H3C WB-R4950-G5-SFF-C WB R4950 G5 SFF CTOServers

H3C WB-R4950-G5-SFF-C
H3C WB-R4950-G5-SFF-C WB R4950 G5 SFF CTOServers. Interface: Front: 1x VGA, USB2.0 on the left latch, USB3.0 on the right latch, 1x Type C interface; built-in: 2x USB3.0; Rear: 1x VGA, 1x serial port, 2x USB3.0, 1x HDM dedicated network port. Processor: Supports 2 AMD EPYC Rome/Milan/Milan-X processors; up to 64 cores per processor; maximum power 280W. Memory: Supports up to 32 DDR4 memory slots, with speeds up to 32
Key Specifications
Need configuration help?
Our CCIE certified engineers can help you verify compatibility.
Fast Dispatch
Global logistics network aiming for same-day handover.
Guaranteed Quality
Every unit undergoes rigorous 38-point inspection test.
Global Reach
Trusted by enterprise clients across 6 continents.
Expert Support
Certified network engineers ready to assist with configuration.
Overview
Specifications
| Catalog Description | |
|---|---|
| Description | WB R4950 G5 SFF CTOServers |
| Key Specifications | |
| Interface | Front: 1x VGA, USB2.0 on the left latch, USB3.0 on the right latch, 1x Type C interface; built-in: 2x USB3.0; Rear: 1x VGA, 1x serial port, 2x USB3.0, 1x HDM dedicated network port |
| Dimensions/Chassis Size | 2U chassis: chassis dimensions (excluding the safety panel) (L×W×H): 748.0mm×445.4mm×87.5mm; chassis dimensions (including the safety panel) (L×W×H): 775.5mm×445.4mm×87.5mm |
| Power Supply and Cooling | Optional Platinum-class redundant power supplies 550W/800W/850W/1200W 1600W/2000W/2400W; supports hot-plug redundant fans |
| operating temperature | 5℃~40℃ (working temperature support depends on different configurations; for details, refer to the detailed product technical documents) |
| Processor | Supports 2 AMD EPYC Rome/Milan/Milan-X processors; up to 64 cores per processor; maximum power 280W |
| Memory | Supports up to 32 DDR4 memory slots, with speeds up to 3200MT/s, supports RDIMM or LRDIMM, and up to 4TB per single processor |
| Product Specifications | |
| Processor | Supports 2 AMD EPYC Rome/Milan/Milan-X processors; up to 64 cores per processor; maximum power 280W |
| Memory | Supports up to 32 DDR4 memory slots, with speeds up to 3200MT/s, supports RDIMM or LRDIMM, and up to 4TB per single processor |
| Storage Controller | Optional RAID controller based on an array-card dedicated slot, supporting RAID 0/1/5/6/10/50/60 |
| FBWC | Up to 4GB |
| Storage | Supports up to 31 2.5-inch SATA/SAS hard drives (25 front + 6 rear expansion); supports up to 16 3.5-inch SATA/SAS hard drives (12 front + 4 rear expansion); supports up to 24 NVMe SSDs*; supports up to 2x 2280/22110 M.2 drives |
| Network | Supports up to 2 OCP 3.0 network cards*; supports network adapters based on standard PCIe slots; supports Infini Band cards |
| extended slot | Supports up to 10 PCIe 4.0/3.0 available slots* |
| Interface | Front: 1x VGA, USB2.0 on the left latch, USB3.0 on the right latch, 1x Type C interface; built-in: 2x USB3.0; Rear: 1x VGA, 1x serial port, 2x USB3.0, 1x HDM dedicated network port |
| GPU Support | Up to 4 dual-width or 6 single-width GPU cards |
| Optical Drive | Supports external optical drive |
| Management | HDM agentless management tool (with a dedicated management port) and H3C FIST management software; supports an LED fault diagnosis panel |
| Security | Supports chassis intrusion detection; TCM/TPM security module |
| Power Supply and Cooling | Optional Platinum-class redundant power supplies 550W/800W/850W/1200W 1600W/2000W/2400W; supports hot-plug redundant fans |
| Authentication | Supports CCC, CECP, SEPAetc.Authentication |
| operating temperature | 5℃~40℃ (working temperature support depends on different configurations; for details, refer to the detailed product technical documents) |
