack Rail |
| 0231AFT2 | UN-RL-B-G5; G5 2U/1U Standard Slides (CTO & BTO); Type: Rack Rail |
| 0231AF5B | UN-RL-G-G5; G5 2U/1U Ball-Bearings Slides (CTO & BTO); Type: Rack Rail |
| Cable Management Tray | |
| 2150A0EF | CMA-1U-A; 1U Cable Management Rack; Type: Cable Management Tray |
| 0231AQCE | UN-CMA-2U-G6; G6 2U Cable Management Rack (CTO & BTO); Type: Cable Management Tray |
| Security Panel | |
| 0231AGF6 | WB-SEC-Panel-2U-G5; WB 2U Smart Security Panel Module (CTO & BTO); Type: Security Panel |
| 0231ALF6 | WB-Bezel-2U-G5-L; WB 2U-compatible security panel (CTO & BTO); Type: Security Panel |
| Ear Hook | |
| 0231AJQG | UN-EAR-QE-2U-LED-G6; G6 2U Smart Left-Mount Bracket (CTO & BTO); Type: Ear Hook |
| GPU Airflow Shroud | |
| 0231AJQ0 | UN-FAN-COVER-3GPU-G6; G6 3GPU Dedicated Airflow Shroud Module (CTO & BTO); Type: GPU Airflow Shroud |
| Tag | |
| 0231AGWU | UN-Label-Shock&Tilt Monitor; Anti-tilt labels and 37G shock-resistant labels (CTO & BTO); Type: Tag |
| Is customization Required? | |
| CUSTNEED | R4900 G6 Ultra Servers; Type: Is customization Required? |
| Custom Module | |
| 0231A8A6 | UN-CTM-G3-F; H3C Customized Module (1H) (FIO); Type: Custom Module |
| Installing Services | |
| 8814A0VA | SV-PS-OEM-SERV-ISS; Initial Basic Installation of OEM Server Services; Type: Installing Services |
| Operating System Compatibility Verification | |
| BATJOSXX | R4900 G6 Ultra Servers; Type: Operating System Compatibility Verification |
| OSCHECKX | R4900 G6 Ultra Servers; Type: Operating System Compatibility Verification |
| Windows | |
| 2019R0HY | R4900 G6 Ultra Servers; Type: Windows |
| 2019R0XX | R4900 G6 Ultra Servers; Type: Windows |
| 2022R0XX | R4900 G6 Ultra Servers; Type: Windows |
| linux | |
| H3LX202S | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN86 | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN88 | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN89 | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN90 | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN92 | R4900 G6 Ultra Servers; Type: Linux |
| ORACLN93 | R4900 G6 Ultra Servers; Type: Linux |
| 86ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 87ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 88ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 89ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 90ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 91ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 92ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| 94ENTHAT | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL86 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL87 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL88 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL89 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL90 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL91 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL92 | R4900 G6 Ultra Servers; Type: Linux |
| ROCKYL93 | R4900 G6 Ultra Servers; Type: Linux |
| SLE15SP4 | R4900 G6 Ultra Servers; Type: Linux |
| UB2045HK | R4900 G6 Ultra Servers; Type: Linux |
| UBSE224X | R4900 G6 Ultra Servers; Type: Linux |
| UBSE2245 | R4900 G6 Ultra Servers; Type: Linux |
| Hyper Visors | |
| CASE0783 | R4900 G6 Ultra Servers; Type: Hyper Visors |
| CTXS82XX | R4900 G6 Ultra Servers; Type: Hyper Visors |
| VMES70U3 | R4900 G6 Ultra Servers; Type: Hyper Visors |
| VMES8064 | R4900 G6 Ultra Servers; Type: Hyper Visors |
| VMES80U1 | R4900 G6 Ultra Servers; Type: Hyper Visors |
| VMES80U2 | R4900 G6 Ultra Servers; Type: Hyper Visors |
| Other Operating Systems | |
| NINGV312 | R4900 G6 Ultra Servers; Type: Other Operating Systems |
| OTHERSOS | R4900 G6 Ultra Servers; Type: Other Operating Systems |
| Product Identity |
|---|
| Brand | H3C |
| Series | Smart Compute |