| Performance & Capacity |
| System Bandwidth | Maximum 800G data bandwidth |
| Throughput | 10-Gbps line-rate throughput per SFP+ port; 25-Gbps line-rate throughput per SFP28 port; 100-Gbps line-rate throughput per QSFP28 or QSFP-DD port |
| Capacity | Up to 800 Gbps of nonblocking, full-duplex capacity |
| Ethernet Standards | 10-Gbps IEEE 802.3ae compliant; 25-Gbps IEEE 802.3by and IEEE 802.3cc compliant; 40/100-Gbps IEEE 802.3ba compliant; 100 Gigabit Ethernet PHY monitoring; IEEE 802.x flow control; Full-duplex operation; Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets |
| Interfaces and Port Density |
| Integrated Ports | 2 QSFP-DD ports capable of 10Gb, 40Gb, and 100Gb Ethernet; 6 QSFP28 ports capable of 10Gb, 40Gb, and 100Gb Ethernet; 16 SFP28 dual-rate ports capable of 25Gb and 10Gb Ethernet; 24 SFP+ ports capable of 10Gb Ethernet (LAN) and WAN (OTN) |
| MACSec Support | All ports support MACSec |
| Route Processor Interfaces | Console and auxiliary serial ports; 2 management Ethernet interfaces; Class A USB port; GPS interface (10Mhz, 1PPS, ToD ports); 2 BITS interfaces |
| Pluggable Interfaces | Mix and match 10, 25, 40, and 100 Gigabit Ethernet interface types |
| DWDM Support | DWDM support based on the Optical Transport Network (OTN) protocol that is specified in ITU-T G.709 |
| Physical Dimensions and Weight |
| Dimensions (H x W x D) | 3.45 x 17.3 x 19 in. (87.63 x 439.74 x 482.60 mm) |
| Weight | 46.39 lb (21.04 kg) including 2 RPs, 2 PSUs, 3 FANs |
| Depth Excluding Ejector | 19 in./482.6 mm |
| Form Factor | 2RU |
| Rack Mounting | 2-post and 4-post 19-in. and 23-in. |
| Airflow | Front to back |
| Redundancy |
| Configuration | Fully redundant: 2 RPs, 2 power supply modules, 3 fan modules; Route processor redundancy; Power supply redundancy; Fan redundancy; Software redundancy |
| Route Processor |
| CPU Memory | SDRAM DDR4 – 32GB; 64-bit Intel CPU |
| Power |
| Power Modules | 1.6 kW DC power module (up to 2 modules), redundancy: 1+1; 1.6 kW AC power module (up to 2 modules), redundancy: 1+1 |
| Mixing AC/DC | Mixing of AC and DC modules is not supported |
| Environmental Specifications |
| Operating Temperature | 41 to 104°F (5 to 40°C). Limitations may apply when using high-power optics |
| Operating Humidity | 10 to 85% (relative humidity) |
| Storage Temperature | –40 to 158°F (–40 to 70°C) |
| Storage Humidity | 5 to 95% (relative humidity). Not to exceed 0.024 kg of water per kg of dry air |
| Operating Altitude | 0 to 4000 m. Limitations may apply when using high-power optics |
| ETSI/EN Standards |
| Compliance | EN300 386: Telecommunications Network Equipment (EMC); ETSI 300 019 Storage Class 1.1; ETSI 300 019 Transportation Class 2.3; ETSI 300 019 Stationary Use Class 3.1; EN55022: Information Technology Equipment (Emissions); EN55024: Information Technology Equipment (Immunity); EN50082-1/EN-61000-6-1: Generic Immunity Standard |
| EMC Standards |
| Compliance | FCC Class A; ICES 003 Class A; AS/NZS 3548 Class A; CISPR 22 (EN55022) Class A; VCCI Class A; BSMI Class A; IEC/EN 61000-3-2: Power Line Harmonics; IEC/EN 61000-3-3: Voltage Fluctuations and Flicker; EN50121-4 Railway Applications Part 4: Emission and immunity of the signaling and telecommunications apparatus |