| Dimensions/Chassis Size | 2U chassis: chassis dimensions (excluding the safety panel) (L×W×H): 748.0mm×445.4mm×87.5mm; chassis dimensions (including the safety panel) (L×W×H): 775.5mm×445.4mm×87.5mm |
| Warranty | 3-year 5x9 support, next business day response (NBD) |
| Ordering Information | |
| CPU with a heat sink | |
| 0231AG4W | 0231AG4W - H3C Uni Server R4950 G5 7713 (2.0GHz/64 cores/256MB/225W) Milan CPU module (CTO&BTO) |
| 0231AGC9 | 0231AGC9 - H3C Uni Server R4950 G5 7313 (3.0GHz/16 cores/128MB/155W) Milan CPU module (CTO&BTO) |
| 0231AGCA | 0231AGCA - H3C Uni Server R4950 G5 7643 (2.3GHz/48 cores/256MB/225W) Milan CPU module (CTO&BTO) |
| 0231AGCD | UN-CPU-AMD-7513-2Ub-G5 - H3C Uni Server R4950 G5 7513 (2.6GHz/32 cores/128MB/200W) Milan CPU module (CTO&BTO) |
| 0231AGCF | 0231AGCF - H3C Uni Server R4950 G5 7763 (2.45GHz/64 cores/256MB/280W) Milan CPU module (CTO&BTO) |
| 0231AGCH | UN-CPU-AMD-7543-2Ub-G5 - H3C Uni Server R4950 G5 7543 (2.8GHz/32 cores/256MB/225W) Milan CPU module (CTO&BTO) |
| 0231AGFS | 0231AGFS - R4950 G5 Server |
| 0231AH54 | 0231AH54 - H3C Uni Server R4950 G5 74F3 (3.2GHz/24 cores/256MB/240W) Milan CPU module (CTO&BTO) |
| 0231AH55 | 0231AH55 - H3C Uni Server R4950 G5 73F3 (3.5GHz/16 cores/256MB/240W) Milan CPU module (CTO&BTO) |
| 0231AH5F | 0231AH5F - R4950 G5 Server |
| 0231AHQD | 0231AHQD - H3C Uni Server R4950 G5 75F3 (2.95GHz/32 cores/256MB/280W) Milan CPU module (CTO&BTO) |
| 0231AHQE | 0231AHQE - H3C Uni Server R4950 G5 7453 (2.75GHz/28 cores/64MB/225W) Milan CPU module (CTO&BTO) |
| 0231AJ30 | 0231AJ30 - H3C Uni Server R4950 G5 7443 (2.85GHz/24 cores/128MB/200W) Milan CPU module (CTO&BTO) |
| 0231AJ4R | 0231AJ4R - H3C Uni Server R4950 G5 7A23 (2.8GHz/48 cores/192MB/280W) Milan CPU module (CTO&BTO) |
| 0231AJ4S | 0231AJ4S - H3C Uni Server R4950 G5 7663 (2.0GHz/56 cores/256MB/240W) Milan CPU module (CTO&BTO) |
| 0231AJ4W | 0231AJ4W - H3C Uni Server R4950 G5 72F3 (3.7GHz/8 cores/256MB/180W) Milan CPU module (CTO&BTO) |
| 0231AJ79 | 0231AJ79 - H3C Uni Server R4950 G5 7413 (2.65GHz/24 cores/128MB/180W) Milan CPU module (CTO&BTO) |
| 0231AJ7P | 0231AJ7P - H3C Uni Server R4950 G5 7773X (2.20GHz/64 cores/768MB/280W) MilanX CPU module (CTO&BTO) |
| 0231AJ7Q | 0231AJ7Q - H3C Uni Server R4950 G5 7573X (2.80GHz/32 cores/768MB/280W) MilanX CPU module (CTO&BTO) |
| 0231AKQB | 0231AKQB - H3C Uni Server R4950 G5 7343 (3.2GHz/16 cores/128MB/190W) Milan CPU module (CTO&BTO) |
| 0231AF7M | 0231AF7M - R4950 G5 Server |
| 0231AF7Q | 0231AF7Q - R4950 G5 Server |
| 0231AF7R | 0231AF7R - R4950 G5 Server |
| 0231AF7S | 0231AF7S - R4950 G5 Server |
| 0231AF7T | 0231AF7T - R4950 G5 Server |
| 0231AF7U | 0231AF7U - R4950 G5 Server |
| 0231AF7X | 0231AF7X - R4950 G5 Server |
| 0231AF7Y | 0231AF7Y - H3C Uni Server R4950 G5 7642 (2.3GHz/48 cores/256MB/225W) CPU module (CTO&BTO) |
| 0231AF80 | 0231AF80 - R4950 G5 Server |
| 0231AF81 | 0231AF81 - R4950 G5 Server |
| 0231AF82 | 0231AF82 - R4950 G5 Server |
| 0231AF84 | 0231AF84 - R4950 G5 Server |
| 0231AF85 | 0231AF85 - R4950 G5 Server |
| 0231AF86 | 0231AF86 - R4950 G5 Server |
| 0231AF87 | 0231AF87 - R4950 G5 Server |
| 0231AFDH | 0231AFDH - R4950 G5 Server |
| 0231AFEF | 0231AFEF - R4950 G5 Server |
| 0231AFEQ | 0231AFEQ - R4950 G5 Server |
| 0231AFET | 0231AFET - R4950 G5 Server |
| 0231AG4U | 0231AG4U - R4950 G5 Server |
| 0231AG4V | 0231AG4V - R4950 G5 Server |
| 0231AJP6 | 0231AJP6 - R4950 G5 Server |
| CPU without heatsink | |
| 0231ALP0 | 0231ALP0 - AMD Milan 72F3 (3.7GHz/8 cores/256MB/180W) CPU module (CTO&BTO) |
| 0231ALP2 | 0231ALP2 - AMD Milan 7313 (3.0GHz/16 cores/128MB/155W) CPU module (CTO&BTO) |
| 0231ALNT | 0231ALNT - AMD Milan 7343 (3.2GHz/16 cores/128MB/190W) CPU module (CTO&BTO) |
| 0231ALP9 | 0231ALP9 - AMD Milan 73F3 (3.5GHz/16 cores/256MB/240W) CPU module (CTO&BTO) |
| 0231ALNE | 0231ALNE - AMD Milan 7413 (2.65GHz/24 cores/128MB/180W) CPU module (CTO&BTO) |
| 0231ALNV | 0231ALNV - AMD Milan 7443 (2.85GHz/24 cores/128MB/200W) CPU module (CTO&BTO) |
| 0231ALN3 | 0231ALN3 - R4950 G5 Server |
| 0231ALPB | 0231ALPB - AMD Milan 7453 (2.75GHz/28 cores/64MB/225W) CPU module (CTO&BTO) |
| 0231ALNF | 0231ALNF - AMD Milan 74F3 (3.2GHz/24 cores/256MB/240W) CPU module (CTO&BTO) |
| 0231ALP3 | UN-CPU-AMD-7513 - AMD Milan 7513 (2.6GHz/32 cores/128MB/200W) CPU module (CTO&BTO) |
| 0231ALN9 | UN-CPU-AMD-7543 - AMD Milan 7543 (2.8GHz/32 cores/256MB/225W) CPU module (CTO&BTO) |
| 0231ALMG | 0231ALMG - AMD Milan 7573X(2.80GHz/32-core/768MB/280W)CPU module(CTO&BTO) |
| 0231ALPC | 0231ALPC - AMD Milan 75F3(2.95GHz/32-core/256MB/280W)CPU module(CTO&BTO) |
| 0231ALP5 | 0231ALP5 - AMD Milan 7643(2.3GHz/48-core/256MB/225W)CPU module(CTO&BTO) |
| 0231ALN6 | 0231ALN6 - AMD Milan 7663(2.0GHz/56-core/256MB/240W)CPU module(CTO&BTO) |
| 0231ALNA | 0231ALNA - AMD Milan 7713(2.0GHz/64-core/256MB/225W)CPU module(CTO&BTO) |
| 0231ALN5 | 0231ALN5 - R4950 G5 Server |
| 0231ALPH | 0231ALPH - AMD Milan 7763(2.45GHz/64-core/256MB/280W)CPU module(CTO&BTO) |
| 0231ALN2 | 0231ALN2 - AMD Milan 7773X(2.20GHz/64-core/768MB/280W)CPU module(CTO&BTO) |
| 0231ALMF | UN-CPU-AMD-7A23 - AMD Milan 7A23 (2.8GHz/48 cores/192MB/280W) CPU module (CTO&BTO) |
| Memory | |
| 0231ABDT | 0231ABDT - 16GB 2Rx8 DDR4-2933P-RMemory Module(FIO) |
| 0231ABDU | 0231ABDU - 32GB 2Rx4 DDR4-2933P-RMemory Module(FIO) |
| 0231AC4L | 0231AC4L - 64GB 2Rx4 DDR4-2933P-RMemory Module(FIO) |
| 0231AF6N | 0231AF6N - R4950 G5 Server |
| 0231AF6R | 0231AF6R - 16GB 2Rx8 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AF76 | UN-DDR4-3200AA-32G-2Rx4-R - 32GB 2Rx4 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AFXJ | 0231AFXJ - 16GB 1Rx8 DDR4-3200 CAS-22-22-22 RDIMM UniICMemory Module(CTO&BTO) |
| 0231AFXK | UN-DDR4-3200AA-64G-2Rx4-R-U - 64GB 2Rx4 DDR4-3200 CAS-22-22-22 RDIMM UniICMemory Module(CTO&BTO) |
| 0231AFXU | UN-DDR4-3200AA-32G-2Rx8-R-U - 32GB 2Rx8 DDR4-3200 CAS-22-22-22 RDIMM UniICMemory Module(CTO&BTO) |
| 0231AG95 | UN-DDR4-3200AA-32G-2Rx8-R - 32GB 2Rx8 DDR4-3200 CAS-22-22-22 RDIMMMemory Module(CTO&BTO) |
| 0231AJ2D | 0231AJ2D - 128GB 4Rx4 DDR4-3200 CAS-26-22-22 3DS SAMSUNG RDIMMMemory Module(CTO&BTO) |
| 0231AM1T | UN-DDR4-3200AA-32G-2Rx8-R-2 - 32GB 2Rx8 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| 0231AM1V | 0231AM1V - R4950 G5 Server |
| 0231AM1W | 0231AM1W - 16GB 2Rx8 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| 0231AM21 | 0231AM21 - R4950 G5 Server |
| 0231AM24 | 0231AM24 - R4950 G5 Server |
| 0231AM25 | UN-DDR4-3200AA-32G-2Rx4-R-2 - 32GB 2Rx4 DDR4-3200AA(CAS-22-22-22)SAMSUNG&HYNIX RDIMMMemory Module(CTO&BTO) |
| 0231AM29 | 0231AM29 - R4950 G5 Server |
| 2120A09E | UN-DUMMY-DIMM-DDR4 - DDR4 fake memory module |
| Front Hard Drive Cage | |
| 0231AHVU | UN-BP-25SFF-L36-G5 - G5 25SFF hard drive expansion module (CTO & BTO) |
| 0231AEYM | UN-PCA-BP-25SFF-2U-G5 - G5 25SFF hard drive backplane module (CTO & BTO) |
| 0231AEYV | UN-PCA-BP-8UniBay-2U-G5 - G5 25SFF Uni Bay hard drive backplane module (CTO & BTO) |
| 0231AGC5 | UN-PCA-BP-8UniBay-2U-G5-SP - G5 8SFF Uni Bay hard drive backplane module (SP) (CTO&BTO) |
| 0231AEYE | UN-PCA-BP-8SFF-2U-G5 - G5 8SFF hard drive backplane module (CTO & BTO) |
| Rear Hard Drive Cage | |
| 0231AF5R | UN-HDDCage-2LFF-2U-G5 - G5 2U rear 2LFF disk cage module (CTO&BTO) |
| 0231AF55 | UN-HDDCage-2SFF-2UniBay-2U-G5 - G5 2U rear 2Uni Bay disk cage module (CTO&BTO) |