| Immunity |
| Compliance | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air); IEC/EN-61000-4-3: Radiated Immunity (10V/m); IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal); IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM); IEC/EN-61000-4-5: Signal Ports (1kV); IEC/EN-61000-4-5: Surge DC Port (1kV); IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms); IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m); IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations; EN 50121-4: Railway EMC |
| Safety |
| Compliance | UL/CSA/IEC/EN 60950-1; IEC/EN 60825 Laser Safety; ACA TS001; AS/NZS 60950; FDA: Code of Federal Regulations Laser Safety |
| NEBS |
| Compliance | SR-3580: NEBS Criteria Levels (Level 3); GR-1089-CORE: NEBS EMC and Safety; GR-63-CORE: NEBS Physical Protection |
| Features and Benefits |
| Interface support | Cisco Pluggable interfaces; Provides the capacity to mix and match 10, 25, 40, and 100 Gigabit Ethernet interface types across the ASR 9902 chassis. For a complete list of supported pluggable interfaces, see the Cisco Optics Compatibility Matrix. |
| DWDM | DWDM support based on the Optical Transport Network (OTN) protocol that is specified in ITU-T G.709. This standard combines the benefits of SONET/SDH technology with the multi-wavelength networks of DWDM. It also provides for Forward Error Correction (FEC) that can allow a reduction in network costs by reducing the number of regenerators used. |
| Carrier-class OAM | NetFlow, IEEE 802.1ag, IEEE 802.3ah, ITU Y.1731, IP Service-Level Agreement (IP SLA), Virtual Circuit Connectivity Verification (VCCV), ping, and traceroute |
| Timing capability | Hardware-based IEEE 1588, GPS/BITS interfaces, and SyncE support; Delivers timing services over the packet network. Support of PTP Telecom profiles (G.8265.1, G.8275.1, G.8275.2). SyncE on Ethernet ports across the ASR 9902 chassis, support of GPS and BITS interfaces to provide redundant network synchronization. |
| Carrier-grade redundancy | Fully redundant configuration; Support of redundant configuration: 2 RPs, 2 power supply modules, 3 fan modules |
| Carrier-class OS | Cisco IOS XR Software (64-bit); Modular, patchable, scalable, highly available, carrier-core, and edge-proven operating system |
| Ordering Information - Flexible Consumption Model (FCM) |
| ASR-9902-FC | ASR 9902, 2RU, Flexible Consumption Chassis |
| A99-RP-F-FC | ASR 9900 Fixed Chassis Route Processor - Flexible Consumption Model |
| PWR-1.6KW-AC | ASR 9900 Fixed Chassis AC Power Supply |
| PWR-1.6KW-DC | ASR 9900 Fixed Chassis DC Power Supply |
| ASR-9902-FAN | ASR 9902 Fan Tray |
| ASR-9902-2P-KIT | ASR 9902 2-Post Mounting Kit for 19-Inch and 23-Inch Rack |
| ASR-9902-4P-KIT | ASR 9902 4-Post Mounting Kit for 19-Inch and 23-Inch Rack |
| ASR-9902-CAB-MGMT | ASR 9902 Cable Management |
| ASR-9902-FILTER | ASR 9902 Air Filter |
| S-A9K-LI-LIC-FC | ASR 9K Smart License Lawful Intercept – Flexible Consumption Model |