| 0231AF5K | UN-HDDCage-4LFF-2U-G5 - H3C Uni Server G5 2U rear 4x LFF drive cage module (CTO & BTO) |
| 0231AF5C | UN-HDDCage-4SFF-4UniBay-2U-G5 - G5 2U rear 4x Uni Bay drive cage module (CTO & BTO) |
| M.2 SSD | |
| 0231ABTD | 0231ABTD - R4950 G5 Server |
| 0231AK1R | 0231AK1R - 480GB 6G SATA RI 5400PRO M.2 SSDHard Drive Module(CTO&BTO) |
| 0231AES6 | 0231AES6 - R4950 G5 Server |
| 0231AHCQ | UN-SSD-480G-SATA-S4520-M.2 - 480GB SATA RI S4520 M.2 SSDHard Drive Module(CTO&BTO) |
| 0231ABTE | 0231ABTE - R4950 G5 Server |
| M.2 Adapter Card | |
| 0231AF5Q | UN-RC-2M2-G5 - G5 front 2*M.2 2280/22110 Riser module(CTO&BTO) |
| Diagnostics Panel | |
| 0231AE9Y | UN-SID-LCD-SFF-M - SFF LCD panel module (CMCTO) |
| PCIe Adapter Card | |
| 0231AF52 | UN-RC-3FHFL-2U-SW-G5 - G5 2U 3X16 Riser (slot 1/2) (supports 2 FHFL and 1 FHHL, supports 2x 150W GPU) (CTO&BTO) |
| 0231AF5A | UN-RC-3FHFL-2U-G5 - G5 2U X16X8X8 Riser (slot 1/2) (supports 2 FHFL and 1 FHHL, supports 1 300W GPU) (CTO&BTO) |
| 0231AF5L | UN-RC-2HHHL-R3-2U-G5 - G5 2U X8X8 Riser(Slot3)(Supports 2 x HHHL)(CTO&BTO) |
| 0231AFP0 | 0231AFP0 - H3C Uni Server R4950 G5 OCP2.0/FHHL adapter card (slot 1/2)(supports 1x X16 OCP and 1x X16 FHHL)(CTO&BTO) |
| 0231AFT5 | UN-PCA-R4900-4GPU-G5 - H3C Uni Server G5 4GPUModule(CTO&BTO) |
| 0231AFT9 | UN-RC-2FHFL-R3-2U-G5 - G5 2U X8X8 Riser card (slot 3) (supports 2 FHFL, supports 2x 150W GPU) (CTO&BTO) |
| 0231AFTP | UN-RC-1FHFL-R3-2U-G5 - G5 2U X16 Riser card (slot 3) (supports 1 FHFL, supports 1x 300W GPU) (CTO&BTO) |
| 0231AFUD | UN-RC-2LP-SlimSAS-2U - SlimSAS LP adapter card (slot 3) (supports 2 x X8 HHHL) (CTO&BTO) |
| 0231AFXW | UN-RC-GPU/FHHL-2U-G5 - H3C Uni Server G5 2U X16X8 Riser (slot 1/2) (supports 1 custom GPU card, 1 FHHL module) (CTO&BTO) |
| Hard Disk Array Controller Card (Requires a PCIe Adapter Card) | |
| 0231A7HB | UN-RAID-LSI-9460-16i(4G)-F - LSI 9460-16i 12G SAS RAID card module (supports 16 SAS Ports, with 4GB cache, PCIe, excludes supercapacitors) (CMCTO) |
| 0231A8AY | UN-RAID-LSI-9460-8i(4G)-F - LSI 9460-8i 12G SAS RAID controller module (supports 8 x SAS Ports, includes 4GB cache, PCIe, excluding supercapacitor) (CMCTO) |
| 0231A8B0 | UN-HBA-LSI-9440-8i-F - LSI 9440-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| 0231A8B5 | UN-RAID-LSI-9460-8i(2G)-F - LSI 9460-8i 12G SAS RAID card module (supports 8 SAS Ports, with 2GB cache, PCIe, without supercapacitor) (CMCTO) |
| 0231A8JY | 0231A8JY - LSI 9361-8i 12G SAS RAID card module (supports 8 x SAS Ports, with 1GB cache, PCIe, excluding power-loss protection module) (CMCTO) |
| 0231A8K4 | 0231A8K4 - LSI 9361-8i 12G SAS RAID card module (supports 8 x SAS Ports, with 2GB cache, PCIe, excluding power-loss protection module) (CMCTO) |
| 0231A8KA | UN-HBA-LSI-9300-8i-A1 - LSI 9300-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| 0231A8ND | UN-HBA-H460-B1-F - H460-B1 12G SAS HBA card module (supports 8 SAS ports, PCIe) (CMCTO) |
| 0231A8P1 | UN-RAID-P460-B4-F - P460-B4 12G SAS RAID card module (supports 8 SAS Ports, with 4GB cache, excluding supercapacitor) (CMCTO) |
| 0231AAUF | 0231AAUF - P460-B2 12G SAS RAID card module (supports 8 SAS ports, with 2GB cache, excluding supercapacitor) (CMCTO) |
| 0231AB06 | UN-HBA-LSI-9311-8i-F - LSI 9311-8i 12G SAS HBA card module (supports 8 x SAS Ports, PCIe) (CMCTO) |
| 0231AE6E | UN-HBA-LSI-9400-16i-M - LSI 9400-16i 12G SAS HBA card module (supports 16 SAS Ports, PCIe) (CMCTO) |
| OCP3.0 Network Adapter | |
| 0231ABWF | UN-NIC-MCX4621A-ACAB-2*25G-M - 2-Port25G OCP3.0Network Adapter(MCX4621A-ACAB)(FIO) |
| Optical Module | |
| 0231A7N6 | SFP-25G-SR-MM850-1 - 25G SFP28Optical Module(850nm,100m,SR,MM,LC) |
| 0231AEBU | UN-NIC-ETH360T-3S-4P - 4-Port1GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBV | UN-NIC-ETH565T-3S-2P - 2-Port10GEelectrical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AEBW | UN-NIC-ETH640F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231A8KB | UN-SFP-XG-SX-MM850-E1 - SFP+ 10GModule(850nm,300m,LC) |
| 0231AEBX | 0231AEBX - R4950 G5 Server |
| 0231AEBY | UN-NIC-ETH561F-3S-2P - 2-Port10GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AFH3 | UN-NIC-ETH660F-3S-2P - 2-Port25GEoptical interfaceOCP3.0Network Adapter(CTO&BTO) |
| 0231AG96 | UN-NIC-ETH-MCX631432AN-ADAB-2P - 2-Port25Gb SFP28optical interfaceMCX631432AN OCP3.0Network Adapter(CTO&BTO) |
| 0231AGFL | UN-NIC-ETH-MCX623436AN-CDAB-2P - 2-Port100Gb optical interfaceMCX623436AN-CDAB OCP3.0Network Adapter(CTO&BTO) |
| 0231AC16 | QSFP-100G-SR4-MM850-CM - 100G QSFP28 optical module (850nm, 100m OM4, SR4, MPO) (FIO) |
| 0231AGL9 | 0231AGL9 - R4950 G5 Server |
| Network Card (Requires PCIe Adapter Card) | |
| 0231A7G6 | UN-NIC-MCX4121A-F-B-25Gb-2P-F - 2-Port25Gboptical interface Network Adapter(SFP28)(FIO) |
| 0231A7GL | 0231A7GL - R4950 G5 Server |
| 0231A7GM | 0231A7GM - R4950 G5 Server |
| 0231AFUN | UN-CAB-IB-DAC-MCP1600-E003E26-3m - Mellanox 3m EDR 100G DAC Cable (CTO&BTO) |
| 0231A7NA | UN-CNA-560T-B2-10Gb-2P-1 - 2-Port10Gbelectrical interface Network Adapter-560T-B2 |
| 0231A7NH | UN-NIC-620F-B2-25Gb-2P-1 - 2-Port25Gboptical interface Network Adapter(SFP+)-620F-B2 |
| 0231A7PW | UN-NIC-BCM957412-F-B-10Gb-2P-F - 2-Port10GEoptical interface Network Adapter(BCM957412)(FIO) |
| 0231A7PX | UN-NIC-BCM957416-T-B-10Gb-2P-F - 2-Port10GEelectrical interface Network Adapter(BCM957416)(FIO) |
| 0231A7Q2 | UN-NIC-BCM957414-F-B-25Gb-2P-F - 2-Port25GEoptical interface Network Adapter(BCM957414)(FIO) |
| 0231A7WC | UN-NIC-X710DA4-F-B-10Gb-4P-F - 4-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A8K1 | UN-NIC-GE-4P-360T-B2-1 - 4-Port Gigabitelectrical interface Network Adapter-360T-B2 |
| 0231A8K2 | UN-CNA-10GE-2P-560F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-560F-B2 |
| 0231A8K9 | UN-NIC-10GE-2P-530F-B2-1 - 2-Port10Goptical interface Network Adapter(SFP+)-530F-B2 |
| 0231A9AU | UN-NIC-X710DA2-F-B-10Gb-2P-F2 - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231A9B7 | UN-NIC-X520DA2-F-B-10Gb-2P-F - 2-Port10GEoptical interface Network Adapter(SFP+)(FIO) |
| 0231AB04 | 0231AB04 - R4950 G5 Server |
| 0231AB5W | UN-NIC-MCX512A-ACAT-F-2*25Gb-F - 2-Port25Gboptical interface Network Adapter(SFP28)(MCX512A-ACAT)(FIO) |
| 0231AEC7 | 0231AEC7 - 1-port 100Gb QSFP28 Optical Interface MCX515A-CCAT Ethernet NIC (CMCTO) |
| 0231AEC8 | UN-NIC-ETH-MCX516A-CCAT-2P-M - 100Gb 2-Port QSFP28 Optical Interface MCX516A-CCAT Ethernet Card (CMCTO) |
| 0231AF89 | 0231AF89 - R4950 G5 Server |
| 0231AF8A | UN-NIC-X2522-25Gb-2P-M - 2-port 25Gb SFP28 Optical Interface X2522-25G-PLUS low-latency network card (CTO&BTO) |
| 0231AFGV | 0231AFGV - R4950 G5 Server |
| 0231AFH5 | UN-NIC-ETH630F-LP-2P - 2-Port25GEoptical interface Network Adapter (ETH630F)(CTO&BTO) |
| 0231AFN8 | UN-IB-MCX653105A-HDAT-200Gb-1P - 200Gb 1-Port Infini Band HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231AFRV | UN-NIC-ETH531F-LP-2P - 2-Port10GEoptical interface Network Adapter(CTO&BTO) |
| 0231AFUG | UN-NIC-ETH-MCX631102AN-ADAT - 2-port 25Gb SFP28 Optical Interface MCX631102AN-ADAT Ethernet card (CTO&BTO) |
| 0231AFUR | 0231AFUR - R4950 G5 Server |
| 0231AFUP | UN-CAB-IB-DAC-MCP7H50-V002R26-2m - Mellanox 2m HDR100 100G DAC breakout cable (CTO&BTO) |
| 0231AFUS | UN-IB-MCX653106A-ECAT-100Gb-2P - 100Gb 2-Port Infiniband HDR/Ethernet Adapter Card (Supports QSFP56 Optical Modules) (CTO&BTO) |
| 0231AGJA | UN-NIC-ETH-MCX623106AN-CDAT-2P - 2-Port100Gb QSFP56optical interfaceMCX623106AN-CDATNetwork Adapter(CTO&BTO) |