| ESS-ED-100G-RTU1 | Edge Essentials Software RTU License per 100G |
| ADV-ED-100G-RTU1 | Edge Advantage w/o Essentials Software RTU License per 100G |
| ADN-ED-100G-RTU1 | Edge Advantage w/ Essentials Software RTU License per 100G |
| ESS-ED-400G-RTU1 | Edge Essentials Software RTU License per 400G |
| ADV-ED-400G-RTU1 | Edge Advantage w/o Essentials Software RTU License per 400G |
| ADN-ED-400G-RTU1 | Edge Advantage w/ Essentials Software RTU License per 400G |
| ESS-ED-100G-SIA5 | Edge Essentials SIA per 100G 60-120 months |
| ESS-ED-100G-SIA3 | Edge Essentials SIA per 100G 36-59 months |
| ESS-ED-400G-SIA5 | Edge Essentials SIA per 400G 60-120 months |
| ESS-ED-400G-SIA3 | Edge Essentials SIA per 400G 36-59 months |
| ADV-ED-100G-SIA5 | Edge Advantage w/o Essentials SIA per 100G for 60-120 months |
| ADV-ED-100G-SIA3 | Edge Advantage w/o Essentials SIA per 100G for 36-59 months |
| ADV-ED-400G-SIA5 | Edge Advantage w/o Essentials SIA per 400G for 60-120 months |
| ADV-ED-400G-SIA3 | Edge Advantage w/o Essentials SIA per 400G for 36-59 months |
| ADN-ED-100G-SIA5 | Edge Advantage w/ Essentials SIA per 100G for 60-120 months |
| ADN-ED-100G-SIA3 | Edge Advantage w/ Essentials SIA per 100G for 36-59 months |
| ADN-ED-400G-SIA5 | Edge Advantage w/ Essentials SIA per 400G for 60-120 months |
| ADN-ED-400G-SIA3 | Edge Advantage w/ Essentials SIA per 400G for 36-59 months |
| Ordering Information - Traditional Business Model Hardware |
| ASR-9902 | ASR 9902 Chassis, 2RU |
| A99-RP-F | ASR 9900 Fixed Chassis Route Processor |
| PWR-1.6KW-AC | ASR 9900 Fixed Chassis AC Power Supply |
| PWR-1.6KW-DC | ASR 9900 Fixed Chassis DC Power Supply |
| ASR-9902-FAN | ASR 9902 Fan Tray |
| ASR-9902-2P-KIT | ASR 9902 2-Post Mounting Kit for 19-Inch and 23-Inch Rack |
| ASR-9902-4P-KIT | ASR 9902 4-Post Mounting Kit for 19-Inch and 23-Inch Rack |
| ASR-9902-CAB-MGMT | ASR 9902 Cable Management |
| ASR-9902-FILTER | ASR 9902 Air Filter |
| Feature Licenses - Traditional Business Model |
| S-A9902-IVRF | ASR 9902 License to Activate up to 8 VRFs for Fixed Ports |
| S-A9902-AIP | ASR 9902 Full-Scale VRF License for Fixed Ports |
| S-A9902-CGN | ASR 9902 In-Line CGv6 Translation License for Fixed Port |
| S-A9902-OPTLIC | ASR 9902 License to Activate Advanced Optical |
| S-A9K-MACSEC-10 | ASR 9000 MACSec 10G Right to Use license |
| S-A9K-MACSEC-40 | ASR 9000 MACSec 40G Right to Use license |
| S-A9K-MACSEC-100 | ASR 9000 MACSec 100G Right to Use license |
| S-A9K-LI-LIC | ASR 9K Smart License Lawful Intercept |
| S-A9K-TUNNEL-ENT | ASR 9K Smart License RTU License for Tunnel Protocols |
| S-A9K-MOBILE-LIC | ASR 9K Smart License Advanced Mobile for System |
| S-A9K-NVSAT1-LIC | NV Host License for 1 nV Client |
| S-A9K-NVSAT5-LIC | NV Host License for Up to 5 nV Clients |
| S-A9K-NVSAT20-LIC | NV Host License for Up to 20 nV Clients |
| Sustainability |
| Product Material Content | Information on product material content laws and regulations - Materials |
| Electronic Waste | Information on electronic waste laws and regulations, including products, batteries, and packaging - WEEE compliance |