| 0231AK5Y | UN-NIC-ETH330T-LP-4P - 4-PortGEelectrical interface Network Adapter(CTO&BTO) |
| 0231AM5N | UN-IB-MCX75310AAS-HEAT-200Gb-1P - 1-port 200Gb Infiniband NDR/Ethernet adapter card (supports OSFP optical modules) (CTO&BTO) |
| 0231ANJD | UN-NIC-ETH-RP1000P2SFP-LP-2P - 2-Port10GEoptical interface Network Adapter(RP1000P2SFP)(CTO&BTO) |
| 0231ANJJ | UN-NIC-ETH-SF400T-LP-4P-GE - 4-Port1GEelectrical interface Network Adapter(SF400T)(CTO&BTO) |
| Graphics card (requires a PCIe adapter card) | |
| 0231AGGQ | 0231AGGQ - R4950 G5 Server |
| 0231AFJE | 0231AFJE - R4950 G5 Server |
| 0231AH39 | 0231AH39 - R4950 G5 Server |
| 0231AJFS | UN-GPU-A16-64G-DW - NVIDIA A16 64G GPUModule(CTO&BTO) |
| 0231AGPS | 0231AGPS - R4950 G5 Server |
| 0231AKCL | 0231AKCL - R4950 G5 Server |
| 0231AG9X | UN-GPU-A10-24G - NVIDIA Tesla A10 24G GPUModule(Non-CEC)(CTO&BTO) |
| 0231AGSV | 0231AGSV - R4950 G5 Server |
| 0231AEDK | 0231AEDK - R4950 G5 Server |
| 0231ANMC | 0231ANMC - Nvidia L2 24G PCIe4.0 X16 HHHL GPUModule(CTO&BTO) |
| 0231AJWB | 0231AJWB - Nvidia Quadro A6000 48GB GPUModule(CTO&BTO) |
| 0231AJHY | 0231AJHY - R4950 G5 Server |
| 0231AK45 | 0231AK45 - R4950 G5 Server |
| 0231AJWD | 0231AJWD - R4950 G5 Server |
| 0231ABT8 | UN-GPU-T4-F - T4 Display Acceleration Card (FIO) |
| SSD Acceleration Card (Requires a PCIe Adapter Card) | |
| 0231AG89 | 0231AG89 - R4950 G5 Server |
| 0231AHWE | UN-SSD-3.2T-NVMe-PB6536-AIC - 3.2T NVMe SSD PB6 6536 SSD PCIe acceleration card module (CTO&BTO) |
| 0231AEY1 | UN-SSD-3.2T-NVME-PB926-AIC-M - 3.2T NVMe SSD MU PBlaze5 926 PCIe accelerator card (CMCTO) |
| 0231AJ64 | UN-SSD-6.4T-NVMe-PB6536-AIC - 6.4T NVMe SSD PB6 6536 SSD PCIe acceleration card module (CTO&BTO) |
| Fiber Channel HBA card (requires PCIe adapter card) | |
| 0231A7LN | UN-FC-HBA-LPe32002-32Gb-2P - 2-port 32Gb optical fiber channel HBA card (with two SFP+ optical modules) |
| 0231A7NB | UN-HBA-16Gb-LPe31000-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module) |
| 0231A7NF | UN-HBA-16Gb-LPe31002-2P-1 - 2-port 16Gb Fibre Channel HBA card (with two SFP+ modules) |
| 0231A7PV | UN-FC-HBA-QLE2742-32Gb-2P-F - 32Gb-2-port-PCIe Fibre Channel HBA card (with two SFP+ optical modules) (FIO) |
| 0231A8JQ | UN-FC-HBA-QLE2690-16Gb-1P-1 - 1-port 16Gb Fibre Channel HBA card (with one SFP+ module) |
| 0231A8JR | 0231A8JR - R4950 G5 Server |
| 0231A8JU | 0231A8JU - R4950 G5 Server |
| 0231A8JV | UN-FC-HBA-QLE2692-16Gb-2P-1 - 2-port 16Gb Fibre Channel HBA card (with two SFP+ modules) |
| 0231AGHH | UN-FC-HBA-LPe35000-LP-32Gb-1P - 1-port 32Gb Optical Interface LPe35000 AIC FC HBA card (PCIe 4.0) (comes with one SFP+ optical module) (CTO&BTO) |
| 0231AGHJ | UN-FC-HBA-LPe35002-LP-32Gb-2P - 2-port 32Gb Optical Interface LPe35002 AIC FC HBA card (PCIe 4.0) (comes with two SFP+ optical modules) (CTO&BTO) |
| SD card | |
| 0231A6RC | UN-SD-32G-Micro-F - 32G microSD mainstream flash drive module (FIO) |
| SD card expansion module | |
| 0231A8L1 | UN-DSD-EX-F1 - Dual SD card expansion module (CTO & BTO) |
| Power Supply | |
| 0231A8KP | 0231A8KP - R4950 G5 Server |
| 0231AGUP | UN-GW-CRPS1300D3 - 1300W AC&240V HVDC power Module (GW-R1-Platinum-low load high efficiency) (CTO&BTO) |
| 0231AKDP | UN-PAC1K3D12-B2 - 1300W AC & 240V HVDC power Supply Module (HW-R1- Platinum) (CTO&BTO) |
| 0231ACT9 | DPS-1300AB-6 R-M - 1300W AC & 240V High-Voltage DC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231ACTG | FSP1600-20FH-M - 1600W 336V HVDC power Supply Module (dedicated power cable) (FP-R1- Platinum) (CMCTO) |
| 0231AHRV | UN-DD-2162-3L5 - 1600W 48V DC power Supply Module (LT-R1- Platinum) (CTO&BTO) |
| 0231AGUN | UN-GW-CRPS1600D2 - 1600W AC & 240V HVDC power Supply Module (GW-R1- Platinum) (CTO&BTO) |
| 0231A7KH | 0231A7KH - 1600W AC & 240V HVDC power Supply Module (FP-R1-Platinum) (CMCTO) |
| 0231AFSS | UN-GW-CRPS2000D - 2000W AC & 240V HVDC power Supply Module (GW-R2- Platinum - light-load high efficiency) (CTO&BTO) |
| 0231AFQB | UN-DPS-2400EB B - 2400W AC & 240V HVDC power Supply Module (DT-R1-Platinum) (CTO&BTO) |
| 0231AE25 | GW-CRPS550N-M - 550W AC & 240V HVDC power Module (GW-R1-platinum) (CMCTO) |
| 0231ACTH | 0231ACTH - 550W AC & 240V HVDC power Supply Module (LT-R1-Platinum) (CMCTO) |
| 0231A9CE | 0231A9CE - 550W AC & 240V HVDC power Supply Module (DT-R1-Platinum) (CMCTO) |
| 0231A8KX | 0231A8KX - R4950 G5 Server |
| 0231AHNS | UN-PAC800D12-B2 - 800W AC & 240V HVDC power supply (HW-R1-Platinum-Light-load efficiency) (CTO & BTO) |
| 0231AE22 | 0231AE22 - R4950 G5 Server |
| 0231AGUQ | UN-GW-CRPS800N2 - 800W AC & 240V HVDC power Supply Module (GW-R2-Platinum-Efficient at Light Load) (CTO&BTO) |
| 0231A8L0 | 0231A8L0 - R4950 G5 Server |
| 0231A6UG | PSR800-12AHD-FIO - 800W 336V HVDC power Supply Module (dedicated power cable) (FP-R1, Platinum) (CMCTO) |
| 0231A8AX | PSR850-12A-FIO - 850W AC & 240V HVDC power Supply Module (DT-R1- Titanium) (CMCTO) |
| 0231A9CJ | DPS-850W-12A-F - 850W AC & 240V High-Voltage DC power Module (DT-R1-Platinum) (CMCTO) |
| 0231A9CF | DPS-800W-12A-48V-F - 800W (-48V)-(-60V) DC power Supply Module (DT-R1, Gold) (CMCTO) |
| No-power-cord power supply | |
| 0231ALYS | UN-CRPS-1300W-AC-12V-94%-M2 - 1300W AC & 240V HVDC power supply (Platinum - light-load high efficiency) (CMCTO) |
| Power Supply Cable | |
| 0404A0K4 | CAB-PDU-2.0m-C14-C13-MUL-50598 - PDU Power Supply Cable - 2.0 m - 1.0 mm² - Black - (C14 Connector (3P) Straight Male 250V 10A) - (227 IEC 53 (RVV) & H05VV-F & SJT) - (C13) - Chinese Standard + U.S. Standard + European Standard + Korean Standard |
| 0404A06Q | CAB-AC Pwr CHI-1.8m - Wall-mounted AC power cord—1.8 m—3 × 0.75 mm²—black—(GB1002 plug (3P), straight male, 250 V, 10 A)—(227 IEC 53 (RVV))—(C13 connector (3P), straight female, 250 V, 10 A)—Chinese National Standard |
| Fan | |
| 0231AF5E | UN-FAN-6038-2U-G5 - G5 2U 6038Fan Module(CTO&BTO) |
| 0231AF5G | UN-FAN-6056-2U-G5 - H3C Uni Server G5 2U 6056Fan Module(CTO&BTO) |
| Air Deflector | |
| 0231AFCQ | UN-ME-AirBaffle-GPU-R4950G5 - R4950/R4930 G5 GPU dedicated air baffle module (CTO&BTO) |
| 2120A075 | UN-ME-AirBaffle-OCP-GPU-G5 - H3C Uni Server R4950 G5 OCP GPU-specific air guide module |
| 2120A076 | UN-ME-AirBaffle-OCP-G5 - H3C Uni Server R4950 G5 OCP air guide module |
| 2120A096 | UN-ME-AirBaffle-R1-G5 - H3C Uni Server R4950 G5 Riser1 air guide module |
| Optical Drive | |
| 0231A6R9 | 0231A6R9 - Mobile USB 2.0 interface read/write optical drive module (FIO) |
| Rack Rail | |
| 0231APX9 | UN-RL-G-G6 - G6 2U/1U Ball Screw Guide Rails (CTO & BTO) |
| 0231AF5B | UN-RL-G-G5 - G5 2U/1U Ball-Bearings Slides (CTO & BTO) |
| Cable Management Tray | |
| 2150A0EE | CMA-2U-A - 2U Cable Management Rack |
| 0231AQCE | UN-CMA-2U-G6 - G6 2U Cable Management Rack (CTO & BTO) |
| Tag | |
| 0231AGWU | UN-Label-Shock&Tilt Monitor - Anti-tilt label and 37G anti-vibration label (CTO&BTO) |
| Is customization Required? | |
| CUSTNEED | CUSTNEED - R4950 G5 Server |
| Customized module | |
| 0231A8A6 | UN-CTM-G3-F - H3C customer-specific customization module (1H) (FIO) |
| Installing Services | |
| 8814A0VA | SV-PS-OEM-SERV-ISS - OEM server initial basic installation service |
| Operating System Compatibility Verification | |
| BATJOSXX | BATJOSXX - R4950 G5 Server |
| OSCHECKX | OSCHECKX - R4950 G5 Server |
| Windows | |
| WNDS2016 | WNDS2016 - R4950 G5 Server |
| 2019R0XX | 2019R0XX - R4950 G5 Server |
| 2022R0XX | 2022R0XX - R4950 G5 Server |
| linux | |
| H3LX202S | H3LX202S - R4950 G5 Server |
| H3LXV202 | H3LXV202 - R4950 G5 Server |
| 78ENTHAT | 78ENTHAT - R4950 G5 Server |
| 79ENTHAT | 79ENTHAT - R4950 G5 Server |
| 82ENTHAT | 82ENTHAT - R4950 G5 Server |
| 83ENTHAT | 83ENTHAT - R4950 G5 Server |
| 84ENTHAT | 84ENTHAT - R4950 G5 Server |
| 85ENTHAT | 85ENTHAT - R4950 G5 Server |
| 86ENTHAT | 86ENTHAT - R4950 G5 Server |
| 87ENTHAT | 87ENTHAT - R4950 G5 Server |
| 88ENTHAT | 88ENTHAT - R4950 G5 Server |
| 90ENTHAT | 90ENTHAT - R4950 G5 Server |
| 91ENTHAT | 91ENTHAT - R4950 G5 Server |
| 92ENTHAT | 92ENTHAT - R4950 G5 Server |
| ROCKYL86 | ROCKYL86 - R4950 G5 Server |
| ROCKYL92 | ROCKYL92 - R4950 G5 Server |
| SLE12SP5 | SLE12SP5 - R4950 G5 Server |
| SLE15SP1 | SLE15SP1 - R4950 G5 Server |
| SLE15SP2 | SLE15SP2 - R4950 G5 Server |
| SLE15SP3 | SLE15SP3 - R4950 G5 Server |
| SLE15SP4 | SLE15SP4 - R4950 G5 Server |
| UOS2050E | UOS2050E - R4950 G5 Server |
| UBSE1843 | UBSE1843 - R4950 G5 Server |
| UBSE204X | UBSE204X - R4950 G5 Server |
| UBSE2041 | UBSE2041 - R4950 G5 Server |
| UBSE2044 | UBSE2044 - R4950 G5 Server |
| UBSE2045 | UBSE2045 - R4950 G5 Server |
| UBSE224X | UBSE224X - R4950 G5 Server |
| O2203LTS | O2203LTS - R4950 G5 Server |
| O223LTS1 | O223LTS1 - R4950 G5 Server |
| HyperVisors | |
| CAS535H6 | CAS535H6 - R4950 G5 Server |
| CASE0708 | CASE0708 - R4950 G5 Server |
| CASE0780 | CASE0780 - R4950 G5 Server |
| CTXS81XX | CTXS81XX - R4950 G5 Server |
| CTXS82XX | CTXS82XX - R4950 G5 Server |
| VMES67U3 | VMES67U3 - R4950 G5 Server |
| VMES70XX | VMES70XX - R4950 G5 Server |
| VMES70U1 | VMES70U1 - R4950 G5 Server |
| VMES70U2 | VMES70U2 - R4950 G5 Server |
| VMES70U3 | VMES70U3 - R4950 G5 Server |
| VMES8064 | VMES8064 - R4950 G5 Server |
| VMES80U1 | VMES80U1 - R4950 G5 Server |
| Community/Regional Enabled Oss | |
| CENTOS78 | CENTOS78 - R4950 G5 Server |
| CENTOS79 | CENTOS79 - R4950 G5 Server |
| CENTOS82 | CENTOS82 - R4950 G5 Server |
| CENTOS83 | CENTOS83 - R4950 G5 Server |
| CENTOS84 | CENTOS84 - R4950 G5 Server |
| CENTOS85 | CENTOS85 - R4950 G5 Server |
| Zhongbiao Kylin | |
| ZBQL10X2 | ZBQL10X2 - R4950 G5 Server |
| ZBQL1023 | ZBQL1023 - R4950 G5 Server |
| Other Operating Systems | |
| NINGV312 | NINGV312 - R4950 G5 Server |
| OTHERSOS | OTHERSOS - R4950 G5 Server |
| Product Identity | |
| Brand | H3C |
| Series | WB R4950 G5 rack server |
Reviews
No reviews yet
Be the first to review this enterprise product.
Warranty
Standard Warranty Policy
All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.
- 1-Year Advance Replacement (RMA)
- 3-Year Free Repair Service
- Full coverage for functionality defects
Hassle-Free RMA Process
We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.
- 30-Day satisfaction guarantee return window
- Automated RMA portal access for instant tracking
- Restocking fee waived for functionality issues
Certified Engineering Support
Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.
- Free pre-sales topology consultation
- Remote troubleshooting & firmware advice
- Simulation lab testing before dispatch
Global Logistics & Packaging
We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.
- Double-walled boxes with customer molded foam
- Blind shipping support for channel partners
- Real-time tracking via FedEx / DHL / UPS
Resources
FAQ
What is the Optical Drive specification for WB-R4950-G5-SFF-C?
What is the Authentication specification for WB-R4950-G5-SFF-C?
What is the Warranty specification for WB-R4950-G5-SFF-C?
What is the Model specification for WB-R4950-G5-SFF-C?
Is this product Brand New?
What is the warranty period?
Do you offer volume discounts?
How fast can you ship?
Still have questions?